• 제목/요약/키워드: Super high-rise

검색결과 189건 처리시간 0.019초

초고층아파트 주동 내 커뮤니티 공간의 거주자 위치 선호에 관한 연구 (A Study on the resident preference of location type for community spaces within super high-rise apartment building)

  • 김다해;이연숙;안창헌
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.33-36
    • /
    • 2009
  • Korea is the 3rd highest country in population density of the world,furthermore, 1/5 of Korean lives in Seoul with only 0.0% tiny area size. It explains the high-rise apartment has diffused so fast. Regardless of its height, almost all apartments have been planned in a very uniform way, ignoring the possibilities of vertical community and commercial culture. Since considerable number of residents have within building, ways to improve the community and commercial culture need to be explored. One major way to do is providing community space where residents are expected to use in a natural way. The purpose of this research is to identify preferred location of community space in each apartment building. Web guesting survey was used as main methodology. 83 data were collected during mid October, 2009. As results, lobby at the first floor was most favorably selected by super high-rise apartment residents due to convenience, accessibility.

  • PDF

Seismic design and elastic-plastic analysis of the hengda group super high-rise office buildings

  • Zhang, Xiaomeng;Ren, Qingying;Liu, Wenting;Yang, Songlin;Zhou, Yilun
    • Earthquakes and Structures
    • /
    • 제19권3호
    • /
    • pp.175-188
    • /
    • 2020
  • The Hengda Group super high-rise building in Jinan City uses the frame-core tube structural system. With a height of 238.3 m, it is above the B-level height limit of 150 m for buildings within 7-magnitude seismic fortification zones. Therefore, it is necessary to apply performance-based seismic design to this super high-rise building. In this study, response spectrum analysis and comparative analysis of the structure are conducted using two software applications. Moreover, elastic time-history analysis, seismic analysis under an intermediate earthquake, and elastic-plastic time-history analysis under rare earthquakes are performed. Based on the analysis results, corresponding strengthening measures are implemented at weaker structural locations, such as corners, wall ends connected to framed girders, and coupling beams connected to framed girders. The failure mode and failure zone of major stress components of the structure under rare earthquakes are analysed. The conclusions to this research demonstrate that weaker locations and important parts of the structure satisfy the requirements for elastic-plastic deformation in the event of rare earthquakes.

1990 년대 이후 우리나라 초고층 공동주거 공간계획의 발전방향에 관한 연구 - 서울의 40층 이상 주상복합 아파트 3침실형 평면의 외기노출면 실배치 방식을 중심으로 - (A Research on the Spatial Configuration of the Korean Super-high rise Multi-unit Housing after the 1990s - Focusing on the window-side room layout of the 3 bedroom plans in the commercial mixed building over 40 Stories in Seoul -)

  • 서경욱
    • 한국실내디자인학회논문집
    • /
    • 제20권2호
    • /
    • pp.139-146
    • /
    • 2011
  • An attempt is made to illuminate the characteristics of Korean high-rise apartment plans built after the 1990s in Seoul. Unlike the typical slab block plans of the past century, these plans were accommodated in a super-highrise building which normally integrates some portion of commercial areas on the lower floors. Thus, they are much different from the pre-1990s plans, so needs to have different strategy to adapt to the Korean dwellers' domestic requirements. This study reveals the topological patterns that appear in these new plans, and tries to relate these patterns to the old configuration patterns of the slab-type apartment houses. From the analysis, it was found that some important Korean dwellers' characteristics are still preserved, but at the same time, some unprecedented patterns were beginning to be absorbed into the spatial arrangement. At the end, suggestions are made on how this emerging trend of super-high rise can be better understood and evolved to enhance the living quality in a new multi-unit setting.

都市 超高層 住居建築의 室內空氣環境의 評價에 관한 硏究 (A Study on the Evaluation of Indoor Air Environment in Super High-Rise Dwelling House)

  • 박미진
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.119-125
    • /
    • 2002
  • The concept of dwelling space is tend to be changed not only to have reasonable mobility but also to have high quality of indoor air with psychologicaa satisfaction and comfortable. Moreover, recent constructed buildings have a big problem because of exhausted pollution gas and particles from building materials. More serious problem occurs from its high air tightness reducing the ventilation for saving the energy and superior adiabatic insulators to have high heat efficiency. Indoor air quality in super high-rise dwelling house was investigated by measuring pollutants such as $CO_2,=;CO,\;MO_2,\;R_n,\;TSP,\;PM_{10}$, HCHO, Offensive ordor. Subjective evaluation of residential environment is processed for the inhabitants who live in research space by testing environmental load in accordance with environment morphology, exterior environmental factor and post occupancy correlation and influence of attention.

The Use of Bracing Systems with MR Dampers in Super Tall Buildings

  • Aly, Aly Mousaad
    • 국제초고층학회논문집
    • /
    • 제5권1호
    • /
    • pp.31-41
    • /
    • 2016
  • High-rise buildings are increasingly viewed as having both technical and economic advantages, especially in areas of high population density. Increasingly taller buildings are being built worldwide. Increased heights entail increasing flexibility, which can result in serviceability problems associated with significant displacements and accelerations at higher floors. The purpose of this paper is to present the concept of a versatile vibration control technology (MR dampers with bracings) that can be used in super tall buildings. The proposed technology is shown to be effective, from a serviceability point of view, as well as resulting in dramatically reduced design wind loads, thus creating more resilient and sustainable buildings.

홍콩 버비나하이츠(Verbena Heights) 주거단지의 특징에 관한 연구 (A Study on the Architectural Characteristics of ¡?Verbena Heights¡?Estate in Hong Kong)

  • 이재훈;김남응;김성화
    • 한국주거학회논문집
    • /
    • 제13권3호
    • /
    • pp.21-31
    • /
    • 2002
  • The purpose of this study is to find the architectural characteristics of Verbena Heights, super high-rise complex housing, which has been most highly evaluated as a new town development model in Hong Kong, as a successful case of new housing type and sustainable design. The analyzed features of Verbena Heights are as follows; 1) Formation of various open spaces by a creative layout. 2) Enhancement of natural ventilation and daylighting by a linear plan instead of conventional cruciform plans. 3) Applications of integrated facade design for noise mitigation and for sunlight shading. 4) Adoption of energy-efficient devices, use of recyclable materials, and improvement of livability by a sustainable design process. These architectural characteristics provide the high-density high-rise housing with more efficient and comfortable environments for residents. And it is proved that the sustainable design can enhance the quality of dwelling environment.

Effects of turbulence intensity and exterior geometry on across-wind aerodynamic damping of rectangular super-tall buildings

  • Quan, Y.;Cao, H.L.;Gu, M.
    • Wind and Structures
    • /
    • 제22권2호
    • /
    • pp.185-209
    • /
    • 2016
  • Across-wind aerodynamic damping ratios are identified from the wind-induced acceleration responses of 15 aeroelastic models of rectangular super-high-rise buildings in various simulated wind conditions by using the random decrement technique. The influences of amplitude-dependent structural damping ratio and natural frequency on the estimation of the aerodynamic damping ratio are discussed and the identifying method for aerodynamic damping is improved at first. Based on these works, effects of turbulence intensity $I_u$, aspect ratio H/B, and side ratio B/D on the across-wind aerodynamic damping ratio are investigated. The results indicate that turbulence intensity and side ratio are the most important factors that affect across-wind aerodynamic damping ratio, whereas aspect ratio indirectly affects the aerodynamic damping ratio by changing the response amplitude. Furthermore, empirical aerodynamic damping functions are proposed to estimate aerodynamic damping ratios at low and high reduced speeds for rectangular super-high-rise buildings with an aspect ratio in the range of 5 to 10, a side ratio of 1/3 to 3, and turbulence intensity varying from 1.7% to 25%.

초고층 주상복합 건축물 마감공사의 공종별 생산성 비교에 관한 연구 (A Study on the Productivity Analysis of Finishing Works on Super High-rise Mixed_use Building)

  • 홍보배;김용만;김주형;김재준
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.165-170
    • /
    • 2010
  • Super high-rise mixed use buildings require a longer period for construction. Especially finishing work takes up about 40% of the whole construction period. Thus, finishing work is becoming an important factor in determining the construction period along with earth work and frame work. As the expected returns added by the reduction of the period and cost in constructing super high-rise mixed use buildings are huge, the expectations are now increasing for the possible gains. In this respect, as the period of finishing work is easier to be shortened than that of frame work, the efforts to acquire the technical knowledge to reduce the finishing work period are now being required. Accordingly, in this study, we aimed at suggesting the basic data for designing an economic plan for finishing-work procedure by analyzing the productivity of each work type of finishing work procedure on the basis of the execution and results of a construction method as a time-flexible finishing work plan. For this, we categorized the work types of finishing work procedure into each work unit and provided a work-system for each of them. Also, with case studies, we calculated the detailed amounts of the work-loads, required materials, productivity, and productivity index of the main work types of finishing work procedure and each of their separate work units as well as analyzed the relationship between the value results to suggest a better way to improve its productivity.

Shaking Table Test and Seismic Performance Evaluation of Shanghai Tower

  • Chunyu, Tian;Congzhen, Xiao;Hong, Zhang;Jinzhe, Cao
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.221-228
    • /
    • 2012
  • Shanghai Tower is a super high-rise building of 632 m height with 'mega frame-core- outrigger truss' structure system. Due to the complexity and irregularity of structure, shaking table test was carried out to investigate its seismic performance. A 1/40 scaled test model was designed, built and tested on shaking table under earthquake of small, moderate and large levels. The experimental results showed that the structure can meet the requirements of Chinese codes and reach scheduled performance objectives. Elastic and plastic time-history analysis on the structure were carried out and the results were compared to experimental results. Based on the research results some suggestions were proposed to contribute favorable effect on the seismic capacity of the structure.