• Title/Summary/Keyword: Super EBA

Search Result 18, Processing Time 0.018 seconds

각종 치과용 합착 Cement의 색소침투에 관한 실험적 연구

  • Chin, Yong-Whan;Kim, Sang-Se;Lee, Eun-Ho;Kim, Sung-Il;Ahn, Sang-Kyu
    • The Journal of the Korean dental association
    • /
    • v.12 no.8
    • /
    • pp.613-617
    • /
    • 1974
  • The authors have studied the marginal leakage of various dental cements; Fynal cement (Caulk), Zinc cement (S.S. White) Carbo cement (Shofu, Poly-carboxylate cement), EBA cement (Opotow alumina cement), Propac (G-C's zinc oxide euginol cement), and Super cement (Shofu oxyphosphate zinc cement), by means of penetration of 2% methylene blue solution between orden crown restorations and human teeth in 150 cases. The result revealed as follow 1. None of the cements tested were free from dye penetration. 2. There was a wide difference in dye penetration among the trade brands of dental cement when immersed in dye solution before setting of cements. 3. EBA cement and Carbo cement showed comparatively low grade of dye penetration at the restorative margins.

  • PDF

AN ELECTROCHEMICAL STUDY ON MICROLEAKAGE OF RETROGRADE FILLING USING DIFFERENT RETROGRANE FILLING MATERIALS, ROOT RESECTION ANGLE AND CAVITY PREPARATION INSTRUMENTS (역충전재 및 치근단 절제 각도와 와동 형성 기구에 따른 역충전물의 변연 누출에 관한 전기화학적 연구)

  • Kim, Jin-Woo;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.499-512
    • /
    • 1994
  • The purpose of this study was to evaluate the microleakage electrochemically using different retrograde filling materials, different root resection angle, and different cavity preparation instruments. 104 extracted single-rooted teeth were selected for this study. 100 teeth were used as experimental groups and four was used as controls. Anatomical crowns were resected, root canals were prepared, and the apical 2 mm of roots were removed. The experimental roots were randomly divided into five equal groups. Experimental groups : Group 1. no bevel, cavity preparation with ultrasonic instruments, amalgam filling Group 2. no bevel, cavity preparation with ultrasonic instruments, SuperEBA cement filling Group 3. no bevel, cavity preparation with ultrasonic instruments, desiccated ZOE filling Group 4. $45^{\circ}$ bevel, cavity preparation with ultrasonic instruments, amalgam filling Group 5. no bevel, cavity preparation with conventional bur, amalgam filling Microleakage was measured once a day for 30 days using electrochemical method and were analyzed statistically. The results were as follows : 1. The group with Super EBA cement filling showed the least marginal leakage from second to fourth day(p<0.05), there was no significant difference between the group with amalgam filling during eighth to eighteenth day(p>0.05), but after the nineteenth day here was a higher marginal leakage than the group with amalgam filling(p<0.05). 2. The group with desiccated ZOE filling demostrated that the highest marginal leakage, started on the eighth day(p<0.05). 3. The group using ultrasonic instrument showed lower marginal leakage than the group using bur until the nineteenth day(p<0.05), but there was no significant differnce with the group using bur after twentythird day(p>0.05). 4. The group without bevel showed lower marginal leakage than the group with bevel (p<0.05). 5. Whether bevel or nor had much more effect on marginal leakage than with cavity perparation instrument when the cavity was retrogrdefilled with amalgam(stepwise regression).

  • PDF

EFFECTS OF SOME RESTORATIVE MATERIALS ON THE PROLIFERATION OF OSTEOBLASTIC CELL AND THE TISSUE REACTION OF BONE (수종 수복재의 조골세포 유사세포 증식 및 골조직 반응에 미치는 영향)

  • Kim, Hyun-Sun;Hong, Chan-Ui;Kim, Jong-Yeo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.305-324
    • /
    • 1997
  • Numerous materials such as amalgam, IRM, SuperEBA, dessicated ZOE, and Ketac-Silver have been used as a root-end filling material or to repair furcation perforations. But so far no material has been found to satisfy all of the requirements of an ideal restorative material. Recently, mineral trioxide aggregate (MTA) has been suggested for use as a root end filling material and for the repair of furcation perforations. The purpose of this study was to compare the effect of MTA on the proliferation of MC3T3/E1 osteoblastic cell, formation of bone nodule, alkaline phosphatase activity, and finally the tissue reaction of bone with those of amalgam, IRM, SuperEBA, dessicated ZOE, and Ketac-Silver. The following conclusions were drawn within the limits of the experimental results : 1. MTA showed a excellent proliferation of osteoblastic cell and Ketac-Silver showed moderate proliferation of osteoblastic cell. The rest of test materials showed no proliferation of osteoblastic cell. 2. Many of definite bone nodules were found in the MTA group. In contrast, Ketac-Silver group showed no definite bone formation but only showed mild sign of bone formation. 3. Alkaline phosphatase activity of Ketac-Silver and MTA showed similar results. But both of them showed higher activity than that of other materials (p<0.005). 4. The tissue reaction to implanted MTA in the calbarium of mouse was milder than that observed with other materials. The tissue reaction of dessicated ZOE showed the worst results among the test materials.

  • PDF

AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF THE INITIAL ACIDITY OF DENTAL CEMENTS (수종 치과용 시멘트 경화시 초기 산도측정에 관한 실험적 연구)

  • Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.189-196
    • /
    • 1991
  • The purpose of this study was to observe the inital acidity of zinc phosphate cements(Confit and Super Cem), poly carboxylate cement(Unident and Poly F), zinc oxide engenol cement(Stailine Super EBA) and g1ass ionomer cement(Fuji ionomer) Each cement was manuplated in accordance with each manufacturer's direction. All cements were mixed at the room temperature of $23^{\circ}{\pm}$, $5^{\circ}C$, and the electrode of pH meter(Ionanalyzer) was inserted in the mixed cement, and the acidity of cement were measured for 20 minutes from begining of cement mixing at $23^{\circ}C$ and $37^{\circ}C$ Results were as follows 1. The acidity of all cements ranges from pH 3, 5 to 4, 5 at 2 minutes after the start of mixing 2. The value of pH at $23^{\circ}C$ was higher than the value of pH at $37^{\circ}C$ in all cements. 3. As the time elapsed, the pH in all cements rose. The 20 minutes after the start of mixing the range of acidity was from pH 5 to pH 6 except Poly F. 4. In polycarboxylate cement, the different value of acidity at $23^{\circ}C$ and $37^{\circ}C$ was greatest. 5. The curve pattern of acidity in Unident was similar to that in Poly F cement The pH value of Unident was higher then that of Poly F, and value of pH in the curve pattern of acidity in Confit were similar to those in Super cement.

  • PDF

ONE-VISIT APEXIFICATION USING MINERAL TRIOXIDE AGGREGATE (MTA를 이용한 미성숙 영구치의 즉일 치근단형성술)

  • Yeom, Soon-Joon;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.480-487
    • /
    • 2001
  • In children and adolescents, oral and maxillofacial trauma is one of the most common causes of dental and periodontal damage, which often induces crown fracture of the permanent anterior teeth. Frequently, these traumatized teeth lose their vitality, and require routine endodontic treatment if their root apices are closed. However if their apices are not fully closed, further root formation should be promoted by apexification or apexogenesis. Calcium hydroxide is a biocompatible & bacteriostatic material, and is widely used for apexification. However it has several disadvantages which include the need for multiple visits and patient cooperation, low strength and technical sensitivity in a broad apex. In one-visit apexification using IRM or SuperEBA, patient's visits can be minimized. However, their biocompatibility is questionable. Mineral trioxide aggregate(MTA) is a relatively new material. It is considered biocompatible with periapical hard tissue and has good marginal sealing ability. MTA is also known to help facillitate the growth of the cementum around it. In this case report, apexification with MTA was attempted on traumatized maxillary central incisors with immature root apices, and favorable clinical results were achieved.

  • PDF

Physical and chemical properties of experimental mixture of mineral trioxide aggregate and glass ionomer cement (Glass ionomer cement와 혼합한 mineral trioxide aggregate의 물리적 및 화학적 성질)

  • Jeong, Yu-Na;Yang, So-Young;Park, Bum-Jun;Park, Yeong-Joon;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.344-352
    • /
    • 2010
  • Objectives: The purpose of this study was to determine the setting time, compressive strength, solubility, and pH of mineral trioxide aggregate (MTA) mixed with glass ionomer cement (GIC) and to compare these properties with those of MTA, GIC, IRM, and SuperEBA. Materials and Methods: Setting time, compressive strength, and solubility were determined according to the ISO 9917 or 6876 method. The pH of the test materials was determined using a pH meter with specified electrode for solid specimen. Results: The setting time of MTA mixed with GIC was significantly shorter than that of MTA. Compressive strength of MTA mixed with GIC was significantly lower than that of other materials at all time points for 7 days. Solubility of 1 : 1 and 2 : 1 specimen from MTA mixed with GIC was significantly higher than that of other materials. Solubility of 1 : 2 specimen was similar to that of MTA. The pH of MTA mixed with GIC was 2-4 immediately after mixing and increased to 5-7 after 1 day. Conclusions: The setting time of MTA mixed with GIC was improved compared with MTA. However, other properties such as compressive strength and pH proved to be inferior to those of MTA. To be clinically feasible, further investigation is necessary to find the proper mixing ratio in order to improve the drawbacks of MTA without impairing the pre-existing advantages and to assess the biocompatibility.

COMPARISON OF ULTRASONIC AND SONIC ROOT END PREPARATIONS USING ANAEROBIC BACTERIAL LEAKAGE MODEL (ANAEROBIC BACTERIAL LEAKAGE MODEL을 이용한 음파와 초음파 치근단 와동 형성 기구에 대한 비교)

  • Cho, Nak-Yeon;Park, Dong-Sung;Yoo, Hyeon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.530-534
    • /
    • 2002
  • 최근 치근단 와동 형성 시 초음파 또는 음파 기구를 이용하는 것이 보편화되어 있고 여러 측면에서 평가되어져 왔다. 본 연구의 목적은 혐기성 세균을 이용한 미세 누출 모델을 이용하여 초음파와 음파 기구를 사용, 치근단 와동 형성을 하였을 때 두 기구의 사용이 충전된 치근단 와동의 미세 누출에 미치는 영향을 비교 평가하는 것이다. 48개의 단근치의 근관을 crown-down방법을 이용 Profile로 .06 black까지 근관 성형을 시행하고 수직 가압법을 사용하여 gutta-percha와 AH26 sealer를 이용하여 근관 충전을 시행하였다. 각 충전된 시편의 치근단 3mm를 절제하였다. 각 시편은 이미로 4군으로 나누었으며 1군에서는 치근단 와동을 초음파 기구로 형성하였고 2군에서는 음파 기구로 형성하였다. 3군은 음성대조군으로 4군은 양성대조군으로 분류하였다. 형성된 치근단 와동은 공기 분사침을 이용하여 건조 후 super EBA 시멘트로 충전하였으며 Anaerobic chamber에서 Fusobacterium nucleatum (VPI 10197)을 사용한 혐기성 세균 미세누출 모델을 이용하여 30일간 미세 누출을 관찰한 결과, 초음파 기구를 사용한 군에서는 80%에서 음파 기구를 사용한 군에서는 75%에서 미세누출이 나타났으나 통계적으로 유의성 있는 차이는 보이지 않았다.

A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS (근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구)

  • Kim, Yong-Sang;Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.107-114
    • /
    • 2008
  • This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, $Dyract^{(R)}$ AP, Super $EBA^{(R)}$, $IRM^{(R)}$, AH $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$, and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.