• Title/Summary/Keyword: Sun exposure

Search Result 1,215, Processing Time 0.033 seconds

Oxidative Stress in C100 Cells Induced by Combined Treatmentof Benzo(a)pyrene and/or 2,3,7,8-Tetrachlorodibenzo-p-dioxin(TCDD)

  • Bae, Mi-Ok;Choi, Kyung-Ho;Lee, Hu-Jang;Kim, Hyun-Woo;Kim, Jun-Sung;Hwang, Soon-Kyung;Park, Jin-Hong;Cho, Hyun-Sun;Cho, Myung-Haing
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.3
    • /
    • pp.379-387
    • /
    • 2004
  • When an organism is exposed to various toxicants chronically, reactive oxygen species(ROS) are accumulated and eventually result in several biological effects from gene expression to cell death. In the present study we investigated the oxidative damage of 2, 3, 7, 8-tetrachlorodibenzo-p-dioxin(TCDD) and/or benzo(a)pyrene (B(a)P) in C100 cells. C100 cells treated with TCDD(30 nM) and B(a)P($3{\mu}M$) underwent diverse oxidative stress as determined through thiobarbituric acid-reactive substances(TBARS) formation, DNA fragmentation, DNA single strand break(SSB) assay, immunohistochemical staining of 8-hydroxy-2'-deoxyguanosine(8-OHdG), and mRNA expressions of antioxidant enzymatic genes such as Cu/Zn-SOD gene, GPx(glutathione peroxidase 5) gene, and catalase gene. Lipid peroxidation in C100 cells was determined through measuing the formation of TBARS. For theat, the cells were pretreated with TCDD(30 nM) and/or B(a)P($3{\mu}M$) for 0.5, 1, 2 and 4 days. TBARS formation was increased in TCDD(30 nM) and B(a)P($3{\mu}M$) and mixture($30nM\;TCDD+3{\mu}M\;B(a)P$) and positive control treatment groups comparing to the controls. Mixture treatment induced more DNA fragmentation than the single treatment group at day 6. Also, SSB in all treatment groups was clearly observed when compared with the negative control group. As with the expression of antioxidant enzyme, GPx 5mRNA, B(a)P alone and mixture($30nM\;TCDD+3{\mu}M\;B(a)P$) treatment were higher comparing to those of the negative control and TCDD treatment groups. Our results suggest that exposure of C100 cells to mixture of TCDD and B(a)P leads to significant oxidative damage comparing to the exposures to the individual chemicals. Mechanisms of action are discussed. Additional studies are needed to elucidate the detailed mechanism of mixture-induced toxicity.

Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program (Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석)

  • Kim, Young-Eun;Lee, Jeong-Hwa;Hong, Sun-Suk;Lee, Kwan-Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF

Corrosion Behavior of $Y_2O_3$ Coating in an Electrolytic Reduction Process (전해환원공정에서 $Y_2O_2$ 코팅층의 부식거동)

  • Cho, Soo-Haeng;Hong, Sun-Seok;Kang, Dae-Seung;Jeong, Myeong-Soo;Park, Byung-Heong;Hur, Jin-Mok;Lee, Han-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.1
    • /
    • pp.33-39
    • /
    • 2010
  • The electrolytic reduction of a spent oxide fuel involves a liberation of the oxygen in a molten LiCl electrolyte, which results in a chemically aggressive environment that is too corrosive for typical structural materials. Accordingly, it is essential to choose the optimum material for the processing equipment that handles the high molten salt. In this study, hot corrosion studies were performed on bare as well as coated superalloy specimens after exposure to lithium molten salt at $675^{\circ}C$ for 216 h under an oxidizing atmosphere. The IN713LC superalloy specimens were sprayed with an aluminized NiCrAlY bond coat and then with an $Y_2O_3$ top coat. The bare superalloy reveals an obvious weight loss due to spalling of the scale by the rapid scale growth and thermal stress. The chemical and thermal stability of the top coat has been found to be beneficial for increasing to the corrosion resistance of the structural materials for handling high temperature lithium molten salts.

The Effect of Cream containing Acetyl hexapeptide upon the Facial Skin (Acetyl hexapeptide 함유 크림이 안면 피부 변화에 미치는 영향)

  • Choi, Jeong-Yun;Oh, Sung-Cheon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.120-129
    • /
    • 2014
  • The structure and physiological function of human skin continuously weaken due to growing older. The reasons of aging from external conditions are long term exposure to sun, wind, heat, cigarette smoke, and etc. This also palmitoyl oligopeptide or ceramide oligopeptide are known asc ingredient stimulating collagens and have the effect of reproducing the upper level of skin. Acetyl hexapeptide is an ingredient that makes the skin and muscle suppler and reduces wrinkles. It is a major high function beauty ingredient that substitutes botox. After dividing 7%, 14%, and 20% Acetyl hexapeptide experimental groups as groups A, B, and C the control group and experiment groups' change of wrinkles, hair follicles, moisture content, and dead skin cells was analyzed. According to the results, Acetyl hexapeptide seems to affect wrinkles, hair follicles and moisture content contrasting to the control group. Experimental groups and control group showed similar change in dead skin cells. In contrast to the control group satisfaction of examines was affected in wrinkles, hair follicles and moisture but removing dead skin cells had similar result in experimental groups and control group.

Psychosocial Interventions for Children and Adolescents after a Disaster: A Systematic Literature Review (1991-2015) (재난 후 소아청소년의 정신사회적 개입: 체계적 문헌고찰(1991~2015))

  • Lee, Mi-Sun;Hwang, Jun-Won;Lee, Cheol-Soon;Kim, Ji-Youn;Lee, Ju-Hyun;Kim, Eunji;Chang, Hyoung Yoon;Bae, Seung-Min;Park, Jang-Ho;Bhang, Soo-Young
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.27 no.4
    • /
    • pp.278-305
    • /
    • 2016
  • Objective: The aim of this systematic literature review is to analyze the psychosocial interventions for children and adolescents after disasters. Methods: We conducted a review of the extant research literature from 1991 to 2015 via a comprehensive search of the MEDLINE, EMBASE, Cochrane CENTRAL, PubMed and PsyclNFO databases. The keywords employed in this research included: 'child', 'adolescent', 'youth', 'disaster', 'posttraumatic', 'psychosocial', 'therapy' and 'intervention'. The researchers followed the PRISMA guidelines. A total of 850 articles were screened for their eligibility and fifty-nine were found to meet the study criteria. The final data analysis was performed based on the disaster type, study design, type of intervention, sample size, age, school grade, number of sessions, setting of intervention delivery, providers, approach and parent involvement. Results: Countries worldwide have experienced various kinds of disasters, including earthquakes, hurricanes, vessel accidents, tornados, tsunamis, volcanic eruptions, war, fire, terrorism, and traffic accidents. The types of psychosocial intervention that were conducted after these disasters included: psychological first aid, psychological debriefing, psychoeducation, trauma focused cognitive behavior therapy, eye movement desensitization reprocessing, prolonged exposure therapy, group play therapy and arts therapy, project interventions, school-based interventions and web-based interventions. Conclusion: The findings of the systematic literature review suggest that an appropriate psychosocial intervention could be utilized as evidence-based mental health treatment for children and adolescents after disasters.

Development of Automatized Quantitative Analysis Method in CT Images Evaluation using AAPM Phantom (AAPM Phantom을 이용한 CT 영상 평가 시 자동화된 정량적 분석 방법 개발)

  • Noh, Sung Sun;Um, Hyo Sik;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.163-173
    • /
    • 2014
  • When evaluating the spatial resolution images and evaluation of low contrast resolution using CT standard phantom, and might present a automated quantitative evaluation method for minimizing errors by subjective judgment of the evaluator be, and try to evaluate the usefulness. 120kVp and 250mAs, 10mm collimation, SFOV(scan field of view) of 25cm or more than, exposure conditions DFOV(display field of view) of 25cm, and were evaluated the 24 passing images and 20 failing images taken using a standard reconstruction algorithm by using the Nuclear Associates, Inc. AAPM CT Performance Phantom(Model 76-410). Quantitative evaluation of low contrast resolution and spatial resolution was using an evaluation program that was self-developed using the company Mathwork Matlab(Ver. 7.6. (R2008a)) software. In this study, the results were evaluated using the evaluation program that was self-developed in the evaluation of images using CT standard phantom, it was possible to evaluate an objective numerical qualitative evaluation item. First, if the contrast resolution, if EI is 0.50, 0.51, 0.52, 0.53, as a result of evaluating quantitatively the results were evaluated qualitatively match. Second, if CNR is -0.0018~-0.0010, as a result of evaluating quantitatively the results were evaluated qualitatively match. Third, if the spatial resolution, as a result of using a image segmentation technique, and automatically extract the contour boundary of the hole, as a result of evaluating quantitatively the results were evaluated qualitatively match.

Effect of retinoic acid on the radiosensitivity of normal human oral keratinocyte (Retinoic acid가 사람 정상 구강각화세포의 방사선감수성에 미치는 영향에 관한 연구)

  • Lee Jean;Heo Min-Suk;Lee Sam-Sun;Oh Sung-Ook;Lee Sul-Mi;Choi Hang-Moon;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.97-105
    • /
    • 2003
  • Purpose : To evaluate the effect of all-trans-retinoic acid (ATRA) on the radiosensitivity of normal human oral keratinocyte (NHOK). Materials and methods: Relative cell survival fraction including SF2 (survival fraction at 2 Gy) was calculated on the basis of colony formation assay. Data were fitted to the linear-quadratic model to establish the survival curve and calculate α and β values. Using flow cytometry at 1, 2, 3, 4, and 5 days after exposure to 2 and 10 Gy irradiation, cell cycle arrest and apoptosis were analysed. To understand the molecular mechanism of the radiosensitization of ATRA on NHOK, proteins related with apoptosis and cell cycle arrest were investigated by Western blot analysis. Results: Treatment with ATRA resulted in a significant decrease of SF2 value for NHOK from 0.63 to 0.27, and increased α and β value, indicating that ATRA increased radiosensitivity of NHOK. ATRA increased LDH significantly, but increasing irradiation dose decreased LDH, suggesting that the radiosensitizing effect of ATRA is not directly related with increasing cell necrosis by ATRA. ATRA did not induce appotosis but increased G2 arrest after 10 Gy irradiation, implying that the increased radiosensitivity of NHOK may be due to a decrease in mitosis casued by increasing G2 arrest. ATRA inhibited the reduction of p53 at 3 days after l0Gy irradiation and increased p21 at 1 day after 10 Gy irradiation. Further study is required to determine the precise relationship between this effect and the radiosensitizing effect of A TRA. Conclusion: These results suggested that ATRA increase radiosensitivity by inhibiting mitosis caused by increasing G2 arrest.

  • PDF

A dose monitoring system for dental radiography

  • Lee, Chena;Lee, Sam-Sun;Kim, Jo-Eun;Symkhampha, Khanthaly;Lee, Woo-Jin;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Yeom, Heon-Young
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

Radiopacity of contemporary luting cements using conventional and digital radiography

  • An, Seo-Young;An, Chang-Hyeon;Choi, Karp-Sik;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.97-101
    • /
    • 2018
  • Purpose: This study evaluated the radiopacity of contemporary luting cements using conventional and digital radiography. Materials and Methods: Disc specimens (N=24, n=6 per group, ø$7mm{\times}1mm$) were prepared using 4 resin-based luting cements (Duolink, Multilink N, Panavia F 2.0, and U-cem). The specimens were radiographed using films, a complementary metal oxide semiconductor (CMOS) sensor, and a photostimulable phosphor plate (PSP) with a 10-step aluminum step wedge (1 mm incremental steps) and a 1-mm-thick tooth cut. The settings were 70 kVp, 4 mA, and 30 cm, with an exposure time of 0.2 s for the films and 0.1 s for the CMOS sensor and PSP. The films were scanned using a scanner. The radiopacity of the luting cements and tooth was measured using a densitometer for the film and NIH ImageJ software for the images obtained from the CMOS sensor, PSP, and scanned films. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: Multilink (3.44-4.33) showed the highest radiopacity, followed by U-cem (1.81-2.88), Panavia F 2.0 (1.51-2.69), and Duolink (1.48-2.59). The $R^2$ values of the optical density of the aluminum step wedge were 0.9923 for the films, 0.9989 for the PSP, 0.9986 for the scanned films, and 0.9266 for the CMOS sensor in the linear regression models. Conclusion: The radiopacities of the luting materials were greater than those of aluminum or dentin at the same thickness. PSP is recommended as a detector for radiopacity measurements because of its accuracy and convenience.

Bone formation of newly developed biphasic calcium phosphate in rabbit calvarial defect model : A pilot study (토끼 두개골에서 새로 개발된 biphasic calcium phosphate의 골형성 효과 : A pilot study)

  • Um, Yoo-Jung;Hong, Ji-Yeon;Kim, Sung-Tae;Lee, Yong-Ho;Park, Sang-Hyun;Park, Sun-Hyo;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.163-170
    • /
    • 2008
  • Purpose: Biphasic calcium phosphates have been of great interest recently. Mixing adequate ratios of hydroxyapatite(HA) and beta-tricalcium phosphate($\beta$-TCP) allowed to control the resorption rate without distorting its osteoconductive property. This study evaluated the bone formation effect of newly developed biphasic calcium phosphate(BCP) in calvarial defect of rabbits. Materials and Methods: 6 male New Zealand rabbits were used. Four defects with 8mm in diameter were created on each animal. BCP with HA/$\beta$-TCP ratio of 7:3 and particle size of $0.5{\sim}1.0\;mm$ was used as the test group and bovine bone with $0.25{\sim}1.0\;mm$ particle size, as the control group. Both test and control group materials were randomly implanted in the calvarial defects and were covered witha polymer membrane. The animals were sacrificed after 12, 24, and 48 weeks of implantation under general euthanasia. Resin blocks were obtained and were stained by masson's trichrome for histological observation. Results: Overall results were uneventful without any defect exposure or inflammation. The amount of new bone formation and bone maturity increased with increase in healing period at both groups. New bone in test group was mostly formed along the material particle surrounded by osteoblasts, and observation of osteoblastic stream was also present. Bone maturity increased as it was closer to thedefect margins. Under the same healing period, the test group showed more bone formation than the control group with more stable bovine bone particles remaining even after 48 weeks, whereas considerable resorption took place in BCP. Almost total defect closure was observed in test group with new bone formation in the central part of the defect. However, limited new bone formation was observed in the control group. Conclusion: Within the limits of the study, the present study reveals the newly developed BCP to be a good osteoconductive material. However, further studies are needed to be conducted in a different study model with a larger sample size.