• 제목/요약/키워드: Sun: radio radiation

검색결과 39건 처리시간 0.024초

암세포 내로의 약물 전달 증진 목적의 신규 소마토스타틴 수용체 타겟리간드 합성 및 평가 (Synthesis and Evaluation of a Ligand Targeting the Somatostatin Receptor for Drug Delivery to Tumor Cell)

  • 최선주;홍영돈;이소영;정성희
    • 방사선산업학회지
    • /
    • 제9권4호
    • /
    • pp.193-198
    • /
    • 2015
  • Most of targeted therapies block the action of certain enzymes, proteins, or other molecules involved in the growth and spread of cancer cells to produce its cytotoxic effect. Either small molecule drugs or monoclonal antibodies are mostly used in targeted therapies. Unfortunately, targeted therapy has a certain degree of unwanted side effect like other cytotoxicity inducing chemotherapies. To overcome and to reduce unwanted side effects during a cancer therapy, recently radiopeptide therapies has got the worlds' attraction for the tumor targeting modalities due to its beneficial effect on less side effect compared to cytotoxic chemotherapies. Among radiopeptide therapies, $^{177}Lu$-DOTATATE is a major modality as an effective one invented so far in treating neuroendocrine tumor (NET) and it has been in clinical trials at least one decade. Although it does have rather effective therapeutic effect on NET, it has less effective in rather large solid tumor. There are many ways to improve or increase therapeutic effect of radiopeptide are a finding the potent small molecules to target the tumor site selectively, or a labeling with radioisotope of emitting high energy, or an improving its biological half-life by introducing different moieties to increase lipophilicity. Present study was focus to increase a biological half-life of radio somatostatin which will target the somatostatin receptor by altering the bifunctional chelator (BFCA) by introducing lipophilic moiety to the somatostatin, which would make the labeled peptide stay longer in the tumor site and thus it can intensify the therapeutic effect on tumor cell itself and around tissues.

인공위성 탑재용 소형 극자외선 태양망원경 공학 모형 설계 (DESIGNING A SMALL-SIZED ENGINEERING MODEL OF SOLAR EUV TELESCOPE FOR A KOREAN SATELLITE)

  • 한정훈;장민환;김상준
    • Journal of Astronomy and Space Sciences
    • /
    • 제18권2호
    • /
    • pp.145-152
    • /
    • 2001
  • 태양의 극자외선 복사를 연구하기 위한 인공위성 탑재용 소형 극자외선 태양망원경의 공학 모형을 설계하였다. 극자외선 태양망원경은 $584.3AA$(He I)과 $629.7AA$(OV)의 두 파장대역에서 태양을 관측하기 위한 목적으로 설계되었다. 광학계는 Ritchey-Chr 샤두 방식이고, 망원경의 유효구경과 유효 초점 거리는 각각 80mm, 640mm이다. 회전 필터 휠을 사용하여 He I과 OV 방출선을 관측할 수 있도록 하였다. 검출기의 MCP (Microchannel Plate)는 채널 길이 대 직경의 비가 40:1인 Z-stack 타입이고, photocathode로서 KBr이 MCP 초점면에 코팅되며, MCP와 CCD는 fiber optic taper로 연결되도록 디자인하였다. 광학계 설계에 대한 분석은 광학계산용 상용 소프트웨어를 이용하였다.

  • PDF

RFID를 이용한 개선된 실내 위치 추적 (Advanced Indoor Location Tracking Using RFID)

  • 주원이;김효선;정영아;홍연찬
    • 한국산학기술학회논문지
    • /
    • 제18권1호
    • /
    • pp.425-430
    • /
    • 2017
  • RFID는 무선 주파수를 이용하여 사물 또는 사람에 부착된 태그의 정보를 읽어내는 기술이다. 비접촉 방식으로 위치를 추적하는 RFID 시스템에서 태그를 이용하여 위치를 추적할 때 실제의 위치와 측정된 위치 간의 오차가 발생한다. 본 논문에서는 RFID 기술을 통한 사물 또는 사람의 위치를 파악하는 방법에 있어 3가지 방법을 제안한다. RFID기반의 위치 인식시스템을 구성하고 태그(tag)들을 정사각형 형태로 배치한다. 리더(reader)를 보유한 물체의 실제위치와 실험을 통해 예상되는 물체의 위치를 비교하여 오차를 확인한다. 기존 논문에서는 리더에 읽힌 모든 tag들의 무게중심 값을 구하여 리더의 대략적인 위치를 구하였다면 본 논문에서는 중점과 방사원의 형태를 이용하여 예상위치를 구하는 3가지 방법을 추가적으로 제시하는데 첫 번째는 중간 값을 사용한 방법, 두 번째는 방사 형태를 사용한 방법, 세 번째는 원과 중간 값을 절충한 방법을 사용하였다. 데이터를 통해 본 논문에서 제안된 4가지 방법 중 어떤 방법이 거리의 오차가 적어 실제 위치를 추적하는 데에 효율적인지 확인하고자 한다. 그 결과 방사형태, 중앙 값, 그리고 방사형태와 중앙 값 두 가지를 모두 이용한 방법 중 중앙 값 만을 이용한 계산 방법이 가장 적은 오차가 발생하였다.

고주파 온열치료시 케모포트의 열적 변화 연구 (The study of thermal change by chemoport in radiofrequency hyperthermia)

  • 이승훈;이선영;김양수;;양명식;차석용
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.97-106
    • /
    • 2015
  • 목 적 : 고주파 온열치료 시 약물투여 및 혈액채취에 사용되는 케모포트로 인한 열적 변화를 알아보고자 한다. 대상 및 방법 : 전극 크기 20 cm인 고주파 온열치료기(EHY-2000, Oncotherm Kft, Hungary)를 이용하여 현재 본원에서 사용 중인 케모포트 중 재질이 플라스틱인 소재, 티타늄을 둘러싼 에폭시 소재와 티타늄 소재 케모포트를 자체 제작한 직경 20 cm, 높이 20 cm 원통형 한천(Agar)팬텀에 삽입하여 온도를 측정하였다. 온도측정기(TM-100, Oncotherm Kft, Hungary) 그리고 Sim4Life(Ver2.0, ZMT, Zurich, Switzerland) 프로그램을 사용하여 실제 측정된 온도변화와 비교 분석하였다. 측정위치는 전극 중심축 및 중심축 측면 1.5 cm지점에 각각 0 cm(표면), 0.5 cm, 1.8 cm, 2.8 cm 깊이별로 하였다. 측정조건은 온도 $24.5{\sim}25.5^{\circ}C$, 습도 30 ~ 32%, 출력 전력 100 W로 5분 간격으로 총 60분을 측정 하였다. 결 과 : 케모포트 미사용, 플라스틱, 에폭시 그리고 티타늄 케모포트를 사용한 경우의 최고온도는 전극 중심축 2.8 cm 깊이에서 측정값 $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$와 모의실험값 $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$이며, 전극 중심축 1.5 cm 측면 2.8 cm 깊이에서 측정값 $39.51^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$와 모의실험값 $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$이다. 고안 및 결론 : 고주파 전자기장에 의한 케모포트 주위의 열적 변화량은 부도체 물질인 플라스틱과 에폭시 소재에서 미사용의 경우보다 낮게 나타났으며, 도체 물질인 티타늄 케모포트에서는 약간의 차이를 보였다. 이는 케모포트내 금속 함유량 및 기하학적 구조에 의한 것과 이용 장비의 낮은 고주파 대역를 사용함에 있는 것으로 여겨진다. 즉 본 연구에 사용된 케모포트는 열 변화가 미미하여 장해를 고려하지 않아도 된다고 사료된다.

  • PDF

두경부 종양의 방사선 치료 성적 (Radical Radiotherapy of Head and Neck Cancer)

  • 반성범;김철영;최명선;서원혁
    • Radiation Oncology Journal
    • /
    • 제4권1호
    • /
    • pp.35-43
    • /
    • 1986
  • 1981년 3월부터 1986년 3월까지 고려대학교 의료원 혜화병원 치료방사선과에서 60명의 두경부 환자를 대상으로 방사선치료후의 임상적인 병기에 따른 생존율 및 국소종양 억제율을 후향적으로 재조사하였다. 근치적 방사선 치료전에, 이학적 검사와 방사선학적 검사로 흉부X-선, 후두촬영 및 콤퓨터 단층촬영 등을 시행하였고 AJC의 임상병기에 따라 분류하였다. 치료는 방사선 치료 단독 시, 7,200cGy를 8주에, 그리고 수술후 방사선 치료시는 6,000cGy를 7주에 각각 분할 조사하였다. 이에 저지들은 다음과 같은 결과를 얻었다. 1) 남녀의 성비는 3.6:1이었고 50대의 연령군에서 가장 높은 빈도를 보였다. 2) 방사선 치료를 받은 환자에서, 병리조직하적으로 편평상피암이 비 편평상피암에 비해 3.5배의 높은 빈도를 보였다. 3) 원발병소의 해부학적 위치는 후두가 22예, 부비동이 12예, 비인후강이 7예, 구강인두가 6예, 하인두가 3예였다. 4) AJC의 병기에 따라 분류하면 I기가 4예, II기가 7예, III기가 19예, 그리고 IV기가 27예였다. 5) 경부임파절로의 국소전이는 전체적으로 $43\%$였고 subdigastric과 submaxillary임파절이 가장 않은 것으로 나타났다. 6) 방사선 치료 후 국소종양의 억제는 치료 환자의 $48\%$에서 관찰되었다. 7) 원격전치는 7예에서 관찰되었는데 그중 4예에선 폐로의 원격전이를 보였다. 8) Life-table방식에 의한 5년 생존율은 $43\%$로 나타났다.

  • PDF

THE SWINGS EFFECTS OF THE A-X SYSTEM AND v''= 1-0 BAND OF CO

  • KIM SANG-JOON
    • 천문학회지
    • /
    • 제29권2호
    • /
    • pp.223-243
    • /
    • 1996
  • We have constructed a line-by-line model of the A-X system of CO in order to analyze the CO bands appearing in the UV spectra of comets. The model includes electronic, rotational, vibrational transitions, excitations by solar UV radiation, and effects of neutral and electron collisions. The major bands of the A-X system occur in the $1200 - 1800{\AA}$ range where the temporal variation of solar irradiation is significant. The solar spectrum in this spectral range shows many emission lines, which cause a significant Swings effect. We derived fluorescence efficiencies of the bands as functions of heliocentric velocity and cometocentric distance using a high resolution spectrum of the sun. We compared our model with a spectrum of comet P/Halley obtained with the IUE, and estimated that the UV Swings effects are less than 20 fluorescence efficiencies for the most bands of the A-X system. We discuss the temporal variation of solar UV irradiation and its effects on the fluorescence efficiencies. The study of the A-X system also requites knowledge of vibrational and rotational fluorescent processes in the infrared and radio regions because the majority of CO molecules in the coma is in the ground rotational states. The solar infrared spectrum near 5 microns, where the fundamental band of CO occurs, contains strong absorption lines of the fundamental band and hot bands of CO and its isotopes. We derived fluorescence efficiencies of the infrared band as functions of heliocentric velocity and cometrocentric distance. The solar absorption lines near 5 microns cause a 20 reduction of the g-factor of the fundamental band at heliocentric velocities close to 0 km/sec. We discuss the effects of neutral and electron collisions on the fluorescence efficiencies of the infrared and UV bands.

  • PDF

디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 - (A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo)

  • 조광호;강영한;김부순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.177-182
    • /
    • 2008
  • 디지털 시스템이 가지는 장점인 영상판 검출기의 반응 범위(dynamic range)가 상당히 넓다는 것은 필름/증감지 시스템보다 더 높은 수준의 노광 관용도를 갖기에 재촬영이 줄어들고 영상관리에 효율적이지만, 조사조건의 설정범위가 상당히 넓어 필름/증감지 시스템의 엄격한 조사조건보다 더 많은 조사선량이 환자에게 노출 될 수도 있다. 본 연구는 디지털 시스템 하에서 일반촬영 시 방사선사 개인 별 조사선량에 대한 인식과 행위실태를 파악하여 환자피폭선량을 감소시킬 수 있는 방안을 마련하고, 방사선 선량관리의 중요성을 새로이 인식하고자 하였다. 디지털 시스템 하에서 근무 중인 방사선사의 조사조건 설정과 환자피폭선량 인지 실태를 파악해 본 결과 환자의 체형이나 상태, 촬영부위에 따라 최적의 조사선량을 적용하기 보다는 영상의 농도와 업무의 편의성에 따라 조사조건이 설정되고 있었다. 디지털 시스템이 도입되며 검출기의 반응 범위가 필름/스크린 시스템보다 넓어짐에 따라 조사조건 설정에 대해 관심이 소홀한 경향이 있었다. 따라서 디지털 방사선 시스템 하에서 환자 피폭선량의 감소를 위해 최적의 조사조건으로 영상을 얻어야 할 것이다. 또한 조사선량을 최소로 하고 환자 피폭선량을 줄이기 위해 업무 습관과 인식을 새로이 할 필요성이 있고, 지속적인 관심과 주기적인 교육 및 점검, 다양한 교육 기회제공 등이 필요하다고 본다.

  • PDF

조기 유방암에서 보존적 수술후 방사선치료성적 (The Results of Primary Radiotherapy following Breast-Conserving Surgery for Early Breast Cancer)

  • 고경환;김미숙;류성렬;조철구;김재영;김용구;문난모;백남선;이종인;최동욱
    • Radiation Oncology Journal
    • /
    • 제13권2호
    • /
    • pp.163-171
    • /
    • 1995
  • 목적: 조기 유방암에서 보존적 수술후 방사선치료는 외국에서 과거 20여년 동안 근치적 수술과 비슷한 생존율을 보였다. 그러나 아직 우리 나라에서는 보편화되지는 못한 실정이다. 이 논문은 원자력병원에서 시행한 조기 유방암환자에서 보존적 수술의 성적 및 부작용의 결과를 알기 위함이다. 방법: 1987년 1월부터 1989년 12월까지 원자력 병원 치료방사선과에서 보존적 수술후 방사선치료를 받은 조기 유방암 환자 45명에 대해 후향적 연구를 시행하였다. 추적 관찰기간은 4-82개월이었고 중앙값은 54개월이었다. 수술은 조직 생검만 시행한 경우 및 Tumorectomy 또는 Quadrantectomy를 시행한 경우가 있었다. 28예에서 액와림프절 박리를 시행하였다. 방사선 치료는 전유방에 Tangential field로 하루 1.8-2 Gy씩 총 50 또는 50.4 Gy를 조사하였다. 항암 요법은 30예의 환자에서 시행되었고 호르몬 치료는 11예에서 시행되었다. 결과: 5년 생존율, 5년 무병생존율 및 5년 국소제어율은 각각 87.2%, 86.5%, 및 97.6%였다. 전신 요법을 시행하는 군이 시행하지 않은 군에 비하여 5년 생존율에서 좋은 성적을 보였으나 통계학적인 의미는 없었다 (0.05

  • PDF

홀뮴 및 홀뮴-키토산 복합체가 정상 백서 뇌에 미치는 효과에 대한 연구 (Effects of 166Holmium and 166Holmium-chitosan Complex(166Ho-CHICO) on Normal Brain of Rats)

  • 손경화;조철우;안영환;박찬희;심철;박경배;조경기
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권10호
    • /
    • pp.1309-1315
    • /
    • 2000
  • Objectives : We performed an in vivo experiment to investigate the effect of $^{166}Holmium$ and $^{166}Holmium$-chitosan complex($^{166}Ho$-CHICO) on the normal brain of rats and to determine the sublethal dose of $^{166}Ho$-CHICO. Materials and Methods : $^{166}Ho$ is a beta and gamma ray emitter. $^{166}Ho$-CHICO is a novel radio-pharmaceutical complex with chitosan to facilitate the transport of $^{166}Ho$ obtained from Korea Atomic Energy Research Center(Taejon, Korea). It is in acidic form and becomes gel state at alkaline pH. One hundred and seventy consecutive rats were divided into four groups : $^{166}Ho$ treated(n=50), $^{166}Ho$-CHICO treated(n=57), saline treated(n=5) and chitosan treated(n=5) groups. $^{166}Ho$ and $^{166}Ho$-CHICO were injected into the rat brain stereotactically with various doses of 0.1mCi/$20{\mu}l$, 0.2mCi/$20{\mu}l$, 0.3mCi/$20{\mu}l$, and 0.4mCi/$20{\mu}l$ using an automated microinjector. Nuclear imaging, histopathological and hematological studies were performed in 10 rats in each group at 1 day, 3days, 7 days, 1 month and 3 months after the injections. Results : An infiltration of inflammatory cells and necrotic changes were noted in $^{166}Ho$ treated group at 1 week after the injection. A wedge-shaped tissue defect due to necrosis, lined with infiltrated glial cells in $^{166}Ho$ treated group and a cystic defect lined with reactive astroglial cells in $^{166}Holmium$-CHICO treated group at 3 months after the injection were observed. $^{166}Ho$ alone without chitosan leaked out and caused necrotic lesion on the cerebral surface but $^{166}Holmium$-CHICO treated group did not show this feature. As the dose of $^{166}Ho$ increased, the mortality rates were also increased. The mortality rate of the $^{166}Holmium$-CHICO group was higher than the $^{166}Ho$ treated group at a dose of 0.4mCi/$20{\mu}l$/300g. There was no detectable radioactivity due to the leakage or extravasation from the injected site of the brain on the scintigraphy performed at 1 hour, 24 hours and 48 hours after the injection. There was also no detectable activity of $^{166}Holmium$-CHICO in other organs including spleen, liver and kidney. Conclusions : $^{166}Ho$-CHICO did not leak out to the critical cortical surface of the brain from the injection site and induced radiation changes of the parenchyma around the injection site without cortical damage. The sublethal dose of $^{166}Ho$-CHICO for the normal brain in rats was determined to be 0.2mCi/$20{\mu}l$/300g.

  • PDF