• Title/Summary/Keyword: Sulfur particle

Search Result 95, Processing Time 0.024 seconds

A Study on the Application Limestone Sludge to the Flue Gas Desulfurization Process (제철 산업부산물인 석회석 슬러지의 배연탈황 공정 적용에 관한 연구)

  • Seo, Sung Kwan;Chu, Yong Sik;Shim, Kwang Bo;Lee, Jong Kyu;Song, Hun;Yun, Young Min
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.6
    • /
    • pp.575-583
    • /
    • 2014
  • The flue gas desulfurization (FGD) process is currently the most effective process utilized to remove sulfur dioxide from stack gases of coal-fired plants. However, FGD systems use a lot of limestone as desulfurizing agent. In this study, we use limestone sludge, which is a by-product of the steel industry, to replace the desulfurizing agent of the FGD system. The limestone particle size is found to be unrelated to the desulfurizing rate; the gypsum purity, however, is related. Limestone sludge mixes with limestone slurry delivered at a constant rate in a desulfurizing agent with organic acid are expected to lead to a high desulfurization efficiency and high quality by-product (gypsum).

Optimization of the Gas-Gas Heater Element for Desulfurization Equipment through Fluid Analysis of considering Deposition Particles (침적 입자를 고려한 유동해석을 통한 신형 탈황설비용 GGH 요소 최적화)

  • Oh, B.J.;Ryu, B.J.;Lee, Y.S.;Kim, J.H.;Baek, S.G.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.7
    • /
    • pp.611-619
    • /
    • 2010
  • The paper deals with the proper design of GGH(gas-gas heater) panel elements of desulfurization equipments in a thermoelectric power plant. When fossil fuels such as coal, petroleum et cetera are burnt to ashes, sulfur oxide compounds are produced, and calcareous sludges are deposited at GGH panel elements. In this case, operation of a power plant equipments is interrupted, and a tremendous economic loss comes into existence. One of the purposes of the paper is to find flow velocity distributions and regions of depositions when calcareous sludges pile up on the GGH panel elements through the fluid analysis. In the fluid analysis, flow velocity and position distributions of particles between GGH panel elements are demonstrated according to time variation for ammonia and calcium hydroxide particles.

Synthesis of Sodium ${\alpha}$-Sulfo Fatty Acid Allyl Ester Oligomer and Didpersion Stability of Pigments in Aqueous Solution ((${\alpha}$-술폰 지방산 알릴에스테르 올리고머의 합성 및 안료 분산성)

  • Lee, Hyang-Woo;Kwon, Soon-Il;Nam, Ki-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.60-66
    • /
    • 2001
  • Allylaliphatic carboxylate oligomers were prepared from polymerization giving allyl aliphatic carboxylates in the presence of potassium persulfate in methanol and the ${\alpha}-sulfonation$ of these allyl aliphatic carboxylates oligomers were carried by direct addition of dry sulfur trioxide. The dispersing performance of oligomer type anionic surfactants and SDS in the aqueous suspension of $Fe_{2}O_{3}$ and $Tio_{2}$ particles were evaluated by particle size distribution and ${\zeta}-potential$ measurement. As results, the particles of $Fe_{2}O_{3}$ and $Tio_{2}$ were flocculated by addition of small amount of oligomer type anionic surfactants and SDS, then the flocks redispersed by more addition oligomer type anionic surfactants and SDS. The dispersion and flocculation were observed in lower concentration range of oligomer type anionic surfactants than SDS.

A Study on SOx Emission Characteristics in Coal Combustion (석탄 연소시 SOx 배출 특성에 관한 연구)

  • Kang, Youn Suk;Kim, Sung Su;Lee, Hyun Dong;Kim, Jae-Kwan;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.219-223
    • /
    • 2011
  • The characteristics of SOx emission were investigated using SM (India) coal and Berau, C&A (Austria) coal. Experiments were performed in two different ways. In the first type of experiment, the temperature in the furnace was increased and the, samples were combusted at the ignition temperature after filling the furnace with coal. The second experimental method was to add the coal to after maintaining a constant temperature. The results demonstrated that SOx emission from coal combustion depended upon the sulfur content. In the case of Berau coal and C&A coal, an enhancement of combustibility which was accomplished by increasing the combustion temperature, an increase in airflow and decrease in particle size of coals tended to increase $SO_2$ generation. Conversely, in the case of SM coal, the concentration of $SO_2$ tended to decrease, because the high contents of $Fe_2O_3$ in the ashes increased the oxidation power of coal itself, which oxidized $SO_2$ into $SO_3$. In the case of C&A coal, the $SO_2$ peak was only observed twice. This was thought to be caused by the thermal transfer rate from the surface to the interior of the coal.

Characteristics of Metallic and Ionic Concentration in Fine Particle during Haze Days in Busan (부산 지역 연무 발생일의 미세먼지 중 금속과 이온 성분 농도 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.26 no.6
    • /
    • pp.767-778
    • /
    • 2017
  • This research investigates the characteristics of metallic and ionic elements in $PM_{10}$ and $PM_{2.5}$ on haze day and non-haze day in Busan. $PM_{10}$ concentration on haze day and non-haze day were 85.75 and $33.52{\mu}g/m^3$, respectively, and $PM_{2.5}$ on haze day and non-haze day were 68.24 and $23.86{\mu}g/m^3$, respectively. Contribution rate of total inorganic water-soluble ion to $PM_{10}$ mass on haze day and non haze day were 58.2% and 61.5%, respectively, and contribution rate of total water-soluble ion to $PM_{2.5}$ mass on haze day and non haze day were 58.7% and 64.7%, respectively. Also, contribution rate of secondary ion to $PM_{10}$ mass on haze day and non haze day were 52.1% and 47.5%, respectively, and contribution rate of secondary ion to $PM_{2.5}$ mass on haze day and non haze day were 54.4% and 53.6%, respectively. AC (anion equivalents)/CE (cation equivalents) ratio of $PM_{10}$ mass on haze day and non haze day were 1.09 and 1.0, respectively, and AC/CE ratios of $PM_{2.5}$ mass on haze day and non haze day were 1.12 and 1.04, respectively. Also, SOR (Sulfur Oxidation Ratio) of $PM_{10}$ mass on haze day and non haze day were 0.32 and 0.17, respectively, and SOR of $PM_{2.5}$ on haze day and non haze day were 0.30 and 0.15, respectively. Lastly, NOR (Nitrogen Oxidation Ratio) of $PM_{10}$ on haze day and non haze day were 0.17 and 0.08, respectively, and NOR of $PM_{2.5}$ on haze day and non haze day were 0.13 and 0.06, respectively.

Identification of Long-Range Transported Air Pollution Indicators over Northeast Asia (동북아시아 대기오염물질의 장거리 이동 지시자 선정 연구)

  • Park, Sin-Young;Kim, Cheol-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.38-55
    • /
    • 2013
  • This study has been performed to select several indicators of long-range transport process that can be applied to the Northeast Asia. We first classified high air pollution days into long-range transport (LRT) dominant cases and the local emission dominant (LED) cases based on the synoptic meteorological variables including vorticity and geostrophic wind speed/direction at a geopotential level of 850 hPa. LRT cases were further categorized into two types: LRT-I type with air mass pathways from northern China and/or Mongolia, and LRT-II type from central and southern China. In each categorized case, we examined the difference of both measured aerosol optical properties of AERONET at two sites in western Korea, and the simulated characteristics of LRT process by MM5-CMAQ model. We contrasted LRT case with LED case, and then generated the LRT indicators applicable to Northeast Asia. The results showed that fine and coarse modes of LRT-II were relatively smaller than LED and LRT-I cases, respectively. Aerosol size distribution showed significantly higher concentration of fine-mode particle (mainly smoke or urban aerosols) in LED case in comparison with that of LRT groups (LRT-I, II), suggesting the amplitudes fine modes of LRT relative to LED as a possible LRT indicator. From the results of MM5-CMAQ modeling, we concluded that the conversion ratios for sulfur ($F_s$) were the most effective indicators of LRT cases, and the ratio of VOC to NOx and NOx to CO were found to be the second most effective indicators of LED case.

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

Study on the Free CaO Analysis of Coal Ash in the Domestic Circulating Fluidized Bed Combustion using ethylene glycol method (에틸렌글리콜법을 활용한 국내 순환유동층보일러 석탄회의 Free CaO 평가 연구)

  • Seo, Jun-Hyung;Baek, Chul-Seoung;Kim, Young-Jin;Choi, Moon-Kwan;Cho, Kye-Hong;Ahn, Ji-Whan
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • This study was carried out to physicochemical properties and free CaO contents of coal ash in domestic circulating fludized bed combustion power plant using ethylene glycol method. Results of physicochemical properties, there are many differences in CaO contents for the region position in CFBC plant. The reason, It is considered to be reflected that regulation of exhaust concentration for oxides of sulfur and other operation characteristics of region position in CFBC plant. Free CaO contents are 1.96 ~ 10.78% of fly ash and 0.07~4.24 % of bottom ash, fly ash is higher than in the bottom ash. besides CaO contents of raw materials, particle distribution have a lot of influence Free CaO contents.

Synthesis, characterization and potential applications of Ag@ZnO nanocomposites with S@g-C3N4

  • Ahmad, Naveed;Javed, Mohsin;Qamar, Muhammad A.;Kiran, Umbreen;Shahid, Sammia;Akbar, Muhammad B.;Sher, Mudassar;Amjad, Adnan
    • Advances in materials Research
    • /
    • v.11 no.3
    • /
    • pp.225-235
    • /
    • 2022
  • It includes the synthesis of pristine ZnO nanoparticles and a series of Ag-doped zinc oxide nanoparticles was carried out by reflux method by varying the amount of silver (1, 3, 5, 7 and 9% by mol.). The morphology of these nanoparticles was investigated by SEM, XRD and FT-IR techniques. These techniques show that synthesized particles are homogenous spherical nanoparticles having an average particle size of about 50-100 nm along with some agglomeration. The photocatalytic activity of the ZnO nanoparticles and Ag doped ZnO nanoparticles were investigated via photodegradation of methylene blue (MB) as a standard dye. The data from the photocatalytic activity of these nanoparticles show that 7% Ag-doped ZnO nanoparticles exhibit much enhanced photocatalytic activity as compared to pristine ZnO nanoparticles and other percentages of Ag-doped ZnO nanoparticles. Furthermore, 7% Ag-doped ZnO was made composites with sulfur-doped graphitic carbon nitride by physical mixing method and a series of nanocomposites were made (3.5, 7.5, 25, 50, 75% by weight). It was observed that the 25% composites exhibited better photocatalytic performance than pristine S-g-C 3 N 4 and pure 7% Ag-doped ZnO. Tauc's plot also supports the photodegradation results.

Investigating the Cause of Ash Deposition and Equipment Failure in Wood Chip-Fueled Cogeneration Plant (우드칩을 연료로 하는 열병합발전소의 회분 퇴적 및 설비 고장 원인 분석)

  • Min Ji Song;Woo Cheol Kim;Heesan Kim;Jung-Gu Kim;Soo Yeol Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.187-192
    • /
    • 2023
  • The use of biomass is increasing as a response to the convention on climate change. In Korea, a method applied to replace fossil fuels is using wood chips in a cogeneration plant. To remove air pollutants generated by burning wood chips, a selective denitrification facility (Selective catalytic reduction, SCR) is installed downstream. However, problems such as ash deposition and descaling of the equipment surface have been reported. The cause is thought to be unreacted ammonia slip caused by ammonia ions injected into the reducing agent and metal corrosion caused by an acidic environment. Element analysis confirmed that ash contained alkali metals and sulfur that could cause catalyst poisoning, leading to an increase in the size of ash particle and deposition. Measurement of the size of ash deposited inside the facility confirmed that the size of ash deposited on the catalyst was approximately three times larger than the size of generally formed ash. Therefore, it was concluded that a reduction in pore area of the catalyst by ash deposition on the surface of the catalyst could lead to a problem of increasing differential pressure in a denitrification facility.