• Title/Summary/Keyword: Sulfur particle

Search Result 95, Processing Time 0.028 seconds

Preparation and Biodistribution of Re-188 Sulfur Colloid (Re-188이 표지된 황 교질(Sulfur Colloid) 제조와 생체내 분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Chang, Young-Soo;Lee, Yong-Sin;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Song, Yeong-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.298-304
    • /
    • 1998
  • Purpose: We evaluated the usefulness of Re-188 sulfur colloid for radiation synovectomy and therapy of intraperitoneal metastasis. Materials and Methods: We investigated the labeling efficiency of Re-188 sulfur colloid on various conditions. The stability of Re-188 sulfur colloid was observed at room temperature for 24 h and in human serum and synovial fluid for 72 h. The particle size distribution of Re-188 sulfur colloid was measured by filtering with various pore size filters. Animal experiment was performed in mice and rabbits. Results: The labeling efficiency of Re-188 sulfur colloid was $64.5{\pm}5.8%$ (n=5) at the conditions of sodium thiosulfate 40 mg, EDTA $Na_2.2H_2O$ 0.8 mg, $KReO_4$ 0.8 mg at pH 1. After purification, the radiochemical purity was higher than 99%. The stability of Re-188 sulfur colloid was high (>99%) at room temperature for 24 h and in human serum and synovial fluid for 72 h. The particle size distribution of Re-188 sulfur colloid was 0.3% ($<1{\mu}m$), 11.2% ($1{\sim}5{\mu}m$), 25.8% ($5{\sim}10{\mu}m$) and 52.8% ($>10{\mu}m$). In mice, 1 h postinjection of Re-188 sulfur colloid into tail vein, uptakes in lung, liver and muscle were $37.30{\pm}5.36$, $32.33{\pm}1.79$, $6.60{\pm}0.02%$ ID/organ respectively. After i.p. injection in mice, the uptakes of extraperitonial organs of Re-188 sulfur colloid at 1 and 24 h were $0.1{\pm}0.1$, $0.4{\pm}0.1%$ ID/organ, and the excretions through urine and feces (${\sim}70 h$) were low ($2.68{\pm}0.80$, $0.95{\pm}0.17%$). When Re-188 sulfur colloid was injected to synovial space of rabbit, the uptake in other organs except knee was very low. Conclusion: Re-188 sulfur colloid showed high labeling efficiency, stability and potency for clinical use.

  • PDF

Theoretical Studies of the Electrical Discharge Characteristics of Sulfur Hexafluoride

  • Radmilovic-Radjenovic, Marija;Radjenovic, Branislav
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.288-294
    • /
    • 2017
  • This paper contains results of the theoretical studies of the electrical breakdown properties in sulfur hexafluoride. Since the strong interaction of high-energy electrons with the polyatomic sulfur hexafluoride molecule causes their rapid deceleration to the lower energy of electron capture and dissociative attachment, the breakdown is only possible at relatively high field strengths. From the breakdown voltage curves, the effective yields that characterize secondary electron productions have been estimated. Values of the effective yields are found to be more consistent if they are derived from the experimentally determined values of the ionization coefficient and the breakdown voltages. In addition, simulations were performed using an one-dimensional Particle-in-cell/Monte Carlo collision code. The obtained simulation results agree well with the available experimental data with an error margin of less than 10% over a wide range of pressures and the gap sizes. The differences between measurements and calculations can be attributed to the differences between simulation and experimental conditions. Simulation results are also compared with the theoretical predictions obtained by using expression that describes linear dependence of the breakdown voltage in sulfur hexafluoride on the pressure and the gap size product.

A Study on the Removal Reaction Characteristics of Sulfur Dioxide (대기오염 물질인 $SO_2$ 제거반응 특성 연구)

  • 강순국;정명규
    • Journal of Environmental Science International
    • /
    • v.4 no.1
    • /
    • pp.41-52
    • /
    • 1995
  • The effects of reaction temperature, SO2 and CO2 concentration in an air gas stream, particle sizes of limestone on the reactivity and capacity of SO2 removal have been determined in a thermogravimetric analyser(TGA). The apparent reaction order of sulfation reaction of pre-calcined lime(CaO) with respect to SO2 is found to be close to unity. The apparent activation energies are found to be 17,000 kcal/kmol for sulfation of pre-calcined lime and 19,500 kcal/kmol for direct sulfation of limestone(CaCO3). The initial sulfation reaction rate of pre-calcined lime increases with increasing temperature, whereas the sulfur capture capacity exhibits a maximum value at 90$0^{\circ}C$. In direct sulfation of limestone, sulfation reactivity and sulfur capature capacity of sorbent increase with increasing temperature and decreasing CO2 concentration in a gas bulk stream. The main pare of pre-calcined lime is shifted to the larger pore sizes and pore volume decreases with increasing sulfation time and temperature. The surface area of lime decreases with increasing calcination temperature under an air atmosphere, whereas is yearly constant under a CO2(5, 10%) atmosphere in a gas stream.

  • PDF

Desulfurization characteristics of low sulfur coal by mild pyrolysis (저온 열분해에 의한 저유황 석탄의 탈황 특성)

  • Park, KyeSung;Yun, ChaeKyung;Nam, YoungWoo
    • Clean Technology
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • Mild pyrolysis of four different coals (two bituminous coals and two Korean antracite) was investigated. Desulfurization characteristics, weight loss and variation of heating values were studied. As operating variables of experiment, pyrolysis temperature($350{\sim}550^{\circ}C$), pyrolysis time(5~20 min.) and particle size(0~3.55mm) were examined. The maximum sulfur removal rate of bituminous coal and anthracite were 38% and 28%, respectively. The optimum mild pyrolysis conditions were 10~15 min for pyrolysis time and $450{\sim}550^{\circ}C$ for pyrolysis temperature. The mild pyrolysis was effective to reduce organic sulfur content. Heating values of char per mass after pyrolysis increased about 5% compared to raw coal. The effect of coal particle size on the desulfurization was not observed.

  • PDF

Particle Scavenging Properties of Rain Clarified by a Complementary Study with Bulk and Semi-bulk Samples

  • Ma, Chang-Jin;Kang, Gong-Unn
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.177-186
    • /
    • 2018
  • It is a well-known fact that precipitation plays an important role in capturing ambient particles, however, the details of particle scavenging properties have not been fully proved. To clarify the particle scavenging properties, a complementary study was carried out with the bulk and semi-bulk rain samples collected in an urban city of Japan. pH showed a continued downturn for a little bit at the beginning rainfall and then a turn-up in the following rainfall. The recorded pH values of rainwater (ranged from 3.5-4.6) demonstrated that the strong acid rain was observed during our field measurements. Compared to the subsequent rainfall, electrical conductivity in the beginning rainfall had about 1.3 times higher level. Sulfur showed an overwhelmingly high concentration compared to other elements in both ambient total suspended particles (TSP) and rain samples. On the contrary to ambient TSP, every element including Ca and Zn in rain showed a continued rise in concentration accompanied by increasing of rainfall amount. During the first period of the rainfall there was no meaningful change in elemental carbon concentration, however, it was largely increased (up to $0.2mg\;L^{-1}$) in the sequential rainfall (4.0-4.5 mm rainfall amount). The theoretically calculated number concentration of particles scavenged by raindrops showed a strong decrease of with the increasing droplet diameter regardless of particle type.

Crystal Sinking Modeling for Designing Iodine Crystallizer in Thermochemical Sulfur-Iodine Hydrogen Production Process (열화학 황-요오드 수소 생산 공정의 요오드 결정화기 설계를 위한 결정 침강 모델링)

  • Park, Byung Heung;Jeong, Seong-Uk;Kang, Jeong Won
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.768-774
    • /
    • 2014
  • SI process is a thermochemical process producing hydrogen by decomposing water while recycling sulfur and iodine. Various technologies have been developed to improve the efficiency on Section III of SI process, where iodine is separated and recycled. EED(electro-electrodialysis) could increase the efficiency of Section III without additional chemical compounds but a substantial amount of $I_2$ from a process stream is loaded on EED. In order to reduce the load, a crystallization technology prior to EED is considered as an $I_2$ removal process. In this work, $I_2$ particle sinking behavior was modeled to secure basic data for designing an $I_2$ crystallizer applied to $I_2$-saturated $HI_x$ solutions. The composition of $HI_x$ solution was determined by thermodynamic UVa model and correlation equations and pure properties were used to evaluate the solution properties. A multiphysics computational tool was utilized to calculate particle sinking velocity changes with respect to $I_2$ particle radius and temperature. The terminal velocity of an $I_2$ particle was estimated around 0.5 m/s under considered radius (1.0 to 2.5 mm) and temperature (10 to $50^{\circ}C$) ranges and it was analyzed that the velocity is more dependent on the solution density than the solution viscosity.

Multivariate Analysis for Classification of Smog Type during the Summer Season in Seoul, Korea (다변량해석을 이용한 서울시 하계 스모그의 형태 분류)

  • 홍낙기;이종범;김용국
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.278-287
    • /
    • 1993
  • In order to calssify smog type durnig the summer season in Seoul, air Quality and meterorological data were analyzed by multivariate analysis. Among 15 variables relating to visibility, 10 variables were selected by multiple regression analysis for clustering of smog types; total suspended particle, sulfur dioxide, ozone, ntrogen dioxide, total hydrocarbon, south-north wind component, ralative humidity, precipitable water, mixing height and air temperature. Somg types were grouped into three clusters using cubic clustering criterion and the mumbers of days in each cluster were contained 74, 28 and 16 days. Each cluster was seperated clearly by sulfur dioxide, precipitable water and air teperature. The first cluster was representative of high ozone concentration and prevailing meterological conditions for ozone formation. Therefore, visibility in the first cluster was considered to be affected by photochemical smog. The third cluster showed characteristics of sulphurous smog type due to the higher concentration of primary pollutant, based on the dry condition than that in another cluster. On the other hand, the characteristic of the second cluster was not relatively clear, but considered to be in an intermediate characteristic between photochemical smog and sulphurous smog type.

  • PDF

Characteristics of Nano-particle Emitted by Auto-ignited Engine with ULSD, Bio-diesel and DME Fuel and Effects of Oxidation Catalyst on Its Reduction (디젤연소가능 청정연료(ULSD, Bio-Diesel, DME)엔진의 극미세입자 정량화 및 촉매 영향)

  • Lee, Jin-Wook;Bae, Choong-Sik;Schonborn, Alessandro;Ladommatos, Nicos
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.3
    • /
    • pp.81-89
    • /
    • 2009
  • In this experimental study, the effects of clean alternative fuels compatible with diesel combustion on nano-sized particle emission characteristics were investigated in a 0.5L auto-ignited single-cylinder engine with a compression ratio of 15. Because the number concentration of nano-sized particles emitted by automotive engine, that are suspected of being hazardous to human health and environment, might increase with engine fuel considerably and recently attracted attention. So a ultra-low sulfur diesel(ULSD), BD100(100% bio-diesel) and Di-Methyl Ether(DME) fuels used for this study. And, as a particle measuring instrument, a fast-response particle spectrometer (DMS 500) with heated sample line was used for continuous measurement of the particle size and number distribution in the size range of 5 to 1000nm (aerodynamic diameter). As this research results, we found that this measurements involving the large proportion of particles under size order of 300nm and number concentration of $4{\times}10^9$ allowed a single or bi-modal distribution to be found at different engine load conditions. Also the influence of oxygen content in fuel and the catalyst could be a dominant factor in controlling the nano-sized particle emissions in auto-ignited engine.

Episodic Particulate Sulfate and Sulfur Dioxide on the Southwestern Japan Coast in March and April 2010

  • Nagatani, Tetsuji;Yamada, Maromu;Kojima, Tomoko;Zhang, Daizhou
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Particulate sulfate in $PM_{2.5}$, sulfur dioxide ($SO_2$) and size-segregated aerosol particle number concentrations were measured at a site ($32^{\circ}19'N$, $129^{\circ}59'E$) on the southwestern Japan coast from 5 March to 10 April, 2010. Results show frequent episodic increases of sulfate and $SO_2$. Compared to the average concentration of sulfate $4.4{\pm}2.7\;{\mu}g\;m^{-3}$ in the whole observation period, episodic sulfate reached $10.5-20.1\;{\mu}g\;m^{-3}$. The variation of sulfate always synchronized with aerosol particles in the size range of $0.1-0.5 {\mu}m$, indicating the episodic sulfate was a consequence of the increase of the sub-micron particles. $SO_2$ did not have remarkable increase in any episodes of sulfate increase. During the passage of low pressure systems which loaded Asian dust in postfrontal air, concentrated sulfate appeared right behind the front but before dust arrival, suggesting the dominance of dust-free particulate sulfate. Weather and backward trajectory analyses revealed that air parcels with high sulfate passed eastern and northeastern China or Korean peninsula before arriving at the site. In contrast, those with high $SO_2$ passed an active volcano, Mt. Sakurajima, about 100 km in the south, suggesting the $SO_2$ was more likely from the volcanic emission. The ratio of sulfate to total sulfur compounds $({SO_4}^{2-})/({SO_4}^{2-}+SO_2)$ was 0.31-0.89 in continentally originated air while was 0.25-0.43 in the air having passed the volcano, showing more efficient conversions of $SO_2$ to sulfate in the air from the continent. The close dependence of the conversion on humidity in the continentally originated air was confirmed.

Effect of Operating Parameters on Microbial Desulfurization of Coal by Acidithiobacillus ferrooxidans. (Acidithiobacillus ferrooxidans에 의한 생물학적 석탄탈황에 미치는 조업인자의 영향)

    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.4
    • /
    • pp.400-407
    • /
    • 2003
  • In microbial coal desulfurization process (MCDP) by using Acidithiobacillus ferrooxidans, the effect of process variables on pyritic sulfur removal efficiency has been investigated. The inhibitory effect of toxic materials contained in coal matrix on the activity of desulfurizing bacteria have been evaluated in coal extracts, and the results showed that the method was useful to evaluate the applicability of a coal which is to be desulfurization to MCDP. The removal efficiency increased with decreasing particle size and decreases with increasing pulp density, but has no significant influence of particle size and pup densities at high pulp densities over 20 wt%. The mass transfers of gaseous nutrients such as oxygen and carbon dioxide into coal slurry with various pulp densities and coal particle size has been studied in an airlift bioreactor. Mass transfer coefficient was independent of pulp density in coal slurry with fine particle below 175 $\mu\textrm{m}$, but significantly decreased with increasing pulp density over 225 $\mu\textrm{m}$. The coal particles over 575 $\mu\textrm{m}$ were significantly settled to the bottom of bioreactor resulting in poor mixing. Considering mass transfer, pulp density and coal mixing, an optimal size of coal particle for the microbial coal desulfurization process seems to be about 500 $\mu\textrm{m}$.