• 제목/요약/키워드: Sulfur oxides

검색결과 124건 처리시간 0.022초

Ca(OH)2촉매를 이용한 플라즈마 반응에 의한 황산화물의 제거에 관한 연구 (A study of decomposition of sulfur oxides using Calcium hydroxide catalyst by plasma reactions)

  • 김다영;우인성;이선희;김도현;김병철
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 추계학술대회
    • /
    • pp.547-560
    • /
    • 2013
  • In this study, the air pollutant removal such as sulfur oxides was studied. A combination of the plasma discharge in the reactor by the reaction surface discharge reactor Calcium hydroxides catalytic reactor and air pollutants, hazardous gas SOx, changes in gas concentration, change in frequency, the thickness of the electrode, kinds of electrodes and the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. The experimental results showed the removal efficiency of 98% in the decomposition of sulfur oxides removal experiment when Calcium hydroxides catalysts and the tungsten(W) electrodes were used. It was increased 3% more than if you do not have the catalytic. If added to methane gas was added the removal efficiency increased decomposition.

  • PDF

스크러버 연계 배기가스 배출제어용 3방향 댐퍼밸브의 구조 안전성 평가 (Structural Safety Evaluation of a 3-way Damper Valve for Scrubber-linked Exhaust Gas Control)

  • 김영훈
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.1007-1014
    • /
    • 2020
  • IMO(International Maritime Organization) continues to strengthen environmental regulations on exhaust gases such as CO2, NOx, SOx. As for sulfur oxides, from 1 January 2020, all ships on international voyages must use fuel with a sulfur content of 0.5% or less. Or, it is obligatory to use an exhaust gas treatment device that has the same effect. Shipping companies are using low-sulfur oil, replacing them with LNG fuel, or installing scrubbers that suppress sulfur oxide emissions. In the case of ships using bunker C oil, the load on the engine is lower when entering and departing, so the exhaust gas pressure is lowered and the scrubber cannot be properly utilized. Therefore, diesel oil with low sulfur content is used when entering and leaving the coast. When diesel oil is used, exhaust gas is directly discharged through the control system and piping system, and when bunker C oil is used, sulfur oxides are reduced by scrubbers through other control systems and piping systems to discharge exhaust gas. Accordingly, a company has developed a system called a three-way damper valve that can control exhaust gas emissions while integrating these two control systems and piping systems into one. In this study, the control characteristics of the integrated exhaust gas control system and structural safety against external loads in a high-temperature exhaust gas environment were reviewed.

사용시약별로 본 이산화연법에 의한 대기중 황산화물의 비교측정및 자동측정 성적과의 비교 (Comparative Experiment to Determine the Activation Factor of Lead dioxide by Kinds in Measuring the Concentration of Sulfur oxides in the Atmosphere by $PbO_2$ Cylinder Method)

  • 최덕일
    • 한국환경보건학회지
    • /
    • 제2권1호
    • /
    • pp.29-31
    • /
    • 1975
  • This experiment Was carried out under two points of view, from May 1st to the end of 1973. One was the comparative determination of the activation factor of Lead dioxide by kinds in measuring of Sulfur oxides concentration by $PbO_2$ cylinder method, and the other was the comparison that result with the record of auto analyzer. Five measuring sites were selected out of Seoul City. Three kinds of Lead dioxide made in Japan (B,C and D) were compared with Standard $PbO_2$ (A for use in Determination of Sulphur in the atmosphere, purity 99% up) made in British Institution, and monthly measuring was conducted at every sampling site. The recording by auto analyzer (Beckman Model 906-A $SO_2$ Analyzer) was conducted once or twice a month for 24 hours at each sampling site during the same period. And some significant results were obtained. 1. In comparative experiments to determine the activation degree of three kinds of Lead dioxide (B,C and D), the obtained correction factor of B reagent was 1.09, 1.16 in C and 1.30 in D against Standard $PbO_2$ (A). Therefore, it should be in need of standardization or clear statement about the reagents for use, in determination sulfur oxides by $PbO_2$ cylinder method. 2. Generally, the concentration of Sulfur dioxide by wilkins' convertion method from $SO_3$ showed about 20-30% higher than those by Auto analyzer.

  • PDF

복합촉매를 이용한 플라즈마 반응에 의한 황산화물의 제거에 관한 연구 (A study of decomposition of sulfur oxides using Composite catalyst by plasma reactions)

  • 우인성;황명환;김다영;김관중;김성태;박화용
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 춘계학술대회
    • /
    • pp.655-668
    • /
    • 2013
  • In this study, a combination of the plasma discharge in the reactor by the reaction surface discharge reactor complex catalytic reactor and air pollutants, hazardous gas SOx, change in frequency, residence time, and the thickness of the electrode, the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. 20W power consumption 10kHz frequency decomposition removal rate of 99% in the decomposition of sulfur oxides removal experiment that is attached to the titanium dioxide catalyst reactor experimental results than if you had more than 5% increase. If added to methane gas was added, the removal efficiency increased decomposition, the oxygen concentration increased with increasing degradation rate in the case of adding carbon dioxide decreased.

  • PDF

전국(全國) 산업장(産業場)에서 배출(排出)되는 오염물질량(汚染物質量)에 관(關)한 연구(硏究) (A Study on the Status of Air and Water Pollutants Emission from Industries in Korea)

  • 차철환;장창섭;김형원;성영자
    • Journal of Preventive Medicine and Public Health
    • /
    • 제6권1호
    • /
    • pp.27-41
    • /
    • 1973
  • In order to provide some basic data for the control of air and water pollution in Korea, the authors have estimated the amount of air and water pollutants emitted from industries which are employed over 20 employees. This study have done from July 1, 1972 to the end of March 1973. The results are as followings; 1. Total number of establishments with over 20 employees is 5,197 in Korea and the largest group establishments was the manufacturing of textiles with 1,363 establishments (26.2%). 2. By order of number of employees it was observed that there 2,800 industries with 20-59(53.9%) employees, 1,101 with 50-99 (21.2%), 571 with 100-199 (11.0%), 501 with 200-499 (9.6%) and 225 with over 500 (4.3%) respectively. 3. By order of regional distribution, it was observed that there were 2,257 industries in Seoul (43.2%) and 736 industries in Pusan(14.2%). 4. Industrial coal consumption was 596,154 M/T in 1972, but it' 11 be 315,000 M/T in 1980. Fuel consumption was 4,972,000 K1 in 1972, and estimated volume will be 19,370,000 K1 in 1980. 5. Total amounts of air polutants entitled from industries by fuel combustion were sulfur oxides 79,459 tons, carbon monoxide 33,908 tons, particulate 31,304 tons and hydrocarbon 30,280 tons in 1972 but in 1990 there will be sulfur oxides 1,010,474 tons, nitrogen oxides 204,575 tons, carbon monoxide 68,014 tons, particulate 64,820 tons and hydrocarbon 67,622 tons, respectively. 6. Annual emitted air pollutants through the working processes were sulfur oxides 91,250 tons and nitrogen oxides 32,485 tons in 1972, but sulfur oxides 118,625 tons and nitrogen oxides 42,555 tons will be present in 1980, respectively. 7. Annual emitted air pollutants by national unit area amounted to $0.77ton/km^2/year$ in 1965 and $14.7ton/km^2/year$ in 1980. 8. Total industrial wastes from all industries in Korea were estimated at 810,360 tons/day in 1972; manufacturing of chemicals and plastic products showed the highest amount of wastes at 470,000 tons/day. 9. The amounts of water pollutants due to industrial wastes were the B.O.D., 471.5 tons/day, suspended solid 331.5 tons/day, CN, 2.3 tons/day, and Cr. 3.4 tons/day in 1972, but it might be evident of a B.O.D. of 3,388 tons/day, suspended solid 2,544 tons/day, CN 20.1 tons/day, and 26.5 tone/day in 1990. 10. Total population equivalent of B.O.D. was 943,000 in 1972, and the estimated value in 1950 will be 6,780,000.

  • PDF

석탄화력 발전설비의 출력에 따른 탈황 흡수탑 액기비와 황산화물 배출농도 변화에 대한 연구 (Variation of Liquid to Gas Ratio and Sulfur Oxide Emission Concentrations in Desulfurization Absorber with Coal-fired Thermal Power Plant Outputs)

  • 김기영;문승재
    • 플랜트 저널
    • /
    • 제14권4호
    • /
    • pp.39-47
    • /
    • 2018
  • 본 연구에서는 정격출력 500 MW로 연속운전 하는 표준석탄화력 발전설비의 출력을 300 ~ 500 MW로 변동운전하게 될 때 황산화물의 생성량과 탈황설비 흡수탑에서의 황산화물 배출농도 변화를 비교하고, 출력에 반비례하는 과다한 액기비 개선을 제안하였다. 저출력에서 연소효율 보정을 위해 과잉공기비를 높임에 따라 발생하는 연소가스량에 비해 상대적으로 황산화물의 비율이 낮아지기 때문에 고유황 연료일수록 고출력에서 유황성분의 생성농도가 상승하였다. 출력변동과 함께 탈황흡수탑 입구 황산화물 생성농도를 300 ~ 500 ppm으로 변화시켰을 때, 석회석 슬러리와 연소가스의 액기비는 10.99 ~ 16.27로 변화되었다. 따라서 저부하시 액기비 상승에 따른 잉여에너지저감을 위한 슬러리의 필요최소 유량은 300 MW 출력에서 황산화물 배출농도를 x라고 했을 때 다음 상관관계식을 추천한다. $y1[m^3/sec]=0.11x+3.74$

  • PDF

고성능 리튬-황 전지를 위한 금속산화물을 첨가한 탄소나노튜브 프리스탠딩 전극 (Metal Oxides Decorated Carbon Nanotube Freestanding Electrodes for High Performance of Lithium-sulfur Batteries)

  • 신윤정;정현서;김은미;김태윤;정상문
    • Korean Chemical Engineering Research
    • /
    • 제61권3호
    • /
    • pp.426-438
    • /
    • 2023
  • 차세대 전지로 주목받는 리튬-황 전지는 높은 에너지 밀도를 갖는 반면, 황의 절연 특성, 셔틀 현상 그리고 부피팽창으로 인하여 상용화에 어려움이 있다. 본 연구에서는 경제적이고 간단한 진공여과 방법으로 바인더와 집전체가 없는 프리스탠딩 전극을 제조하였고 탄소나노튜브(CNT)를 황의 전기전도도 향상을 위하여 사용하였다. 여기서 CNT는 집전체와 도전재 역할을 동시에 수행하였다. 추가로 리튬폴리설파이드의 흡착에 용이한 금속산화물(MOx, M=Ni, Mg)을 CNT/S 전극에 첨가함으로써 리튬-황 전지의 셔틀반응을 억제하였다. MOx@CNT/S 전극은 금속산화물을 도입하지 않은 CNT/S 전극에 비해 높은 용량 특성과 사이클 안정성을 나타내었으며, 이는 금속산화물의 우수한 리튬폴리설파이드 흡착 특성으로 인하여 황 활물질의 손실을 억제한 결과이다. MOx@CNT/S 전극 중에서 NiO를 도입한 NiO@CNT/S 전극은 1 C에서 780 mAh g-1의 높은 방전용량을 나타내었고 200 사이클 후 134 mAh g-1으로 극심한 용량 감소가 나타났다. MgO@CNT/S 전극은 비록 초기 사이클에 544 mAh g-1의 낮은 방전용량을 나타냈지만, 200 사이클까지 용량을 90% 유지하는 우수한 사이클 안정성을 나타내었다. 고용량과 사이클 안정성 확보를 위하여 Ni:Mg를 0.7:0.3의 비율로 혼합한 Ni0.7Mg0.3O@CNT/S 전극은 755 mAh g-1 (1 C)의 초기 방전용량과 200 사이클 후에도 90% 이상의 용량 유지율을 나타내었다. 따라서 이원 금속산화물의 CNT/S 프리스탠딩으로의 적용은 고용량 특성뿐만 아니라 가장 큰 문제인 리튬폴리설파이드의 용출을 효과적으로 개선하여 경제적이고 고성능 리튬-황 전지의 개발이 가능함을 시사한다.

경유의 Model solution에서 고정화효소를 이용한 Dibezothiophene의 산화

  • 허정찬;성현태;류근갑
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.517-520
    • /
    • 2001
  • Fossil fuels such as coal and crude oil contain various organic sulfur compounds. Combustion of these fuels emit sulfur oxides which are considered as msjor air pollutants causing acid rain problem. Among various organic sulfur compounds, aromatic sulfur compounds of thiophenes which constitute major sulfur fractions of heavy oils are not easily removed by hydrodesulfurization. Many peroxidase and hemoproteins are known to oxidize dibenzothiophene (DBT) to dibenzothiophene-sulfoxide(DBT - sulfoxide) then dibenzothiophene- sulfone (DBT-sulfone). The oxidation of DBT by the immobilized hemoproteins in n-octane was increased significantly when the hemoproteins were deposited on celites of the particle size between 0.75 - 1.0 mm and a conventional substrates. such as t-butyl hydroperoxide and cumene hydroperoxide. In anhydrous organic solvents with log P values larger than 4.0 DBT was completely oxidized by cumene hydroperoxide catalyzed by cytochrome c deposited on celites.

  • PDF

염소와 황을 함유한 폐기물의 소각시 생성되는 유해 중금속류 결정에 대한 화학평형 계산 (An Equilibrium Analysis to Determine the Speciation of Metals in the Incineration of Waste Containing Chlorine and Sulfur)

  • 이정진;황정호
    • 한국연소학회지
    • /
    • 제1권1호
    • /
    • pp.31-39
    • /
    • 1996
  • An equilibrium analysis was carried out to determine principal species in the incineration of hazardous waste, which was assumed as a compound of hydrocarbon fuel, chlorine, sulfur, and heavy metals, and their behaviors with variation of temperature, chlorine and sulfur concentrations. Calculated results showed that the most important parameter influencing the principal species was temperature. Chlorine concentration affected on mole fractions of the species, especially at high temperature. Existence of sulfur had a significant effect on the species at low temperature, regardless of surfur concentration. Generally, principal species at high temperature were chlorides and oxides, while the principal species at low temperature were sulfides. As temperature increased, mole fractions of the principal species increased at low temperature, however, mole fractions of some metal species decreased at high temperature.

  • PDF

상온용 나트륨/유황전지의 방전 특성 (Discharge Properties of Sodium-sulfur Batteries at Room Temperature)

  • 김태범;안효준;허보영
    • 한국재료학회지
    • /
    • 제16권3호
    • /
    • pp.193-197
    • /
    • 2006
  • The sodium/sulfur(Na/S) battery has many advantages such as high theoretical specific energy(760Wh/kg), and low material cost based on the abundance of electrode material in the earth. It has been reported that the electrochemical properties of sodium/sulfur cell above $300^{\circ}C$, utilized a solid ceramic electrolyte and liquid sodium and sulfur electrodes. A lot of researches have been performed in this field. Recently, Na/S battery system was applied for electricity storage system for load-leveling. One of severe problems of sodium/sulfur battery was high operating temperature above $300^{\circ}C$, which could induce the explosion and corrosion by molten sodium, sulfur and polysulfides. In order to develop sodium battery operated at low temperature, sodium ion battery has been studied using carbon anode, and sodium oxides cathodes. However, the energy densities of the sodium ion batteries were much lower than high temperature sodium/sulfur cell. In this study, the sodium/sulfur battery with 1M $NaCF_3SO_3$ is tested at room temperature. The charge-discharge mechanism was discussed based on XRD, DSC, SEM and EDS results.