• Title/Summary/Keyword: Sulfur oxides

Search Result 121, Processing Time 0.032 seconds

A study of decomposition of sulfur oxides using Calcium hydroxide catalyst by plasma reactions (Ca(OH)2촉매를 이용한 플라즈마 반응에 의한 황산화물의 제거에 관한 연구)

  • Kim, Da Young;Woo, In Sung;Lee, Sun Hee;Kim, Do Hyeon;Kim, Byeong Cheol
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.547-560
    • /
    • 2013
  • In this study, the air pollutant removal such as sulfur oxides was studied. A combination of the plasma discharge in the reactor by the reaction surface discharge reactor Calcium hydroxides catalytic reactor and air pollutants, hazardous gas SOx, changes in gas concentration, change in frequency, the thickness of the electrode, kinds of electrodes and the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. The experimental results showed the removal efficiency of 98% in the decomposition of sulfur oxides removal experiment when Calcium hydroxides catalysts and the tungsten(W) electrodes were used. It was increased 3% more than if you do not have the catalytic. If added to methane gas was added the removal efficiency increased decomposition.

  • PDF

Structural Safety Evaluation of a 3-way Damper Valve for Scrubber-linked Exhaust Gas Control (스크러버 연계 배기가스 배출제어용 3방향 댐퍼밸브의 구조 안전성 평가)

  • Kim, Young-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.1007-1014
    • /
    • 2020
  • IMO(International Maritime Organization) continues to strengthen environmental regulations on exhaust gases such as CO2, NOx, SOx. As for sulfur oxides, from 1 January 2020, all ships on international voyages must use fuel with a sulfur content of 0.5% or less. Or, it is obligatory to use an exhaust gas treatment device that has the same effect. Shipping companies are using low-sulfur oil, replacing them with LNG fuel, or installing scrubbers that suppress sulfur oxide emissions. In the case of ships using bunker C oil, the load on the engine is lower when entering and departing, so the exhaust gas pressure is lowered and the scrubber cannot be properly utilized. Therefore, diesel oil with low sulfur content is used when entering and leaving the coast. When diesel oil is used, exhaust gas is directly discharged through the control system and piping system, and when bunker C oil is used, sulfur oxides are reduced by scrubbers through other control systems and piping systems to discharge exhaust gas. Accordingly, a company has developed a system called a three-way damper valve that can control exhaust gas emissions while integrating these two control systems and piping systems into one. In this study, the control characteristics of the integrated exhaust gas control system and structural safety against external loads in a high-temperature exhaust gas environment were reviewed.

Comparative Experiment to Determine the Activation Factor of Lead dioxide by Kinds in Measuring the Concentration of Sulfur oxides in the Atmosphere by $PbO_2$ Cylinder Method (사용시약별로 본 이산화연법에 의한 대기중 황산화물의 비교측정및 자동측정 성적과의 비교)

  • 최덕일
    • Journal of Environmental Health Sciences
    • /
    • v.2 no.1
    • /
    • pp.29-31
    • /
    • 1975
  • This experiment Was carried out under two points of view, from May 1st to the end of 1973. One was the comparative determination of the activation factor of Lead dioxide by kinds in measuring of Sulfur oxides concentration by $PbO_2$ cylinder method, and the other was the comparison that result with the record of auto analyzer. Five measuring sites were selected out of Seoul City. Three kinds of Lead dioxide made in Japan (B,C and D) were compared with Standard $PbO_2$ (A for use in Determination of Sulphur in the atmosphere, purity 99% up) made in British Institution, and monthly measuring was conducted at every sampling site. The recording by auto analyzer (Beckman Model 906-A $SO_2$ Analyzer) was conducted once or twice a month for 24 hours at each sampling site during the same period. And some significant results were obtained. 1. In comparative experiments to determine the activation degree of three kinds of Lead dioxide (B,C and D), the obtained correction factor of B reagent was 1.09, 1.16 in C and 1.30 in D against Standard $PbO_2$ (A). Therefore, it should be in need of standardization or clear statement about the reagents for use, in determination sulfur oxides by $PbO_2$ cylinder method. 2. Generally, the concentration of Sulfur dioxide by wilkins' convertion method from $SO_3$ showed about 20-30% higher than those by Auto analyzer.

  • PDF

A study of decomposition of sulfur oxides using Composite catalyst by plasma reactions (복합촉매를 이용한 플라즈마 반응에 의한 황산화물의 제거에 관한 연구)

  • Woo, In-Sung;Hwang, Myung-Hwan;Kim, Da-Young;Kim, KwanJoong;Kim, Sung-Tea;Park, Hwa-Young
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.655-668
    • /
    • 2013
  • In this study, a combination of the plasma discharge in the reactor by the reaction surface discharge reactor complex catalytic reactor and air pollutants, hazardous gas SOx, change in frequency, residence time, and the thickness of the electrode, the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. 20W power consumption 10kHz frequency decomposition removal rate of 99% in the decomposition of sulfur oxides removal experiment that is attached to the titanium dioxide catalyst reactor experimental results than if you had more than 5% increase. If added to methane gas was added, the removal efficiency increased decomposition, the oxygen concentration increased with increasing degradation rate in the case of adding carbon dioxide decreased.

  • PDF

A Study on the Status of Air and Water Pollutants Emission from Industries in Korea (전국(全國) 산업장(産業場)에서 배출(排出)되는 오염물질량(汚染物質量)에 관(關)한 연구(硏究))

  • Cha, Chul-Hwan;Jang, Chang-Supp;Kim, Hyung-Won;Sung, Young-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.6 no.1
    • /
    • pp.27-41
    • /
    • 1973
  • In order to provide some basic data for the control of air and water pollution in Korea, the authors have estimated the amount of air and water pollutants emitted from industries which are employed over 20 employees. This study have done from July 1, 1972 to the end of March 1973. The results are as followings; 1. Total number of establishments with over 20 employees is 5,197 in Korea and the largest group establishments was the manufacturing of textiles with 1,363 establishments (26.2%). 2. By order of number of employees it was observed that there 2,800 industries with 20-59(53.9%) employees, 1,101 with 50-99 (21.2%), 571 with 100-199 (11.0%), 501 with 200-499 (9.6%) and 225 with over 500 (4.3%) respectively. 3. By order of regional distribution, it was observed that there were 2,257 industries in Seoul (43.2%) and 736 industries in Pusan(14.2%). 4. Industrial coal consumption was 596,154 M/T in 1972, but it' 11 be 315,000 M/T in 1980. Fuel consumption was 4,972,000 K1 in 1972, and estimated volume will be 19,370,000 K1 in 1980. 5. Total amounts of air polutants entitled from industries by fuel combustion were sulfur oxides 79,459 tons, carbon monoxide 33,908 tons, particulate 31,304 tons and hydrocarbon 30,280 tons in 1972 but in 1990 there will be sulfur oxides 1,010,474 tons, nitrogen oxides 204,575 tons, carbon monoxide 68,014 tons, particulate 64,820 tons and hydrocarbon 67,622 tons, respectively. 6. Annual emitted air pollutants through the working processes were sulfur oxides 91,250 tons and nitrogen oxides 32,485 tons in 1972, but sulfur oxides 118,625 tons and nitrogen oxides 42,555 tons will be present in 1980, respectively. 7. Annual emitted air pollutants by national unit area amounted to $0.77ton/km^2/year$ in 1965 and $14.7ton/km^2/year$ in 1980. 8. Total industrial wastes from all industries in Korea were estimated at 810,360 tons/day in 1972; manufacturing of chemicals and plastic products showed the highest amount of wastes at 470,000 tons/day. 9. The amounts of water pollutants due to industrial wastes were the B.O.D., 471.5 tons/day, suspended solid 331.5 tons/day, CN, 2.3 tons/day, and Cr. 3.4 tons/day in 1972, but it might be evident of a B.O.D. of 3,388 tons/day, suspended solid 2,544 tons/day, CN 20.1 tons/day, and 26.5 tone/day in 1990. 10. Total population equivalent of B.O.D. was 943,000 in 1972, and the estimated value in 1950 will be 6,780,000.

  • PDF

Variation of Liquid to Gas Ratio and Sulfur Oxide Emission Concentrations in Desulfurization Absorber with Coal-fired Thermal Power Plant Outputs (석탄화력 발전설비의 출력에 따른 탈황 흡수탑 액기비와 황산화물 배출농도 변화에 대한 연구)

  • Kim, Kee-Yeong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.39-47
    • /
    • 2018
  • In this research, when the output of the standard coal-fired thermal power plant operating continuously at the rated output of 500 MW is changed to operate at 300 to 500 MW, the amount of sulfur oxide produced and the amount of sulfur oxide in the absorption tower of desulfurization equipment and proposed an extra liquid to gas ratio improvement inversely proportional to the output. In order to calibrate the combustion efficiency at low power, the ratio of sulfur oxides relative to the amount of combustion gas is increased as the excess air ratio is increased. When the concentration of sulfur oxide at the inlet of the desulfurization absorber was changed from 300 to 500 ppm along with the output fluctuation. The liquid to gas ratio of limestone slurry and combustion gas was changed from 10.99 to 16.27. Therefore, if the concentration of sulfur oxides with output of 300 MW is x, The following correlation equation is recommended for the minimum required flow rate of slurry for the reduction of surplus energy due to the increase of the liquid weight at low load. $y1[m^3/sec]=0.11x+3.74$

  • PDF

Metal Oxides Decorated Carbon Nanotube Freestanding Electrodes for High Performance of Lithium-sulfur Batteries (고성능 리튬-황 전지를 위한 금속산화물을 첨가한 탄소나노튜브 프리스탠딩 전극)

  • Yun Jung Shin;Hyeon Seo Jeong;Eun Mi Kim;Tae Yun Kim;Sang Mun Jeong
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.426-438
    • /
    • 2023
  • Lithium-sulfur batteries, recently attracting attention as next-generation batteries, have high energy density but are limited in application due to sulfur's insulating properties, shuttle phenomenon, and volume expansion. This study used an economical and simple vacuum filtration method to prepare a freestanding electrode without a binder and collector. Carbon nanotubes (CNTs) are used to improve the electrical conductivity of sulfur, where CNT also acts as both collector and conductor. In addition, metal oxides (MOx, M=Ni, Mg), which are easy to adsorb lithium polysulfide, are added to the CNT/S electrode to suppress the shuttle reaction in lithium-sulfur batteries, which is a result of suppressing the loss of active sulfur material due to the excellent adsorption of lithium polysulfide by metal oxides. The MOx@CNT/S electrode exhibited higher capacity characteristics and cycle stability than the CNT/S electrode without metal oxides. Among the MOx@CNT/S electrodes, the NiO@CNT/S electrode displayed a high discharge capacity of 780 mAh g-1 at 1 C and an extreme capacity decrease to 134 mAh g-1 after 200 cycles. Although the MgO@CNT/S electrode exhibited a low discharge rate of 544 mAh g-1 in the initial cycle, it showed good cycle stability with 90% of capacity retention up to 200 cycles. Further, to achieve high capacity and cycle stability, the Ni0.7Mg0.3O@CNT/S electrode, mixed with Ni:Mg in the ratio of 0.7:0.3, manifested an initial discharge rate of 755 mAh g-1 (1 C) and a capacity retention rate of more than 90% after 200 cycles. Therefore, applying binary metal oxides to CNT/S provides a freestanding electrode for developing economical and high-performance Li-S batteries, effectively improving lithium polysulfide's high capacity characteristics and dissolution.

경유의 Model solution에서 고정화효소를 이용한 Dibezothiophene의 산화

  • Heo, Jeong-Chan;Seong, Hyeon-Tae;Ryu, Geun-Gap
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.517-520
    • /
    • 2001
  • Fossil fuels such as coal and crude oil contain various organic sulfur compounds. Combustion of these fuels emit sulfur oxides which are considered as msjor air pollutants causing acid rain problem. Among various organic sulfur compounds, aromatic sulfur compounds of thiophenes which constitute major sulfur fractions of heavy oils are not easily removed by hydrodesulfurization. Many peroxidase and hemoproteins are known to oxidize dibenzothiophene (DBT) to dibenzothiophene-sulfoxide(DBT - sulfoxide) then dibenzothiophene- sulfone (DBT-sulfone). The oxidation of DBT by the immobilized hemoproteins in n-octane was increased significantly when the hemoproteins were deposited on celites of the particle size between 0.75 - 1.0 mm and a conventional substrates. such as t-butyl hydroperoxide and cumene hydroperoxide. In anhydrous organic solvents with log P values larger than 4.0 DBT was completely oxidized by cumene hydroperoxide catalyzed by cytochrome c deposited on celites.

  • PDF

An Equilibrium Analysis to Determine the Speciation of Metals in the Incineration of Waste Containing Chlorine and Sulfur (염소와 황을 함유한 폐기물의 소각시 생성되는 유해 중금속류 결정에 대한 화학평형 계산)

  • Lee, Jung-Jin;Hwang, Jung-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.31-39
    • /
    • 1996
  • An equilibrium analysis was carried out to determine principal species in the incineration of hazardous waste, which was assumed as a compound of hydrocarbon fuel, chlorine, sulfur, and heavy metals, and their behaviors with variation of temperature, chlorine and sulfur concentrations. Calculated results showed that the most important parameter influencing the principal species was temperature. Chlorine concentration affected on mole fractions of the species, especially at high temperature. Existence of sulfur had a significant effect on the species at low temperature, regardless of surfur concentration. Generally, principal species at high temperature were chlorides and oxides, while the principal species at low temperature were sulfides. As temperature increased, mole fractions of the principal species increased at low temperature, however, mole fractions of some metal species decreased at high temperature.

  • PDF

Discharge Properties of Sodium-sulfur Batteries at Room Temperature (상온용 나트륨/유황전지의 방전 특성)

  • Kim, T.B.;Ahn, H.Y.;Hur, H.Y.
    • Korean Journal of Materials Research
    • /
    • v.16 no.3
    • /
    • pp.193-197
    • /
    • 2006
  • The sodium/sulfur(Na/S) battery has many advantages such as high theoretical specific energy(760Wh/kg), and low material cost based on the abundance of electrode material in the earth. It has been reported that the electrochemical properties of sodium/sulfur cell above $300^{\circ}C$, utilized a solid ceramic electrolyte and liquid sodium and sulfur electrodes. A lot of researches have been performed in this field. Recently, Na/S battery system was applied for electricity storage system for load-leveling. One of severe problems of sodium/sulfur battery was high operating temperature above $300^{\circ}C$, which could induce the explosion and corrosion by molten sodium, sulfur and polysulfides. In order to develop sodium battery operated at low temperature, sodium ion battery has been studied using carbon anode, and sodium oxides cathodes. However, the energy densities of the sodium ion batteries were much lower than high temperature sodium/sulfur cell. In this study, the sodium/sulfur battery with 1M $NaCF_3SO_3$ is tested at room temperature. The charge-discharge mechanism was discussed based on XRD, DSC, SEM and EDS results.