• 제목/요약/키워드: Sulfide

검색결과 1,552건 처리시간 0.026초

급속한 의식 변화를 초래한 급성 황화수소 중독 1례 (A Case of Acute Hydrogen Sulfide Intoxication Caused Rapid Loss of Consciousness)

  • 안정환;정윤석
    • 대한임상독성학회지
    • /
    • 제2권2호
    • /
    • pp.147-150
    • /
    • 2004
  • Hydrogen sulfide is a colorless, and malodorous 'rotten eggs' gas that results from the decay of organic material. It is a byproduct of industry and agriculture. The mechanism of its toxicity is primarily related to inhibition of oxidative phosphorylation, which causes a decrease in available cellular energy. Because there is no rapid method of detection that is of clinical diagnostic use, management decisions must be made based on history, clinical presentation, and diagnostic tests that imply hydrogen sulfide's presence. Although there is some anecdotal evidence to suggest that the early use of hyperbaric oxygen is beneficial, supportive care remains the mainstay of therapy. We describe an occupational exposure to hydrogen sulfide gas in 51-year-old man. While cleaning the sewage of pigs. he became unconscious. When he arrived in the emergency department, he had irritability and confused mentality. The typical smell of rotten eggs on clothing and exhaled air were enough to be considered to be exposed to hydrogen sulfide. Hyperbaric oxygen therapy was performed. He had a recovery to normal function.

  • PDF

Enhanced Cathode/Sulfide Electrolyte Interface Stability Using an Li2ZrO3 Coating for All-Solid-State Batteries

  • Lee, Jun Won;Park, Yong Joon
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권3호
    • /
    • pp.176-183
    • /
    • 2018
  • In this study, a $Li_2ZrO_3$ coated $Li[Ni_{0.8}Co_{0.15}Al_{0.05}]O_2$ (NCA) cathode was applied to an all-solid-state cell employing a sulfide-based solid electrolyte. Sulfide-based solid electrolytes are preferable for all-solid-state cells because of their high ionic conductivity and good softness and elasticity. However, sulfides are very reactive with oxide cathodes, and this reduces the stability of the cathode/electrolyte interface of all-solid-state cells. $Li_2ZrO_3$ is expected to be a suitable coating material for the cathode because it can suppress the undesirable reactions at the cathode/sulfide electrolyte interface because of its good stability and high ionic conductivity. Cells employing $Li_2ZrO_3$ coated NCA showed superior capacity to those employing pristine NCA. Analysis by X-ray photoelectron spectroscopy and electron energy loss spectroscopy confirmed that the $Li_2ZrO_3$ coating layer suppresses the propagation of S and P into the cathode and the reaction between the cathode and the sulfide solid electrolyte. These results show that $Li_2ZrO_3$ coating is promising for reducing undesirable side reactions at the cathode/electrolyte interface of all-solid-state-cells.

황환원균과 3가철을 이용한 Trichloroethylene의 제거에 관한 연구 (Trichloroethylene Removal Using Sulfate Reducing Bacteria and Ferric Iron)

  • 황기철;민지은;박인선;박재우
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제13권1호
    • /
    • pp.24-31
    • /
    • 2008
  • 혼합균에서 분리 배양한 황환원균에 의해 발생되는 황화수소가 염소계유기오염물질인 트리클로로에틸렌의 환원에 어떠한 영향을 미치는지, 또한 염소계유기오염물질에 대한 환원력이 있다고 알려진 2가철은 황화수소가 존재할 경우 트리클로로에틸렌의 환원과 어떠한 관계에 있는지를 알아보기 위하여 본 실험을 수행하였다. 황환원균에 독성을 나타내지 않는 수준의 트리클로로에틸렌의 농도에서 황화수소 발생 및 트리클로로에틸렌의 분해 실험을 수행한 결과 황산염의 환원으로 발생한 황화수소의 농도는 4.38 mM, 트리클로로에틸렌의 농도는 큰 변화가 없는 것으로 관찰되었으며 이를 통하여 황환원균에 의해 발생되는 황화수소의 농도가 트리클로로에틸렌을 환원시키기에는 부족하다는 것을 알 수 있었다. 그러나 황화수소의 농도가 위 실험에서 발생된 농도보다 100배 정도 높을 경우(438 mM)에는 트리클로로에틸렌에 대한 환원력이 있음을 확인하였다. 대표적인 산화철인 $Fe_2O_3$(3가철)를 첨가하였을 경우, 황환원균의 생장에 따라 황화수소, 2가철 및 트리클로로에틸렌의 농도변화를 관찰하였으며 이를 통하여 황환원균에 의해서 발생된 황화수소가 산화되면서 3가의 산화철을 2가철로 환원시키고 황화수소에 의하여 환원된 2가철이 트리클로로에틸렌을 분해하여 농도를 감소시키는 것을 확인하였다. 위의 실험결과를 바탕으로 낮은 농도의 황화수소는 트리클로로에틸렌의 환원에 영향을 미치지 못하며 다만, 황화수소에 의해 환원된 2가철이 트리클로로에틸렌을 분해시키는 주요한 요인임을 알 수 있었다. 또한 실제 해수중에서 황환원균과 $Fe_2O_3$가 공존할 경우의 트리클로로에틸렌의 제거 효과를 살펴보기 위한 실험을 한 결과 황환원균이 황화수소를 생성하여 트리클로로에틸렌의 제거에 영향을 줄 수 있는 반응들은 황환원균 생장에 필수적인 탄소원의 농도가 확보될 때 가능하다는 결론을 얻을 수 있었다.

황화철에 의한 6가 크롬의 환원에 관한 연구 (A Study of Hexavalent Chromium Reduction by Iron Sulfide)

  • 조세이;박재우
    • 대한환경공학회지
    • /
    • 제27권6호
    • /
    • pp.657-662
    • /
    • 2005
  • 황화철은 자연 퇴적토와 공극수에서 생물학적 과정이나 무생물학적 과정에 의해서 상당량 생성된다. 본 연구에서는 6가 크롬과 황화철로부터 용해되어 나온 이가 철과 6가 크롬의 반응에 관하여 알아보기 위해 6가 크롬의 초기농도를 다르게 하여 pH 4와 8에서 수용액상과 고체상으로 나누어 실험을 수행하였다. 또한 철산화물인 ${\alpha}-Fe_2O_3$, ${\alpha}-FeOOH$, $Fe_3O_4$와 0가 철을 이용하여 황화철에 의한 6가 크롬의 제거효율을 비교하였다. 6가 크롬의 제거율은 pH 4일 때가 pH 8일 때 높았으며 이는 낮은 pH에서 황화철로부터 용해되어 나온 이가 철의 양의 pH 4에서 더 많기 때문인 것으로 판단된다. 투과전자 현미경(Transmission Electric Microscopy)을 이용한 황화철의 표면 분석을 통하여 고체 표면에 형성된 침전물을 확인하였다. 이는 황화철에 의한 6가 크롬의 환원 작용에 의하여 iron(oxyhyoxide) 침전이 형성된 것으로 판단된다. 황화철은 철 산화물 및 영가 철에 비하여 그 제거능이 월등하며 이는 이가 철과 함께 황화물의 상호작용인 것으로 사료된다.

Fe-EDTA 착물을 이용한 황화수소 제거의 최적 반응 조건 (Optimum Conditions for Removal of Hydrogen Sulfide Using Fe-EDTA Complex)

  • 진상기;차진명;이인화;윤석진;김시욱
    • 공업화학
    • /
    • 제7권1호
    • /
    • pp.177-185
    • /
    • 1996
  • Fe-EDTA 착물을 이용한 황화수소 제거의 최적 반응 조건을 기포탑 반응기에서 조사하였다. 착물의 농도가 증가할수록 황화수소 산화 반응에서 전환량은 증가하였고 pH 변화와 Fe 농도는 완만하게 감소하였으며, elemental sulfur의 생성량은 증가하였다. 또한 황화수소는 0.05M 이상의 착물 농도에서 효율적으로 제거되었다. pH에 따른 황화수소 산화반응에서 pH는 착물의 안정도에 중요한 인자이고 반응 중 최적 pH 범위는 8.5~9.5 이었다. [EDTA]/[Fe] 비가 증가할수록 황화수소 산화 반응의 전환량은 증가하였고 반응 중 EDTA 농도가 감소하면 FeS로 침전이 촉진되어 전환량은 감소하였다. 즉 EDTA 농도가 증가될수록 Fe-EDTA 착물이 안정되어 전환량이 증가하였다.

  • PDF

미세버블을 이용한 바이오가스 탈황정제 연구 (Desulfurization of Biogas Using Micro Bubble in a Biogas Plant)

  • 탁봉열;탁봉식;김찬규;민길호;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.518-523
    • /
    • 2013
  • This paper describes the reduction of a hydrogen sulfide ($H_2S$) generated from a biogas plant. Micro bubble system is adopted to supply air into the water in the reaction chamber, which can increase the contact area of the supplied air to the reserving water. Two stage reaction chambers having two reaction rooms are designed and manufactured to enhance the reduction rate of a hydrogen sulfide. Sodium hydroxide (NaOH) is also considered to get rid of a hydrogen sulfide. Air volume rate to the water in a reaction chamber is maintained between 0.5 and $1.0m^3/min$. Throughout experimental measurement of the concentration of a hydrogen sulfide by changing the volume of supplied air into the water, reduction rate of a hydrogen sulfide increases as air volume increases. Adding sodium hydroxide to the water with the air supply can reduce effectively a hydrogen sulfide up to 99.5% from biogas. It is noted that a hydrogen sulfide generated by a biogas plant can reduce by supplying micro bubble air and sodium hydroxide effectively.

Evaluation of Short-Term Exposure Levels on Ammonia and Hydrogen Sulfide During Manure-Handling Processes at Livestock Farms

  • Park, Jihoon;Kang, Taesun;Heo, Yong;Lee, Kiyoung;Kim, Kyungran;Lee, Kyungsuk;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • 제11권1호
    • /
    • pp.109-117
    • /
    • 2020
  • Background: Ammonia and hydrogen sulfide are harmful gases generated during aerobic/anaerobic bacterial decomposition of livestock manure. We evaluated ammonia and hydrogen sulfide concentrations generated from workplaces at livestock farms and determined environmental factors influencing the gas concentrations. Methods: Five commercial swine farms and five poultry farms were selected for monitoring. Real-time monitors were used to measure the ammonia and hydrogen sulfide concentrations and environmental conditions during the manure-handling processes. Monitoring was conducted in the manure storage facility and composting facility. Information on the farm conditions was also collected through interview and walk-through survey. Results: The ammonia concentrations were significantly higher at the swine composting facilities (9.5-43.2 ppm) than at other manure-handling facilities at the swine and poultry farms, and high concentrations of hydrogen sulfide were identified during the manure agitation and mixing process at the swine manure storage facilities (6.9-19.5 ppm). At the poultry manure-handling facilities, the ammonia concentration was higher during the manure-handling processes (2.6-57.9 ppm), and very low hydrogen sulfide concentrations (0-3.4 ppm) were detected. The air temperature and relative humidity, volume of the facility, duration of manure storage, and the number of animals influenced the gas concentrations. Conclusion: A high level of hazardous gases was generated during manure handling, and some levels increased up to risk levels that can threaten workers' health and safety. Some of the farm operational factors were also found to influence the gas levels. By controlling and improving these factors, it would be possible to protect workers' safety and health from occupational risks.

킬레이트 착화학반응에 의한 음식물폐기물 혐기소화가스 중 황화수소의 제거와 황회수 및 경제성평가 (Reuse of Hydrogen Sulfide by Ferric Chelate Reaction of Food Waste Anaerobic Digestion Gas, Sulfur Recovery and its Economic Evaluation)

  • 박영규;양영선
    • 청정기술
    • /
    • 제20권4호
    • /
    • pp.367-374
    • /
    • 2014
  • 0.1~1 M의 철킬레이트 화합물을 이용한 화학흡수반응에 의한 바이오가스내 황화수소제거를 위한 실험이 수행되었다. 철킬레이트 화합물을 이용한 황화수소제거는 철킬레이트의 최적산화반응을 통해 이루어진다. 바이오가스에 존재하는 황화수소는 킬레이트농도 및 pH 등의 공정조건에 따라 효과적으로 제거될 뿐만 아니라 철킬레이트 산화반응에 의해 황화수소내 존재하는 황성분을 생성시킨다. Fe-EDTA의 농도가 증가하면 철킬레이트 화합물의 착물이 안정되어 황생성의 전환이 증가하였다. 또한 철킬레이트화합물의 안정도는 pH에 따라 변하는 중요한 인자이고 pH 9에서 최적반응을 나타냈다.

가열에 의한 김치의 pH, 관능성 및 휘발성냄새성분의 변화 (Changes in pH, Sensory Properties and Volatile Odor Components of Kimchi by Heating)

  • 고영태;백인희
    • 한국식품과학회지
    • /
    • 제34권6호
    • /
    • pp.1123-1126
    • /
    • 2002
  • 김치를 $25^{\circ}C$에서 4일간 숙성시킨 후, pH와 관능성을 관찰하고 몇가지 주요한 휘발성냄새성분의 변화를 관찰하였다. pH는 가열에 의하여 거의 변화가 없었다. 전반적인 기호도는 가열된 시료, 특히 40분 가열시료의 기호도수치가 높았으며 3시료 사이에 유의적인 차이를 보였다(p<0.05). 산미, 맛, 냄새, 조직감의 경우도 전반적인 기호도와 유사한 경향을 보였으나, 형태의 경우는 3시료 사이에 차이가 없었다. 휘발성 냄새성분의 결과를 보면 reference(비가열시료)는 allyl mercaptan, methyl allyl sulfide, dimethyl disulfide, diallyl sulfide, diallyl disulfide와 같은 5종의 황함유성분과 ethanol이 검출되었는데, $100^{\circ}C/10$분시료는 ethanol과 methyl allyl sulfide만 검출되고 그 함량도 reference에 비하여 현저하게 감소하였으며, $100^{\circ}C/40$분 시료는 $100^{\circ}C/10$분 시료와 비교하여 ethanol의 함량은 현저히 감소하고 methyl allyl sulfide의 함량은 거의 변화가 없었다.

Semiempirical MO Study on Malonyl-CoA. 1. Malonic Acid and Malonyl Methyl Sulfide

  • 유인기;김영주;김시춘;김유삼;강영기
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권2호
    • /
    • pp.112-120
    • /
    • 1995
  • The conformational study on malonic acid, hydrogen malonate, malonate, malonyl methyl sulfide, and malonyl methyl sulfide anion, as the model compounds of malonyl-CoA, was carried out using the semiempirical MO methods (MNDO, AM1, and PM3) and hydration shell model. On the whole, the feasible conformations of malonic acid, hydrogen malonate, and malonate seem to be similar to each other. In malonic acid and malonate, two carboxyl groups are nearly perpendicular to the plane of the carbon skeleton, despite of different orientation of two carboxyl groups themselves. In particular, two carboxyl groups of hydrogen malonate are on the plane formed by carbon atoms with an intramolecular hydrogen bond. The calculated results on the geometry and conformation of three compounds are reasonably consistent with those of X-ray and spectroscopic experiments as well as the previous calculations. The orientation of two carbonyl groups of malonyl methyl sulfide is quite similar to that of malonic acid, but different from that of its anion. Especially, the computed probable conformations of the sulfide anion by the three methods are different from each other. The role of hydration seems not to be crucial in stabilizing the overall conformations of malonic acid, hydrogen malonate, malonate, and malonyl methyl sulfide. However, the probable conformations of the unhydrated sulfide anion obtained by the MNDO and AM1 methods become less stabilized by including hydration. The AM1 method seems to be appropriate for conformational study of malonyl-CoA and its model compounds because it does not result in the formation of too strong hydrogen bonds and significant change in conformational energy from one compound to another.