• 제목/요약/키워드: Suction system

검색결과 426건 처리시간 0.029초

ECO Vacuum Filter System 용 흡입 챔버의 구조해석 및 형상 최적화에 관한 연구 (A Study on the Shape Optimization and Structural Analysis of the Suction Chamber for an ECO Vacuum Filter System)

  • 이춘만;하재현;우완식;김은중
    • 한국정밀공학회지
    • /
    • 제33권12호
    • /
    • pp.971-977
    • /
    • 2016
  • Recently, the problem of the accumulation of fine sludge from the cutting oil generated during machining processes has become a major threat to the environment. The fine sludge has adverse affects on the human body and the environment, and significantly contributes to marine pollution. However, a microfiltration technique that can process the sludge still needs to be studied and developed on a global scale. Therefore, it is necessary to develop eco-friendly equipment such as an ECO vacuum filter system and eco-friendly technologies for processing cutting oil. In this study, a structural analysis was carried out using a finite element method (FEM). Improved models of the suction chamber for the ECO vacuum filter system were proposed based on the analysis of the displacement and stress of the system. The model with the best result was then optimized using the commercial software, ANSYS. It was confirmed that, in the optimized model, displacement and stress were reduced in comparison with the initial model. Finally, the structural stability of the optimized model was verified through analysis.

부분흡입노즐방식의 터빈시스템에 대한 성능 평가 (Performance Evaluations for the Partial-Admission Type Turbine System)

  • 홍창욱;박승경;남궁혁준;김경호;김영수;우유철
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2001년도 제17회 학술발표회 논문초록집
    • /
    • pp.11-14
    • /
    • 2001
  • 3-D compressible flow analysis was conducted by using mixing plane method for turbine system which is consisted of partial admission nozzle and rotor. Computational results are shown oblique shock wave in blade leading and trailing edge and also shown flow separation along suction surface of blade due to abrupt blade curvature. But computational results are well agree with 1-D calculation results and experimental data.

  • PDF

R-600a 및 R-134a를 공용으로 사용한 소형 냉동사이클의 성능 특성 최적화에 대한 실험적 연구 (An Experimental Study on the Optimization of the Performance Characteristics of a Refrigeration System Using R-600a and R-134a)

  • 장의성;윤원재;정현준;정해원;김용찬
    • 설비공학논문집
    • /
    • 제22권5호
    • /
    • pp.268-274
    • /
    • 2010
  • Because both R-134a and R-600a are used as a refrigerant of a household refrigerator in the global market, the home-appliance industry needs an optimized cycle for both refrigerants. The objective of this study is to provide the design guideline on the optimization of a refrigeration system using both refrigerants. For both refrigerants, the performance characteristics of the refrigeration system were tested by varying refrigerant charge amount, capillary tube length, suction diameter and SLHX length. The tested refrigeration system was optimized at the refrigerant charge of 60 g and the capillary tube length of 3600 mm with R-134a, and the refrigerant charge of 34 g and the capillary tube length of 3900 mm with R-600a. The COP increased from 1.63 to 1.68 for R-134a and increased from 1.37 to 1.48 for R-600a, respectively, by applying the suction diameter expansion. In addition, the COP of the R-134a and R-600a system decreased by 2.3~2.4% as the SLHX length decreased by 300 mm.

해상풍력 석션버켓 기초 구조-지반 상호작용 비선형 구조해석 및 실험결과 비교 (Nonlinear Structure-Soil Interaction Analysis for the Suction Bucket Foundation of Offshore Wind-Turbine)

  • 진정인;김동현;정민욱
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.469-475
    • /
    • 2016
  • 최근 석유 에너지 고갈의 문제에 봉착함에 따라 신재생 에너지, 즉 풍력 에너지 분야에 대한 연구가 자연스럽게 부각되고 있다. 그 중 해상풍력은 육상풍력에 비교해 바람 자원이 풍부하기 때문에 효율성 측면에서 주목 받고 있지만 전체 시스템의 설치비용에 따른 경제성이 중요한 문제가 되고 있다. 일반적으로 해상 풍력 사업의 구성비에서 지지구조물 설치비용의 비율이 통상 25% 이상을 차지하는 경향이 있으며, 설계된 지지구조에 대해 정확한 해석과 분석이 가능 하다면 설치 및 시공분야의 경제성을 확보하는데 중요한 역할을 할 수 있다. 본 연구에서는 해상 부유식 풍력발전시스템의 경제성 확보에 중요한 역할을 할 수 있는 석션버켓 기초의 지반연성 비선형 구조해석 기법을 구축하고 이에 대한 검증을 위해 실험결과와 비교검증을 수행하였다.

고공 환경 모사를 위한 병렬형 이젝터 구성에 따른 특성 연구 (A Numerical Analysis on Performance of Parallel Type Ejector for High Altitude Simulation)

  • 신동해;유이상;신민규;오정화;고영성;김선진
    • 한국추진공학회지
    • /
    • 제23권1호
    • /
    • pp.52-60
    • /
    • 2019
  • 본 연구에서는 수치해석을 활용하여 여러 개의 이젝터로 구성된 병렬형 이젝터의 성능과 구조에 대한 특성을 확인하였다. 병렬 이젝터의 설계는 단일 이젝터와 동일한 설계 변수(질량 흡입비, 압축비, 팽창비)를 사용하였다. 해석 결과에 의하면, 병렬형과 단일 이젝터의 작동 질량 흡입비의 비가 같을 경우에는 성능에 있어 큰 차이를 보이지 않았으나, 시스템의 크기가 작아지는 이점이 있음을 확인하였다. 또한, 동일 성능의 이젝터를 병렬로 배치하였을 때는 질량 흡입비가 단일 보다 감소하여 더 낮은 압력을 구현하는 것을 확인하였다. 해석 결과를 종합하면 병렬형 이젝터 성능은 단일 이젝터와 크게 다르지 않으나, 병렬형 이젝터 구성에 따라서는 크기와 작동에 이점이 있음을 확인하였다.

금속관 내부의 음압유량 향상을 위한 기하학적 디자인 및 SLIPS 윤활 (Geometrical Design and SLIPS Lubrication for Enhancement of Negative-pressure-driven Internal Flow Rate in Metal Pipes)

  • 김동근;장창환;김성재;김대겸;김산하
    • Tribology and Lubricants
    • /
    • 제37권6호
    • /
    • pp.253-260
    • /
    • 2021
  • Metal pipes are used in a wide range of applications, from plumbing systems of large construction sites to small devices such as medical tools. When a liquid is enforced to flow through a metal pipe, a higher flow rate is beneficial for higher efficiency. Using high pressures can enhance the flow rate yet can be harmful for medical applications. Thus, we consider an optimal geometrical design to increase the flow rate in medical devices. In this study, we focus on cannulas, which are widely used small metal pipes for surgical procedures, such as liposuction. We characterize the internal flow rate driven by a negative pressure and explore its dependence on the key design parameters. We quantitatively analyze the suction characteristics for each design variable by conducting computational fluid dynamics simulations. In addition, we build a suction performance measurement system which enables the translational motion of cannulas with pre-programmed velocity for experimental validation. The inner diameter, section geometry, and hole configuration are the design factors to be evaluated. The effect of the inner diameter dominates over that of section geometry and hole configuration. In addition, the circular tube shape provides the maximum flow rate among the elliptical geometries. Once the flow rate exceeds a critical value, the rate becomes independent of the number and width of the suction holes. Finally, we introduce a slippery liquid-infused nanoporous surface (SLIPS) coating using nanoparticles and hydrophobic lubricants that effectively improves the flow rate and antifouling property of cannulas without altering the geometrical design parameter.

돈분 퇴비화 시 공기 흡입 강도에 따른 이화학적 특성변화 (Changes of Physico-chemical Characteristic on Swine Manure Using Different Suction Strength in Composting System)

  • 이동준;김중곤;정광화;곽정훈;;이지웅
    • 유기물자원화
    • /
    • 제25권2호
    • /
    • pp.59-67
    • /
    • 2017
  • 본 연구는 톱밥이 수분조절재로 혼합된 돈분 퇴비화 시 공기 흡입 강도의 효과를 조사하기 위해 실시하였다. 25 L 규모의 퇴비화 반응기에 일정하게 주입되는 공기 주입량을 기준으로 공기 흡입량을 4 단계 (100%, 200%, 300%, 400%)로 구분하여 실험을 수행하였다. 모든 반응기의 온도가 퇴비화 개시 후 2일 이내에 호열성 단계에 도달하였으며 퇴비화 5일 까지 이를 유지하는 것을 관찰할 수 있었다. 이후 반응기의 온도는 점차 감소하여 퇴비화 실험이 끝날 무렵에는 외기와 비슷한 온도를 나타냈다. 초기 혼합원료의 수분함량은 64.27% 로 측정되었으며, 점차 감소하여 100%에서 38.4, 200%에서 33.08%, 300%에서 14.59% 그리고 400%에서 11.93로 나타났다. 퇴비화 기간 동안, pH는 6.83에서 8.67로 증가하였다가 점점 감소하여 100%, 200%에서 7.56, 300%에서 8.19, 400%에서 8.08로 관찰되었으며, 이는 100%와 200%의 공기 흡입강도가 타 처리구보다 퇴비화에 적합한 흡입조건인 것으로 사료된다. 퇴비화 초기 혼합 원료의 총 켈달질소 (TKN)는 2.3%로 측정되었으나, 점차 변화하여 퇴비화 종료 시점에 100%는 3.3%, 200%는 3.1%, 300%는 2.5%, 400%는 2.3%로 조사되었다. 이러한 결과는 100%, 200% 처리구가 타 처리구에 비해 $CO_2$ 발생 및 수증기 휘발로 인한 중량손실이 높기 때문인 것으로 사료된다. 퇴비화 초기 혼합원료의 C/N비는 25.17로 측정되었으며 급격히 감소하여 퇴비화 종료 시점에는 100%에서 11.88 200%에서 11.97, 300%에서 14.31, 400%에서 14.72로 조사되었으나 처리구 간 큰 차이는 발견되지 않았다. 이상의 연구 결과 양질 퇴비화를 위한 공기 주입량 대비 최적 공기 흡입 강도는 100%와 200% 처리구인 것으로 조사되었다.

Computed Radiography 영상에서 Parameter에 의한 Artifact 원인과 해결방안 (Cause and Solution of an Artifact Generation by Parameter in Computed Radiography System)

  • 동경래;최준구;홍성일
    • 한국콘텐츠학회논문지
    • /
    • 제9권5호
    • /
    • pp.145-155
    • /
    • 2009
  • CR방식의 도입으로 인해 많은 장점을 가지게 되었으나 기존의 Film/Screen방식에서 발생되지 않았던 Artifact가 새롭게 발생하였다. 따라서 본 논문에서는 광주에 위치한 일개 종합병원에서 획득한 CR 영상 중 Artifact가 발생한 경우를 3가지로 나누어 측정하였다. 시간 지연과 농도변화에 의한 Artifact는 시간이 경과할수록 자연방사선에 의한 영향으로 1일보다 5일후에 67%의 농도가 증가 되었으며 잠상퇴행에 의한 Artifact는 즉시보다 10시간 후의 빛의 방출도가 33%감소하여 시판이 경과할수록 영상의 질이 저하되었다. 술자에 의한 Artifact는 Collimation에 의한 Artifact가 53%, 기기에 의한 Artifact는 Guiding plate, Suction cup으로 인한 Artifact가 65%로 가장 많이 발생되는 것으로 나타났다. 따라서 Artifact에 대한 정확한 인식을 정기적인 점검을 통해 해결방안을 모색한다면 영상의 질 및 진료의 만족도를 높여 갈 수 있을 것이다.

재열기를 사용한 고성능 VI 사이클 열펌프의 난방 성능 특성에 관한 연구 (A Study on the Characteristics of Heating Performance of High-Performance Heat Pump with VI cycle using Re-Heater)

  • 이진국;최광환
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.69-75
    • /
    • 2015
  • In this study, the characteristics of heating performance of a high-performance air-cooled heat pump with vapor-injection(VI) cycle using re-heater was investigated experimentally. Devices used in the experiment is consist of a VI compressor, condenser, oil separator, refrigerant (economizer outlet refrigerant) re-heater, economizer, evaporator. And R410A was used as a working fluid. The experiment was conducted with two cycles(cycles A and B) for investigating heating performance. In case of cycle B, heat exchange was conducted by re-heater between outlet refrigerant of compressor and suction refrigerant of the VI system(Fig.1, re-heater). But the re-heater was not used in case of cycle A. As a result of this experiment, discharge temperature of refrigerator in compressor was shown higher value, when the cycle B was conducted, because of the heat exchange between suction refrigerant of VI cycle and outlet refrigerant of compressor in the re-heater than cycle A that was not use re-heater. it means that liquid hammer and the decrement of heating performance can be decreased by using re-heater. Also, Heating coefficient of performance(COPh) was shown about 2.98 in Cycle B which was 4% higher than Cycle A and from these results, It was confirmed that the improvement of the heating performance of heat pump with VI cycle can be achieved by applying re-heater.

히트파이프를 이용한 온풍난방기 배기열회수 시스템의 열회수 특성 (Heat Recovery Characteristics of the Exhaust Heat Recovery System with Heat Pipe Unit Attached to the Hot Air Heater in the Greenhouse)

  • 강금춘;김영중;유영선;백이;이건중
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.441-448
    • /
    • 2001
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat capacity of the oil burred. In order to recover the heat of this exhaust gas and to use for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The system consisted of a heat exchanger made of heat pipes, ø15.88${\times}$600mm located in the rectangular box of 675(L)${\times}$425(W)${\times}$370(H)mm, an air suction fan and air ducts. The number of heat pipe was 60, calculated considering the heat exchange amount between exhaust gas and air and heat transfer capacity of a heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/h depending on the inlet air temperature of 12 to -12˚at air flow rate of 1.100㎥/h. The temperature of the exhaust gas left the heat exchanger dropped to 100$^{\circ}C$ from 270$^{\circ}C$ after the heat exchange between the suction air and the exhaust gas.

  • PDF