• Title/Summary/Keyword: Suction Portion

Search Result 16, Processing Time 0.034 seconds

An Experimental Study on Reducing Condensation in Marine Air Compressors

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.3
    • /
    • pp.303-308
    • /
    • 2015
  • Compressed air has many uses on board ship, ranging from diesel engine starting to the cleaning of machinery during maintenance. In an effort to enhance the performance of the marine compressed air system, this work studied a way to reduce condensation from the air compressor via experiments. Especially more condensation is produced when the temperature at compressor outlets and the humidity of the air are higher. so in the research, drain production change has been observed by additionally installing the cooling fan on the suction portion of the air to air compressor and this is the method for reducing the compressed air drain that has passed through the compressor. For the result, it was verified that when the cooling fan was used, less drain was made where per hour it was 500.9ml of drain and the measured result after installing the cooling fan was that less drain was made. Other additional and various researches are needed including experiments like silica gel passing through the suction portion afterwards.

Effect of Rainfall-Induced Infiltration on Unsaturated Weathered Soils with Varying Clay Contents (강우시 점토함유량에 따른 화강풍화토의 불포화 침투 특성)

  • 유남동;정상섬;김재홍;박성완
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.8
    • /
    • pp.159-166
    • /
    • 2004
  • In this study, experiments on the SWCC were performed in order to find out the characteristics of unsaturated soil and to analyze the stability of unsaturated weathered slopes with rainfall-induced wetting. Several soil types classified by mixture portion of clay (CH) in the weathered soil (SW) were used in experimental tests. To achieve the SWCC, the filter paper method was used on SW with varying clay contents. A tensiometer test was used for measuring wetting front suction of the soils in a laboratory with varying relative densities. Based on the experimental results, it is shown that the wetting front suction increases as clay contest of mixture soil increases : in particular, the wetting front suction increases sharply as the clay contents increase. It is also found that wetting front suction affects the initial wetting band depth and stability of the slope.

Pneumatic Separation on Separating Unit of a Combine Harvester (콤바인 선별실(選別室)의 기류선별(氣流選別)에 관한 연구(硏究))

  • Chung, C.J.;Nam, S.I.;Joo, B.C.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.32-43
    • /
    • 1988
  • This study was attempted to investigate the pneumatic separation on separating unit of a combine harvester. The aerodynamic characteristics of threshed materials were analyzed by experiments. The air velocity distribution within the separation chamber was measured for various speeds of the winnower and suction fans to find out the operational and design conditions of the separating unit which would serve for reducing the grain loss from chaff outlet. The results of study arc summarized as follows: 1. Based on the separation curve of threshed materials analyzed, it was shown that three different kind. of materials-kernels, straw chaff, and leaf chaff were as a whole able to be separated pneumatically, regardless of varieties. However, a small amount of the separation grain loss may be expected to occur if the complete separation between kernels and straw chaff would be undertaken because some portion of their separation curve were overlapping. 2. The analysis of air velocity distribution showed that the separation chamber may be divided into two regions, the discharging and separating. The air velocity of the discharging region was 5-15 m/s and that of the separating region 2-5 m/s. 3. The air movement of the separation chamber may be a turbulence flow, being its speed became greater as it moves from the left to the right section of the separation chamber. The equi-speed line. of air flow had a steep gradient in between the discharging and the separation regions. The air velocity in the discharging region was much higher than the terminal velocity of kernels, because of which those kernels appearing in the region could be possibly exhausted as the grain loss from the chaff outlet. 4. The motion trajectory of threshed material in the separating region was dominantly affected by the winnower fan, on the other hand, its motion in the discharging region was affected by suction fan. 5. The grain loss from the chaff outlet was affected greatly by the winnower fan and the trace of kernel movement. It was observed that the optimum working speed to give minimum grain loss from chaff outlet for the combine tested should be maintained at 950~1,150 rpm for the winnower fan and 1,850 rpm for the suction fan. 6. It was shown that a large portion of grain loss from chaff outlet may occur when the kernels may bump against a portion of separation chamber wall and those kernels thus scattered into the discharging region were sucked by the suction fan. It was accordingly recommended that a new design of the wall of separation chamber so as to bump down kernels may be necessary to reduce grain loss from the chaff outlet.

  • PDF

Installation of Suction Caisson Foundation for Offshore Wind Turbine : Model Test (해상풍력타워 석션기초의 설치시 거동에 대한 모형 시험 연구)

  • Kim, Dong-Joon;Kim, Su-Rin;Choo, Yun-Wook;Kim, Dong-Soo;Lee, Man-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.825-839
    • /
    • 2010
  • The global and domestic market for offshore wind farm is expected to grow fast, and the design and installation of substructure and foundation is getting more important. As for the offshore wind farms located in the shallow(depth < 20m) water, the construction and installation of the substructure and foundation makes up about 1/4 ~1/3 of the offshore wind farm construction cost, and the portion is expected to increase because the turbine capacity is increasing from 2 ~ 3MW to 5MW or larger and the water depth of wind farms is also increasing over 30m. As a foundation for offshore wind turbine, the suction caisson foundation is being considered to be a highly competitive alternative to the conventional monopile or gravity based structure, because it has features suitable for the offshore construction such as quick installation, no heavy equipment for penetration and no hammering noise for driving. In order to study the installation behaviour of the suction caisson, laboratory tests were performed with sand. The pore water pressure and displacement were measured to analyze the suction pressure during penetration, the penetration speed and the amount of heaving.

  • PDF

Neck Clipping of Giant Aneurysm in ICA Using Intra-Operative Temporary Balloon Occlusion and Suction Decompression Technique - A Case Report - (술중 풍선 확장을 이용한 일시적 근위부 결찰과 흡입, 감압술을 실시한 내경동맥의 거대동맥류 결찰 - 증례보고 -)

  • Weon, Keun Soo;Shin, Yong Sam;Park, Han Jun;Lee, Seung Un;Yun, Su Han;Cho, Ki Hong;Cho, Kyung Gi
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.165-169
    • /
    • 2001
  • Apatient, 51 years old woman, had suffered form headache and decrease of visual acuity. She had $3{\times}3cm$ sized giant aneurysm originated in cavernous and clinoid portion of left ICA(C4,C5) in the cerebral angiography. Before craniotomy, left CCA was exposed and 6F double lumen catheter was inserted in left ICA through the sheath. Pre-operative angiography was done. balloon catheter was positioned at the petrous portion of ICA. Eyebrow approach was done and giant aneurysm was exposed. The proximal blood flow was controlled with balloon dilatation and suction and decompression was tried, then multiple clips were applied. The loss of distal blood flow under intra-operative angiography was notified after clipping. The position of clips were repositioned to preserve blood flow & the rich flow was confirmed at distal part of clipping. In the post-operative cerebral angiography, the same finding was shown.

  • PDF

Right Bochdalek hernia with pneumothorax in adult (성인에서 기흉을 동반한 우측의 Bochdalek Hernia 1)

  • 백광제
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.729-734
    • /
    • 1984
  • Bochdalek hernia is a type of congenital diaphragmatic defect in the posterolateral portion of the diaphragm. The defect is usually Lt. sided due to protective effect of liver on right. Sex distribution is male preponderance [2:1] and it is diagnosed during neonate, mostly first 24 hours, due to severe respiratory distress. We experienced a rare case of old aged female patient with congenital Bochdalek hernia on Rt. side which was found incidentally during treatment of spontaneous pneumothorax of Rt. side. 17 year old female patient was admitted to CS department for chest discomfort on right and mild dyspnea with duration of 20 days. Under the diagnosis of spontaneous pneumothorax, Rt. closed thoracostomy and underwater sealed drainage with continuous suction was applied. On follow-up chest x-ray, poorly defined hazy increased density with multiple air-fluid levels in Rt. lower lung field and Lt. subphrenic free air were noted. So, Barium enema was done under the impression of Rt. diaphragmatic hernia, and nearly entire colon proximal to sigmoid was demonstrated in the Rt. hemithorax. Operation was done-for surgical repair of defected diaphragm through Rt. posterolateral thoracotomy. Operative findings were as follows; 1.Hypoplastic Rt. lung, esp. RML & RLL. 2.Nearly entirely intestines were herniated. 3.Diaphragmatic defect was located on posterolateral portion of the diaphragm, about 10x3cm in size with blunt smooth margin. 4.A large bleb on apex of RUL of lung. Herniated intestines were repaired into abdominal cavity manually and defect of diaphragm was repaired with No. I black silk interrupted sutures directly, and bleb was resected. Postoperative courses were uneventful and the patient was discharged with good condition on POD 14th.

  • PDF

Morphological Study of the Suction Trap in Aquatic Utricularia japonica (수생형 통발(Utricularia japonica)의 흡입식 포충낭 형태 연구)

  • Kim, In-Sun
    • Applied Microscopy
    • /
    • v.40 no.2
    • /
    • pp.109-116
    • /
    • 2010
  • Morphology and microstructure of the suction trap in aquatic Utricularia japonica were examined using scanning electron microscopy. Branched stems bear numerous suction traps without root formation. The traps are derived axillary from the node, and their antennae and appendages extend in a peculiar fashion. The trap walls are thin, two-celled, parenchyma tissue and simple, small glands are scattered in both internal and external surface of the trap. The entrance of the trap is surrounded by one pair of dorsal antennae and ventral appendages, where the former guides the prey to the entrance. Trap door is situated below the entrance and numerous sessile and stalked capitate trichomes cover the entrance and even on the door surface. The capitate trichomes are secretory, but four trigger hairs formed on the central areas of the door are not. They are believed to function in activating and tripping the trap door. A specialized region of the threshold come in contact with the lower portion of the door upon closing. The secretory capitate trichomes near this region are responsible for producing and secreting a mucilage-like substance which composes the velum. Two-armed bifid glands are located in the interior side of the threshold, while four-armed quadrifid glands are considerably numerous occurring over the entire inner trap wall. Bifid and quadrifid glands develop semi-spherical basal cells that connect them to the inner wall surface. Antennae, trigger hairs, capitate trichomes, bifid and quadrifid glands are more important structures in the carnivory of U. japonica.

Aerodynamics of High Speed Trains Passing by Each Other

  • FUJII Kozo;OGAWA Takanobu
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1995.04a
    • /
    • pp.5-29
    • /
    • 1995
  • A three-dimensional flow field induced by two trains passing by each other inside a tunnel is studied based on the numerical simulation of the three-dimensional compressible Euler/Navier-Stokes equations formulated in the finite difference approximation. Domain decomposition method with the FSA(fortified solution algorithm) interface scheme is used to treat this moving-body problem. The computed resluts show basic characteristic of the flow field created when two trains passing by each other. History of the pressure distributions and the aerodynamic forces acting on the trains are mailnly discussed. The results indicate that the phenomenon is complicated due to the interaction of the flow induced by two trains. Strong side force occurs between the two trains when the front portion of the opposite train passes by. It fluctuates rapidly and maximum suction force occurs when two trains are aligned side by side. The results also indicate the effectiveness of the present numerical method for moving boundary problems.

  • PDF

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

An Experimental Study of Cryochiller System Using Autocascade (오토캐스케이드 방식을 적용한 극저온 칠러 시스템의 실험적 연구)

  • Cha, Dong-an;Kwon, Oh-kyung;Yun, Jae-ho;Kim, Dae-yeol
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1980-1985
    • /
    • 2007
  • The purpose of this study is to investigate the performance of an autocascade refrigeration system using the refrigerant mixtures of R-134a(64${\sim}$72wt%), R-23(20${\sim}$25wt%) and R-14(8${\sim}$12wt%) as working fluids by experiment. The experimental apparatus consisted of a autocascade system with a compressor, condenser, evaporator, gas-liquid separator and cascade condenser, etc. Two main causes to this failure were considered as follows. First, the pressure ratio in the compressor was extremely increased at the beginning of the experiment. Second, the outlet temperature in compressor was higher than its limited temperature. For a stable operation of the compressor, a portion of the mixed refrigerant was by-passed at the inlet of the heat exchanger and transferred directly to the suction of the compressor in the modified system. The experimental parameters were changed weight of R-134a(1800g, 2800g), R-23(700, 800, 900g) and R-14(300, 400, 500g). The results showed that the best performance in case of R-134a of 2800g, R-23 of 900g and R-14 of 500g.

  • PDF