• Title/Summary/Keyword: Subway tunnel

Search Result 381, Processing Time 0.028 seconds

Suitability Assessment and Maintenance Planning of the Guided Drainage Method on Underpass Structure (유도배수공법을 적용한 지하차도 설계 및 유지관리방안)

  • Jin, Kyu-Nam;Lee, Jung-Min;Kim, Young-Jin;Park, Jae-Hyeon;Cho, Gye-Chun
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.97-109
    • /
    • 2012
  • For the design of underpass structures, -1.0m(G.L) ground water level guideline for the design of railway, subway, utility tunnel etc, is still being used in Korea. As a result, the underpass structure can be forced by buoyancy, and therefore the in-situ buoyancy anchor method is usually being applied to prevent the uplifting force. For the Yeongjongdo sky city project, the drainage method was applied to remove the buoyancy force. In this study we estimate the efficiency and safety of the applied design and propose the detailed guidelines for standard design and maintenance of the guided drainage technique. Especially, the auxiliary pumping well was operated to maintain the ground water level around the underpass. In the study site, the applied guided drainage method has advantages in both engineering and economic aspects.

The Analysis of the Important Problems on Designing and Constructing Earth Retaining Structures (지반굴착 흙막이 구조물 설계 및 시공시 중요문제점 분석)

  • Lee, Song;Kim, Ju-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.167-174
    • /
    • 2002
  • Earth retaining structure is constructed structure in order to construct a multistoried building, the subway, a subterranean downtown for effective use and obtainments of the limited ground. Recently, many kinds of research have been actively developed for a standardization and a database on designing and constructing of bridge, tunnel, road. With the works of database construction of that, many kinds of data with respect to statistics is cumulated. However, Database work of designed and constructed earth retaining structure in the construction field is wholly lacking and lagged behind in the works of database construction. This paper suggested classification system on indication data in connection with designing and constructing earth retaining structures a hundred fields. On the basis of that, code work with classification system was practised and DB program of indication data in connection with designing and constructing earth retaining structures was developed.

Shield TBM trouble cases review and parameter study for the cause analysis (쉴드 TBM 트러블 사례 및 매개변수 연구를 통한 원인 분석)

  • Koh, Sungyil;La, You-Sung;Kim, Bumjoo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.2
    • /
    • pp.197-217
    • /
    • 2020
  • Shield TBM tunneling, used in the construction of Seoul subway line 7 and line 9, has been well known as a very efficient, as well as safe, tunneling method. Although the Shield TBM method has been known to be effectively used in poor ground conditions, a number of troubles have occurred during the use of the shield TBM, due to inappropriate machine selection, machine breakdown, and unpredicted ground conditions etc. In this study, several accidents and trouble cases occurred during excavation by Shield TBM, reported from Japan, were investigated. A series of numerical analysis was then performed to compare with the trouble cases and back-analysis results for the cause analysis. The lessons learned from the case studies are presented at the end.

Lumped Parameter Modeling and Analysis of Electromagnetic Vibration Exciter for Vibrating Rapper of Electrostatic Precipitator (전기 집진기의 진동 탈진을 위한 전자기 진동 가진기의 집중매개변수 모델링 및 해석)

  • Kim, Je-Hoon;Lee, Jung-Hun;Kim, Jin-Ho;Jeong, Sang-Hyun;Han, Bang-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.2
    • /
    • pp.61-66
    • /
    • 2011
  • The miniaturization of electrostatic precipitator is becoming a key element to the success of the efficient electrostatic precipitator due to the limited space allowed to install electrostatic precipitator in subway tunnel. Nowadays, a research on electrostatic precipitator in urban railroad equipment technology is under an active study. Finite element method has been used one of the most popular techniques, but it consumes a lot of time especially in computation iterations. Accordingly, the lumped parameter analysis can be an alternative tool to FEM because of its computation iteration capability with fair accuracy. In this paper, lumped parameter model and the simulation results are presented. In addition, the result of lumped parameter analysis is compared with those obtained from finite element analysis for verification.

A Study for Safety Management on Ground Excavation by Analysis of Accident Events (사고사례 분석을 통한 흙막이 굴착공사 안전관리 개선방안 연구)

  • Seong, Joo Hyun;Jung, Soo Hyung;Shin, Ju Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.175-183
    • /
    • 2011
  • With recent growth of population and industry, urban development grows into grand scheme of excavation and construction in urban area. As the development progress advanced, the developments get large and deepen. With a progress of technology development in geotechnical engineering in Korea, most our grand scheme of projects follows great progress. On the other hand, some excavation in construction site caused direct or indirect event that affects the adjacent or surrounding structures by excavation from time to time. This event usually happens around residential and commercial area where underground tunnel, subway station, commercial building, and high-rises excavation site is, could lead great damage on economy as well as personal injury or human casualties. In order to prevent this event, the study has to be done with analysis on various events of excavation and its cause. In this paper, the research has collected the various excavation events and their causes to analyze on each site and event to define emphasis on surrounding environment.

Logistic Regression and GIS based Urban Ground Sink Susceptibility Assessment Considering Soil Particle Loss (토립자 유실을 고려한 로지스틱 회귀분석 및 GIS 기반 도시 지반함몰 취약성 평가)

  • Suh, Jangwon;Ryu, Dong-Woo;Yum, Byoung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.2
    • /
    • pp.149-163
    • /
    • 2020
  • This paper presents a logistic regression and GIS based urban ground sink susceptibility assessment using underground facility information considering soil particle loss. In the underground environment, the particle loss due to water flow or groundwater level change leads to the occurrence and expansion of cavities, which directly affect the ground sink. Four different contributory factors were selected according to the two underground facility domains (water pipeline area, sewer pipeline area) and subway line area. The logistic regression method was used to analyze the correlation and to derive the regression equation between the ground sink inventory and the contributory factors. Based on these results, three ground sink susceptibility maps were generated. The results obtained from this study are expected to provide basic data on the area susceptible to ground sink and needed to safety monitoring.

A Study on the Absorption Performance of a Perforated Panel type of Resonator (다공패널형 공명기의 흡음성능에 관한 연구)

  • Song, Hwayoung;Yang, Yoonsang;Lee, Donghoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.224-231
    • /
    • 2016
  • When aiming to reduce the low frequency noise of a subway guest room through sound absorbing treatment methods inside the wall of a tunnel the resonator is often more effective than a porous sound absorbing material. Therefore, the perforated panel type resonator embedded with a perforated panel is proposed. The perforated panel is installed in the neck, which is then extended into the resonator cavity so that it can ensure useful volume. The absorption performance of the perforated panel type of resonator is obtained by acoustic analysis and experiment. The analytical results are in good agreement with the experimental results. In the case of multiple perforated panel type resonators, as the number of perforated panels increase, the 1st resonance frequency is moved to a low frequency band and sound absorption bandwidth is extended on the whole. In order to obtain excellent absorption performance, the impedance matching between multi-panels should be considered. When the perforated panel in the resonator is combined with a porous material, the absorption performance is highly enhanced in the anti-resonance and high frequency range. In case of the resonator inserted with perforated panels of 2, the 2nd resonance frequency is shifted to a low frequency band in proportion to the distance between perforated panels.

High Efficiency Power Amplifier applied to 5G Systems (5G 시스템에 적용되는 고효율 전력증폭기)

  • Young Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.2
    • /
    • pp.197-202
    • /
    • 2023
  • This paper presents the design method and electrical characteristics of a high-efficiency power amplifier for a 50 Watts class repeater applied to a 5G system and used in in-building, subway, and tunnel. GaN was used for the termination transistor of the power amplifier designed here, and intermodulation signals were removed using DPD to satisfy linearity. In addition, in order to handle various requirements such as amplifier gain control and alarm processing required in the 5G system, the microprocessor is designed to exist inside the power amplifier. The amplifier manufactured to confirm the electrical performance of the power amplifier satisfying these conditions satisfied 46.5 dBm and the overall efficiency of the amplifier was 37%, and it was confirmed that it satisfied various alarm conditions and electrical characteristics required by telecommunication companies.

A study on the applicability of under ground structure using steel tubular roof in Korean geotechnical condition (대구경강관을 이용한 지하구조물 축조공법의 국내지반 적용성 연구)

  • Lee, Young-Bock;Kim, Jeong-Yoon;Park, Inn-Joon;Kim, Kyong-Gon;Lee, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.4
    • /
    • pp.401-409
    • /
    • 2003
  • Recently, the development of underground structures is to be inevitably necessary due to the increase in population and traffic volume that has caused to the limit of urban land use and the heavy traffic jams. Therefore, underground structures such as subway, underground shopping centers, lifeline facilities and so on, have been increasingly constructed, On the other hand, several social problems have occurred during construction, i.e., ground subsidence, noise, and vibration. Therefore, safer and more beneficial methods for underground construction are on the demand. In this research, N.T.R.(New Tubular Roof) method has been modified and utilized for solving those problems and overcoming the difficulties connected with the bored tunnel construction of large underground openings in unfavorable ground, often under the water table, and with overburdens that are too shallow to solve problems of stability using traditional methods. The N.T.R. method has been modified to suit for Korean geotechnical conditions, and was made up for the weak points-the water leakage from walls and tops, the maintenance and the lack of stability-of the conventional methods. This paper dealt with the features and the applicability of N.T.R. Method based on the results from numerical analysis and data from in-situ monitoring system.

  • PDF

A 2-D Location Determination Model of Buried Persons in Collapsed Shape using Optimal Wireless Communication Technology (최적 무선통신 기술을 활용한 붕괴지형 매몰자의 2차원 매몰위치 결정 모델)

  • Moon, Hyoun-Seok;Lee, Woo-Sik;Lee, Gun-Woo;Han, Dong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8879-8888
    • /
    • 2015
  • When the disaster like earthquake in urban area occur, due to the collapse accidents for subway, tunnel space with buildings or underground area, enormous property and human damage are happened. Specially, since it is difficult to identify survived status of humans within collapsed debris and accurately buried locations of the humans, inputs of considerable time and manpower for rescuing them are required. Besides, secondary damage can be occurred by additional collapses. The aim of this study is to propose a stochastic location positioning method that enables to provide aid information by determining locations of mobile devices for buried persons in 2-D plane using wireless communication technologies. This study selected a detection method for buried persons based on Wi-Fi signal, and identified characteristics of signal strengths by distance unit. Using these methods, a stochastic location detection model in 2-D plane was built. It is expected that this technology will be utilized as a core technology that can protects safety and human life of the public by providing data for rescuing quickly buried persons in cases of national disasters for future.