• Title/Summary/Keyword: Subsequent extraction method

Search Result 61, Processing Time 0.025 seconds

Simple and Robust Measurement of Blood Plasma Lysophospholipids Using Liquid Chromatography Mass Spectrometry

  • Ji, Dong Yoon;Lee, Chang-Wan;Park, Se Hee;Lee, Eun Jig;Lee, Do Yup
    • Mass Spectrometry Letters
    • /
    • v.8 no.4
    • /
    • pp.109-113
    • /
    • 2017
  • Single analytical procedure including extraction, liquid chromatography, and mass spectrometric analysis was evaluated for the simultaneous measurement of lysophospholipids (LPLs). LPLs, particularly, lysophosphatidic acids (LPA) and sphingosine 1-phosphate (S1P) are lipid messengers ubiquitously found in various biological matrix. The molecular species mediate important physiological roles in association with many diseases (e.g. cancer, inflammation, and neurodegenerative disease), which emphasize the significance of the simple and reliable analytical method for biomarker discovery and molecular mechanistic understanding. Thus, we developed analytical method mainly focusing on, but not limited by those lipid species S1P and LPA using reverse phase liquid chromatography-tandem mass spectrometry (RPLC-ESI-MS-MS). Extraction method was modified based on Folch method with optimally minimal level of ionization additive (ammonium formate 10 mM and formic acid). Reverse-phase liquid-chromatography was applied for chromatographical separation in combination with negative ionization mode electrospray-coupled Orbitrap mass spectrometry. The method validation was performed on human blood plasma in a non-targeted lipid profiling manner with full-scan MS mode and data-dependent MS/MS. The proposed method presented good inter-assay precision for primary targets, S1P and LPA. Subsequent analysis of other types of LPLs identified a broad range of lysophosphatidylcholines (LPCs) and lysophosphatidyl-ethanolamines (LPEs).

Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples (환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.

Separation of Phosvitin from Egg Yolk without Using Organic Solvents

  • Jung, Samooel;Ahn, Dong Uk;Nam, Ki Chang;Kim, Hyun Joo;Jo, Cheorun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.11
    • /
    • pp.1622-1629
    • /
    • 2013
  • The objective of this study was to develop a new method to separate phosvitin from egg yolk without using organic solvents. Phosvitin was extracted from yolk granules using 10% NaCl or 10% $(NH_4)_2SO_4$ (final concentration) and then treated with heat to precipitate the lipoproteins from the extracted solution. The optimal pH for the phosvitin extraction from yolk granules was determined, and the iron-binding ability of the extracted phosvitin (final product) was tested. Adding 10% $(NH_4)_2SO_4$ disrupted the granules, and the subsequent thermal treatment at $90^{\circ}C$ for 1 h precipitated low density and high density lipoproteins, which enabled separation of phosvitin by centrifugation. The phosvitin concentration in the extract was significantly higher when the pH of the solution was adjusted to pH ${\geq}9$. The purity and recovery rate of phosvitin at the end of the separation process were approximately 78% and 56%, respectively. The separated phosvitin was confirmed to have ferrous and ferric iron binding ability. The advantages of this new method compared with the traditional methods include no organic solvents and high-priced equipment are needed for the separation. Also, this method is more environment and consumer friendly than that of the traditional methods.

An Extraction Method of Bibliographic Information from the US Patents: Using an HTML Parsing Technique (미국 특허 서지정보 추출 방법에 대한 연구: HTML 파싱 기법의 활용을 중심으로)

  • Han, Yoo-Jin;Oh, Seung-Woo
    • Journal of the Korean Society for information Management
    • /
    • v.27 no.2
    • /
    • pp.7-20
    • /
    • 2010
  • This study aims to provide a method of extracting the most recent information on US patent documents. An HTML paring technique that can directly connect to the US Patent and Trademark Office (USPTO) Web page is adopted. After obtaining a list of 50 documents through a keyword searching method, this study suggested an algorithm, using HTML parsing techniques, which can extract a patent number, an applicant, and the US patent class information. The study also revealed an algorithm by which we can extract both patents and subsequent patents using their closely connected relationship, that is a very distinctive characteristic of US patent documents. Although the proposed method has several limitations, it can supplement existing databases effectively in terms of timeliness and comprehensiveness.

The comparative study of two extraction methods for ancient DNA: silica suspension method and ultracentrifugal concentrator method (고대 유전자에 대한 두 종류의 DNA 분리 방법의 비교 연구: 실리카 현탁액 방법 및 초원심분리 농축 방법)

  • Lee, Eun-jung;Maixner, Frank;Zink, Albert
    • Analytical Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.65-70
    • /
    • 2018
  • This study compared two methods for preparing ancient DNA (aDNA) for the construction of successful shotgun libraries that may be applied to massive parallel sequencing. For the comparative analysis, the DNA of prehistoric rib samples from Hungary was extracted using either a manually prepared silica suspension or the Amicon Ultracel-15 10K ultracentrifugal device (Millipore). After the extraction of the same amount of bone powder (about 150 mg) from three samples by each method, the amount of extracted double-stranded DNA and the subsequent degree of construction of the shotgun library were analyzed. The Amicon device method was rapid and easier to perform and resulted in an approximately 11-fold higher DNA recovery than that obtained using the silica suspension. The shotgun library constructed using DNA templates prepared by the Amicon device was more successful than that constructed from templates isolated using the silica suspension. The comparative study of these two aDNA extraction methods showed that the Amicon device has the advantages of saving time, process simplicity, and high efficiency.

A Fast and Sensitive Method for the Simultaneous Determination and Quantification of Six Anionic Surfactants in Surface Water using HILIC-ESI-MS Technique

  • Dash, Upendra N.;Paul, Saroj Kumar
    • Mass Spectrometry Letters
    • /
    • v.3 no.3
    • /
    • pp.78-81
    • /
    • 2012
  • The hydrophobic hydrocarbon chain and the polar sulfate group confer surfactant properties and enable them to be used as anionic surfactants. Anionic surfactants (AS) are known for their adverse impact on environment, particularly on aquatic ecosystem. In the present study a fast, sensitive and selective method for the determination and subsequent quantification of six anionic surfactants was developed using hydrophilic interactive liquid chromatography (HILIC) coupled to a electrospray ionization (ESI) mass spectrometer (MS), in the concentration range 15-20 ${\mu}g/L$. The capability of the method was established using regression analysis and ANOVA. The method performance was evaluated by analyzing real time surface water spiked with 1-dodecyl hydrogen sulfate at 15 ${\mu}g/L$. Combined efficiency of solid phase extraction and MS detection established recovery of 89% in presence of natural matrix. These results point out that HILIC coupled to multistage MS procedures can be a powerful technique for environmental applications concerning the screening of polar contaminants.

Rapid Gas Chromatographic Screening of Saliva Samples for Organic Acids (기체크로마토그래피법에 의한 타액내 유기산의 신속한 스크리닝)

  • 김경례;김정한;박영준;김정옥
    • YAKHAK HOEJI
    • /
    • v.39 no.3
    • /
    • pp.283-288
    • /
    • 1995
  • Rapid gas chromatographic profiling method was applied to saliva from healthy subjects for the analysis of free organic acids. Saliva samples were first saturated with NaHCO$_{3}$ and extracted with diethyl ether. The aqueous phase was solid-phase extracted using Chromosorb P as the adsorbent and diethyl ether as the eluent after the acidification and NaCl saturation, followed by triethylamine treatment. The resulting tiiethylammonium salts of acids were directly converted into stable tert.-butyl-dimethylsflyl derivatives, with subsequent analysis by dual-capiuary column gas chromatography and gas chromatograpy -mass spectrometry. From the ten saliva samples studied, twenty eight free organic acids including various fatty acids, hydroxy acids, dicarboxylic acids, md aromatic acids were tentatively identified. Among the acids identified , the concentration of lactic acid was highest for five saliva samples while $\alpha$-hydroxyisocaproic acid was most abundant for me sample, and succinic acid and glycolic acid for two samples. respectively. When the GC profiles were simplified to the corresponding acid retention index spectra of bar graphical form, they presented characteristic patterns for each individual.

  • PDF

Efficient Isolation of Intact RNA from the Soft Coral Scleronephthya gracillimum $(K\ddot{u}kenthal)$ for Gene Expression Analyses

  • Woo, Seo-Nock;Yum, Seung-Shic;Yoon, Moon-Geun;Kim, Sa-Heung;Lee, Jong-Rak;Kim, Jeong-Ha;Lee, Taek-Kyun
    • Animal cells and systems
    • /
    • v.9 no.4
    • /
    • pp.205-209
    • /
    • 2005
  • A rapid, simple and efficient method to extract RNA from the adult polyps of a soft coral, marine cnidarian, Scleronephthya gracillimum $(K\ddot{u}kenthal)$; was developed in this study. The highest yield and purity of RNA was obtained with the lysis solution containing 35 mM EDTA, 0.7 M LiCl, 7.0% SDS, and 200 mM Tris-Cl (pH 9.0). Approximately $40{\mu}g$ of total RNA was extracted from 200 mg of liquid nitrogen-pulverized polyp tissue. The ratio of absorbance at 260 nm and 280 nm ranged from 1.8 to 2.0. The results of the reverse transcription polymerase chain reaction (RTPCR) with ${\beta}-actin$ gene specific primers and Northern blot analysis using the same gene probe revealed that the RNA extracted by our method had high quality, and was sufficient for subsequent molecular biological analyses. This method was effective for RNA extraction from other soft coral species which belong to the genus Dendronephthya.

Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Paper Materials (기체 크로마토그래피/질량분석기를 이용한 종이류 중 알킬페놀류, 클로로페놀류 및 비스페놀 A 정량)

  • Kim, Hyub;Kim, Jin-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.1
    • /
    • pp.45-55
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrom-etry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. Also, solid -phase extraction (SPE) with XAD -4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The SIM responses were linear with the correlation coefficient varying 0.9717 ∼ 0.9995 (isoBOC derivatization), and 0.9842 ∼ 0.9980 (TBDMS derivatization). The recoveries were 82.4 ∼ 108.8%) by area ratio of phenanthrene -d$\_$10/ vs bisphenol A-d$\^$l6/. (isoBOC derivatization and TBDMS derivatization) The range of concentrations was respectively, 0.95 ∼ 1.44 ng/g in 2,4-dichlorophenol, 1.01 ∼ 1.17 ng/g in t-butylphenol,2.17 ∼ 5.84 ng/g in pentachlorophenol, 12.68 ∼ 14.88 ng/g in nonylphenol and 30.84 ∼ 153.72 ng/g in bisphenol A.

Trace Analysis as TBDMS Derivatives of Organic Acids in Aqueous Samples (TBDMS 유도체로서 수용액 시료중의 유기산 미량분석 연구)

  • Kim, Gyeong Rye;Kim, Jeong Han;Park, Hyeong Guk
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.352-359
    • /
    • 1990
  • An effecient gas chromatographic method is described to be used routinely for the rapid profiling and identification of biochemically important organic acids. It involves the solid-phase extraction of organic acids from aqueous samples using Chromosorb P as the solid sorbent and diethyl ether as the eluting solvent, with subsequent triethylamine treatment. The resulting triethylammonium salts of acids were directly converted to volatile tert-butyldimethylsiyl derivatives, which were simultaneously analyzed by two capillary columns of different polarity, DB-5 and DB-1701, under the identical temperature programming condition. The retention index (RI) and area ratio (AR) values of each peak measured on DB-5 and DB-1701 enabled rapid identification of acids by computer RI library search and AR comparison. The application of the present method to the organic acid profiling of various complex samples is demonstrated.

  • PDF