• 제목/요약/키워드: Submerged-flat

검색결과 57건 처리시간 0.019초

평막을 이용한 침지형 막여과시스템에서 고농도 분말활성탄 주입에 의한 수처리성능 개선 효과 (The Effects of PAC (Powdered Activated Carbon) on Water Treatment Performance of an Immersed Membrane System Using Flat-sheet Membrane Module)

  • 가이샹쥐안;김한승
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.195-201
    • /
    • 2007
  • A submerged flat-sheet membrane separation system integrated with PAC (powdered activated carbon) was used in this research in order to investigate the effects of PAC on the efficiencies of operation and treatment and to evaluate the performance of the system. The experiments were carried out under operating conditions of a filtration rate of 0.38 m/d, water temperature of $20-28^{\circ}C$, and PAC dose of 0 g/L (Run-A) and 20 g/L (Run-B). The influent concentrations of TOC (total organic carbon), $NH_4{^+}-N$ (ammonia nitrogen) and $UV_{254}$ (UV absorbance at 254 nm) were 2.48 mg/L, 1.4 mg/L and 2.53 1/m, respectively. TOC removal of 43.2 and 73.6%, ammonia nitrogen removal of 4.9 and 15.9%, and $UV_{254}$ removal of 20.6 and 31.6% were obtained for Run-A and Run-B, respectively. During an experimental period of 33 days, no change was found in TMP (Run-B), but the TMP in Run-A increased by 5 kPa after 29 days. This research showed that the filtrate quality and the performance efficiency were enhanced when PAC was introduced into the filtration system.

몰수형 피치댐핑포일 주위 유동의 PIV 해석 (PIV Analysis of Flow around a Submerged Pitch Damping Foil)

  • 김옥석;이경우
    • 대한조선학회논문집
    • /
    • 제49권5호
    • /
    • pp.410-415
    • /
    • 2012
  • An experimental study is carried out to investigate the near-wake characteristics of a NACA 0018 foil with a flat plate. Two-frame grey-level cross correlation PIV method is used to measure the local flow characteristic around a pitch damping foil to control the vertical motion of high speed crafts in a circulating water channel. The analysis also includes angles of attack 10 and 20 degrees respectively. Reynolds number $Re{\fallingdotseq}3.5{\times}10^4$ based on the chord length(C=100mm) of NACA0018 has been applied during the whole experiments. The distance between the foil and the flat plate is D/C=0.5, 1.0 and 1.5 respectively. The channel effect according as the distance between the foil and the flat plate has a close relation with the velocity distributions around the foil. In the wake of 20-degree of attack, the complex turbulent flow and a thick boundary layer are formed due to the processes of vortex generation and dissipation.

$ENVIS^{(R)}$ MEMBRANE SYSTEM (평판형 정밀여과막)의 침지식 수처리 공정 적용에 관한 연구 (Application of $ENVIS^{(R)}$ MEMBRANE SYSTEM (Sumerged flat Sheet MF Membrane))

  • 이영무;장재영
    • 멤브레인
    • /
    • 제15권3호
    • /
    • pp.241-246
    • /
    • 2005
  • 본 연구는 하수 및 오폐수 처리를 위해 침지식 수처리 공정 적용을 위한 평판형 MF막인 $ENVIS^{(R)}$을 이용한 MBR SYSTEM 적용에 관한 연구이다. (주)퓨어엔비텍에서 만든 장치를 이용하여 공장의 오수시설($10\;m^3$/일)과 폐수처리장($30\;m^3$/일) 현장에서 실험을 수행한 결과, 공장 오수처리에 있어 제거율은 각각 SS $99.7\%$, BOD $97.6\%$, COD $96.8\%$였으며, 폐수처리에 있어 제거율은 각각 SS $99.6\%$, BOD $95.6\%$, COD $80.3\%$였다.

활성슬러지 케이크의 분리막 오염 모델 (Membrane Fouling Models for Activated Sludge Cakes)

  • 김대천;정건용
    • 멤브레인
    • /
    • 제24권3호
    • /
    • pp.249-257
    • /
    • 2014
  • 본 실험은 실험실적 규모의 침지식 평막형 분리막이 장착된 활성슬러지 생물반응기에 인공폐수를 사용하여 수행하였다. 분리막 운전은 MLSS 5,000 mg/L 활성슬러지 용액을 일정 유량으로 계속 투과시키는 방식과 주기적으로 10분여과/2분휴지 방식으로 구분하여 실시하였다. 산기량은 0.25 L/min로 일정하게 유지한 상태에서 투과유속을 10에서 $25L/m^2{\cdot}hr$까지 증가시키면서 막간차압을 측정하였다. 또한 분리막 오염 상태를 판단하기 위하여 완전막힘, 표준막힘, 중간막힘, 비압축성 케이크 및 선형압축성 케이크 오염 모델을 실험값에 적용하였다. 10분운전/2분휴지 운전방식에서는 매 주기마다 펄스형태로 막간차압이 변화하므로 최고점 및 최저점 연결선으로 구분하여 막오염 모델을 적용하였다. 활성슬러지 케이크 막오염은 이상의 5가지 오염 모델 중 선형압축성 케이크 오염 모델이 모든 투과실험 결과와 가장 잘 일치하였다.

침지식 평판형 연속회분식 박반응기에서 유입 유기물 부하의 변화에 따른 영양염류의 제거 특성 (Nutrient Removal Characteristics on Organic Material Loadings in Submerged Flat Sheet Type Sequencing Batch Membrane Reactor)

  • 김승건;이호원;강영주
    • 멤브레인
    • /
    • 제20권3호
    • /
    • pp.241-248
    • /
    • 2010
  • $0.4\;{\mu}m$의 세공크기를 갖고 있는 평막이 침지된 연속회분식 반응기에서 유입 유기물 농도가 영양염류 제거에 미치는 영향을 조사하였다. 분리막의 여과성능과 영양염류 제거효과를 규명하기 위하여 유입 유기물의 농도를 200 mg/L (Run-1), 400 mg/L (Run-2) 및 800 mg/L (Run-3)로 연속적으로 변화시키면서 실험하였다. COD/N 및 COD/P의 비가 증가할수록 T-N 및 T-P의 제거율은 모두 증가하였다. Run-1, Run-2 및 Run-3에서 T-N의 평균 제거율은 각각 28.1, 32.6 및 90.4%이었으며, 투과수의 T-N 평균 농도는 각각 32.0, 30.0 및 4.3 mg/L 이었다. 또한 Run-1, Run-2 및 Run-3에서 T-P의 평균 제거율은 각각 13.6, 35.3 및 93.1%이었으며, 투과수의 T-P 평균 농도는 각각 3.11, 2.33 및 0.25 mg/L이었다.

프레스-브레이킹 굽힘 공정을 이용한 SAW 후육강관의 외경 예측을 위한 해석적 연구 (Numerical Prediction of the Outer Diameter for SAW Pipes Formed by Press-Brake Bending)

  • 박기범;강병권;강범수;구태완
    • 소성∙가공
    • /
    • 제25권2호
    • /
    • pp.116-123
    • /
    • 2016
  • Press-brake bending is used to shape flat and thick plates into a targeted circular configuration without excessive localized thinning or thickening. A brake bending press called 'a knife press bending apparatus' has been widely adopted to manufacture thick, large and long pipe from initially thick plate. Submerged Arc Welded (SAW) pipes are also produced by employing press-brake bending. These pipes are mainly used for oil, natural gas and water pipelines. The principal process variables for press-brake bending can be summarized as stroke of the press-brake knife, the distance between both roll in the lower die, and the feeding length of the plate. Many combinations of these process variables are available, thus various pipe diameters can be realized. In the current study, a series of repetitive numerical simulations by feeding a thick plate with initial thickness of 25.4mm were conducted with the consideration of elastic recovery. Furthermore, an index for SAW pipe production is proposed which can be widely used in industry.

Performance of a submerged membrane bioreactor for wastewater mimicking fish meal processing effluent

  • Lopez, Guadalupe;Almendariz, Francisco J.;Heran, Marc;Lesage, Geoffroy;Perez, Sergio
    • Membrane and Water Treatment
    • /
    • 제9권4호
    • /
    • pp.263-271
    • /
    • 2018
  • The objective of this work was to analyze organic matter removal, nitrification, biomass growth and membrane fouling in a submerged flat-sheet membrane bioreactor, fed with synthetic wastewater, of similar composition to the effluents generated in a fish meal industry. After biomass acclimatization with saline conditions of 12 gNaCl/L and COD/N ratio of 15 in the bioreactor, results showed that the organic matter removal was higher than 90%, for all organic loading rates (0.8, 1, 1.33 and $2gCOD/L{\cdot}d$) and nitrogen loading rates (0.053, 0.067, 0.089 and $0.133gN/L{\cdot}d$) tested during the study. However, nitrification was only carried out with the lowest OLR ($0.8gCOD/L{\cdot}d$) and NLR ($0.053gN/L{\cdot}d$). An excessive concentration of organic matter in the wastewater appears as a limiting factor to this process' operating conditions, where nitrification values of 65% were reached, including nitrogen assimilation to produce biomass. The analysis of membrane fouling showed that the bio-cake formation at the membrane surface is the most impacting mechanism responsible of this phenomenon and it was demonstrated that organic and nitrogen loading rates variations affected membrane fouling rate.

침지형 막결합 연속회분식 반응기의 운전에서 폐수의 도입단계가 제거효율과 여과성능에 미치는 영향 (The Effect of Filling Step on the Removal Efficiency and Filtration Performance in the Operation of Submerged Membrane-Coupled Sequencing Batch Reactor)

  • 김승건;이호원;강영주
    • 멤브레인
    • /
    • 제21권3호
    • /
    • pp.263-269
    • /
    • 2011
  • 침지식 막결합형 연속회분식 생물반응기에서 폐수의 도입단계가 제거효율과 여과성능에 미치는 영향을 조사하였다. 호기성 단계의 초기에 공급할 경우(Mode-1)와 무산소 단계의 초기에 공급할 경우(Mode-2)에 대하여 89일 동안 동시에 운전하였다. COD 제거효율과 여과성능은 2가지 운전방식 간에 큰 차이가 없었다. 그러나 영양염류(총질소와 총인)의 제거효율에 있어서 Mode-2가 Mode-1에 비해 보다 효과적이었다. Mode-2의 경우 COD, 총질소 및 총인의 제거율은 각각 99.1, 73.3 및 77.7%이었다.

평면 충돌제트에서 노즐 깃이 단상 및 비등 열전달에 미치는 영향 (The Effect of Nozzle Collar on Single Phase and Boiling Heat Transfer by Planar Impinging Jet)

  • 신창환;임성환;우성제;조형희
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.878-885
    • /
    • 2005
  • The water jet impingement cooling is one of the techniques to remove the heat from high heat flux equipments. Local heat transfer of the confined water impinging jet and the effect of nozzle collar to enhance the heat transfer are investigated in the fee surface jet and submerged jet. Boiling is initiated from the farthest downstream and increase of the wall temperature is reduced with developing boiling, forming the flat temperature distributions. The reduction in the nozzle-to-surface distance fur H/W$\le$1 causes significant increases and distribution changes of heat transfer. Developed boiling reduces the differences of heat transfer for various conditions. The nozzle collar is employed at the nozzle exit. The distances from heated surface to nozzle collar, Hc are 0.25W, 0.5W and 1.0W. The liquid film thickness is reduced and the velocity of wall jet increases as decreased spacing of collar to heated surface. Heat transfer is enhanced fur region from the stagnation to x/W$\~$8 in the free surface jet and to x/W$\~$5 in the submerged jet. For nucleate boiling region of further downstream, the heat transfer by the nozzle collar is decreased in submerged jet comparing with higher velocity condition. It is because the increased velocity by collar is de-accelerated downstream.

평면 충돌제트에서 노즐 깃이 단상 및 비등 열전달에 미치는 영향 (The Effect of Nozzle Collar on Single Phase and Boiling Heat Transfer by Planar Impinging Jet)

  • 신창환;임성환;우성제;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1452-1457
    • /
    • 2004
  • The water jet impingement cooling is one of the techniques to remove heat from high heat flux equipments. We investigate the local heat transfer of the confined water impinging jet and the effect of nozzle collar to enhance the heat transfer in the free surface jet and submerged jet. Boiling is initiated from the furthest downstream and the wall temperature increase is reduced with developing boiling, forming the flat temperature distributions. The reduction in the nozzle-to-surface distance for $H/W{\leq}1$ causes the significant increases and distribution changes in heat transfer. Developed boiling reduces the differences in heat transfer for various conditions. The nozzle collar is employed at the nozzle exit. The distances from heated surface to guide plate, $H_c$ are 0.25W, 0.5W and 1.0W. The liquid film thickness is reduced and the velocity of wall jet increase as decreased spacing of collar to heated surface. Heat transfer is enhanced for region from the stagnation to $x/W{\sim}8$ in the free surface jet and to $x/W{\sim}5$ in the submerged jet. For nucleate boiling region of further downstream, the heat transfer by the nozzle collar is decreased in submerged jet compare with higher velocity condition. It is because the increased velocity by collar is de-accelerated at downstream.

  • PDF