• Title/Summary/Keyword: Submerged marine structure

Search Result 48, Processing Time 0.027 seconds

Shoreline Changes Caused by the Construction of Coastal Erosion Control Structure at the Youngrang Coast in Sockcho, East Korea (속초 영랑해안 해빈침식대책 인공구조물 건설에 기인하는 해안선 변화)

  • Kang, Yoon-Koo;Park, Hyo-Bong;Yoon, Han-Sam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.4
    • /
    • pp.296-304
    • /
    • 2010
  • The shoreline change caused by the construction of shore protection structures are discussed based on the example of Youngrang coast, Sokcho where the coastal erosion control system(CECS), three artificial headlands and two submerged breakwaters are being constructed. The study qualitatively analyzed the shoreline changes of Youngrang coast using available satellite/aerial photographs and camera photographs taken during the construction period of 6 years since 2002 for the artificial headlands construction. The main results from the study are as following. (1) Before the installation of the middle artificial headland, longshore drifts along Youngrang coast are transported in the NW-SE direction according to the seasonally different wave characteristics. (2) During the CECS construction the shoreline is continuously changed by altering the local longshore drift budget. Especially, the middle artificial headland induces considerable change of shoreline by blocking the sediment supply from the southern pocket beach to the northern pocket beach and by accelerating the sediment accretion at the wave shadow zone behind its head. It induces the asymmetry on the net longshore drift causing the significant erosion at the center of the southern pocket beach. (3) The study demonstrates that serious unintended erosion/accretion problem are possibly occurred due to local changes on the wave transformation and the sediment transport by the construction of coastal erosion control system.

Engineering Performance and Applicability of Eco-Friendly Concrete for Artificial Reefs Using Electric Arc Furnace Slags (전기로 슬래그를 활용한 인공리프용 친환경콘크리트의 공학적 성능 및 적용성)

  • Jo, Young-Jin;Choi, Se-Hyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.533-544
    • /
    • 2015
  • Unlike the concrete structure built on land, that exposed to the marine environment is greatly degraded in durability due to the exposure to not only the physical action caused by sea wind, tide, and wave, but also the harsh conditions, including the chemical erosion and freeze-thaw which result from $SO_4{^{2-}}$, $Cl^-$ and $Mg^{2+}$ ions in seawater. In the process of the large scaled construction of submerged concrete structures, of course environmental hazardous substance, such as alkaline (pH) and heavy metals, may be leached. Thus, this issue needs to be adequately reviewed and studied. Therefore, this study attempted to develop a CSA (Calcium Sulfo Aluminate) activator using electric arc furnace reducing slags, as well as the eco-friendly concrete for artificial reefs using electric arc furnace oxidizing slag as aggregate for concrete. The strength properties of the eco-friendly concrete exposed to the marine environment were lower than those of the normal concrete by curing 28 days. This suggest that additional studies are needed to improve the early strength of the eco-friendly concrete. With respect to seawater resistance of the eco-friendly concrete, the average strength loss against 1 year of curing days reached 8-9%. the eco-friendly concrete using high volume of ground granulated blast furnace slags and high specific gravity of electronic arc furnace oxidizing slag demonstrated the sufficient usability as a freeze-thaw resistant material. With respect to heavy metal leaching properties of the eco-friendly concrete, heavy metal substances were immobilized by chemical bonding in the curing process through the hydration of concrete. Thus, heavy metal substances were neither identified at or below environmental hazard criteria nor detected, suggesting that the eco-friendly concrete is safe in terms of leaching of hazardous substances.

Review of the Structural Shape for Aft Transition Ring of Submarine (잠수함 함미 트랜지션 링 구조 형상에 대한 고찰)

  • Oh, Dohan;Ahn, Namhyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.936-944
    • /
    • 2019
  • Submarines, which have been called an invisible force, are strategic underwater weapon systems that perform missions such as anti-surface warfare, anti-submarine warfare, and high payoff target strikes with the advantage of underwater covertness. A submarine should be able to withstand the hydrostatic pressure of the deep sea. In this respect, the submarine pressure hull, as the main structural system to resist the external pressure corresponding to the submerged depth, should ensure the survivability from hazards and threats such as leakage, fires, shock, explosion, etc. To do this, the initial scantling of the submarine pressure hull must be calculated appropriately in the concept design phase. The shape of the aft transition ring varies according to its connection with the submarine aft end conical structure, pressure hull cylindrical part, and non-pressure hull of the submarine; the design of the aft transition ring should not only take into account stress flow and connectivity but also the cost increase due to the increased man-hours of its complex geometry. Therefore, trade-off studies based on the four different shapes of the aft transition ring are carried out considering both the review of the structural strength through nonlinear finite element analysis (FEA) and economic feasibility by reviewing the estimations of the manufacturing working days and material costs. Finally, the most rational structural aft transition ring shape for a submarine amongst four reviewed types was proposed.

Mechanical Characteristics of Kaolin-cement Mixture (카올린-시멘트 혼합재료의 공학적 특성)

  • Lee, Kyu-Hwan;Lee, Song;Yi, Chang-Tok
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.1
    • /
    • pp.113-125
    • /
    • 2002
  • Ground improvement technique of cement stabilization via Deep Soil Mixing with dry cement is gaining popularity, particularly in Japan and other parts of Southeast Asia and in Scandinavia. Cement can be mixed with deep soft clay deposits, typical of marine environments, to improve the bearing capacity and/or reduce the compressibility of the material so that an otherwise poor site can be developed. However, the strength/deformation behaviour and resulting soil structure of the clay-cement mixture is presently not well understood with respect to both dry and wet mix methods. An extensive laboratory test was carried out to determine the mechanical characteristics of kaolin-cement, with some brief examination of the effects of curing environment. Laboratory tests include triaxial tests, unconfined compression tests, isotropic consolidation testis and oedometer tests. Cement contents up to 10 percent were considered and water curing was employed. Samples were cured for 7 to 112 days while submerged in distilled water. Conventional laboratory tests were also performed. In this paper, the laboratory testing program is described and various sample preparation techniques are discussed. Preliminary triaxial compression test results and trends at varying moisture contents, cement contents, confining pressures and curing times will be presented.

A Study on Correlation Between Accelerated Corrosion Test and Long-term Exposure Test According to the Temperature Condition (온도조건에 따른 철근부식 촉진시험과 장기폭로시험의 상관성에 관한 연구)

  • Park, Sang-Soon;So, Byung-Tak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.203-208
    • /
    • 2016
  • In this study, to clarify the differences rebar corrosion beginning, through the actual corrosion accelerated test in corrosion time and laboratory test chamber of the structure of the marine environment results in both environments, it is an object of correlation coefficient derived. The accelerated corrosion test was carried out by two case, I.e., one is $20^{\circ}C$ of low temperaure codition(case 1), and the other is $65^{\circ}C$ of high temperaute codition(case 2). Whether corroions occurs, it was measures using half-cell potential method. The results indicated that case 2 is to acclerate the corrosion of rebar about 1.7~1.8 times as compared with case 1, thenthe corrosion of rebar embadded in concrete occurred according to the order of OPC60, FA, BS, OPC35. Correlation coefficient between acclerated corrosion test and long-term exposure test, case 1 is 2.45 to 2.94, and case 2 is 4.37~4.99.

Anti-Corrosion Property of Geopolymer Evaluated by an Impressed Current Cathodic Protection Method, Exposed to Marine Environment (염해환경에서 외부전원법에 의한 지오폴리머 시험체 보강철근의 방식특성 평가)

  • Lee, Hae-Seung;Cho, Ggu-Hwan;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.397-405
    • /
    • 2014
  • There are many literatures reporting that the service life of re-bars in concrete structures is reduced in the oceanic environment due to chloride attack. To solve this problem, this study used geo-polymer as a mix material for concrete to increase its resistance to salt damage, and the external voltage method, one of the electric methods, is was applied to evaluate the likelihood of re-bars in the oceanic structure being exposed to the extreme salt environment. The items evaluated include the natural potential of re-bars and the corrosion rate. The results of the tests showed that in all of the salt environmental conditions (submerged zone, tidal zone, and crack), the tested materials were remarkably effective compared with ordinary concrete. The corrosion protective property was found not only in the evaluation of the natural potential but also in the evaluation of the corrosion rate, suggesting that the external voltage method can be used stably for geo-polymer RC structures in an extreme salt environment.

The Ammonia Removal Capacity of a Few Kinds of Filter Media in a Water Reuse quaculture System (순환 여과식 양식 시설에 이용될 수종의 여과 재료의 효능에 관한 연구)

  • KIM In-Bae;KIM Pyong-Kih;CHEE Young-Ok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.6
    • /
    • pp.561-567
    • /
    • 1987
  • The purpose of this study was to find out the removal capacity of harmful ammonia by different filter media in the submerged biological filters in a given space of chamber. Four materials, pile cloth, corrugated skylight roofing plate, embossed plastic plate, and gravel, were used as the experimental filter media. Each filter medium was placed in two aquariums, each aquarium measuring $90cm\times60cm\times60cm\;(depth)$. Under the normal operating condition, the average of mean ammonia removal rates during the first and second functioning periods by each filter material which occupied tile space in the filter chamber (aquarium) was as follows: 1. Pile cloth: $8.381\;g{\cdot}m^{-3}.\;day^{-1}$ 2. Corrugated skylight roofing plate: $7.834\;g{\cdot}m^{-3}.\;day^{-1}$ 3. Embossed plastic plate: $7.797\;g{\cdot}m^{-3}.\;day^{-1}$ 4. Gravel: $7.051\;g{\cdot}m^{-3}.\;day^{-1}$ Thus, there were no significant differences between the media, but at the time of practical application of these materials, some other factors such as investment cost, easiness for the removal of excess detritus accumulated in tile interstices of filter media, etc. should be fallen into consideration. When large units are required, in particular, removal of excess detritus from tile gravel bed is extremely difficult, and in case of pile cloth filters the installation work is much complicated and a problem in supporting the structure when drained also exists. In these respects, corrugated skylight roofing plate and embossed plastic plate seem to be more optimal, but again in practice the local situation for the availability and the price of the materials should be rechecked and the fitness of tile materials in the particular filter chambers under use or under consideration for construction must be taken into account.

  • PDF

Characteristics of Fish Fauna and Community Structure in Yongdam Reservoir by Inhabiting Environment Changes (서식환경이 변화된 용담호의 어류상 및 어류군집 특성)

  • Yang, Sang-Geun;Cho, Yong-Chul;Yang, Hyun;Kang, Eon-Jong
    • Korean Journal of Environmental Biology
    • /
    • v.30 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • From April to November 2009, we performed field investigation to survey the characteristics of fish fauna and fish community structure inhabited in Yongdam reservoir in the upper Geumgang, which is changed into flat-water zone from flow-water zone by blocking the continuity by the gigantic submerged weir built in the upstream of Geumgang. 15 species belonging to 8 families were collected from natural habitat (St. 1) where its natural characteristics is well preserved, and 11 species were korean endemic fish species. 24 species belonging to 10 families were collected at the down region of Yongdam dam (St. 3), which might be affected by the change of water environment due to the dam, and 11 species were korean endemic fish species. On the other hand, 20 species belonging to 7 families were collected inside Yongdam reservoir (St. 2) which is changed into flat-water zone from flow-water zone by the dam reservoir, and 6 species were korean endemic fish species. In the dam reservoir, due to Yongdam dam built in the upper Geumgang, the original flow-water zone fish such as $Acheilognathus$ $koreensis$, $Pseudopungtungia$ $nigra$, $Coreoleuciscus$ $splendidus$, and $Gobiobotia$ $macrocephala$ were disappeared, and instead, the kinds of fish habitating in the flat-water zone tend to increase rapidly, such as $Carassius$ $auratus$, $Opsarichthys$ $uncirostris$ $amurensis$, $Hemiculter$ $eigenmanni$, $Zacco$ $platypus$, and $Lepomis$ $macrochirus$. Relative abundance of the insective fish was 66.7% at St. 1, 40.0% at St. 2, and 54.2% at St. 3. In order to preserve endemic fish species and aquatic ecosystem, it is desirable to minimize the artificial installation in the upper river, such as a large scale dam which can affect the habitat and if inevitable, it is required to prepare preservation measures when building facilities.