• 제목/요약/키워드: Sublimation Model

검색결과 29건 처리시간 0.024초

모델 식품으로 젤라틴 매트릭스에서 동결과정에 따른 얼음 결정체 변화 (Changes in Ice Dendrite Size during Freezing Process in Gelatin Matrix as a Model Food System)

  • 민상기;홍근표;최미정
    • 한국축산식품학회지
    • /
    • 제28권3호
    • /
    • pp.312-318
    • /
    • 2008
  • The objective of this study was to investigate the changes in ice dendrite size during freezing process in gelatin matrix as a model food system in order to provide mathematical relation between freezing condition and ice dendrite size. Gelatin gel as a model matrix was frozen in unidirectional Neumann's type of heat transfer. The thermograms' analysis allowed to determine the freezing temperature of the sample, the position of the freezing front versus time, and thus, freezing front rate. The morphology of ice dendrites was observed by scanning electron microscopy after freeze-drying. We observed that the means size of ice dendrite increased with the distance to the cooling plate; however, it decreased with the cooling rate and the cooling temperature. In addition, the shorter durations of the freeze-drying process was shorter decreeing the decreased the freezing front rate, resulted in their resulting in a larger pore size of the ice dendrite pores for the sublimation channel of that operate as water vapor sublimation channels. From these results, we could derive a linear regression as an empirical mathematical model equation between the ice dendrite size and the inverse of freezing front rate.

Heat Transfer Enhancement for Fin-Tube Heat Exchanger Using Vortex Generators

  • Yoo, Seong-Yeon;Park, Dong-Seong;Chung, Min-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제16권1호
    • /
    • pp.109-115
    • /
    • 2002
  • Vortex generators are fabricated on the fin surface of a fin-tube heat exchanger to augment the convective heat transfer. In addition to horseshoe vortices formed naturally around the tube of the fin-tube heat exchanger, longitudinal vortices are artificially created on the fin surface by vortex generators. The purpose of this study is to investigate the local heat transfer phenomena in the fin-tube heat exchangers with and without vortex generators, and to evaluate the effect of vortices on the heat transfer enhancement. Naphthalene sublimation technique is employed to measure local mass transfer coefficients, then analogy equation between heat and mass transfer is used to calculate heat transfer coefficients. Experiments are performed for the model of fin -circular tube heat exchangers with and without vortex generators, and of fin-flat tube heat exchangers with and without vortex generators. Average heat transfer coefficients of finn-flat tube heat exchanger without vertex generator are much lower than those of fin-circular tube heat exchanger. On the other hand, fin-flat tube heat exchanger with vortex generators has much higher heat transfer value than conventional fin-circular tube heat exchanger At the same time, pressure losses for four types of heat exchanger is measured and compared.

Local and Overall Heat Transfer Characteristics of Fin- Flat Tube Heat Exchanger with Vortex Generators

  • Yoo, Seong-Yeon;Chung, Min-Ho;Park, Dong-Seong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.150-157
    • /
    • 2003
  • Local and overall heat transfer characteristics of fin-flat tube heat exchangers with and without vortex generators were investigated. Local heat transfer coefficients were measured with the heat exchanger model using naphthalene sublimation technique. In case of a fin-flat tube heat exchanger without vortex generators, only the horseshoe vortices formed around tubes augment the heat transfer. On the other hand, longitudinal vortices created artificially by vortex generators additionally enhance heat transfer in case of a fin-flat tube heat exchanger with vortex generators. Overall heat transfer coefficients were measured with the prototypes of the fin-flat tube heat exchanger with and without vortex generators in a wind tunnel and results were compared with those of a fin-circular tube heat exchanger with wavy fin. Friction losses for heat exchangers were also measured and compared. The fin-flat tube heat exchanger with vortex generators is found to be more effective than the fin-circular tube heat exchanger with wavy fin.

납작관형 핀-관 열교환기의 국소 및 총합 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Local and Overall Heat Transfer Characteristics of a Fin-Flat Tube Heat Exchanger)

  • 유성연;정민호;박동성;이상섭
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.939-947
    • /
    • 2002
  • Local and overall heat transfer characteristics of fin-flat tube heat exchangers with and without vortex generators are investigated. Local heat transfer coefficients are measured with the heat exchanger model using naphthalene sublimation technique. In case of a fin-flat tube heat exchanger without vortex generators, only the horseshoe vortices formed around tubes augment the heat transfer. On the other hand, longitudinal vortices created artificially by vortex generators enhance heat transfer dramatically in case of a fin-flat tube heat exchanger with vortex generators. Overall heat transfer coefficients are measured with the prototype of the fin-flat tube heat exchanger with and without vortex generators in a wind tunnel and results are compared with those of a fin-circular tube heat exchanger with wavy fin. Friction losses for heat exchangers are also measured and compared. The fin-flat tube heat exchanger with vortex generators is found to be more effective than the fin-circular tube heat exchanger with wavy fin.

동시 스퍼터법으로 제작한 Bi 초전도 박막의 성장 모델 (Growth Model of Bi-Superconducting Thin Film Fabricated by Co-sputtering Method)

  • Chun, Min-Woo;Park, Yong-Pil
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 추계종합학술대회
    • /
    • pp.796-799
    • /
    • 2002
  • BSCCO thin films are fabricated via a co-deposition process at an ultra-low growth rate using ion beam sputtering. The sticking coefficient of Bi element exhibits a characteristic temperature dependence. This temperature dependence of the sticking coefficient was explained consistently on the basis of the evaporation and sublimation processes of Bi$_2$O$_3$.

  • PDF

부분 모델을 이용한 접촉하중을 받는 코팅층이 있는 부재의 열적/기계적 응력해석 (Thermo-Mechanica1 Stress Analyses of Part with Coated Layer under Contact Load Using Partial Model)

  • 권영두;김석삼;신세현;추상우
    • Tribology and Lubricants
    • /
    • 제18권3호
    • /
    • pp.228-234
    • /
    • 2002
  • Generally, space structures are subjected to severe situations, such as, sublimation, strong evaporation of lubricants, thermal stresses, high temperature gradients, irradiation, impacts by microscopic meteorites, and other factors. Recent]y, various kinds of coatings are applied to the parts under heavy contact stresses, in order to insure long wear-free lives and/or reduce friction coefficients. In space structures, molybdenum disulfide is using frequently. Moreover TiN, Al$_2$O$_3$, PTFE(Poly Tetra Fluor Ethylene) are introduced recently for space structure. In this part we are going to apply the partial model method, developed in reference[11] to analyze part with coated layer. In referencer[l1], we compute the reasonable size of partial model and aspect ratio. Using these data, we analyze the structures coated with TiN, Al$_2$O$_3$, PTFE under contact load, temperature and crack model . Beside, we consider the stress analysis under time dependent load and transient thermal effect.

Convection in the growth of zinc telluride single crystal by physical vapor transport

  • Kim, Geug-Tae
    • 한국결정성장학회지
    • /
    • 제13권4호
    • /
    • pp.187-198
    • /
    • 2003
  • Zinc selenide (ZnSe) single crystals hold promise for many electro-optics, acousto-optic and green laser generation applications. This material is prepared in closed ampoules by the physical vapor transport (PVT) growth method based on the dissociative sublimation. We investigate the effects of diffusive-convection on the crystal growth rate of ZnSe with a low vapor pressure system in a horizontal configuration. Our results show that for the ratios of partial pressures, s=0.2 and 2.9, the growth rate increases with the Peclet number and the temperature differences between the source and crystal. As the ratio of partial pressures approaches the stoichiometric value of 2, the rate increases. The mass fluk based on one dimensional (1D model) flow for low vapor pressure system fall within the range of the predictions (2D model) obtained by solving the coupled set of conservation equations, which indicates the flow fields would be advective-diffusive. Therefore, the rate and the flow fields are independent of gravity acceleration levels.

A Recent Dust Ejection from an Inner Mainbelt Asteroid

  • Ishiguro, Masateru;JeongAhn, Youngmin;Lee, Hee-Jae;Geem, Jooyeon;Kwon, Yuna G.;Seo, Jinguk;Im, Myungshin;Lee, Myung Gyoon;Pyo, Jeonghyun;Choi, Young-Jun;Yang, Hongu;Sekiguchi, Tomohiko;Nakamura, Akiko M.;Hasegawa, Sunao;Ohtsuka, Katsuhito;Moon, Hong-Kyu
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.63.3-63.3
    • /
    • 2019
  • Active asteroids are celestial bodies that distinctively have asteroid-like orbital elements but show comet-like activity. They exhibit the activities due to the sublimation of volatile ices, impacts with small objects or break-up by rapid rotations. As of 2019 February, 30 active asteroids are detected in the outer main belt (i.e., the semimajor axes a>2.5 au) while only 3 of them in the inner main belt (a<2.5 au), suggesting that sublimation of remaining icy volatiles can be one of the most fundamental mechanisms for the activities. A sudden activity of (6478) Gault was reported in early 2019. The asteroid was discovered in 1988 and has exhibited its inactive appearance until the end of last year. Soon after the report, we have conducted imaging observations using the Seoul National University Observatory 1.0-m telescope and the Korea Microlensing Telescope Network (KMTNet) to monitor the activity. The observed images showed a primary dust tail that consists of dust grains ejected early November in 2018. Later, another tail developed, indicating further dust ejection occurred around late December 2018. Our model simulation to reproduce the morphology of the dust cloud suggests that the slightly-curved primary dust tail results from a continuous dust ejection over weeks. The total mass of ejecta was estimated to XX kg (XX% of the asteroid mass). Such continuous dust ejection for the inner active asteroids was unexpected because ice might have already sublimated from subsurfaces of inner main belt. Based on our observational evidence, we will discuss how inner asteroids are activated and eject dust continuously.

  • PDF

핵연료 집합체에서의 열유동 특성에 관한 연구 (A Study on Thermal-hydraulic Characteristics for Nuclear Fuel Rod Bundle)

  • 유성연;정민호;김만웅;최영준;김현군
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.3-8
    • /
    • 2001
  • For the successful design of nuclear reactor, it is very important to investigate thermal-hydraulic characteristics of fuel rod bundle. Fluid flow and heat transfer in the non-circular cross-section of nuclear fuel rod bundle are different from those found in common circular tube. And complex three dimensional flow including secondary and vortex flow, is formed around the bundles. The purpose of this research is to examine how geometries and flow conditions affect heat transfer in fuel rod bundle. Design data for nuclear fuel rod bundle and structure are surveyed, and $3{\times}3$ sub-channel model is adopted in this study. Computational results are compared with the heat transfer data measured by naphthalene sublimation method, and numerical analysis and evaluation are performed at various design conditions and flow conditions.

  • PDF

Mathematical Relationship between Ice Dendrite Size and Freezing Conditions in Tuna

  • Choi, Mi-Jung;Hong, Geun-Pyo;In, Dae-Sik;Min, Sang-Gi
    • Food Science and Biotechnology
    • /
    • 제18권2호
    • /
    • pp.330-335
    • /
    • 2009
  • The principal objective of this study was to investigate changes in ice dendrite size during the freezing of tuna, in order to formulate a mathematical model of ice dendrite size. The tuna was frozen via a uni-directional heat transfer. Thermogram analysis allowed us to determine the position of the freezing front versus time, which is referred to as the freezing front rate. The morphology of the ice dendrites was assessed via scanning electron microscopy after freeze-drying, and the retained pore size was measured as ice dendrites. We noted that the mean size of ice dendrites increased with the distance to the cooling plate; however, it decreased with reductions in the cooling rate and the cooling temperature. In addition, shorter durations of the freeze-drying process decreased the freezing front rate, resulting in a larger size of the ice dendrite pores that operate as water vapor sublimation channels. According to our results, we could derive a linear regression as an empirical mathematical model equation between the ice dendrite size and the inverse of the freezing front rate.