• 제목/요약/키워드: Subjective comfort

검색결과 295건 처리시간 0.027초

고온 다습한 환경에서의 주관적 착용 쾌적감과 관련 물성 변인 (Subjective Evaluation of Wear Comfort and Related Physical Variables under Warm and Humid Condition)

  • 김정화;홍경희;조승식
    • 한국의류학회지
    • /
    • 제21권6호
    • /
    • pp.1021-1030
    • /
    • 1997
  • Physical variables related to the subjective evaluation of wear comfort were explored. Experimental fabrics was those used in the previous paper where subjective sensations of women's thin shirts were reported. Fabrics include 100% cotton (unfinished), 100% cotton (water repellent finished), cotton/polyester 35/65 (unfinished), cotton/polyester 35/65 (peach skin finished), 100% polyester fabric(plain), 100% polyester crepe. Among various physical properties of the experimental fabrics, heat 8E moisture transport properties and surface properties were chosen as important variables based on the regression coefficient. Especially, humidity at the microclimate in dynamic mode was highly correlated to the subjective evaluation and appeared to be a sensitive physical predictor, compared to dry thermal transmission rate or water vapor transmission rate. Surface characteristic parameters, however, did not show consistant trend in the prediction of the human's subjective sensation. Interaction between surface properties and humidity measurement was also observed.

  • PDF

승차감 관련 주관평가와 객관평가의 상관성 연구 (Correlation between Subjective and Objective Assessments of Ride Comfort)

  • 김민석;김연태;문원길;안세진;유완석
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.56-62
    • /
    • 2007
  • In order to compare subjective and objective assessments, a passenger car was driven at several speeds over several road profiles. To measure the acceleration signals experienced by the seated subject who provided an subjective assessment, four triaxial translational accelerometers and one triaxial gyro sensor were mounted on the steering wheel and on the passenger seat and floor, respectively. Correlations were determined between the measured accelerations and the subjective assessments of 3 expert subjects and 9 general subjects using psychophysical power law.

고온 다습한 환경에서의 주관적 착용 쾌적감 평가도구 개발을 위한 기초 연구 -Fuzzy 이론의 적용방법과 요인분석 방법간의 비교- (A Study of Development of Evaluation Technique for the Subjective Clothing Comfort in Hot-humid Environment -Comparision between the utilization of Fuzzy theory and Factor Analysis-)

  • 김정화;조승식
    • 한국의류학회지
    • /
    • 제20권2호
    • /
    • pp.362-372
    • /
    • 1996
  • Recently, need for the development of the quantification of subjective evaluation is growing for the production of high-touch and high-tech textile products. In this study, Fuzzy theory is utilized for the evaluation of the wear comfort of the various blouses. Result of a new evaluation method and factor scores, validity of the new evalution technique adopted fuzzy theory was crosschecked with the results of fator analysis and factor scores. As results, fuzzy theory was proved to be adequate methodology to objectify the subjective evaluation of the adequacy of clothing which is worn. When DUNCAN'S multiple comparion among median of the fuzzy composite score were compared with the results of factor score, the sensitivity of the test methods tends to increase. Therefore, it is suggested that fuzzy weighted checklist is an alternative evaluation scale for the subjective comparison of the textile products. In addition, individual median of fuzzy composite score value should be treated by statistical for the sensitive analysis of subjective evalution.

  • PDF

Clinical comparison of intraoral CMOS and PSP detectors in terms of time efficiency, patient comfort, and subjective image quality

  • Kamburoglu, Kivanc;Samunahmetoglu, Ercin;Eratam, Nejlan;Sonmez, Gul;Karahan, Sevilay
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.93-101
    • /
    • 2022
  • Purpose: This study compared the effectiveness of complementary metal-oxide semiconductors (CMOS) and photostimulable phosphor (PSP) plates as intraoral imaging systems in terms of time efficacy, patient comfort, and subjective image quality assessment in real clinical settings. Materials and Methods: Fifty-eight patients (25 women and 33 men) were included. Patients were referred for a full-mouth radiological examination including 1 bitewing radiograph (left and right) and 8 periapical radiographs for each side (left maxilla/mandible and right maxilla/mandible). For each patient, 1 side of the dental arch was radiographed using a CMOS detector, whereas the other side was radiographed using a PSP detector, ensuring an equal number of left and right arches imaged by each detector. Clinical application time, comfort/pain, and subjective image quality were assessed for each detector. Continuous variables were summarized as mean±standard deviation. Differences between detectors were evaluated using repeated-measures analysis of variance. P<0.05 was accepted as significant. Results: The mean total time required for all imaging procedures with the CMOS detector was significantly lower than the mean total time required for imaging procedures with PSP (P<0.05). The overall mean patient comfort scores for the CMOS and PSP detectors were 4.57 and 4.48, respectively, without a statistically significant difference (P>0.05). The performance of both observers in subjectively assessing structures was significantly higher when using CMOS images than when using PSP images for all regions (P<0.05). Conclusion: The CMOS detector was found to be superior to the PSP detector in terms of clinical time efficacy and subjective image quality.

태권도복 소재의 성능 및 착용감의 개선을 위한 연구 (A Study on the Improvement in Performances and Wearing Sensation of Textiles for Taekwondo Wears)

  • 전영민;박정희;최정화
    • 한국의류학회지
    • /
    • 제27권1호
    • /
    • pp.134-142
    • /
    • 2003
  • Performances of Taekwondo fabrics were evaluated in respect of fiber component. yarn count, weave structure and wearing comfort. As a beginning step, we investigated the present situation of Taekwondo wears by questionnaire from pro and amateur Taekwondo players. Samples employed in this study were cotton/nylon blend fabric that was newly woven for this study as well as fabrics of current Taekwondo wears for sale in the market. Their fundamental properties measured were such as air permeability, water vapor transport. wickability, absorption rate, Qmax values, thermal conductivity, durability, hand value, and etc. In addition, subjective wearing sensations were evaluated using Taekwondo wears made of those fabrics. From the results of the objective measurement and the subjective wearing test, we estimated the total fitness of fabrics as a Taekwondo wear. From the questionnaire we could see that pro players and amateurs wanted highly absorbing, quick drying, and soft-tough and complained abrasive surfaces and static elasticity of current fabrics. In view of the results so far achieved, nylon blended fabrics newly woven in this study, showed better comfort-related properties from both of the objective and subjective tests. It was also represented that finer yams enhanced water absorption and touch, and fabrics with rough surface such as honeycomb weave was superior in wearing comfort as well as aesthetic appearance.

중년 여성의 감성 Brassiere 개발(제1보) -소비자 요구 분석을 기초로 한 제품 디자인 요소 추출- (Development of Sensible Brassiere for Middle Aged Women -Investigation of consumer's Needs and Evaluation of Commercial Brassiere for the Development of Subjective Measurement Scale and Screening of Design Parameters-)

  • 김정화;이선영;홍경희
    • 한국의류학회지
    • /
    • 제24권5호
    • /
    • pp.714-723
    • /
    • 2000
  • The purpose of this study is to develop functional and sensible brassiere for middle-aged women. As a methodology, engineering design process, especially, QFD(Quality Function Deployment) was adopted to translate consumer's needs into product design parameters. Wearing tests of commercial brassiere were performed for the development o subjective measurement scale. The environmental condition was controlled at 28$\pm$1$^{\circ}C$, 65$\pm$3%RH. As results, subjective measurement scale and dimension for the evaluation of sensible brassiere were extracted from factor analysis. Four factors were fitting, aesthetic property, pressure sensation, displacement of brassiere due to movement. Regression equations with the subjective evaluation descriptors were developed for the prediction of wearing comfort of brassiere. (R2=.82) The most critical design parameter was wire-related property and second one was stretchability of main material of brassiere. Also, wearing comfort of brassiere was affected by the interaction of initial stretchability of wing and support of strap.

  • PDF

Effect of Different Types of Firefighter Station Uniforms on Wearer Mobility using Range of Motion and Electromyography Evidence

  • Son, Su-Young
    • 한국의류산업학회지
    • /
    • 제21권2호
    • /
    • pp.209-219
    • /
    • 2019
  • This study analyzed and compared wearer mobility for different types of clothing that also included the potential to develop firefighter station uniforms using range of motion (ROM) and electromyography (EMG). This study focused on a comparison of wearer mobility affected by different materials and shapes of the station uniforms worn under firefighter turnout gear. Japanese standard uniform (UNI), stretch-wear (ST), and compression-wear (CP) were used as station uniforms for the experiment. This study analyzed wearer movements and quantified ROM and EMG. In addition, the subjective evaluation of wearer mobility and comfort were assessed for comparisons. Nine healthy male students participated in the experiment. Wearer mobility was analyzed using ROM and EMG data obtained by measuring five motions; in addition, subjective evaluations were also obtained. As compared with the standard station uniform, ROM increased 6.8 % and 7.2 % due to stretch-wear and compression-wear. The benefits of wearing stretch material or compression material to improve muscle performance (such as reduced percent of maximum voluntary contraction) were not proven. Differences between materials and designs influenced subjective wearer comfort. In particular, the wearing of compression materials was shown best in terms of wearer comfort that may also allow greater wearer mobility.

안감용 직물의 태와 착용 쾌적성 평가 (Evaluation of Comfort and Hand Characteristics of Lining Fabrics)

  • 심현섭
    • 한국의류산업학회지
    • /
    • 제10권4호
    • /
    • pp.537-543
    • /
    • 2008
  • The purpose of this study was to evaluate the comfort and fabric hand characteristics of selected lining fabrics made of acetate and polyester. The comfort of the linings was determined by human subjects wearing suit blazers constructed with different lining materials in an environmental chamber controlled at $30.6^{\circ}C$ air temperature and 50% relative humidity. The hand characteristics of the lining fabrics were determined by five trained panelists using standard fabric reference samples. The effect of lining fabrics on the subjects' thermal sensations was not statistically significant. But the subjects voted warmer when wearing the polyester surah lined blazer or the polyester taffeta blazer than wearing the acetate blazers. The results of the subjective comfort evaluation indicated that, in general, the subjects rated the acetate linings significantly less sticky, clammy, damp, and non-absorbent than the polyester linings. Acetate surah was rated a little higher than the other acetate fabrics on these comfort descriptors. The results of the subjective hand evaluation indicated that the lining fabrics rated low on the geometric and mechanical hand characteristics and rated moderate on noise. Acetate surah scored the highest on most of the hand characteristics, whereas, polyester taffeta scored the lowest.

흙집의 하절기 실내 물리적 환경 특성과 온열감에 관한 연구 (A Study on the Indoor Climate Characteristics and Thermal Sensation Vote of the Earthen House in Summer Season)

  • 국찬;전지현;신용규
    • 한국주거학회논문집
    • /
    • 제17권5호
    • /
    • pp.9-16
    • /
    • 2006
  • The researches on the environmental friendly buildings have carried out on the materials, environmental property, technical elements and etc., and various buildings with these green materials have built and under construction nowadays and became a new trend of the green building. And recently, new building technique which builds the wall with the soil and wood and very easy to construct (called M Earthen House) was introduced as the green building and rapidly propagated. But the research on the indoor climatic characteristics, the ability to control the environmental comfort and the influence to the human beings of these buildings are not sufficiently identified yet. In this paper, the indoor environmental characteristics and the temperature controlling ability of these buildings in summer season were measured and analysed by the Portable Indoor Air Quality Monitor(BABUC/A, LSI) measuring equipments, ana the subjective test on the thermal environment of the subjects were carried out to evaluate the thermal comfort. The results can be summarized as follows; 1) Compared to the outdoor dry bulb temp.($15.4{\sim}28.7^{\circ}C$), the indoor temp. was $19.5{\sim}26.8^{\circ}C$. It showed the temperature controlling ability of the M earthen house was outstanding. And the indoor relative humidity, compared to the outdoor($45.4{\sim}100%$), was $58.1{\sim}76.4%$, it showed the humidity controlling ability of the M earthen house was also outstanding. 2) The thermal environment was evaluated as 'comfort'(neutral-slightly warm) and the humidity was also evaluated as 'comfort'(neutral-slightly humid). So, the results of the physical and subjective evaluation on the indoor thermal comfort in summer season were 'neutral' and 'comfort' coincidently, it was confirmed that the controlling ability of the indoor temperature and humidity of the M earthen house was very excellent.

직물의 친수 및 소수화 처리가 피부잔류수분량 및 쾌적감에 미치는 영향 (Effect of Hydrophilic and Hydrophobic Finishes of Fabrics on the Stratum Corneum Water Content and Comfort Properties)

  • 강수마;김은애
    • 한국의류학회지
    • /
    • 제17권1호
    • /
    • pp.151-161
    • /
    • 1993
  • The purpose of this study was to investigate the effect of hydrophilic finish for polyester (PET) fabric and hydrophobic finish for cotton fabric on the water transport and comfort properties. Polyester fabric was treated with 10% sodium hydroxide solution to impart hydrophilicity. Cotton fabric was sprayed with Scotch-gard$^{(R)}$ water and oil repellent finish to impart hydrophobicity. Porosity, air permeability, contact angle, wickability and water vapor transport rate (WVTR) were measured to determine the water transport properties of fabrics. To compare the comfort properties of treated and untreated fabrics, wear test was performed by putting fabric patches on the upper back: stratum corneum water content (SCWC), subjective wettedness and comfort rating were determined. The results were as follows: (1) The contact angle of water on treated polyester fabric was decreased and that of treated cotton fabric was increased. Also, the wickability of treated polyester fabric was increased and the wickability of cotton fabric was decreased. (2) Although each finish did not change porosity, the water vapor transport rate of treated polyester fabric was increased and that of treated cotton fabric was decreased slightly. (3) The results of stratum corneum water content measurements showed good agreement with the results of the contact angle and the wickability, i.e., the better the liquid water transport properties are, the less the stratum corneum water contents were resulted. (4) The realtionship of subjective wettedness or comfort and stratum corneum water content was independent. Therefore, it was concluded that human perception on the subjective wettedness or the comfort is affected by the skin contact of wet fabric rather than by the stratum corneum water content.

  • PDF