• Title/Summary/Keyword: Sub-miniature

Search Result 28, Processing Time 0.027 seconds

Influence of Milling Conditions on the Microstructural Characteristics and Mechanical Properties of Non-equiatomic High Entropy Alloy (밀링 조건이 고엔트로피 합금의 미세조직 및 기계적 특성에 미치는 영향)

  • Seo, Namhyuk;Jeon, Junhyub;Kim, Gwanghoon;Park, Jungbin;Son, Seung Bae;Lee, Seok-Jae
    • Journal of Powder Materials
    • /
    • v.28 no.2
    • /
    • pp.103-109
    • /
    • 2021
  • High-entropy alloys have excellent mechanical properties under extreme environments, rendering them promising candidates for next-generation structural materials. It is desirable to develop non-equiatomic high-entropy alloys that do not require many expensive or heavy elements, contrary to the requirements of typical high-entropy alloys. In this study, a non-equiatomic high-entropy alloy powder Fe49.5Mn30Co10Cr10C0.5 (at.%) is prepared by high energy ball milling and fabricated by spark plasma sintering. By combining different ball milling times and ball-to-powder ratios, we attempt to find a proper mechanical alloying condition to achieve improved mechanical properties. The milled powder and sintered specimens are examined using X-ray diffraction to investigate the progress of mechanical alloying and microstructural changes. A miniature tensile specimen after sintering is used to investigate the mechanical properties. Furthermore, quantitative analysis of the microstructure is performed using electron backscatter diffraction.

Application of Miniature Heat Pipe for Notebook PC Cooling (노트북 PC CPU 냉각용 소형 히트파이프 Packaging 연구)

  • Moon, Seok-Hwan;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.799-803
    • /
    • 2001
  • Miniature heat pipe(MHP) with woven-wired wick was used to cool the CPU of a notebook PC. The pipe with circular cross-section was pressed and bent for packaging the MHP into a notebook PC with very limited compact packaging space. A cross-sectional area of the pipe is reduced about 30% as the MHP with 4mm diameter is pressed to 2mm thickness. In the present study a performance test has been performed in order to review varying of operating performance according to pressed thickness variation and heat dissipation capacity of MHP cooling module that is packaged on a notebook PC. New wick type was considered for overcoming low heat transfer limit when MHP is pressed to thin-plate. The limiting thickness or pressing is shown to be within the range of 2mm∼2.5mm through the performance test with varying the pressing thickness. When the wall thickness of 0.4mm is reduced to 0.25mm for minimizing conductive thermal resistance through the wall of heat pipe, heat transfer limit and thermal resistance of MHP were improved about 10%. In the meantime, it is shown that the thermal resistance and heat transfer limit for the MHP with central wick type are higher than those of MHP with existing wick types. The results of performance test for MHP cooling modules with woven-wired wick to cool a notebook PC shows the stability as cooling system since T(sub)j(Temperature of Processor Junction) satisfy a demand condition of 0∼100$\^{C}$ under 11.5W of CPU heat.

Permeability of CoZrNb film with thickness (CoZrNb막의 두께에 따른 투자율의 변화)

  • Hoe, J.;Kim, Y.H.;Shin, K.H.;Sa-Gong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.443-446
    • /
    • 2001
  • MI(Magneto-Impedance) sensor which is made by thin films has significantly high detecting sensitivity in weak magnetic field. It also has a merit to be able to build in low power system. Its structure is simple, which makes it easier to prepare a miniature. In this study, its magnetic permeability and anisotropy field(H$\sub$k/) as a function of a thickness of sputtered amorphous CoZrNb thin film with high saturation magnetostriction and excellent soft magnetic property are investigated. In order to make a uniaxial anisotropy, thin film was subjected to post annealing with a static magnetic field with 1KOe intensity at 250, 300, and 320$^{\circ}C$ for 2 hour. Anisotropy field(H$\sub$k/)of thin film is measured by using MH loop tracer. Its magnetic permeability of thin film is measured over the frequency range from 1 MHz to 750MHz. It has shown that the magnetic permeability of amorphous CoZrNb thin film is decreased due to the skin effect with increasing a thickness of CoZrNb thin film, and hence its driving frequency is lowered.

  • PDF

DESIGN AND FABRICATION OF THE BEAM POSITION MONITOR FOR THE PEFP LINAC

  • Kwon, Hyeok-Jung;Kim, Han-Sung;Seol, Kyung-Tae;Ryu, Jin-Yeong;Jang, Ji-Ho;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.523-528
    • /
    • 2013
  • The beam position monitor (BPM) is an essential component for the PEFP 100-MeV linac's commissioning. A prototype stripline-type linac BPM was designedfor this purpose. The electrode aperture is 20 mm in diameter, and the electrode is 25 mm long, so it can be installed between Drift Tube Linac (DTL)101 and DTL102, which is the shortest distance. One end of the electrode is connected to the Sub Miniature Type A (SMA) feed through for signal measurement, and the other end is terminated as a short. The signal amplitude of the fundamental component was calculated and compared with that of the second harmonic component. The designed BPM was fabricated and a low-power RF test was conducted. In this paper, the design, fabrication and low power test of the BPM for the PEFP linac are presented.

Hierarchical Fuzzy Logic Controller Design for Obstacle Avoidance of a Mobile Robot (이동로봇의 장애물 회피를 위한 계층적 퍼지 제어기 설계)

  • Kim, Ki-Woong;Lee, Suk
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.319-322
    • /
    • 1995
  • This paper addresses that through the use of Fuzzy Logic Control, a reactiv behavior (e.g. avoiding obstacles on the way) are smoothly blended into one sequence of control action. In this classical problem, the aim is to guide a mobile robot along its path to avoid any static obstacles in front of it. This controller presented here uses three sub-controllers. This fuzzy controller was apply to a miniature mobile robot. This robot follows a left wall, maintining a minimum distance.

  • PDF

Internal Pipeline Exploration of an In-pipe Robot Using the Shadow of Pipe Fittings (배관요소 그림자를 이용한 배관로봇의 배관내부 탐사)

  • Lee, Jung-Sub;Lee, Dong-Hyuk;Roh, Se-Gon;Moon, Hyung-Pil;Choi, Hyouk-Ryeol
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.3
    • /
    • pp.251-261
    • /
    • 2010
  • In this paper, we introduce an internal pipeline exploration of an in-pipe robot, based on the landmark recognition system. The fittings of pipelines such as elbows and branches are used as the landmarks. The robot recognizes the landmarks with a vision system by using the shadows of the elements, which are generated by the specially designed illuminator on the robot. By using a simple image-processing, the robot can easily detect and distinguish these landmarks while recognizing the direction of the pipeline path. Simultaneously, all information for exploration is continuously recorded and used to reconstruct the map of the pipelines. The effectiveness of the proposed method is verified by real experiments using the in-pipe robot MRINSPECT V for moving inside of the miniature urban 8-inch gas pipeline structure.

Fisheye Lens for Image Processing Applications

  • Kweon, Gyeong-Il;Choi, Young-Ho;Laikin, Milton
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.79-87
    • /
    • 2008
  • We have developed a miniature fisheye lens with $190^{\circ}$ field of view operating simultaneously in the visible and the near infrared wavelengths. The modulation transfer function characteristic for the visible wavelength is sufficient for a mega-pixel-grade image sensor. The lens also has a fair resolution in the infrared wavelength region. The calibrated $f-{\theta}$ distortion is less than 5%, and the relative illumination is over 90%. In consequence, a sharp wide-angle image can be obtained which is uniform in brightness over the entire range of field angles. The real image heights for the visible and the near infrared wavelengths have been fitted to polynomial functions of incidence angle with sub-pixel accuracies. Combined with the near equidistance projection scheme of the lens, this lens can be advantageously employed in various image-processing applications requiring a wide-angle lens.

Design for a Fuse of High Durability Protection Elements for Improving the Safety of DC Current Measurement Device (직류전류측정기의 안전성 향상을 위한 고내구성 보호소자의 가용체 설계)

  • Lee, Ye Ji;Youn, Jae Seo;Cho, Sung Chul;Noh, Sung Yeo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.201-207
    • /
    • 2020
  • With the expansion in the use of DC power systems and increased need for system maintenance, the development of measurement devices for maintenance requires high stability. Of the different kinds of DC current measurement devices, the single-shot measurement device causes the input signal of the current measuring unit to initially generate a high inrush current. The high inrush current flows into the signal processor of the meter, shortening the life of the internal fuses and causing failure. Therefore, in this study, the I2t value for increasing the durability of the fuse is designed using the available wire diameter. Operating characteristics for 210~400% over-current of the rated current, which is relatively low over-current, are realized by the plating of low melting tin metal. As a result, a method of designing a fuse element for a DC power supply, which improves the safety of the DC current measurement device by blocking the failure caused by the inrush current, is presented.

External Attachment of Pop-up Satellite Archival Tag (PSAT) and Water Temperature Affect Oxygen Consumption Rate of the Olive Flounder Paralichthys olivaceus (넙치(Paralichthys olivaceus) 산소 소비율에 미치는 Pop-up Satellite Archival Tag (PSAT) 체외 부착과 수온의 영향)

  • Geun Su Lee;Pil Jun Kang;Hye Mi Park;Sung-Yong Oh
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.5
    • /
    • pp.660-666
    • /
    • 2023
  • This study aimed to examine the effect of external pop-up satellite archival tags (PSATs) attachment and water temperature on the oxygen consumption rate (OCR) of the olive flounder (mean body weight 2281.7 g). The OCRs of fish were measured under conditions of three different water temperature conditions (15, 20, and 25℃) and two different tagging methods [non-tagging, control; bio-logger external attachment with a miniature PSAT (dummy mrPAT), BEA] using a closed flow-through respirometer. The OCRs of fish linearly increased with the increase in water temperature in both the control and BEA (P<0.001); however, the OCRs of BEA were approximately 1.8-1.9 times lower than those of the control at each water temperature (P<0.001). The Q10 values of the control and BEA were the highest in the water temperature range of 15 to 20℃, but sensitivity to water temperature changes was higher in BEA than in the control. The metabolic energy loss rate (MEL) of fish increased with increasing water temperature regardless of external tagging, but the MEL of the control was higher than that of BEA (P<0.001). These results demonstrate that OCR, thermal sensitivity, and energy expenditure are all affected in adult olive flounder with external PSAT attachment.

Development and Application of Ultra Small Micro-Cone Penetrometer (초소형 마이크로콘 관입시험기의 개발 및 적용)

  • Lee, Jong-Sub;Shin, Dong-Hyun;Yoon, Hyung-Koo;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.2
    • /
    • pp.77-86
    • /
    • 2008
  • The disturbance zone and measured values are affected by the size of the penetrometer. The local value may be measured by the smaller penetrometer. An ultra small Micro-Cone penetrometer (5mm in outer diameter) is designed and manufactured to characterize soil properties with minimum disturbance during penetration tests. The tip resistance is measured by using stain gauges attached near the Micro-Cone. In addition, the friction sleeve is adopted to effectively remove the skin friction from the tip resistance. Design concern includes the installation of stain gauges, circuits, penetration systems, penetration rate, sampling rate, operating temperature, and calibration. Application tests show that the clay interface, and the soil layers consisting of clay and sand are clearly detected by the Micro-Cone. Furthermore, the cone tip resistances measured by the Micro-Cone and the miniature cone (16mm in outer diameter) are similar. Note the resolution is much higher in the Micro-Cone. This study shows that the Micro-Cone may effectively detect the soil interface with high resolution, and with minimum disturbance.