• 제목/요약/키워드: Stylet intubation tube

검색결과 3건 처리시간 0.018초

기관내삽관에서 속심일체형 삽관튜브 용이성에 관한 연구 (Validation study of integrated intubation tube with stylet(IITS) in tracheal intubation)

  • 윤형완;이재민;정지연
    • 한국응급구조학회지
    • /
    • 제23권3호
    • /
    • pp.111-121
    • /
    • 2019
  • Purpose: Difficult organs or locations or inadequate tube intubations can cause complications. There are some cases in which the tube location changes or the tube is removed due to processing inside the organ while installing the stylet or rapid stylet removal. Thus, this study aimed to evaluate and develop an integrated intubation tube with stylet (IITS) for easier intubation of organs in emergency cases and reduce complications caused by the stylet. Methods: This study used a "Laerdal Airway Management Trainer". For stylet intubation, procedure No. 14 of the national practical test protocol was followed, but the removal step was omitted. In this study, each emergency case was intubated with an IITS, in which the stylet was not inserted or removed separately even though it has the function of an organ intubation stylet. Results: The existing classic ET intubation method had a success rate of 100% and had an average intubation time of 21.75 seconds, The developed IITS method was also successful in all cases and had an average intubation time of 15.78 seconds. Conclusion: Application of an IITS is expected to reduce intubation time and decrease inappropriate depth and intubation failure due to stylet removal, therefore improving the efficiency of airway maintenance.

마네킹을 이용한 어려운 기도에서 부지 기관 내 삽관의 효과 (Effects of gum elastic bougie in intubation with difficult airway)

  • 심규식;방성환;안희정
    • 한국응급구조학회지
    • /
    • 제24권2호
    • /
    • pp.123-131
    • /
    • 2020
  • Purpose: This study aimed to find out the effectiveness of gum elastic bougies for intubation in comparison to stylet according to airway type using a manikin. Methods: The study subjects were 52 paramedic students who intubated using a Macintosh laryngoscope and compared stylet and gum elastic bougie use in a 7.5 mmID endotracheal tube, on a manikin with either normal or difficult airway. Difficult airway was made Philadelphia neck collar. Collected data included intubation time, accuracy and ease of intubation, later analyzed by frequency analysis, descriptive analysis, independent t-test, chi square test, paired t-test, and McNemar test using SPSS Statistics 18.0. Results: There was a significant difference in intubation time according to intubation device and airway type (p=.000). There was no significant difference in accuracy of intubation according to intubation device or airway type (normal airway p=1.000, difficult airway p=.052). There was a significant difference in ease of intubation scale according to intubation device and airway type (p=.000, p=.000). Conclusion: Based on the speed and ease of intubation, gum elastic bougie is recommended for intubation in patients with difficult airways such as those with cervical injury.

Subcutaneous Emphysema and Inflammation of the Neck after Tracheal Puncture by an Intubating Stylet

  • Jung, Gul;Byun, Woo-Mok;Lim, Hyung-Jun;Kim, Jong-Gyun;Kwak, Dong-Min;Lee, Deok-Hee;Kim, Sae-Yeon;Song, Sun-Ok;Seo, Il-Sook;Jee, Dae-Lim;Kim, Heung-Dae;Park, Dae-Pal
    • Journal of Yeungnam Medical Science
    • /
    • 제24권2호
    • /
    • pp.344-350
    • /
    • 2007
  • 한 41세 남자 환자가 충수돌기염 절제술을 받기 위하여 전신마취를 받았다. 삽관을 위해 후두경으로 보자, 난해한 기도삽관이 예상되어 유도자를 사용하였다. 기도삽관 중 돌출된 유도자가 기도를 손상시켰으며, 이에 의해 목에서부터 상부종격동까지의 피하기종과 목의 염증성 종창이 생겼다. 환자는 호흡곤란과 관련된 증상을 보이지 않아 호흡기의 손상을 의심하기 어려웠고, 주 증상이었던 염증성 종창에 초점을 두게 되어 진단에 차질을 빚었으나, 환자는 대증치료로 회복하였다. 유도자를 사용하여 기관내 삽관을 하는 경우 유도자의 위치를 재점검하여 유도자에 의한 기도 손상을 유발하지 않도록 유념해야 할 것이다.

  • PDF