• 제목/요약/키워드: Stud Performance Evaluation

검색결과 22건 처리시간 0.029초

이동형 수상부유식 가두리의 저항성능과 복원성능 평가 (Resistance and stability evaluation of mobile fish-cage)

  • 김효주;정성재
    • 수산해양기술연구
    • /
    • 제52권2호
    • /
    • pp.79-87
    • /
    • 2016
  • Mobile fish-cage was developed assuming a cage net with an enclosed area, which and estimated the hydrodynamic characteristics of the cage through the model experiment. Flux-shielding plates, installed in the bow were compared with the resistance test carried out by making a hole, bilge keel and stud, and basic block flow rate consisting of the results to a flat surface plate. The experimental results confirmed the improved resistance performance effect of 3~6% in the bilge keel and the stud form. To assess the stability of the fish-cage, evaluation of the stability in accordance with the stability criteria for determining the floating docks had confirmed that it satisfied the static stability performance under operating conditions at sea.

복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구 (Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar)

  • 박금성;배규웅;강현식;임서형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.109-116
    • /
    • 2007
  • 본 논문의 목적은 경량기포모르터를 충전한 스틸스터드와 복합스터드 내력벽체의 내화성능을 KS규준에 따라 평가하는데 있다. 주거용과 상업용 건물의 최소 내화 요구시간은 2시간이다. 시험 결과로부터 스틸 스터드와 복합스터드에 경량기포 모르터를 충전한 두 시험체 모두 2시간 내화 성능을 만족하는 것으로 나타났다. 또한 복합스터드 패널 시험체의 경우 내화 성능면에서 스틸 스터드 패널 시험체 보다 우수하다는 것을 정량적 평가하였다.

Full-scale experimental evaluation of a panelized brick veneer wall system under simulated wind loading

  • Liang, Jianhai;Memari, Ali M.
    • Structural Engineering and Mechanics
    • /
    • 제38권1호
    • /
    • pp.99-123
    • /
    • 2011
  • Brick veneer over steel stud backup wall is lighter and easier to construct compared to brick veneer over concrete masonry backup wall. However, due to the relatively low stiffness of the steel stud backup, the brick veneer tends to crack under wind load. This paper briefly introduces a new panelized brick veneer with steel frame backup wall system that is developed to potentially address this problem. The experimental study of the performance of this system under simulated wind loading is discussed in detail. The test setup details and the test specimens are introduced, results of major interests are presented, and performance of the new system is evaluated based on the test results.

스틸 스터드 모듈러 건축물 접합부위의 결로방지성능 개선방안 평가 (Evaluation of Condensation Resistance of Steel Stud Wall Corner Details in Modular Buildings)

  • 오지현;양시원;조봉호;김선숙
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.107-114
    • /
    • 2014
  • Modular systems are widely used in various building types including housing, dormitory, and barracks. Steel studs have many advantages over other materials as construction components of modular buildings in terms of seismic performance, durability and maintenance. However, steel stud modular systems also have weakness in condensation resistance due to high thermal conductivity of steel. The purpose of this study is to investigate the condensation resistance of steel stud wall corner details in modular buildings by thermal simulation. The condensation resistance was evaluated by temperature difference ratio according to ISO 13788. The result showed that there was little difference between the alternatives of adding cavity and insulation. Separation of interstitial steel studs showed outstanding effect on the improvement of temperature difference ratio.

대공간 교육시설 축조를 위한 프리스트레스트 보에 사용되는 접합 강재의 성능평가에 대한 연구 (A Study for Structural Capacity Evaluation of Embedded Steel Plate Connected with Prestressed Concrete Beam to Build Large Space Educational Facilities)

  • 이경훈
    • 교육녹색환경연구
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2011
  • An experimental study to evaluate structural capacity of an embedded plate connected with prestressed concrete beam was performed. Embedded steel plates and prestressed concrete beam were connected with stud-bolts at the ends of concrete beam specimens. About 1,000 kN concentrated load was applied at 450mm away from the end of beam specimen. A 3,000 kN capacity static Oil-jack was used to direct concentrated load. The maximum strain of stud-bolt recorded $90{\times}10^{-6}$(mm/mm) and wide width cracks were not founded. Any falling failures of concrete and large deformations were not founded either between steel plate and prestressed concrete specimen. As a result, construction performance can be improved using this embedded steel plate connection system apply to large space educational facilities.

Analytical performance evaluation of modified inclined studs for steel plate concrete wall subjected to cyclic loads

  • Lim, Jin-Sun;Jeong, Young-Do;Nam, Jin-Won;Kim, Chun-Ho;Yi, Seong-Tae
    • Computers and Concrete
    • /
    • 제17권2호
    • /
    • pp.227-240
    • /
    • 2016
  • An analytical study was conducted to investigate the effect of the shape and spacing of modified inclined studs used as shear connector between concrete and steel plate on the cyclic behavior of steel plate concrete (SC) shear wall. 9 different analysis cases were adopted to determine the optimized shape and spacing of stud. As the results, the skeleton curves were obtained from the load-displacement hysteresis curves, and the ultimate and yielding strengths were increased as the spacing of studs decrease. In addition, the strength of inclined studs is shown to be bigger compared to that of conventional studs. The damping ratios increased as the decrease of stiffness ratio. Finally, with decreasing the spacing distance of studs, the cumulative dissipated energy was increased and the seismic performance was improved.

Static and fatigue performance of short group studs connector in novel post-combination steel-UHPC composite deck

  • Han Xiao;Wei Wang;Chen Xu;Sheraz Abbas;Zhiping Lin
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.659-674
    • /
    • 2024
  • Casting Ultra High-Performance Concrete (UHPC) on an orthotropic steel deck and forming a composite action by connectors could improve the steel deck fatigue performance. This study presents the mechanical performance of a proposed post-combination connection between UHPC and steel, which had a low constraint effect on UHPC shrinkage. A total of 10 push-out tests were conducted for static and fatigue performance investigations. And the test results were compared with evaluation methods in codes to verify the latter's applicability. Meanwhile, nonlinear simulation and parametric works with material damage plasticity models were also conducted for the static and fatigue failure mechanism understanding. The static and fatigue test results both showed that fractures at stud roots and surrounding local UHPC crushes were the main failure appearances. Compared with normally arranged studs, group arrangement could result in reductions of static stud shear stiffness, strength, and fatigue lives, which were about 18%, 12%, and 27%, respectively. Compared with the test results, stud shear capacity and fatigue lives evaluations based on the codes of AASHTO, Eurocode 4, JSCE and JTG D64 could be applicable in general while the safety redundancies tended to be smaller or even insufficient for group studs. The analysis results showed that arranging studs in groups caused obviously uneven strain distributions. The severer stress concentration and larger strain ranges caused the static and fatigue performance degradations of group studs. The research outcome provides a very important basis for establishing a design method of connections in the novel post-combination steel-UHPC composite deck.

경량기포모르터와 합성한 경량형강 벽체의 전단 저항 (Shear Resistance of Light-gauge Steel Stud Wall infilled with light-weight foamed mortar)

  • 이상섭;배규웅
    • 한국강구조학회 논문집
    • /
    • 제16권4호통권71호
    • /
    • pp.397-406
    • /
    • 2004
  • 본 논문은 경량형강으로 제작한 프레임에 경량기포모르터를 채운 경량합성벽체의 전단 거동에 대한 실험 결과와 전단 강도 및 강성 평가를 제시한 것이다. 경량기포모르터는 스틸하우스 벽체의 구조 성능 및 단열 성능의 향상과 마감에 대한 시공성 개선을 위해 도입되었다. 연구 결과 단열 성능에 대한 기여도는 낮으나, 경량기포모르터의 슬러리 비중이 0.8 이상인 경우 구조 성능의 향상과 마감성이 좋은 것으로 나타났다. 본 연구에서는 전단 거동에 미치는 경량기포모르터의 영향을 알아보기 위해 경량기포모르터의 비중(0.6, 0.8, 1.0, 1.2) 벽체의 스터드 배치간격(450mm, 600mm, 900mm), 마감재(경량기포모르터, OSB, 석고보드) 및 브레이싱 등을 변수로 한 14개의 경량합성벽체를 제작하였고 비교를 위해 대표적인 스틸하우스 벽체 3개를 제작하였다. 면내전단 실험결과, 경량기포모르터를 타설한 경량합성벽체가 기존의 스틸스터드 벽체에 비해 최대 내력은 1.15~5.38배, 초기강성은 1.45~13.7배 증가한 것으로 나타났다. 또한 벽체 내부의 스터드를 900mm까지 확장하여도 무리가 없는 것으로 나타났다. 그러나 이와 같은 결과는 건조수축 균열이 억제되지 않은 상태에서 나온 것으로 경량합성벽체의 내력을 향상시키기 위해서는 경량기포모르터의 초기 건조수축균열을 억제하고 스터드와 경량기포모르터 사이의 부착력을 확보하는 것이 무엇보다도 중요한 것으로 나타났다.

이중합성 교량의 복합스터드 전단연결부의 정적강도 평가 (Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges)

  • 김현호;심창수;윤광중;이필구
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.549-559
    • /
    • 2005
  • 철도교는 강성이 주요한 설계인자이기 때문에 기존의 2거더 교량의 구조적 효율성을 높이기 위해서 이중합성 구조를 가진 철도교를 제안하였다. 일반적으로 강합성 연속교를 설계할 경우, 부모멘트 구간에 존재하는 콘크리트 바닥판은 인장에 저항하지 못한다고 가정하고 바닥판 단면을 무시하게 된다. 부모멘트 구간에서는 합성단면의 강성이 감소하게 되므로 이를 보완하기 위해 강재단면이 커지게 되는데, 이러할 경우 변단면의 적용이 불가피하게 되고 강합성형으로서의 장점이 반감된다고 할 수 있다. 이와 같은 문제점을 해결하기 위한 다양한 접근법이 존재하지만 그 중에서도 경간을 확대하고 강성이 중요한 설계인자가 되는 경우에 적절하게 사용될 수 있도록 제안된 교량의 형태가 이중합성구조이다. 따라서 본 연구에서는 이중합성 전단연결부의 거동을 파악하기 위하여 수평스터드, 수평스터드와 수직스터드가 함께 배치된 복합스터드 부재에 대한 push-out 실험을 수행하였다. 실험결과의 분석을 통하여 기존의 설계식과의 비교를 수행하고 정적 거동을 평가하였다.

철골 조립식주택 바닥판 진동 평가에 관한 연구 (A Study on Evaluation of Floor Vibration for Steel Frame Modular Housing)

  • 김종성;조민주;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.104-111
    • /
    • 2016
  • 최근 연구개발이 활발히 이루어지고 있는 철골 조립식주택은 공장에서 생산되고 현장에서 조립되는 건설방식의 특성으로 인해 일반 건축물의 철근콘크리트 바닥판과 같이 일체타설 시공되지 못하게 되며 부재 단면크기 감소 및 경량화 등으로 인해 거주자의 활동에 의한 바닥판의 수직진동 및 처짐이 사용성 평가 측면에서 중요한 문제가 될 수 있다. 따라서 이 연구에서는 대상 조립식주택에서 장변방향 보 중앙에 샛기둥이 설치된 모듈과 설치되지 않은 모듈을 대상으로 실무에서 일반적으로 사용되고 있는 AISC 설계지침서 11의 계산식(이하 AISC 계산식)을 이용하여 바닥판의 진동성능을 평가하고 범용해석프로그램을 이용한 해석결과와 비교를 통해 AISC 계산식의 적용성을 고찰하였다. 이를 토대로 샛기둥이 설치된 모듈의 바닥판에서 AISC 계산식과 해석결과의 오차가 크게 발생되는 구조적 원인을 분석하고 이를 고려하는 방안을 제시하였다. 또한 대상 조립식주택 바닥판에 대한 진동성능 향상방안을 변수로 해석모델을 수립하고 진동응답해석 및 경제성평가를 통해 진동성능과 경제성이 우수한 방안을 제시하였다.