• 제목/요약/키워드: Strut height

검색결과 30건 처리시간 0.021초

Influence of infill walls on modal expansion of distribution of effective earthquake forces in RC frame structures

  • Ucar, Taner
    • Earthquakes and Structures
    • /
    • 제18권4호
    • /
    • pp.437-449
    • /
    • 2020
  • It is quite apparent that engineering concerns related to the influence of masonry infills on seismic behavior of reinforced concrete (RC) structures is likely to remain relevant in the long term, as infill walls maintain their functionalities in construction practice. Within this framework, the present paper mainly deals with the issue in terms of modal expansion of effective earthquake forces and the resultant modal responses. An adequate determination of spatial distribution of effective earthquake forces over the height of the building is highly essential for both seismic analysis and design. The possible influence of infill walls is investigated by means of modal analyses of two-, three-, and four-bay RC frames with a number of stories ranging from 3 to 8. Both uniformly and non-uniformly infilled frames are considered in numerical analyses, where infill walls are simulated by adopting the model of equivalent compression strut. Consequently, spatial distribution of effective earthquake forces, modal static base shear force response of frames, modal responses of story shears from external excitation vector and lateral floor displacements are obtained. It is found that, infill walls and their arrangement over the height of the frame structure affect the spatial distribution of modal inertia forces, as well as the considered response quantities. Moreover, the amount of influence varies in stories, but is not very dependent to bay number of frames.

Shear behavior of steel reinforced concrete shallow floor beam: Experimental and theoretical study

  • Chen, Yang;Ren, Chong;Yuan, Yuqing;Yang, Yong
    • Steel and Composite Structures
    • /
    • 제44권5호
    • /
    • pp.677-684
    • /
    • 2022
  • This paper reports experimental investigation on shear behavior of steel reinforced concrete (SRC) shallow floor beam, where the steel shape is embedded in concrete and the high strength bolts are used to transfer the shear force along the interface between the steel shape and concrete. Six specimens were conducted aiming to provide information on shear performance and explore the shear bearing capacity of SRC shallow floor beams. The effects of the height of concrete slab, the size and the type of the steel section on shear performance of beams were also analyzed in the test. Based on the strut-and-tie model, the shear strength of the SRC shallow floor beam was proposed. Experimental results showed that composite shallow floor beam exhibited satisfactory composite behavior and all of the specimen failed in shear failure. The shear bearing capacity increased with the increasing of height of concrete slab and the size of steel shape, and the bearing capacities of beam specimens with castellated steel shape was slightly lower than those of specimens with H-shaped steel section. Furthermore, the calculations for evaluating the shear bearing capacity of SRC shallow floor beam were verified to be reasonable.

Strength and deflection prediction of double-curvature reinforced concrete squat walls

  • Bali, Ika;Hwang, Shyh-Jiann
    • Structural Engineering and Mechanics
    • /
    • 제27권4호
    • /
    • pp.501-521
    • /
    • 2007
  • This study presents a model to better understand the shear behavior of reinforced concrete walls subjected to lateral load. The scope of the study is limited to squat walls with height to length ratios not exceeding two, deformed in a double-curvature shape. This study is based on limited knowledge of the shear behavior of low-rise shear walls subjected to double-curvature bending. In this study, the wall ultimate strength is defined as the smaller of flexural and shear strengths. The flexural strength is calculated using a strength-of-material analysis, and the shear strength is predicted according to the softened strut-and-tie model. The corresponding lateral deflection of the walls is estimated by superposition of its flexibility sources of bending, shear and slip. The calculated results of the proposed procedure correlate reasonably well with previously reported experimental results.

Optimal design of spoke double-layer cable-net structures based on an energy principle

  • Ding, Mingmin;Luo, Bin;Han, Lifeng;Shi, Qianhao;Guo, Zhengxing
    • Structural Engineering and Mechanics
    • /
    • 제74권4호
    • /
    • pp.533-545
    • /
    • 2020
  • An optimal design method for a spoke double-layer cable-net structure (SDLC) is proposed in this study. Simplified calculation models of the SDLC are put forward to reveal the static responses under vertical loads and wind loads. Next, based on an energy principle, the relationship among the initial prestress level, cross-sectional areas of the components, rise height, sag height, overall displacement, and relative deformation is proposed. Moreover, a calculation model of the Foshan Center SDLC is built and optimized. Given the limited loading cases, material properties of the components, and variation ranges of the rise height and sag height, the self-weight and initial prestress level of the entire structure can be obtained. Because the self-weight of the cables decreases with increasing of the rise height and sag height, while the self-weight of the inner strut increases, the total weight of the entire structure successively exhibits a sharp reduction, a gradual decrease, a slow increase, and a sharp increase during the optimization process. For the simplified model, the optimal design corresponds to the combination of rise height and sag height that results in an appropriate prestress level of the entire structure with the minimum total weight.

Behavior of Continuous RC Deep Beams Supporting Bearing Walls

  • Lee, Han-Seon;Ko, Dong-Woo
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.581-582
    • /
    • 2009
  • Continuous deep girders which transmit the gravity load from the upper wall to lower columns have frequently long end shear spans between the boundary of the upper wall and the face of the lower column. This paper presents the results of tests and analyses performed on three 1:2.5 scale specimens with long end shear spans, (the ratios of shear-span/height : 2.0

Measurement of Critical Structures around Paraclinoidal Area : A Cadaveric Morphometric Study

  • Lee, Hyun-Woo;Park, Hyun-Seok;Yoo, Ki-Soo;Kim, Ki-Uk;Song, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권1호
    • /
    • pp.14-18
    • /
    • 2013
  • Objective : Although removal of the anterior clinoid process (ACP) is essential surgical technique, studies about quantitative measurements of the space broadening by the anterior clinoidectomy are rare. The purposes of this study are to investigate the dimension of the ACP, to quantify the improved exposure of the parasellar space after extradural anterior clinoidectomy and to measure the correlation of each structure around the paraclinoidal area. Methods : Eleven formalin-fixed Korean adult cadaveric heads were used and frontotemporal craniotomies were done bilaterally. The length of C6 segment of the internal carotid artery on its lateral and medial side and optic nerve length were checked before and after anterior clinoidectomy. The basal width and height of the ACP were measured. The relationships among the paraclinoidal structures were assessed. The origin and projection of the ophthalmic artery (OA) were investigated. Results : The mean values of intradural basal width and height of the ACP were 10.82 mm and 7.61 mm respectively. The mean length of the C6 lateral and medial side increased 49%. The mean length of optic nerve increased 97%. At the parasellar area, the lengths from the optic strut to the falciform liament, distal dural ring, origin of OA were 6.69 mm, 9.36 mm and 5.99 mm, respectively. The distance between CN III and IV was 11.06 mm. Conclusion : With the removal of ACP, exposure of the C6 segments and optic nerve can expand 49% and 97%, respectively. This technique should be among a surgeon's essential skills for treating lesions around the parasellar area.

Seismic behavior of beam-to-column connections with elliptic slit dampers

  • Shahri, Saeed Farahi;Mousavi, Seyed Roohollah
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.289-301
    • /
    • 2018
  • The rigid steel connections were suffered severe damage because of low rotational capacity during earthquakes. Hence, many investigations have been conducted on the connections of steel structures. As a solution, steel slit dampers were employed at the connections to prevent brittle failure of connections and damage of main structural members. Slit damper is a plate or a standard section with a number of slits in the web. The objective of this paper is to improve the seismic performance of steel slit dampers in the beam-to-column connection using finite element modeling. With reviewing the previous investigations, it is observed that slit dampers were commonly fractured in the end parts of the struts. This may be due to the low participation of struts middle parts in the energy dissipation. Thus, in the present study slit damper with elliptic slits is proposed in such a way that end parts of struts have more energy absorption area than struts middle parts. A parametric study is conducted to investigate the effects of geometric parameters of elliptic slit damper such as strut width, strut height and plate thickness on the seismic performance of the beam-to-column connection. The stress distribution is improved along the struts in the proposed slit damper with elliptic slits and the stress concentration is decreased in the end parts of struts. The average contributions of elliptic slit dampers, beam and other sections to the energy dissipation are about 97.19%, 2.12% and 0.69%, respectively.

Correction of the deviated tip and columella in crooked nose

  • Suh, Man-Koon
    • Archives of Plastic Surgery
    • /
    • 제47권6호
    • /
    • pp.495-504
    • /
    • 2020
  • The primary procedural components of deviated nose correction are as follows: osteotomy to correct bony deviation, septal deviation correction, manipulation of the dorsal septum to correct upper lateral cartilage deviation, and correction of functional problems (manipulation for correction of internal valve collapse and hypertrophy of the inferior turbinate). The correction of tip and nostril asymmetry cannot be overemphasized, because if tip and nostril asymmetry is not corrected, patients are unlikely to provide favorable evaluations from an aesthetic standpoint. Tip asymmetry, deviated columella, and resulting nostril asymmetry are primarily caused by lower lateral cartilage problems, which include deviation of the medial crura, discrepancy in the height of the medial crura, and asymmetry or deformity of the lateral crura. However, caudal and dorsal septal deviation, which is a more important etiology, should also be corrected. A columellar strut graft, correction of any discrepancy in the height of the medial crura, or lateral crural correction is needed to correct lower lateral cartilage deformation depending on the type. In order to correct caudal septal deviation, caudal septal shortening, repositioning, or the cut-and-suture technique are used. Surgery to correct dorsal septal deviation is performed by combining a scoring and splinting graft, a spreader graft, and/or the clocking suture technique. Moreover, when correcting a deviated nose, correction of asymmetry of the alar rim and alar base should not be overlooked to achieve tip and nostril symmetry.

근접굴착시 건물 하부 지반의 거동 (Behavior of the Ground under a Building due to Adjacent Ground Excavation)

  • 이종민
    • 한국지반공학회논문집
    • /
    • 제34권4호
    • /
    • pp.49-55
    • /
    • 2018
  • 근접굴착 시 지반변위를 억제하여 기존건물의 안정성을 확보하기 위해 굴착공사 중 흙막이벽체의 버팀대에 선행하중을 가하고 그 효과를 확인하였다. 선행하중을 가한 경우와 가하지 않은 경우에 대해서도 대형모형실험을 하였다. 지표면에 건물하중이 없는 경우와 건물하중이 있는 경우 각각 0m, 1D, 2D 에 대해 대형모형실험을 실시하였다. 본 연구에서는 모형실험에는 12m 폭의 기존건물을 축척 1:10으로 사용하였고, 폭 2m, 높이 6m, 길이 4m를 가진 대형토조에서 흙막이벽체와 인접건물의 거동에 대하여 실험을 수행하였다. 그 결과, 흙막이벽체의 버팀대에 선행하중을 작용시켜 흙막이벽체의 수평변위를 억제시켰을때 벽체배면 가상주동활동영역 내에 있는 인접건물의 안정성이 크게 향상되는 것을 확인하였다.

횡변형 방지 상세 유무 및 스트럿 형상에 따른 강재댐퍼의 성능 비교 (Performance Comparison of Steel Dampers with or without Lateral Deformation Prevention Details and Strut Shapes)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권5호
    • /
    • pp.66-73
    • /
    • 2022
  • 본 연구에서는 록킹 거동을 하는 강재댐퍼에 대한 기존 연구결과를 근간으로 스트럿 높이가 동일하고 단면적이 유사한 댐퍼 7개의 실험결과를 비교하였다. 강판댐퍼로 Ldpd(횡변형 방지 상세) 없는 SI-260, SV-260, SS-260, Ldpd 있는 I-1, V-1, S-1 및 강봉댐퍼인 R20-260을 평가하였다. 또한 단면적이 0.56배인 R15-260도 같이 평가하여, 강봉댐퍼 거동 성능을 적절히 평가하고자 하였다. 중요한 연구결과는 강판댐퍼의 일방향성을 개선한 강봉댐퍼 적용의 우수성이며, 이는 모멘트 저항 능력 및 변위비 평가에서도 확인할 수 있었다. 평가결과, 강봉댐퍼인 R20-260의 성능이 가장 우수한 것으로 평가되었다. 또한 변위비 2.0까지 변형 능력을 나타내어, 충분한 내진성능을 보유한 것으로 판단된다.