• 제목/요약/키워드: Structure Stability

검색결과 4,017건 처리시간 0.032초

Lateral stability analysis of multistory buildings using the differential transform method

  • Aydin, Suleyman;Bozdogan, Kanat Burak
    • Structural Engineering and Mechanics
    • /
    • 제57권5호
    • /
    • pp.861-876
    • /
    • 2016
  • The determination of the critical buckling load of multistory structures is important since this load is used in second order analysis. It is more realistic to determine the critical buckling load of multistory structures using the whole system instead of independent elements. In this study, a method is proposed for designating the system critical buckling load of torsion-free structures of which the load-bearing system consists of frames and shear walls. In the method presented, the multistory structure is modeled in accordance with the continuous system calculation model and the differential equation governing the stability case is solved using the differential transform method (DTM). At the end of the study, an example problem is solved to show the conformity of the presented method with the finite elements method (FEM).

Evaluation on Structural Safety for Carbon-Epoxy Composite Wing and Tail Planes of the 1.2 Ton Class WIG

  • Park, Hyunbum
    • International Journal of Aerospace System Engineering
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2019
  • In the present study, structural safety and stability on the main wing and tail planes of the 1.2 ton WIG(Wing in Ground Effect) flight vehicle, which will be a high speed maritime transportation system for the next generation, was performed. The carbon-epoxy composite material was used in design of wing structure. The skin-spar with skin-stressed structural type was adopted for improvement of lightness and structural stability. As a design procedure for this study, the design load was estimated with maximum flight load. From static strength analysis results using finite element method of the commercial codes. From the stress analysis results of the main wing, it was confirmed that the upper skin structure between the second rib and the third rib was unstable for the buckling load. Therefore in order to solve this problem, three stiffeners at the buckled region were added. After design modification, even though the weight of the wing was a little bit heavier than the target weight, the structural safety and stability was satisfied for design requirements.

Aerodynamic stability analysis of geometrically nonlinear orthotropic membrane structure with hyperbolic paraboloid in sag direction

  • Xu, Yun-ping;Zheng, Zhou-lian;Liu, Chang-jiang;Wu, Kui;Song, Wei-ju
    • Wind and Structures
    • /
    • 제26권6호
    • /
    • pp.355-367
    • /
    • 2018
  • This paper studies the aerodynamic stability of a tensioned, geometrically nonlinear orthotropic membrane structure with hyperbolic paraboloid in sag direction. Considering flow separation, the wind field around membrane structure is simulated as the superposition of a uniform flow and a continuous vortex layer. By the potential flow theory in fluid mechanics and the thin airfoil theory in aerodynamics, aerodynamic pressure acting on membrane surface can be determined. And based on the large amplitude theory of membrane and D'Alembert's principle, interaction governing equations of wind-structure are established. Then, under the circumstance of single-mode response, the Bubnov-Galerkin approximate method is applied to transform the complicated interaction governing equations into a system of second-order nonlinear differential equation with constant coefficients. Through judging the frequency characteristic of the system characteristic equation, the critical velocity of divergence instability is determined. Different parameter analysis shows that the orthotropy, geometrical nonlinearity and scantling of structure is significant for preventing destructive aerodynamic instability in membrane structures. Compared to the model without considering flow separation, it's basically consistent about the divergence instability regularities in the flow separation model.

휨 구조시스템의 구조디자인적 구성요소와 디자인 조합 수법 분석 (A Study on Design Methods and the Composition Elements in Flexure Structure Systems)

  • 이주나
    • 한국공간구조학회논문집
    • /
    • 제16권1호
    • /
    • pp.73-84
    • /
    • 2016
  • This study analyzes the four composition elements : profile, anchorage and connection, material and member rigidity, stability, as the main composition design elements of flexure structure systems, in order to explore possibilities for more various structure designs in architectures with flexure structure system. It also examines typical design methods that use the mentioned four composition elements. At the results, this research presents an understanding of the differences between funicular shape and non-funicular shape and mechanical features of the shapes in the profile element, regarding to the ratio of rise height to span length(f/l). Also, the typical design methods are presented for the designable usages of the hinge joints and the fix joints, and for the applications of member rigidity expressed by the index of the ratio of member depth to span length(d/l). And it was presented that connection styles, addition of brace members, placement of shear walls are the main design methods in the stability element. This data would be useful to architectural designs concerning integrated design with structures.

도심지 터널 근접시공에 의한 기존 지하철 구조물 안정성 평가 (Stability evaluation of existing subway structure by adjacent excavation in urban tunnelling)

  • 한상민;이동혁;박두희
    • 한국터널지하공간학회 논문집
    • /
    • 제23권5호
    • /
    • pp.339-357
    • /
    • 2021
  • 도심지에서의 교통인프라 개발이 활발해 지고, 대심도 지하터널을 이용한 도시의 기반시설 확충으로 인하여 기존 운영되거나 설치된 시설물 또는 구조물 상호 간의 근접시공이 많이 이루어지고 있다. 이에 따라 근접시공으로 인한 시설물 또는 구조물에 미치는 안정성 확보여부는 중요한 이슈가 되고 있으며, 관련법에 의하여 지하터널공사에 따른 지하안전영향 평가를 반드시 수행하여야 한다. 본 연구에서는 근접시공으로 인한 정거장구조물 의 거동특성을 파악하기 위해 동북선도시철도 터널이 계획된 노선 상부의 지하철 6호선 고려대역 정거장 구조물을 대상으로 신설터널에 의한 기존 구조물에 미치는 안전영향평가를 수행하였다. 이를 위하여 정거장구조물의 안전영역 평가 및 굴착방법에 대한 검토와 3차원 수치해석을 통한 상세검토를 수행하였다. 구조물 손상도 평가, 궤도 틀림 및 기존 구조물과 건물 안정성 평가 결과 근접터널공사에 따른 기존 정거장 구조물의 안정성은 확보되는 것으로 평가되었다. 본 연구는 도심지 터널공사에서 근접시 공시 기존의 인접구조물에 미치는 영향을 사전에 검토하는 경우 기본적인 기초 참고 자료로 활용될 수 있을 것으로 기대된다.

가스터빈 연소기내의 선회분무연소 특성 (The Characteristics of Swirl Spray Combustion in Gas Turbine Combustor)

  • 홍정구;김혁주
    • 대한기계학회논문집B
    • /
    • 제20권8호
    • /
    • pp.2721-2730
    • /
    • 1996
  • The present study conducted experimental study of spray combustion to investigate the effect of the inlet conditions of fuel and air on the flame structure, the flame stability and the characteristics of emission in the can-type model of a gas turbine combustor. In the experiment, the diameter of fuel droplet was measured using Malvern particle size analyser and temperatures in the combustion chamber were measured with R-type shielded thermocouple. In addition, flame structure was taken picture with camera and analysed. Gas analyser was also used to analyse the concentration of each components of exhausting gas. The experimental results showed that the flame condition was optimal with swirl number, 0.63 and equivalence ratio, 0.5 for controlling the flame stability, the combustion temperature and the NOx concentration. The present study concluded that both the flame structure and the emission formation were strongly affected by the swirl intensity, which selection was found as an important parameter for either stabilizing flame or lowering the quantity of NOx.

Dynamic stability of nanocomposite Mindlin pipes conveying pulsating fluid flow subjected to magnetic field

  • Esmaeili, Hemat Ali;Khaki, Mehran;Abbasi, Morteza
    • Structural Engineering and Mechanics
    • /
    • 제67권1호
    • /
    • pp.21-31
    • /
    • 2018
  • In this work, the dynamic stability of carbon nanotubes (CNTs) reinforced composite pipes conveying pulsating fluid flow is investigated. The pipe is surrounded by viscoelastic medium containing spring, shear and damper coefficients. Due to the existence of CNTs, the pipe is subjected to a 2D magnetic field. The radial induced force by pulsating fluid is obtained by the Navier-Stokes equation. The equivalent characteristics of the nanocomposite structure are calculated using Mori-Tanaka model. Based on first order shear deformation theory (FSDT) or Mindlin theory, energy method and Hamilton's principle, the motion equations are derived. Using harmonic differential quadrature method (HDQM) in conjunction with the Bolotin's method, the dynamic instability region (DIR) of the system is calculated. The effects of different parameters such as volume fraction of CNTs, magnetic field, boundary conditions, fluid velocity and geometrical parameters of pipe are shown on the DIR of the structure. Results show that with increasing volume fraction of CNTs, the DIR shifts to the higher frequency. In addition, the DIR of the structure will be happened at lower excitation frequencies with increasing the fluid velocity.

선반의 동특성 향상을 위한 구조 개선에 관한 연구 (Design Alteration of A Lathe Structure for the Improved Dynamic Stability)

  • 노승훈;이종형;손재율;이재열;이원규;이문형
    • 한국산업융합학회 논문집
    • /
    • 제12권2호
    • /
    • pp.91-97
    • /
    • 2009
  • The productivity and the precision machining are the major concerns of the machine tools, and the importance of those features will be even more emphasized with the needs of the modern industries. In this paper the dynamic properties of a lathe have been investigated through the frequency analysis test and the computer simulation to minimize the transmission of vibration generated during the machining process. The modifications have been applied to the original structure to suppress the vibration transmission and further for the structure to achieve less vibrations and higher precision machining. The result shows that the machine can have much less vibrations with simple design alterations for minor expenses, the result can also be readily applied to many similar machines for improved stability.

  • PDF

고 망간강 2상 혼합조직의 열적 안정성에 관한 연구 (A Study on the Thermal Stability of Duplex High Mn-Steel Structure)

  • 위명용
    • 열처리공학회지
    • /
    • 제5권1호
    • /
    • pp.13-22
    • /
    • 1992
  • The thermal stability of duplex high Mn-steel structure have been investigated using 15%Mn~1.0~2.4%C steels which are composed of ${\gamma}$-and ${\theta}$-phases in the range of temperature from 900 to $1100^{\circ}C$, and time from 50 to 300h. The results are as follows ; 1) The grain growth in single-phase region proceeds by grain boundary migration and the relation between mean radius $\bar{r}$ and annealing time t is described as follows ; $\bar{r}^2-{\bar{r}_0}^2=k_0{\cdot}t$ 2) The grain growth of duplex, (${\gamma}+{\theta}$), strucrure is slower than that single phase because the chemical composition of ${\gamma}$-and ${\theta}$-phases differs esch others. 3) The grain of (${\gamma}+{\theta}$) duplex structure grow slowly in a mode of Ostwald ripening. Because grain boundaries of ${\gamma}$-phase migrate under a restriction of pinning by ${\theta}$-phases. 4) In the duplex structures. the dispersed structures change to the dual-structures, as the volume fraction of the dispersed second-phase increase. Consequently, the growth-law, which is controlled by boundary-diffusion change to that of the volume diffusion-mechanism.

  • PDF

강우시 성토사면의 열차운전규제기준 (Rail Transport Operation Control for Railway Embankment under rainfall)

  • 김현기;신민호;최찬용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.225-232
    • /
    • 2009
  • Infiltration of rainfall causes railway slopes to be unstable and may result in failure. Basic relationship between the rainfall and stability of railway embankment is defined to analyze its stability by rainfall. An experimental study for defining of infiltration rate of rainfall into slope is conducted in the lab. The results of Rainfall infiltration show that rainfall infiltration is not equal to infiltration as like reservoir because rate of rainfall infiltration is controlled by slope angle. Based on these results, boundary condition of rainfall is altered and various numerical analysis are performed. The variation of shear strength, the degree of saturation and pore-water pressure for railway slope during rainfall can be predicted and the safety factor of railway slope can be expressed as the function of rainfall amount, namely rainfall index. And suggested rainfall index is compared with the rail transport operation control which is used in KORAIL. It is judged that this rainfall index can be a good tool for the rail-transport operation control.

  • PDF