• 제목/요약/키워드: Structure Analyses

검색결과 3,050건 처리시간 0.025초

Stresses analyses of shell structure with large holes

  • Tian, Zongshu;Liu, Jinsong
    • Structural Engineering and Mechanics
    • /
    • 제6권8호
    • /
    • pp.883-899
    • /
    • 1998
  • The strength, deformation and buckling of a large engineering structure consisting of four ellipsoidal shells, two cylindrical shells with stiffening ribs and large holes, one conical shell and three pairs of large flanges under external pressure, self weight and heat sinks have been analysed by using two kinds of five different finite elements - four assumed displacement finite elements (shell element with curved surfaces, axisymmetric conical shell element with variable thickness, three dimensional eccentric beam element, axisymmetric solid revolutionary element) and an assumed stress hybrid element (a 3-dimensional special element developed by authors). The compatibility between different elements is enforced. The strength analyses of the top cover and the main vessel are described in the paper.

Molecular analyses and reproductive structure to verify the generic relationships of Hypnea and Calliblepharis (Cystocloniaceae, Gigartinales), with proposal of C. saidana comb. nov.

  • Yang, Mi Yeon;Kim, Myung Sook
    • ALGAE
    • /
    • 제32권2호
    • /
    • pp.87-100
    • /
    • 2017
  • The genera Hypnea and Calliblepharis of the family Cystocloniaceae are discriminated by their female reproductive structure, especially in the formation of carposporangia and gonimoblasts. Hypnea saidana, once classified based on obsolete evidence, has not been studied phylogenetically using molecular analysis and detailed reproductive structure though it shares many morphologic features with the genus Calliblepharis. To provide better understanding of generic relationship of H. saidana with Hypnea and Calliblepharis, we carried out molecular analyses using the nuclear-encoded small subunit ribosomal DNA (SSU) and chloroplast-encoded large subunit of the RuBisCO (rbcL), and exact morphological observations focusing on the reproductive structures of wild specimens. Our molecular phylogeny showed that H. saidana is closely related to Calliblepharis, but distinct from the clade of Hypnea. Female reproductive structure of H. saidana characterized by upwardly developing chains of carposporangia, central reticulum of cell, and gonimoblast filaments not connected to the pericarp provides definite evidence to assign the taxonomic position of this species to Calliblepharis. Based on our combined molecular and morphological analyses, we have proposed Calliblepharis saidana comb. nov., expanding the distribution of Calliblepharis habitat from the eastern Atlantic South Africa, the northern Indian Ocean, Australasia, and Brazil to the western Pacific Ocean.

구조물-지반 상호작용 영향을 고려한 새로운 지반계수 평가방법에 대한 제안 (Proposed New Evaluation Method of the Site Coefficients Considering the Effects of the Structure-Soil Interaction)

  • 김용석
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.327-336
    • /
    • 2006
  • Site coefficients in IBC and KBC codes have some limits to predict the rational seismic responses of a structure, because they consider only the effect of the soil amplification without the effects of the structure-soil interaction. In this study, upper and lower limits of site coefficients are estimated through the pseudo 3-D elastic seismic response analyses of structures built on linear or nonlinear soil layers considering the structure-soil interaction effects. Soil characteristics of site classes of A, B, and C were assumed to be linear, and those of site classes of D and E were done to be nonlinear and the Ramberg-Osgood model was used to evaluate shear modulus and damping ratio of a soil layer depending on the shear wave velocity of a soil layer. Seismic analyses were performed with 12 weak or moderate earthquake records, scaled the peak acceleration to 0.1g or 0.2g and deconvoluted as earthquake records at the bedrock 30m beneath the outcrop. With the study results of the elastic seismic response analyses of structures, new standard response spectrum and upper and lower limits of the site coefficients of Fa and Fv at the short period range and the period of 1 second are suggested Including the structure-soil interaction effects.

  • PDF

Vibration measurement and vulnerability analysis of a power plant cooling system

  • Anil, Ozgur;Akbas, Sami Oguzhan;Kantar, Erkan;Gel, A. Cem
    • Smart Structures and Systems
    • /
    • 제11권2호
    • /
    • pp.199-215
    • /
    • 2013
  • During the service life of a structure, design complications and unexpected events may induce unforeseen vibrations. These vibrations can be generated by malfunctioning machinery or machines that are modified or placed without considering the original structural design because of a change in the intended use of the structure. Significant vibrations occurred at a natural gas plant cooling structure during its operation due to cavitation effect within the hydraulic system. This study presents findings obtained from the in-situ vibration measurements and following finite-element analyses of the cooling structure. Comments are made on the updated performance level and damage state of the structure using the results of these measurements and corresponding numerical analyses. An attempt was also made to assess the applicability of traditional displacement-based vulnerability estimation methods in the health monitoring of structures under vibrations with a character different from those due to seismic excitations.

Soil interaction effects on sloshing response of the elevated tanks

  • Livaoglu, Ramazan
    • Geomechanics and Engineering
    • /
    • 제5권4호
    • /
    • pp.283-297
    • /
    • 2013
  • The aim of this paper is to investigate how the soil-structure interaction affects sloshing response of the elevated tanks. For this purpose, the elevated tanks with two different types of supporting systems which are built on six different soil profiles are analyzed for both embedded and surface foundation cases. Thus, considering these six different profiles described in well-known earthquake codes as supporting medium, a series of transient analysis have been performed to assess the effect of both fluid sloshing and soil-structure interaction (SSI). Fluid-Elevated Tank-Soil/Foundation systems are modeled with the finite element (FE) technique. In these models fluid-structure interaction is taken into account by implementing Lagrangian fluid FE approximation into the general purpose structural analysis computer code ANSYS. A 3-D FE model with viscous boundary is used in the analyses of elevated tanks-soil/foundation interaction. Formed models are analyzed for embedment and no embedment cases. Finally results from analyses showed that the soil-structure interaction and the structural properties of supporting system for the elevated tanks affected the sloshing response of the fluid inside the vessel.

Assessment of 3D earthquake response of the Arhavi Highway Tunnel considering soil-structure interaction

  • Sevim, Baris
    • Computers and Concrete
    • /
    • 제11권1호
    • /
    • pp.51-61
    • /
    • 2013
  • This paper describes earthquake response of the Arhavi Highway Tunnel its geometrical properties, 3D finite element model and the linear time history analyses under a huge ground motion considering soil-structure interaction. The Arhavi Highway Tunnel is one of the tallest tunnels constructed in the Black Sea region of Turkey as part of the Coast Road Project. The tunnel has two tubes and each of them is about 1000 m tall. In the study, lineartime history analyses of the tunnel are performed applying north-south, east-west and up accelerations components of 1992 Erzincan, Turkey ground motion. In the time history analyses, Rayleigh damping coefficients are calculated using main natural frequency obtained from modal analysis. Element matrices are computed using the Gauss numerical integration technique. The Newmark method is used in the solution of the equation of motion. Because of needed too much memory for the analyses, the first 10 second of the ground motions, which is the most effective duration, is taken into account in calculations. The results obtained 3D finite element model are presented. In addition, the displacement and stress results are observed to be allowable level of the concrete material during the earthquakes.

영화 '캡틴아메리카' 시리즈에 나타난 영웅 캐릭터의 서사구조에 관한 연구 (A Study on Narrative Structure of the Hero Character in the Movie 'Captain America' Series)

  • 박찬익
    • 디지털산업정보학회논문지
    • /
    • 제15권3호
    • /
    • pp.111-118
    • /
    • 2019
  • Chapter 1 and 2 of this study examined the methodology of modern storytelling using the hero narrative structure. This involved analyses of Joseph Campbell's monomyth structure, which is the prototype model of modern storytelling and Christopher Vogler's story structure in which the monomyth structure is classified into 3 Acts and 12 Stages. In addition, the movie 'Captain America' was analyzed based on Vogler's narrative structure theory. According to the analyses results, the hero of 'Captain America' fully follows Christopher Vogler's hero narrative structure but in some cases, he does not follow the existing hero narrative structure. It is interpreted that this is because heroes of modern tales have different birth backgrounds from mythical heroes. There is also a difference even in the stage where a hero completes all adventures and returns home between modern tales and myths due to different social backgrounds. Therefore, these findings provide a basis for modification and supplementation of a modern hero epic. Through this analysis, the modified modern hero narrative structure is evaluated to be appropriate as a basic model for modern storytelling. Further, it is expected that those who frame a film script can complete a new hero epic while following the structure of syntagmatic systems by selecting a level among Northrop Frye's paragmatic systems based on this structure and considering story themes and heroes' personality and characteristics.

차체구조의 구조기인 내구 설계 (Structure Borne Durability Design of a Vehicle Body Structure)

  • 김효식;임홍재
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.109-121
    • /
    • 2004
  • This paper presents an optimal design method for structure-borne durability of a vehicle body structure. Structure-borne durability design requires a new design that can increase fatigue lives of critical areas in a structure and must prohibit transition phenomenon of critical areas that results from modification of the structure at the same time. Therefore, the optimization problem fur structure-borne durability design are consists of an objective function and design constraints of 2 types; type 1-constraint that increases fatigue lives of the critical areas to the required design limits and type 2-constraint that prohibits transition phenomenon of critical areas. The durability design problem is generally dynamic because a designer must consider the dynamic behavior such as fatigue analyses according to the structure modification during the optimal design process. This design scheme, however, requires such high computational cost that the design method cannot be applicable. For the purpose of efficiency of the durability design, we presents a method which carry out the equivalent static design problem instead of the dynamic one. In the proposed method, dynamic design constraints for fatigue life, are replaced to the equivalent static design constraints for stress/strain coefficients. The equivalent static design constraints are computed from static or eigen-value analyses. We carry out an optimal design for structure-borne durability of the newly developed bus and verify the effectiveness of the proposed method by examination of the result.

케이슨식 방파제 지반-구조 경계부 손상식별을 위한 실험적 모드분석 (Experimental Modal Analysis for Damage Identification in Foundation-Structure Interface of Caisson-type Breakwater)

  • 이소영;이소라;김정태
    • 한국해양공학회지
    • /
    • 제26권1호
    • /
    • pp.34-40
    • /
    • 2012
  • This paper presents an experimental modal analysis of a caisson-type breakwater to produce basic information for the structural health assessment of a caisson structure. To achieve the objective, the following approaches are implemented. First, modal analysis methods are selected to examine the modal characteristics of a caisson structure. Second, experimental modal analyses are performed using finite element analyses and lab-scale model tests. Third, damage scenarios that include several damage levels in a foundation-structure interface are designed. Finally, the effects of damage on the modal characteristics are analyzed for the purpose of utilizing them for damage identification.

지진하중에 대한 지하철구조물의 비선형 시간영역해석 (Nonlinear Time-Domain Analysis of Underground Subway Structure Subjected to Seismic Loadings)

  • 김재민;이중건
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.163-170
    • /
    • 2001
  • This paper presents results of nonlinear analyses for underground structures including both the soil-structure interaction and nonlinear behavior of concrete material. For this purpose, a hybrid method is employed, in which a dynamic analysis technique for a linear soil-structure interaction system and a general purpose FE program are combined in hybrid and practical manners. A couple of nonlinear analyses are carried out for framed structures in multi-layered half space soil medium. The yielding of concrete structure is considered by a multi-linear stress- strain relationship. The numerical results suggest that ductile design fur the intermediate columns in the underground framed structure is substantially important in aseismic design.

  • PDF