• 제목/요약/키워드: Structural Performance Test

검색결과 2,146건 처리시간 0.034초

조립식 좌굴방지가새형 이력댐퍼의 초기형상설계에 따른 구조성능실험 (Structural Performance Test according to Initial shape design of PF-BRB)

  • 김유성;이준호
    • 한국공간구조학회논문집
    • /
    • 제23권4호
    • /
    • pp.71-79
    • /
    • 2023
  • In this study, a prefabricated buckling brace (PF-BRB) was proposed, and a test specimen was manufactured based on the design formula for the initial shape and structural performance tests were performed. As a result of the experiment, all standard performance requirements presented by KDS 41 17 00 and MOE 2021 were satisfied before and after replacement of the reinforcement module, and no fracture of the joint module occurred. As a result of the incremental load test, the physical properties showed a significant difference in the stiffness ratio after yielding under the compressive load of the envelope according to the experimental results. It is judged necessary to further analyze the physical properties according to the experimental results through finite element analysis in the future.

Structural performance of cold-formed steel composite beams

  • Dar, M. Adil;Subramanian, N.;Anbarasu, M.;Dar, A.R.;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.545-554
    • /
    • 2018
  • This study presents a novel method of improving the strength and stiffness of cold-formed steel (CFS) beams. Flexural members are primary members in most of the structures. Hence, there is an urgent need in the CFS industry to look beyond the conventional CFS beam sections and develop novel techniques to address the severe local buckling problems that exist in CFS flexural members. The primary objective of this study was to develop new CFS composite beam sections with improved structural performance and economy. This paper presents an experimental study conducted on different CFS composite beams with simply supported end conditions under four point loading. Material properties and geometric imperfections of the models were measured. The test strengths of the models are compared with the design strengths predicted by using Australian/New Zealand Standard for cold-formed steel structures. Furthermore, to ensure high precision testing, a special testing rig was also developed for testing of long span beams. The description of test models, testing rig features and test results are presented here. For better interpretation of results, a comparison of the test results with a hot rolled section is also presented. The test results have shown that the proposed CFS composite beams are promising both in terms of better structural performance as well as economy.

소형가스루프 시험조건에서 중형 공정열교환기 시제품의 고온구조해석 (High-Temperature Structural Analysis on the Medium-Scale PHE Prototype under the Test Condition of Small-Scale Gas Loop)

  • 송기남;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.33-38
    • /
    • 2012
  • A PHE (Process Heat Exchanger) in a nuclear hydrogen system is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to a chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute has established a small-scale gas loop for the performance test on VHTR components and recently has manufactured a medium-scale PHE prototype made of Hastelloy-X. A performance test on the PHE prototype is scheduled in the gas loop. In this study, high-temperature structural analysis modeling, and macroscopic thermal and structural analysis of the medium-scale PHE prototype by imposing the established displacement boundary constraints in the previous research were carried out under the gas loop test condition. The results obtained in this study will be compared with performance test results.

원자력 전기기기 부품의 내진성능 확인을 위한 진동대 실험 (Shaking Table Test to Verify the Seismic Performance of Nuclear Electric Components)

  • 장성진;전법규;박동욱;김성완
    • 한국지진공학회논문집
    • /
    • 제28권3호
    • /
    • pp.141-147
    • /
    • 2024
  • Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.

전산구조해석을 위한 고성능 직접적 연립방정식 해법의 개발 및 비교 연구 (Development and comparative study of high-performance direct solvers for computational structural mechanics)

  • 우성운;김정호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.387-394
    • /
    • 2004
  • In the structural analysis procedure using finite element technique, the performance of a linear equation solver is critical because the linear equation solving part spends most of the computing time for finite element analysis codes. However, most of researchers are still using inefficient profile-based direct solvers such as the band solver or the skyline solver. In this research, we introduce the multifrontal solution method as an efficient direct solution method for structural analysis, and show the efficiency and performance of the multifrontal solution method by comparing the performance of our own implementation of the multifrontal method with the band solver or the skyline solver. In addition, we also compare the performance of our solver with other implementations of the multifrontal method such as WSMP and MUMPS as well as commercial structural analysis packages such as ABAQUS and NASTRAN. Through the performance test results, the usefulness and efficiency of our domain-wise multifrontal solver for structural analysis is shown.

  • PDF

구조용 합성섬유의 형상 및 단면적 변호에 따른 부착 및 휨 성능 (Pullout and Flexural Performance of Structural Synthetic Fibers by Geometry and Sectional Area Change)

  • 원종필;백철우;박찬기;한일영;김방래
    • 콘크리트학회논문집
    • /
    • 제15권5호
    • /
    • pp.643-649
    • /
    • 2003
  • 본 연구의 목적은 부착실험 및 휨실험을 실시하여 구조용 합성섬유의 단면적 및 표면형상의 변화에 따른 부착성능과 휨성능을 평가하는 것이다. 6가지 다른 형상의 구조용 합성섬유를 조사하였고 부착 및 휨실험을 수행하였다. 6가지 형상의 구조용 합성섬유를 조사하였고 휨시험과 부착시험을 실시하였다. 실험변수는 3가지 종류의 형상과 2가지 종류의 단면적 변화로 하였다. 실험결과 구조용 합성섬유의 단면적이 동일할 때 주기 및 높이가 증가할수록 부착하중 및 인발 파괴 에너지는 감소하고 휨강도는 증가하였다. 또한 주기 및 높이가 일정할 섬유의 단면적이 증가할수록 인발하중과 인발 파괴 에너지는 증가하였고 휨강도는 감소하였다. 실험결과를 기본으로하여 콘크리트의 구조성능은 섬유의 부착성능 뿐만 아니라 콘크리트에 혼입되어 있는 섬유의 수, 인장하중에 저항할 수 있는 섬유의 재료특성 등에 복합적으로 영향을 받는 다는 것을 알 수 있었다.

Experimental studies into a new type of hybrid outrigger system with metal dampers

  • Wang, A.J.
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.183-194
    • /
    • 2017
  • This paper presents the experimental investigation into a new type of steel-concrete hybrid outrigger system developed for the high-rise building structure. The steel truss is embedded into the reinforced concrete outrigger wall, and both the steel truss and concrete outrigger wall work compositely to enhance the overall structural performance of the tower structures under extreme loads. Meanwhile, metal dampers of low-yield steel material were also adopted as a 'fuse' device between the hybrid outrigger and the column. The damper is engineered to be 'scarified' and yielded first under moderate to severe earthquakes in order to protect the structural integrity of important structural components of the hybrid outrigger system. As such, not brittle failure is likely to happen due to the severe cracking in the concrete outrigger wall. A comprehensive experimental research program was conducted into the structural performance of this new type of hybrid outrigger system. Studies on both the key component and overall system tests were conducted, which reveal the detailed structural response under various levels of applied static and cyclic loads. It was demonstrated that both the steel bracing and concrete outrigger wall are able to work compositely with the low-yield steel damper and exhibits both good load carrying capacities and energy dispersing performance through the test program. It has the potential to be applied and enhance the overall structural performance of the high-rise structures over 300 m under extreme levels of loads.

해수전착 코팅을 이용한 내부식성 철근의 개발 및 적용성에 대한 연구 (2) -해수전착된 구조용 철근의 적용성 평가 (Development and Application of Anti-Corrosive Steel Using Electro-Deposition of Sea Water (2)- Evaluation of Application Rebar with Electro-Deposition Using Sea Water)

  • 권성준;이상민;박상순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권6호
    • /
    • pp.155-162
    • /
    • 2012
  • 해수에 노출된 콘크리트 구조물은 시간의 경과에 따라 철근부식이 야기될 수 있으며, 이는 구조적인 성능저하로 진전된다. 1단계 연구에서 도출된 해수전착시스템의 개발을 통하여 2단계 연구에서는 해수전착 코팅된 철근 및 코팅철근을 사용한 RC 콘크리트 부재의 구조적, 내구적 성능이 평가되었다. 내구적 성능평가에서는 반전위 측정이 수행되었는데, 코팅된 철근은 일반철근의 35%수준의 부식속도를 가지고 있었으므로 높은 내부식성을 확보하고 있었다. 구조실험에서는 직접인장시험, 부착력시험, RC 부재를 이용한 휨 및 전단시험이 수행되었다. 인장강도 시험에서는 3.2%, 부착성능에서는 8.8%의 강도 증가가 코팅된 철근에서 평가되었다. RC보에 대한 실험에서는 최대하중 및 파괴형태는 두가지 경우에서 거의 동일하게 평가되었다. 해수전착된 시편은 철근주위에 콘크리트와 비슷한 화합물(수산화마그네슘, 탄산칼슘)이 형성되므로 부착력 및 강도를 일부 증가시키는 것으로 평가되었다. 해수전착철근은 피로, 내충격성, 장기침지실험 등을 통하여 성능이 입증되면 더욱 활발하게 사용될 것으로 사료된다.

계측모니터링 시스템을 활용한 자정식 현수교의 구조성능 평가 (Evaluation of Structural Performance of Self-anchored Suspension Bridge Using Bridge Health Monitoring System)

  • 김정훈;송재호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권2호통권54호
    • /
    • pp.189-198
    • /
    • 2009
  • 본 연구에서는 시공된 실제 현수교에 구축된 계측 모니터링 시스템의 성능을 확인하고, 이 모니터링 시스템을 사용하여 대상교량의 거동특성에 대한 정량적인 정보를 획득하기 위하여 현장재하시험을 수행하였다. 현장재하시험은 정적재하시험, 동적재하시험 및 충격재하시험으로 구성되었으며, 재하시험을 수행함에 앞서 시험결과를 사전에 예측 및 검증하기 위하여 포괄적인 구조해석을 수행하였다. 재하시험 결과는 구조해석결과와 비교하여 면밀하게 분석하였으며, 비교분석 결과 계측값이 구조해석값보다 약 30~50% 정도 작은 값으로 평가되어 대상교량의 우수한 구조성능을 확인하였다. 또한, 대부분의 계측값이 유효한 범위 내에서 측정되는 것을 확인하여 대상교량에 구축된 계측 모니터링 시스템에 대한 신뢰성과 효율성을 검증하였다.

이륙 중량 25 kg급 멀티콥터용 프로펠러 시험 평가 (Test and Evaluation of the Propeller Developed for a Multi-copter with the Take-off Weight of 25 kg)

  • 강희정;김태주;위성용
    • 항공우주시스템공학회지
    • /
    • 제12권4호
    • /
    • pp.26-34
    • /
    • 2018
  • 이륙 중량 25 kg급 멀티콥터용으로 개발된 프로펠러에 대해 정적 구조 시험 및 성능 시험을 통해 설계 요구도 충족 여부를 판별하기 위한 시험 평가를 수행하였다. 정적 구조 시험에서는 극한 하중 및 요구도 하중 부가 후 시편 파손이 발생하지 않음으로써 프로펠러 구조 강도에 대한 안전 여유 3 이상을 갖는 것으로 나타났다. 성능 시험에서는 설계 요구도의 제자리 비행 추력 및 최대 추력을 발생시키고, 운용 추력 영역에서 제자리 비행 성능 효율은 0.73 이상을 나타내었다. 기준 프로펠러와 비교할 때, 성능 효율 최대값은 3% 이상 증가되고, 소비 전력은 운용 영역에서 4% 이상 저감되는 것으로 나타났다. 구조 강도 요구도 및 성능 요구도를 충족시킴으로써 프로펠러는 성공적으로 개발된 것으로 평가되었다.