• Title/Summary/Keyword: Strong-mixing

Search Result 358, Processing Time 0.025 seconds

On the validation of ATHLET 3-D features for the simulation of multidimensional flows in horizontal geometries under single-phase subcooled conditions

  • Diaz-Pescador, E.;Schafer, F.;Kliem, S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3567-3579
    • /
    • 2022
  • This paper provides an assessment of fluid transport and mixing processes inside the primary circuit of the test facility ROCOM through the numerical simulation of Test 2.1 with the system code ATHLET. The experiment represents an asymmetric injection of cold and non-borated water into the reactor coolant system (RCS) of a pressurized water reactor (PWR) to restore core cooling, an emergency procedure which may subsequently trigger a core re-criticality. The injection takes place at low velocity under single-phase subcooled conditions and presents a major challenge for the simulation in lumped parameter codes, due to multidimensional effects in horizontal piping and vessel arising from density gradients and gravity forces. Aiming at further validating ATHLET 3-D capabilities against horizontal geometries, the experiment conditions are applied to a ROCOM model, which includes a newly developed horizontal pipe object to enhance code prediction inside coolant loops. The obtained results show code strong simulation capabilities to represent multidimensional flows. Enhanced prediction is observed at the vessel inlet compared to traditional 1-D approach, whereas mixing overprediction from the descending denser plume is observed at the upper-half downcomer region, which leads to eventual deviations at the core inlet.

Assessment of turbulent heat flux models for URANS simulations of turbulent buoyant flows in ROCOM tests

  • Zonglan Wei;Bojan Niceno ;Riccardo Puragliesi;Ezequiel Fogliatto
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4359-4372
    • /
    • 2022
  • Turbulent mixing in buoyant flows is an essential mechanism involved in many scenarios related to nuclear safety in nuclear power plants. Comprehensive understanding and accurate predictions of turbulent buoyant flows in the reactor are of crucial importance, due to the function of mitigating the potential detrimental consequences during postulated accidents. The present study uses URANS methodology to investigate the buoyancy-influenced flows in the reactor pressure vessel under the main steam line break accident scenarios. With a particular focus on the influence of turbulent heat flux closure models, various combinations of two turbulence models and three turbulent heat flux models are utilized for the numerical simulations of three ROCOM tests which have different characteristic features in terms of the flow rate and fluid density difference between loops. The simulation results are compared with experimental measurements of the so-called mixing scalar in the downcomer and at the core inlet. The study shows that the anisotropic turbulent heat flux models are able to improve the accuracy of the predictions under conditions of strong buoyancy whilst in the weak buoyancy case, a major role is played by the selected turbulence models with essentially a negligible influence of the turbulent heat flux closure models.

Characteristics of nocturnal maximum ozone and meteorological relevance in Pusan coastal area (부산 연안역의 야간 고농도 오존 발생 특성과 기상학적 관련성)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.287-292
    • /
    • 1999
  • This study was performed to investigate the characteristics of nocturnal maxiumu ozone occurrence and the meteorological relevance using to hourly ozone data and meteorological data for 1995~1996 in Pusan coastal area. Kwangbokdong showed the highest occurrence of nocturnal maximum ozone as 36.9%, and Deokcheondong showed the lowest occurrence(9.2%) for research period in Pusan. The occurrence rates of nocturnal maximum ozone concentration were decreased toward land area. The low maximum temperature, high minimum temperature, low diurnal range, high relative humidity, high wind speed, high could amount, low sunshine and low radiation were closely related to the main meteorological characteristics occuring the nocturnal maximum concnetration of ozone. It was shown that normal daily variation of ozone concentration by strong photochemical reaction at the before day of nocturnal maximum ozone. The concnetration of nocturnal maximum ozone were occured by entrainment of ozone from the upper layer of developed mixing layer. There are no ozone sources near the ground at night, so that the nighttime ozone should be entrained from the upper layer by forced convection.

  • PDF

Trend Analysis for Stratospheric Ozone Concentration in the Middle Latitude Northern Hemisphere Using HALOE Data (HALOE 자료를 이용한 중위도 지역의 오존농도 추이분석)

  • Ka, Soo-Hyun;Kwon, Mi-Ra;Oh, Jung-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.413-422
    • /
    • 2005
  • The ozone concentration measured by HALOE (Ver 19) from Oct. 1991 to Dec. 2003 is used for analyzing the variation of ozone concentration. The HALOE loaded in UARS is observing several gases in the atmosphere, from 10km to 80km. Fourier analysis of these data in the middle latitude northern hemisphere is reported in this paper. To detect any possible long term trends, the fourier transformed time series was back transformed after removing signals with time periods of less than 6 months. Although the results clearly show the strong annual cycle, it is difficult to show any long term trends from the fourier series. We also compared the ozone volume mixing ratio's from HALOE with that from the ground-based radiometry to evaluate the accuracy of microwave observation at Sookmyung Women's University.

An influence of the exchange rate on NOE intensities of a ligand: Application to 37kDa trp-holo-repressor/operator DNA complex

  • Lee, Donghan;Lee, Weontae
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.2 no.1
    • /
    • pp.33-40
    • /
    • 1998
  • The cross peak intensities versus mixing times of 2D NOESY spectrum for a corepressor L-trp were simulated for the case of a ligand exchanging between free (AX) and bound (A'X') forms in protein/DNA complex. The direct NOE (I(AX)) of the free ligand exhibited a small positive intensity indicative of the strong dominant influence of the bound ligand. The exchange-mediated NOE peak (I(AX')) was very sensitive to corepressor exchange. However, both diagonal (I(A'A')) and direct NOE (I(A'X')) intensities of the bound ligand were not affected much at initial stage. Both peaks were severely influenced by exchange at mixing times of greater than 100 ms. In conclusion, since the NOE intensity is a function of exchange rate, the exchange effect should be considered to properly extract accurate distance information for bound ligand in the presence of conformational exchange.

  • PDF

A Comparison of the Effect of Tabs-Direction and Surface Roughness of Nozzle Surface on Supersonic Jet Flowfields (탭의 방향과 노즐내부 표면 거칠기가 초음속제트 유동장에 미치는 영향의 비교에 관한 연구)

  • Jin, Won-Jin;Cho, Chang-Kwun;Lee, Yeol
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.525-530
    • /
    • 2000
  • The effects of vortex generators, in the form of small tabs projecting into the flow at the axisymmetric supersonic nozzle exit and triangular thin tapes attached on the inner surface at the nozzle exit, on the characterixtics of supersonic mixing enhancements are experimentally investigated. Delta-shaped tabs as small as 1% of the nozzle exit area produce strong counter-rotating vortices, and is found to produce significant effects on the jet flowfield downstream of the nozzle. The effects is larger on the under-expanded cases than over- and perfect-expanded cases. Nozzle inner surface roughness also can do a role of centerline pressure decay for highly under-expanded jet cases. The effects of the angle of tabs with respect to flow direction are also investigated.

  • PDF

Comparative measurements of Criteria Pollutants Using DOAS and Conventional In-situ Monitoring Technique at Sung Nam city of Korea

  • Kim, Ki-Hyun;Jin, Byong-Bok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E4
    • /
    • pp.169-181
    • /
    • 2001
  • To test the compatibility of differential optical absorption spectroscopy (DOAS) and conventional in-situ monitoring technique we conducted a comparative analysis of the two systems using hourly measurement data sets of three criteria pollutants including No$_{2}$O$_{3}$, and SO$_{2}$ collected in months between April and June of 2001 at Sung Man city, Kyung Gi Province, Korea. The results of our comparative analysis were useful to evaluate the various aspects of DOAS performance, of particular the level of agreement with the counterpart method through computation of percent differences and correlation analysis. Interpretation of the mixing ratio data for those chemical species was however confined in terms of explaining the differences affected by the changes in environmental conditions because measurements of important meteorological parameters were limited during most of the study period. Nevertheless, the overall results of this study strongly demonstrated that the mixing ratio of major pollutants measured by the two different systems maintain strong compatibility from various respects.

  • PDF

Enhanced Corrosion Resistance of WC-Co with an Ion Beam Mixed Silicon Carbide Coating

  • Yeo, Sun-Mok;Park, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.193-193
    • /
    • 2011
  • Strong adhesion of a silicon carbide (SiC) coating to a WC-Co substrate was achieved through an ion beam mixing technique and the corrosion resistance of the SiC coated WC-Co was investigated by means of a potentiodynamic electrochemical test. In a 1 M NaOH solution, the corrosion current density of SiC-coated WC-Co after heat treatment at 500$^{\circ}C$ was about 50 times lower than that for the as-received WC-Co. In addition, the corrosion resistance systematically increases with increasing the SiC coating thickness. On the other hand, for a 0.5 M H2SO4 solution, the corrosion current density for SiC-coated WC-Co was about 3 times lower than that for the as-received WC-Co. We discuss the physical reasons for the changes in the corrosion current density with the different electrolytes.

  • PDF

Buoyancy Effects on Turbulent Mixing in the LMFBR Outlet Plenum (LMFBR 출구 공간에 있어서의 난류 혼합에 미치는 부력 효과)

  • Soon Heung Chang
    • Nuclear Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.50-56
    • /
    • 1983
  • The effect of flow stratification is of particular concern during transient after scram in the outlet plenum of LMFBR. In this case, buoyancy effects on turbulent mixing are of importance to designers. An investigation has been made to identify the appropriate change in the available turbulence models which are necessary to include the effects of buoyancy on turbulence transport equations. The developed physical model of the buoyant turbulent flow are solved through SMAC method. Testing of the developed numerical model was undertaken and compared with experimental results. The results show that the buoyant turbulent effects account for a significant increase in the stability of the stratification, with a strong suppression of turbulence in the outlet plenum.

  • PDF

Analysis of Combustion Air Flow in Incinerator (소각로의 연소 공기 유동 해석)

  • Lee, Dong-Hyuk
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.26-32
    • /
    • 2022
  • It is known that the fluidized bed incinerator, which is the subject of analysis, shows excellent performance in heat and mass transfer due to excellent mixing and contact performance between fluidized sand and fuel, and also shows relatively good combustion characteristics thanks to good mixing and long residence time for low-grade fuels. have. In this study, air flow analysis is performed to understand the characteristics of co-firing of sludge, waste oil and solid waste in the fluidized bed incinerator, flow characteristics of flue gas, and discharge characteristics of pollutants.The fluidized bed incinerator subject to analysis is a facility that incinerates factory waste and general household waste together with sludge, with a processing capacity of 32 tons/day. to be. In addition, the operation method was designed for continuous operation for 24 hours. As a result, it can be seen that the lower combustion air and the introduced secondary air are changed to a strong turbulence and swirl flow form and exit through the outlet while rotating inside the freeboard layer. The homogeneous one-way flow form before reaching the secondary air nozzle has very high diffusivity with the high-speed jet flow of the nozzle.