• Title/Summary/Keyword: Stripping voltammetry

Search Result 129, Processing Time 0.021 seconds

Trace Mercury Determination by Differential Pulse Anodic Stripping Voltammetry Using Polythiophene-Quinoline/Glassy Carbon Modified Electrode

  • Yoo, Kwang-Sik;Woo, Sang-Beom;Jyoung, Jy-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.27-31
    • /
    • 2003
  • A Polythiophene-quinoline/glassy carbon (PTQ/GC) modified electrode was developed for the determination of trace mercury in industrial waste water, natural water, soil, and other media. The electrode was prepared by the cyclic voltammetric polymerization of thiophene and quinoline on glassy carbon (GC) electrode by the potential application from -0.6 V to +2.0 V (50 mV/sec) in a solution of 0.1 M thiophene, quinoline and tetrabutyl ammonium perchlorate (TBAP) in acetonitrile. Optimum thickness of the polymer membrane on the GC electrode was obtained with 20 repeated potential cyclings. The redox behavior of Cu(Ⅱ) and Hg(Ⅱ) were almost identical on this electrode. The addition of 4-(2-pyridylazo)resorcinol (PAR) to the solution containing Cu(Ⅱ) and Hg(Ⅱ) allowed the separation of the components due to the formation of the Cu(Ⅱ)-PAR complex reduced at -0.8V, which was different from the Hg(Ⅱ) reduced at -0.5 V on a saturated calomel electrode (SCE). The calibration graph of Hg(Ⅱ) shows good linear relationship with the correlation factor of 0.9995 and the concentration gradient of 0.33 ㎂/㎠/ppb down to 0.4 ppb Hg. The method developed was successfully applied to the determination of mercury in samples such as river, waste water, and sea water.

Determination of Hg (II) Ion at a Chemically Modified Carbon Paste Electrode Containing L-Sparteine (L-Sparteine 수식전극을 사용한 Hg (II) 이온의 정량)

  • Euh Duck Jeong;Mi-Sook Won;Yoon-Bo Shim
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.545-552
    • /
    • 1991
  • A mercury ion-sensitive carbon-paste electrode (CPE) was constructed with l-sparteine. Mercury (II) ion was chemically deposited by the complexation with l-sparteine onto the CPE. The surface of CPEs was characterized by cyclic voltammetry and anodic stripping voltammetry in an acetate buffer solution, separately. Exposure of CPEs to acid solution could regenerate surface and reuse it for deposition. In 5 deposition/measurement/regeneration cycle, the response was reproducible and in licnear up to $2.0\;{\times}\;10^{-6}$ M with linear sweep voltammetry. In case of using the differential pulse technique, we have obtained the linear response up to $7.0 {\times}10^{-7}$ M with relative standard deviation of ${\pm}5.1$%. The detection limit was $5.0{\times}10^{-7}$ M for 20 minutes of the deposition. We have investigated the interference effect of various metal ions, which are expected to form the complex with ligand. Silver (I) ion of these has interfered with the analysis of Hg (II) ions. However, pretreatment of the silver (I) ion with potassium chloride led to no interference on the analysis of mercury ions in aqueous solution.

  • PDF

Electrochemical Determination of Ag(I) Ion at Chemically Modified Carbon-Paste Electrode Containing 1,5,9,13-Tetrathiacyclohexadecane (1,5,9,13-Tetrathiacyclohexadecane 수식전극을 사용한 Ag(I)의 전기화학적 정량)

  • Ha, Kwang Soo;Jang, Mi-Kyeong;Seo, Moo Lyong
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.187-195
    • /
    • 1997
  • Chemically modified electrodes(CMEs) for Ag(I) were constructed by incoporating 1,5,9,13-tetrathiacyclohexadecane([16]-ane-$S_4$) with a conventional carbon-paste mixture composed of graphite powder and nujol oil. Ag(I) ion was chemically deposited onto the surface of the modified electrode with [16]-ane-$S_4$ by immersion of the electrode in the acetate buffer solution(pH=4.5) containing $5.0{\times}10^{-4}M$ Ag(I) ion. And then the electrode deposited with Ag(I) was reduced at -0.3V vs. S.C.E. Well-defined stripping voltammetric peaks could be obtained by scanning the potential to the positive direction. The CME surface was regenerated with exposure to 0.1M $HNO_3$ solution and was reused for the determination of Ag(I) ion. When deposition/measurement/regeneration cycles were 10 times, the response could be reproduced with relative standard deviation of 6.08%. In case of differential pulse stripping voltammetry, the calibration curve for Ag(I) was linear over the range of $5.0{\times}10^{-7}{\sim}1.5{\times}10^{-6}M$. And the detection limit was $2.0{\times}10^{-7}M$. Various ions such as Cd(II), Ni(II), Pb(II), Zn(II), Mn(II), Mg(II), EDTA, and oxalate(II) did not influence the determination of Ag(I) ion, except Cu(II) ion.

  • PDF

Quantitative Determination of $UO2^{2+}$ with Modified $[Ru(v-bpy)_3]^{2+}$ Polymer Film Electrode (수식된 $[Ru(v-bpy)_3]^{2+}$ 고분자 피막전극을 이용한 U(VI)의 정량)

  • Cha, Seong-Keuck
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.1
    • /
    • pp.17-23
    • /
    • 2000
  • Electrodes of the polycationic film with electropolymerized $[Ru(v-bpy)_3]^{2+}$ having about 1:1 ratio of $PF6^-/ClO_4^-$as the doped counter ions, were modified with xylenol orange and diethylditbiocarbamate by ion exchange which had stability constant as 38.6 and 17.5 respectively. These electrodes were employed in the quantitative multiple determination of U(W) in solution. The working electrode of electrochemical cell for the analytical signal was Pt/p-$[Ru(v-bpy)_3]^{2+}$, ligand, U(VI) with Ag/AgCl reference elecrode. In the stripping voltammetry. electrode process was electron transfer controlled one and calibration curves at the ranges of $1.0{\times}10^{-3}{\sim}1.0{\times}10^{-7}$ M had excellent relationship as 0.99 and relative standard deviation as 5${\sim}$8%.

  • PDF

Determination of Iron in Seawater by Adsorptive Stripping Voltammetry (흡착 벗김 전압전류법에 의한 해수중 미량 철의 정량)

  • Czae, Myung-Zoon;Kim, Kyung;Kwon, Young-Soon
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.3
    • /
    • pp.186-190
    • /
    • 1995
  • A simple procedure, readily available at low cost with a sensitivity sufficient to determine trace levels of iron in seawater is proposed, which utilizes adsorptive accumulation of the iron/catechol complex on the mercury drop electrode in a borate medium of pH 8.0. Optimal conditions include a solution concentration of 2 mM catechol, 2.5 mM borate and a pH of 8.0, an accumulation potential of - 0.25 V is applied for 1∼3 min, and the potential scan is in the differential pulse mode. The limit of detection is 1.5 nM Fe using a preconcentration time of 3 min. The interference from copper can be eliminated and baseline slope is greatly improved, because its peak is well separated from that of iron in the proposed medium.

  • PDF

Low cost, highly sensitive and selective electrochemical detection of arsenic (III) using silane grafted based nanocomposite

  • Lalmalsawmi, Jongte;Zirlianngura, Zirlianngura;Tiwari, Diwakar;Lee, Seung-Mok
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.579-587
    • /
    • 2020
  • Novel silane grafted bentonite was obtained using the natural bentonite as precursor material. The material which is termed as nanocomposite was characterized by the Fourier Transform Infra-red (FT-IR) and X-ray diffraction (XRD) methods. The surface imaging and elemental mapping was performed using Scanning Electron Microscopic (SEM/EDX) technique. The electroanalytical studies were performed using the nanocomposite electrode. The electroactive surface area of nanocomposite electrode was significantly increased than the pristine bentonite or bare carbon paste based working electrode. The impedance spectroscopic studies were conducted to simulate the equivalent circuit and Nyquist plots were drawn for the carbon paste electrode and nanocomposite electrodes. A single step oxidation/reduction process occurred for As(III) having ΔE value 0.36 V at pH 2.0. The anodic stripping voltammetry was performed for concentration dependence studies of As(III) (0.5 to 20.0 ㎍/L) and reasonably a good linear relationship was obtained. The detection limit of the As(III) detection was calculated as 0.00360±0.00002 ㎍/L having with observed relative standard deviations (RSD) less than 4%. The presence of several cations and anions has not affected the detection of As(III) however, the presence of Cu(II) and Mn(II) affected the detection of As(III). The selectivity of As(III) was achieved using the Tlawng river water sample spiked with As(III).

Effect of Tungsten on PtRuW/C Catalysts for Promoting Methanol Electro-oxidation (메탄올 전기산화반응 증진을 위한 PtRuW/C 촉매에서 텅스텐의 효과에 관한 연구)

  • Noh, Chang Soo;Sohn, Jung Min;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.561-566
    • /
    • 2012
  • PtRuW/C catalysts were prepared with the different molar ratios of Pt : Ru : W and their compositions were analyzed by energy dispersive X-ray (EDX). The uniform distribution of particles was observed using transmission electron microscopy (TEM). An average crystalline size of 3.5~5.5 nm was calculated based on x-ray diffraction (XRD) data. The electrochemical properties such as electrochemically active surface areas, current densities, specific activities and poisoning rates, were analyzed via CO stripping, linear sweep voltammetry and chronoamperometry. From the analysis, we observed that ternary alloy catalysts, except $PtRu_2W_2/C$, have higher current densities, specific activities and stabilities than those of commercial binary catalysts. Among all in-house catalysts, Pt5Ru4W/C showed the highest specific activity of $121.05mA{\cdot}m^{-2}$ and the lowest poisoning rate of $0.01%{\cdot}s^{-1}$.

Electrochemical Evaluation of Cadmium and Lead by Thiolated Carbon Nanotube Electrodes (티올화된 탄소나노튜브 전극을 이용한 카드뮴과 납의 전기화학적 분석)

  • Yang, Jongwon;Kim, Lae-Hyun;Kwon, Yongchai
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.551-557
    • /
    • 2013
  • In the present study, pristine carbon nanotube (p-CNT) and thiolated carbon naotube (t-CNT) electrodes were investigated to improve their detectabilities for cadmium (Cd) and lead (Pb). In addition, we evaluate which reaction mechanism is used when the electrolyte contains both Cd and Pb metals. Square wave stripping was employed for analyzing the sensitivity for the metals. A frequency of 30 Hz, a deposition potential of -1.2 V vs. Ag/AgCl and a deposition time of 300 s were used as optimal SWSV parameters. t-CNT electrodes show the better sensitivity for both Cd and Pb metals than that of p-CNT electrodes. In case of Cd, sensitivities of p-CNT and t-CNT electrodes were $3.1{\mu}A/{\mu}M$ and $4.6{\mu}A/{\mu}M$, respectively, while the sensitivities for Pb were $6.5{\mu}A/{\mu}M$ (p-CNT) and $9.9{\mu}A/{\mu}M$ (t-CNT), respectively. The better sensitivity of p-CNT electrodes is due to the enhancement in the reaction rate of metal ions that are facilitated by thiol groups attached on the surface of CNT. When sensitivity was measured for the detection of Cd and Pb metals present simultaneously in the electrolyte, Pb indicates better sensitivity than Cd irrespective of electrode types. It is ascribed to the low standard electrode potential of Pb, which then promotes the possibility of oxidation reaction of the Pb metal ions. In turn, the Pb metal ions are deposited on the electrode surface faster than that of Cd metal ions and cover the electrode surface during deposition step, and thus Pb metals that cover the large portion of the surface are more easily stripped than that of Cd metals during stripping step.

Electrochemical Analysis and Applications of Tetracycline Transfer Reaction Process at Liquid/liquid Interfaces (액체/액체 계면에서 테트라사이클린 전이반응의 전기화학적 분석 및 응용)

  • Liu, XiaoYun;Han, Hye Youn;Goh, Eunseo;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.506-512
    • /
    • 2017
  • The transfer reaction characteristics of tetracycline (TC) across a polarized water/1,2-dichloroethane (1,2-DCE) interface was studied via controlling both pH and ionic strength of the aqueous phase in conjunction with cyclic and differential pulse voltammetries. Formal transfer potential values of differently charged TC ionic species at the water/1,2-DCE interface were measured as a function of pH values of the aqueous solution, which led to establishing an ionic partition diagram for TC. As a result, we could identify which TC ionic species are more dominant in the aqueous or organic phase. Thermodynamic properties including the formal transfer potential, partition coefficient and Gibbs transfer energy of TC ionic species at the water/1,2-DCE interface were also estimated. In order to construct an electrochemical sensor for TC, a single microhole supported water/polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel interface was fabricated. A well-defined voltammetric response associated with the TC ion transfer process was achieved at pH 4.0 similar to that of using the water/1,2-DCE interface. Also the measured current increased proportionally with respect to the TC concentration. A $5{\mu}M$ of TC in pH 4.0 buffer solution with a dynamic range from $5{\mu}M$ to $30{\mu}M$ TC concentration could be analyzed when using differential pulse stripping voltammetry.