• 제목/요약/키워드: Stripping analysis

검색결과 122건 처리시간 0.025초

Assay of In Vivo Chromium with a Hollow-fiber Dialysis Sensor

  • Ly, Suw-Young;Yoo, Hai-Soo;Jung, Min-Ki;Ko, Kwang-Hee;Kim, Byung-Jin;Lee, Ki-Chul;Choi, Byung-Min
    • Toxicological Research
    • /
    • 제26권3호
    • /
    • pp.233-236
    • /
    • 2010
  • The analytical in vivo chromium ion was searched for using a voltammetric hollow-fiber dialysis sensor via square wave stripping voltammetry (SW), cyclic voltammetry (CV), and chronoamperometry. Under optimum parameters, the analytical results indicated linear working ranges of 50~400 mg/l CV and $10{\sim}80\;{\mu}g/l$ SW within a 30-sec accumulation time. The analytical detection limit (S/N) was $6.0\;{\mu}g/l$. The developed method can be applied to in vivo tissues and in ex vivo toxicity assay, as well as to other materials that require chromium analysis.

Electrochemical Diagnosis of Magnesium Ion in Fish Liver and Mice Droppings

  • Lee, Chang-Hyun;Ly, Suw Young
    • 한국응용과학기술학회지
    • /
    • 제31권4호
    • /
    • pp.663-668
    • /
    • 2014
  • An in-vivo diagnosis of trace Mg(II) ion was performed using a low-cost and environment-friendly voltammetric method, using a graphite counter and reference electrodes and a fluorine-immobilized graphite working electrode, and clean deep seawater was used as an electrolyte solution. Under optimum conditions, the analytical working ranges attained microgram ranges, and a detection limit of $80.6ugL^{-1}$ was obtained using stripping voltammety with 60 sec accumulation time. Ex-vivo application was performed on fish liver and mice droppings. The developed techniques can be applicable to tumor cell analysis.

Spin Etcher의 진동 분석 (Vibration Analysis of Spin Etcher)

  • 임경화;이은경;조중근
    • 반도체디스플레이기술학회지
    • /
    • 제2권1호
    • /
    • pp.15-19
    • /
    • 2003
  • Spin etcher can process frontside and backside on the wafer, which is used for etching, stripping, cleaning and wafer reclamation. A new generation of spin etchers has been designed to meet 300mm wafer processing. The larger header and higher spin speed make vibration problem a severe problem in developing equipments. This study shows schematic process of solving practical vibration problems, where it is required to analyze the principal ca uses of vibration problem and find out the method of vibration reduction in spin etcher. The vibration under normal operation is measured in time domain and is analyzed in frequency domain. And modal parameters are obtained through modal test. Using the modal parameters from experiments, the model of finite element method is formulated. From diagnosis using many measurements and analyses, it can be shown that main cause of vibration is unbalance of head.

  • PDF

A Study on the Desorption Behaviors of Some Heavy Metals on Duolite GT-73 Chelating Resin

  • Kim, Sook-Young;Lee, Jae-Suk;Kim, Young-Man;Choi, Beom-Suk
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.530-534
    • /
    • 2001
  • Effect of stripping solutions on the Duolite GT-73 chelating resin for ten elements, Ag(I), Al(III), Ca(II), Cd(II), Cu(II), Fe(II), Hg(II), Mn(II), Pb(II), and Zn(II), was investigated. Relation between affinities of the metal ions and solubility products of metal sulfides was studied. The smaller the solubility product of metal sulfideis, the larger the affinitie with the ionsis. The ions which have the solubility products larger than $10^{-23}$ could be effectively desorbed with nitric acid. Complexation with chloride ion enhanced the desorption efficiencies of the ions having moderately strong affinity with the resin. The ions which have very strong affinity by the chelating resin can be desorbed by complextion with thiourea and hydrochloric acid.

  • PDF

황산바나듐 모의용액으로부터 Alamine336에 의한 바나듐 용매추출의 최적조건 연구 (The Optimum Condition Analysis of Vanadium Solvent Extraction by Alamine336 from the Synthetic Vanadium Sulfate Solution.)

  • 안종관;안재우
    • 대한금속재료학회지
    • /
    • 제46권12호
    • /
    • pp.823-829
    • /
    • 2008
  • The solvent extraction process for the recovery of vanadium from leaching solution of SCR(selective catalytic reduction) spent catalyst was investigated by using Alamine336 as an extractant. The effects of experimental conditions, such as initial pH and concentration of sulfate ion, and ammonia concentration of stripping solution were studied. The extraction percentage of vanadium were increased with the increase of initial pH of leaching solution and decreased with the increase of sulfate ion. More than 99% of vanadium in leaching solution were extracted and stripped at the A/O ratio of 1.0 in 2 stages. On the basis of these results, an optimum solvent extraction process which vanadium was effectively recovered from SCR spent catalyst was proposed.

Diagnostic ex vivo assay of glucose in live cell using voltammetry

  • Ly, Suw Young;Leea, Chang Hyun
    • 한국응용과학기술학회지
    • /
    • 제35권4호
    • /
    • pp.1379-1385
    • /
    • 2018
  • The hand held voltammetry systems searched diabetic assay using glucose sensor of fluorine nafion doped carbon nanotube electrode (FCNE). An inexpensive graphite carbon pencil was used as an Ag/AgCl reference and Pt counter electrode. Upon combining and using three electrode systems, optimum square wave (SW) stripping results were attained to 1.0-9.0 ug/L with 8 points. Statistic RSD precision was of 6.02 % with n=15 in 0.1 mg/L glucose. After a total of 200 second accumulation times, analytical detection limit of 0.8 ug/L was obtained. This developed technique was applied to urine samples from diabetic patients urine for fluid analysis, it was determined that the sensor can be used with a diagnostics in the ex vivo of live cells and non treated biological fluid.

Comparison of CO on Carbon-supported Pt Catalysts Prepared by CO Gas Bubbling and Methanol Dehydrogenation

  • Han, Kee-Sung;Hwang, Ki-Ju;Han, Oc-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2442-2444
    • /
    • 2007
  • CO adsorbates on the surface of Pt supported on carbon catalysts (Pt/C) were investigated by CO stripping voltammetry. Three types of CO adsorbed samples were prepared: by methanol dehydrogenation only (COm), by CO gas bubbling only (COg), and by methanol dehydrogenation followed by CO gas bubbling (COm+g). Our coverage data show that CO gas can be adsorbed on Pt/C catalyst already saturated with CO adsorbates by methanol dehydrogenation. The COm+g sample showed the properties of both COm as well as COg samples in terms of the potential although the CO adsorbed by dehydrogenation was completely exchanged with CO in the electrolyte solution. Therefore, the oxidation pathways of CO on Pt/C were observed to depend on the initial adsorption conditions of CO more strongly than on the CO coverage. Our results imply that an initial CO poisoning condition in fuel cell operation is an important factor to determine the difficulty in removing the adsorbed CO and confirm that the properties of the adsorbed CO do not change even with chemical replacement with CO in different conditions. In addition, our results indicate a low CO surface mobility on the Pt in an electrolyte solution.

국내 과학전문채널 활성화를 위한 콘텐츠 개발 및 홍보전략 연구 (Investigation on the Content Development and Promotional Strategy to Vitalize the Korean Science Channel)

  • 송해룡;김원제;조항민
    • 한국콘텐츠학회논문지
    • /
    • 제12권5호
    • /
    • pp.103-112
    • /
    • 2012
  • 본 연구는 과학대중화에 있어 중요한 역할을 수행하고 있는 국내 과학전문채널인 'YTN 사이언스'가 시청률, 콘텐츠, 제작비의 부족을 드러내고 있다는 문제인식 하에, 우선 현행 국내 과학전문채널의 프로그램 편성과 운영현황, 홍보 전략을 탐색적으로 확인하였다. 다음으로 미국(디스커버리 채널, 내셔널지오그래픽 채널), 영국(BBC Knowledge), 일본(사이언스채널), 중국(CCTV 10) 등 해외 각국의 과학방송채널 특히, 중요 프로그램들을 분석하여 향후 국내 과학전문채널에 활용 및 접목시킬 수 있는 가능성을 모색하였다. 이러한 현실진단과 해외사례분석을 통해 다양한 시사점을 확인하였으며, 이를 통해 제시될 수 있는 콘텐츠 개발 및 홍보전략은 다음과 같다. 우선 콘텐츠가치 제고를 위한 편성전략의 수정이 필요한 바, 타깃 시청집단과 시청자 라이프스타일을 고려한 편성 재조정, 줄띠편성(Stripping)을 통한 시청습관화 전략, 프라임타임(prime time)대의 전략 프로그램 배치가 필요할 것이다. 다음으로 콘텐츠제작 및 활용전략 측면에서는 콘텐츠 제작의 이중적 전략(지식전달, 흥미전달의 두 분야로의 구분), 프로그램의 대표 캐릭터의 기획과 활용, 한국적 과학기술소재의 선택, SNS와의 전략적 연계, 소재의 다변화와 심층화, OSMU 활성화 전략이 요구될 것이다. 마지막으로 홍보전략 차원에서는 과학관련 행사 개최와 중계방송을 통한 채널 인지도 제고, 잡지 및 단행본 발간 등 인쇄매체로의 확장을 통한 홍보전략 수행, 온라인/모바일 홍보 전략의 강화 등을 제시할 수 있겠다.

콘크리트 교면 아스팔트포장의 구조적 거동 및 파손 (Structural Behavior and Distress of Asphalt Pavement on Concrete Bridge Decks)

  • 박성완;이현종;이완훈
    • 한국도로학회논문집
    • /
    • 제6권1호
    • /
    • pp.13-23
    • /
    • 2004
  • 본 논문은 국내의 콘크리트 교면포장에 주로 발생하는 아스팔트 포장의 파손유형들에 대한 현황 분석과 교량 상판과 포장의 상호작용 해석을 실시하여 주된 파손유형을 제시하고자 한다 연구의 범위는 PSCI형교, 철근콘크리트 슬라브교와 라멘교를 각각 대상으로 하였다. 조사결과 콘크리트 교면 아스팔트 포장의 주요 파손들은 소성변형, 포트홀 그리고 피로균열 순으로 확인되었다. 또한 교면 아스팔트 포장에 발생되는 피로균열의 경우 주된 파손인자가 교통하중의 반복보다는 포장의 노후화나 재료의 박리와 같은 재료 문제로 추정되며 실제조사에서도 콘크리트 교량의 경우 미세한 파손의 빈도가 높고 박리가 있는 지점에서 균열이 상대적으로 많이 발생되었다.

  • PDF

시차펄스 양극벗김 전압-전류법에 의한 희토류 원소의 분석에 관한 연구 (A study on the analysis of rare earth elements by differential pulse anode stripping voltammetry)

  • 김재균;차기원
    • 분석과학
    • /
    • 제18권5호
    • /
    • pp.369-375
    • /
    • 2005
  • 몇 가지 희토류 원소 이온들과 이들의 카테콜 착물 들의 시차펄스 양극벗김 voltammogram들을 0.1 M LiCl 와 pH 5.3 용액에서 연구하였다. 회토류 원소 이온의 산화 봉우리는 원소에 따라 하나 또는 두 개의 봉우리가 나타났고, 산화봉우리 전류는 농도의 증가에 따라 직선적으로 증가하였다. $Eu^{3+}$$Pr^{3+}$은 각각 -0.2 V에서 산화 봉우리가 나타났고, $Tm^{3+}$, $Tb^{3+}$, $Yb^{3+}$$Sm^{3+}$은 -0.5 V와 -0.2 V에서 각각 두개의 산화 봉우리가 생성되었다. 이 산화 전류를 이용한 검정곡선의 직선범위는 대략 1.0 ppm~10 ppm정도였다. 희토류 이온-카테콜 착물의 시차 펄스 양극 벗김 oltammogram에서는 $Tb^{3+}$-catechol 과 $Eu^{3+}$-catechol 착물 에서는 -0.95 V와 -0.65 V에서 각각 하나의 산화봉우리가 나타났고, $Sm^{3+}$-catechol, $Pr^{3+}$-catechol, $Tm^{3+}$-catechol 및 $Yb^{3+}$-catechol의 착물에서는 두 개의 산화 봉우리가 나타났다. 이를 이용한 검정곡선의 농도범위는 대략 0.1 ppm-1.0 ppm 정도였다. 따라서 희토류 원소의 voltammogram의 산화전류 보다 희토류 이온-카테콜 착물의 산화 전류의 감도가 10배 정도 증가함을 알았다.