• Title/Summary/Keyword: Stripping Method

Search Result 163, Processing Time 0.025 seconds

Analysis of Cu in Mezcal Commercial Samples using Square Wave Anodic Stripping Voltammetry

  • Salinas, Gerardo;Ibanez, Jorge G.;Vasquez-Medrano, Ruben;Frontana-Uribe, Bernardo A.
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.276-281
    • /
    • 2018
  • High concentration of copper in mezcal, a representative Mexican spirituous alcoholic beverage, is a serious problem due to the damage that it may cause to human health. A cyclic voltammetry and square wave anodic stripping voltammetry study of copper (II) in three commercial mezcal samples based on glassy carbon electrode response was undertaken. The analysis was developed using a simulated matrix solution ($EtOH/H_2O$ (1:1), 0.1 M $LiClO_4$ and AcOH/AcONa 0.05 M/0.008 M), with Cu (II) concentrations in the range 0 - 1 ppm. Direct electrochemical analysis of mezcal samples was complicated by the presence of different organic compounds in the matrix. The analytical signal of Cu (II) in the spirituous was notably improved and the interferences caused by organic compounds were minimized, by diluting the mezcal samples 10% with $EtOH/H_2O$ (1:1) solution. An efficient quantification of Cu (II) was obtained from the calibration curve by the SWASV and using the internal standard method (Cd (II)) in commercial samples (1.2-6.7 ppm); the results were correlated satisfactorily with the values obtained by AAS.

Stripping of Ion-Implanted Photoresist Using Cosolvent-Modified Supercritical Carbon Dioxide (공용매로 변형된 초임계 이산화탄소를 이용한 이온 주입 포토레지스트 세정)

  • Jung, In-Il;Kim, Ju-Won;Lee, Sang-Yun;Kim, Woo-Sik;Ryu, Jong-Hoon;Lim, Gio-Bin
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.27-32
    • /
    • 2005
  • We propose an effective and environmentally friendly dry stripping method using a supercritical carbon dioxide ($SCCO_2$) system modified by a single and multiple cosolvents to remove ion-implanted photoresist and residue from a wafer surface at three different temperatures (97, 148, $200^{\circ}C$) and pressures (200, 300, 400 bar). After high dose of ion implantation the photoresist was not easily removed by using pure $SCCO_2$, but swollen. The $SCCO_2$ system modified by single cosolvents and multiple cosolvents mixed with aprotic solvents could not effectively remove the heavy organics, but swell them. However, the $SCCO_2$ system modified with multiple cosolvent (5%, v/v) composed of DMSO and DIW showed high removal efficiency for ion-implanted photoresists at $97^{\circ}C$ and 200 bar for 30 min (about 80%). In this study it has been shown that the dry stripping method using $SCCO_2$ system modified with multiple cosolvents could replace either plasma ashing or acid and solvent wet bench method and dramatically reduce accompanied chemical usage and disposal.

$H^-$ Stripping Simulation with a Magnet and $H^{\circ}$ Beam Extractor Design

  • Ahn, Hyo-Eun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.951-956
    • /
    • 1998
  • The beam extraction system for the KOMAC[1] (Korea Multi-purpose Accelerator Complex) project is to be designed to partially extract H ̄ beam at both 100 and 260 MeV This paper describes a simulation study of charge changing extraction with a stripper magnet and a possible design of a H$^{0}$ extractor by utilizing the simulation study The method consists of converting the negative hydrogen (H ̄) ion beam from the linac to a chosen intensity (0-100%) of neutral hydrogen (H$^{0}$ ) beam having an acceptable omittance and drifting it directly onto a stripper foil followed by a downstream beamline.

  • PDF

Real-Time Voltammetric Assay of Lead Ion in Biological Cell Systems

  • Ly, Suw-Young
    • Toxicological Research
    • /
    • v.25 no.4
    • /
    • pp.231-235
    • /
    • 2009
  • Trace lead detection for cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry was performed using mercury immobilized onto a carbon nanotube electrode (HNPE). Using the characteristics of mercury and the catalytic carbon nanotube structure, a modified technique, the $0.45{\mu}g/l$ detection limit of lead ion was attained. The developed method can be applied to pond water, fish tissue, plant tissue, and in vivo direct assay.

A Study on Skin Permeability and Skin Whitening Effect of High Pressure Emulsification Processed Cosmetic (고압유화 공정이 적용된 화장품의 피부흡수 및 피부 미백효과 연구)

  • Jang, Sue Im;Lee, So Mi;Paik, Byung Ryol;Han, Jiyeon;Kim, Eun Joo;Lee, Hae Kwang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.3
    • /
    • pp.189-194
    • /
    • 2017
  • Skin has a strong barrier function to protect the body from external harmful factors. This strong barrier function of the skin makes for any effective substance difficult to permeate through the skin. The purpose of this study was to evaluate skin permeability of the reduced particle size by non-invasive method. The particles were prepared by high-pressure emulsification. The niacinamide prepared in a high-pressure emulsification was absorbed 1.56 times higher than the control sample. In addition, it was found from the sixth layer of keratin that was removed by tape-stripping method. This was significantly deeper penetration. The whitening efficacy of the sample containing niacinamide was evaluated before and after 6 weeks of use. The skin color was significantly improved in both pigmented area and non-pigmented area. Through this study, it was possible to visually and quantitatively confirm the permeability confirm the permeability of the reduced particle sample into skin.

A Study on Detection Characteristics of Cadmium and Lead for Bi Nanopowder-Labeled Electrode (비스무스 나노분말 표지 전극의 카드뮴/납 검출특성에 관한 연구)

  • Lee, Gyeoung-Ja;Kim, Hyoun-Jin;Lee, Hi-Min;Lee, Sang-Hoon;Lee, Min-Ku;Lee, Chang-Kyu
    • Journal of Powder Materials
    • /
    • v.15 no.5
    • /
    • pp.393-398
    • /
    • 2008
  • Trace analysis of Cd and Pb at surface modified thick film graphite electrode with Bi nanopowder has been carried out using square-wave anodic stripping voltammetry (SWASV) technique. Bi nanopowder synthesized by gas condensation (GC) method showed the size of $50{\sim}100$ nm with BET surface area, $A_{BET}=6.8m^{2}g^{-l}$. For a strong adhesion of the Bi nanopowder onto the screen printed carbon paste electrode, nafion solution was added into Bi-containing suspension. From the SWASV, it was found that the Bi nanopowder electrode exhibited a well-defined responses relating to the oxidations of Cd and Pb. The current peak intensity increased with increasing concentration of Cd and Pb. From the linear relationship between Cd/Pb concentrations and peak current, the sensitivity of the Bi nanopowder electrode was quantitatively estimated. The detection limit of the electrode was estimated to be $0.15{\mu}g/l$ and $0.07{\mu}g/l$ for Cd and Pb, respectively, on the basis of the signal-to-noise characteristics (S/N=3) of the response for the $1.0{\mu}g/l$ solution under a 10 min accumulation.

Simultaneous Determination of Zinc, Cadmium, Lead and Copper in Tungsten Matrix by Differential Pulse Anodic Stripping Voltammetry (펄스차이 벗김전압전류법에 의한 텅스텐 중 아연, 카드뮴, 납 및 구리의 미량성분 동시분석)

  • Bae, Jun Ung;Lee, Seong Ho
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.146-150
    • /
    • 1994
  • The simultaneous determination of Zn, Cd, Pb and Cu in 1.000%(w/v) tungsten matrix by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode has been studied. Tartaric acid(pH=5.00) was used as a supporting electrolyte. Optimum analytical conditions were found that the deposition potential was -1.2 volt(vs. Ag/AgCl), the deposition time was 3 minutes. The linear concentration range of all trace metal ions in 1.000%(w/v) tungsten matrix were 10 to 50 ppb. And the detection limit(3${\sigma}$) of zinc, cadmium, lead and copper were 1.25, 1.02, 1.69, and 1.02 ppb respectively. This method was superior to the ICP-AES method which detection limits(3${\sigma}$) in 1.000%(w/v) tungsten matrix were 8.0, 5.0, 120 and 5 ppb respectively.

  • PDF

Evaluation of Separation on the Copper Recovery from Jelly filled type Cable (젤리충전통신케이블의 구리회수를 위한 친환경적 분리기술평가)

  • Min, Dal-Ki;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.21-26
    • /
    • 2003
  • The generation of waste cable has been continuously increased as a production of electrical and communication media are extended. The current recovery methods, such as mechanical peeling, incineration, solvent extraction and pyrolysis, seems inadequate because they are either hard to apply in some cases or environmentally unacceptable. It has been shown that copper can be effectively separated from the jelly filled type cables using a soybean oil treatment method. As a result, jelly compound is vanished from the wire by soybean oil bath and waste wires are separated copper and PE by the mechanical chipper. This is a more environmentally friendly method than burning, and considerably faster than Stripping.

Correction of the Sea Effect in the Magnetotelluric (MT) Data Using an Iterative Tensor Stripping During Inversion (MT 자료 역산과정에서 반복적인 Tensor Stripping을 통한 해양효과 보정)

  • Yang, Jun-Mo;Lee, Chun-Ki;Yoo, Hai-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.286-301
    • /
    • 2008
  • When magnetotelluric (MT) data are obtained in vicinity of the coast, the sea can distort observed MT responses, especially those of deep part of subsurface. We introduce an iterative method to correct the sea effect, based on the previous topographic correction method which removes the distortions due to topographic changes in seafloor MT data. The method first corrects the sea effect in observed MT impedance, and then inverts corrected responses in a model space without the sea. Due to mutual coupling between sea and subsurface structure, the correction and inversion steps are iterated until changes in each result become negligible. The method is validated for 1-D and 2-D structure using synthetic MT data produced by 3-D forward modeling including surrounding seas. In all cases, the method closely recovers the given structure after a few iterations. To test the applicability of the proposed method to field data, we generate synthetic MT data for the Jeju Island whose 1-D conductivity structure is well known, using 3-D forward modeling. The distortions due to the surrounding sea start to appear below the frequency about 1 Hz, and are relatively severe in the electrical field perpendicular to the coastline because of the location of the observation sites. The proposed method successfully eliminates the sea effect after three iterations, and both 1-D and 2-D inversion of corrected responses closely recover the given subsurface structure of the Jeju Island model.