• Title/Summary/Keyword: Stripping

Search Result 645, Processing Time 0.033 seconds

Using a Bismuth-film Glassy Carbon Electrode Based on Anodic Stripping Voltammetry to Determine Cadmium and Lead in a Standard Rice Flour (양극벗김전위법 비스무스막 유리탄소전극을 이용한 표준 쌀 분말 내 카드뮴과 납 측정)

  • Kim, Hak-Jin;Son, Dong-Wook;Mo, Chang-Yeon;Han, Jae-Woong;Kim, Gi-Young;Park, Sang-Won;Om, Ae-Son
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.377-381
    • /
    • 2009
  • Excessive presence of heavy metals in environment may contaminate plants and fruits grown in that area. Rapid on-site monitoring of heavy metals can provide useful information to efficiently characterize heavy metal-contaminated sites and minimize the exposure of the contaminated food crops to humans. This study reports on the evaluation of a bismuth-coated glassy carbon electrode for simultaneous determination of cadmium (Cd) and lead (Pb) in a NIST-SRM 1568a rice flour by anodic stripping voltammetry (ASV). The use of a supporting electrolyte 0.1 M $HNO_3$ at a dilution ratio (sample pretreated with acid digestion in a microwave oven: supporting electrolyte) of 1:1 provided well-defined, sharp and separate peaks for Cd and Pb ions, thereby resulting in strongly linear relationships between Cd and Pb concentrations and peak currents measured with the electrode ($R^2\;=\;0.97$, 0.99 for Cd and Pb, respectively). The validation test results for spiked standard solutions with different concentrations of Cd and Pb gave acceptable predictability for both spiked Cd and Pb ions with mean prediction errors of 6 to 30%. However, the applicability of the electrode to the real rice flour sample was limited by the fact that Cd concentrations spiked in the rice flour sample were overly estimated with relatively high variations even though Pb ion could be quantitatively measured with the electrode.

Pulmonary Hemodynamic Alterations Following Radical Hilar Stripping (폐문부박리가 폐혈류 역학에 미치는 영향)

  • Kwack, Moon Sub;Lee, Hong Kyun
    • Journal of Chest Surgery
    • /
    • v.9 no.1
    • /
    • pp.20-26
    • /
    • 1976
  • Author has performed experimental study on hemodynamic changes of lung following radical hilar stripping and contralateral pulmonary artery ligation. In view of hemodynamic changes in group 1 (right pulmonary artery ligation only) and group 2(left hilar stripping+right pulmonary artery ligation). group 2 showed remarkable decrease rate in oxygen uptake (P<0.001) and total pulmonary blood flow(P<0.001), and the more increase rate in mean pulmonary artery pressure(P<0.02) and total pulmonary vascular resistance (P<0.001). Meanwhile, the decrease percent of left lung vascular resistance was lower than group 1(P<0.001). The hemodynamic changes in group 1 returned to control range two weeks later. In the group 2, two dogs were expired as a result of atelectasis and pulmonary hypertension. Among allying 8 dogs, five months after operation, follow up studies performed in two dogs, which showed normal pulmonary hemodynamics similar to preoperative data. The altered blood gas values and decreased oxygen uptake are more remarkable in denervated lung, which may due to pulmonary hypertension and partly retained more secretion in bronchial trees than usual. Important factors of raising pulmonary vascular resistance and pulmonary artery pressure are considered as the increased blood flow to remaining left lung and dysfunction of pulmonary vascular bed to accept the increased blood flow after denervation. Loss of nerve innervation had a influence, to some extent, to the decrease of oxygen uptake and the increase of pulmonary vascular resistance and pulmonary artery pressure. There can be little question that denervation does impair the pulmonary hemodynamics, however, intact pulmonary nerve innervation is not absolutely essential for survival of the animal.

  • PDF

Adsorptive Stripping Voltammetric Determination of Sex Hormones in Medicines (의약물 중 성호르몬의 흡착벗김 전압-전류법 정량)

  • Kim, Il Kwang;Chun, Hyun Ja;Jang, Kyung Seon
    • Analytical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.133-140
    • /
    • 1994
  • The determination of sex hormones by adsorpive stripping voltammetry in $1.0{\times}10^{-2}M$ sodium hydroxide as supporting electrolyte has been investigated in the conditions as follows : 240sec. for deposition time, -0.80 volts deposition potential, medium size mercury drop, and 20mV/sec scan rate. Calibration curve has shown a linearlity in the range of $5.0{\times}10^{-9}M$ to $8.0{\times}10^{-7}M$ and the detection limits have been $8.0{\times}10^{-10}M$ for progesterone and $1.4{\times}10^{-9}M$ for testosterone propionate. This method has shown such a good sensitivity even in dilute solution that has been use full for analyzing sex hormones in medical supplies without interference of additives.

  • PDF

Recovery of Nickel Metal from the Spent FeCl$_3$ Etching Solution by Solvent Extraction and Chemical Reduction (FeCl$_3$ 에칭廢液으로부터 溶媒抽出과 化學沈澱에 의한 니켈金屬 回收)

  • Lee, Man-Seung;Kim, Myoung-Sik
    • Resources Recycling
    • /
    • v.14 no.3
    • /
    • pp.48-54
    • /
    • 2005
  • Solvent extraction and chemical reduction experiments have been performed to separate iron and nickel from a spent FeCl$_3$ etching solution and to recover nickel metal. It was possible to separate iron and nickel by extracting the spent solution with Alamine336. At the O/A ratio of 7:1, iron extraction percentage of 99% was obtained. In the stripping of the loaded organic with 0.01 M HCl solution, iron stripping percentage of 99% was obtained when the A/O ratio was 7:1. When the pH of the raffinate was controlled to be 10.5, nickel metal powder with 99% purity was obtained by using hydrazine as a reducing agent at 100$^{\circ}C$. A process was suggested to recover nickel metal from the spent FeCl$_3$ solution and to regenerate etching solution.

Separation of Copper & Cobalt by Solvent Extraction in Organic Acid Leaching Solution (유기산 침출용액에서 용매추출법에 의한 구리 및 코발트 분리)

  • Kim, Tae-Young;Ryu, Seong-Hyung;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.24 no.3
    • /
    • pp.3-10
    • /
    • 2015
  • A study has been made on the recovery & separation of cobalt and copper from organic acid leaching solution by solvent extraction. The experimental parameters such as the equilibrium pH, concentration of extractant and phase ratio were observed. Copper was extracted using LIX 84 and Cobalt was extracted using cyanex 272 and versatic acid 10. Experimental results showed that extraction percent of copper was 99% at above eq. pH 2.0 and then more than 90% of cobalt were extracted by cyanex 272 in eq. pH 6.0 and versatic acid 10 in eq. pH 7.5. Stripping of copper and cobalt from the loaded organic phases can be accomplished by sulfuric acid as a stripping reagent and 120 ~ 150 g/L of $H_2SO_4$ was effective for the stripping of copper and cobalt respectively. Finially, the basic optimal process for recovery of copper and cobalt from the bio-leaching solution was proposed.

Intra-Rater and Inter-Rater Reliability of Brain Surface Intensity Model (BSIM)-Based Cortical Thickness Analysis Using 3T MRI

  • Jeon, Ji Young;Moon, Won-Jin;Moon, Yeon-Sil;Han, Seol-Heui
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • Purpose: Brain surface intensity model (BSIM)-based cortical thickness analysis does not require complicated 3D segmentation of brain gray/white matters. Instead, this technique uses the local intensity profile to compute cortical thickness. The aim of the present study was to evaluate intra-rater and inter-rater reliability of BSIM-based cortical thickness analysis using images from elderly participants. Materials and Methods: Fifteen healthy elderly participants (ages, 55-84 years) were included in this study. High-resolution 3D T1-spoiled gradient recalled-echo (SPGR) images were obtained using 3T MRI. BSIM-based processing steps included an inhomogeneity correction, intensity normalization, skull stripping, atlas registration, extraction of intensity profiles, and calculation of cortical thickness. Processing steps were automatic, with the exception of semiautomatic skull stripping. Individual cortical thicknesses were compared to a database indicating mean cortical thickness of healthy adults, in order to produce Z-score thinning maps. Intra-class correlation coefficients (ICCs) were calculated in order to evaluate inter-rater and intra-rater reliabilities. Results: ICCs for intra-rater reliability were excellent, ranging from 0.751-0.940 in brain regions except the right occipital, left anterior cingulate, and left and right cerebellum (ICCs = 0.65-0.741). Although ICCs for inter-rater reliability were fair to excellent in most regions, poor inter-rater correlations were observed for the cingulate and occipital regions. Processing time, including manual skull stripping, was $17.07{\pm}3.43min$. Z-score maps for all participants indicated that cortical thicknesses were not significantly different from those in the comparison databases of healthy adults. Conclusion: BSIM-based cortical thickness measurements provide acceptable intra-rater and inter-rater reliability. We therefore suggest BSIM-based cortical thickness analysis as an adjunct clinical tool to detect cortical atrophy.

Recovery of Palladium from a Mixture of Pt, Pd and Rh by Solvent Extraction

  • Kim, berly S. Svalstad;Kim, Nam-Soo;Kenneth N. Han
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.482-488
    • /
    • 2001
  • Platinum group metals (pgm) are useful to many industries such as chemical, dental and medical, petroleum, refining, electrical and electronic, and automotive. Researchers at the South Dakota School of Mines and Technology and PGM Recovery Ltd. have developed jointly an environmentally sound and metallurgically efficient process for extracting these metals from secondary sources. Once these metals have been dissolved in the leach liquor, the individual metals mainly platinum, palladium, and rhodium, should be separated in order to recover the individual metals with high purity. During this investigation, solvent extraction has been chosen as the method used to achieve the separation and extraction of platinum, palladium, and rhodium from the leach liquor. There were three solutions used throughout this procedure: 1) Synthetic solution (200 ppm Pt 80 ppm Pd 20 ppm Rh; 300 ppm Pt, 180 ppm Pd 50 ppm Rh), and 2) Auto catalyst leach liquors (100 ppm Pt, 30 ppm Pd, 20 ppm Rh). The solvents investigated included Lix 84(2-hydroxy-5-nonylacetonphenone oxime in a mixture with 5-dodecylsalicyloxime), Lix 84-I, ACORGA CLX-50 (diester of pyridine 3,5 dicarboxylic acid), and di-hexyl sulfide. The extraction values achieved using ACORGA CLX-50, Lix 84, and Lix 84-I were respectively Pt (25%, 0% 0%), Pd (100%, 99.8%, 95.3%), and Rh (99.1%, 35.5%, 4.25%). The stripping processes for the Lix 84, and Lix 84-I were proven to be more involved than others. The solutions were required to be simultaneously heated and stirred. The percentages acquired through these processes yielded unsatisfactory results. The stripping procedure for the ACORGA CLX-50 was easier to execute, yet the percentage recovered from this process was also unsatisfactory. Overall the di-hexyl sulfide has proved to be the most successful organic for this procedure. The average percent extracted for palladium was excellent with 99.9% - 100% with very little Platinum and rhodium extracted. The ability of stripping palladium in ammonia solution was also found to be excellent.

  • PDF

The Optimization of Solvent Extraction Process of Iron Chloride Etching Waste Solution (염화철 에칭폐액의 용매추출공정 최적화에 관한 연구)

  • Park, Il-Jeong;Kim, Dae-Weon;Kim, Geon-Hong;Chae, Hong-jun;Lee, Sang-Woo;Jung, Hang-Chul
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.279-285
    • /
    • 2017
  • In this study, a new organophosphorus acid-based solvent (KMC-P) from KMC Co., Ltd. was used for the recovery of the iron chloride etching waste solution. In order to increase the extraction efficiency for the new solvent in the solvent extraction process, we selected the process variables and conducted the optimization experiment according to the DOE to investigate the correlation between the variables. Solvent concentration, pH, and O/A ratio were found to be factors affecting extraction and stripping efficiency. The optimum stripping efficiency was 69.7% when the solvent concentration was 29.4 wt%, the HCl addition amount was 0 mL, and the O/A ratio was 7, and the reliability was more than 86%.

On the origin of gas deficient galaxies in galaxy clusters: insights from cosmological hydrodynamic simulations

  • Jung, Seoyoung;Choi, Hoseung;Wong, O. Ivy;Kimm, Taysun;Chung, Aeree;Yi, Sukyoung K.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.33.2-34
    • /
    • 2018
  • Galaxies associated with massive groups/clusters are normally gas deficient in contrast to field galaxies. HI observations on such galaxies have revealed signs of violent gas stripping, the direct evidence of the environmental effect. At the same time, the notable number of passive galaxies at the cluster outskirts indicates the presence of pre-processing that makes galaxies gas-poor before entering clusters. We investigate the possible channels for the production of the gas deficient galaxies using the state-of-the-art cosmological hydrodynamic zoom-in simulations of 16 clusters (Choi&Yi). We find cluster effect and pre-processing together play an important role in producing the gas-poor galaxies and in both cases gas loss qualitatively agrees with the ram pressure stripping description. Among the currently gas-poor cluster galaxies, 34% are pre-processed before the cluster infall. They are mainly satellites that have undergone ram pressure stripping in group halos. 43% deplete quickly after arriving at cluster during their first approach to the center. Some of them are group halo satellites low in the gas at the infall compared to galaxies directly coming from the field. 24% retain gas even after their first pericentric pass mainly because they are falling into low mass clusters and/or they have a circular orbit that minimizes the ram pressure effect. This study highlights the importance of the past history of galaxies, especially in group halos, before joining the current cluster when understanding the excess of passive galaxies in clusters.

  • PDF

Ex Vivo Assay of Trace Nicotine Using a Voltammetric Modified Biosensor

  • Ly, Suw Young;Jang, Myung-Ho;Cha, Jae-Min;Kim, Min-Young;Oh, Hyun-Seok;Jo, Dong-Hyeon;Choi, Seong-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.40-46
    • /
    • 2012
  • In vivo nicotine is associated with Alzheimer's, Parkinson's and lung cancer. Diagnostic assays of these diseases depend on very low analytical detection limits. In this study, a sensitive analytical method was examined using a voltammetric graphite pencil electrode (GPE) and a modified carbon nanotube paste electrode (CNE). The optimum analytical conditions for both electrodes were compared using square wave anodic stripping voltammetry (SW) and cyclic voltammetry (CV) obtaining 400 sec accumulation time and oxidation peak. Under optimum parameters, the stripping working range of GPE was $5.0-40.0{\mu}g/L$, CNE: 0.1-0.8 and $5-50{\mu}g/L$. Quantification limits were $5.0{\mu}g/L$ for GPE and $0.1{\mu}g/L$ for CNE, while detection limits were $0.6{\mu}g/L$ for GPE and $0.07{\mu}g/L$ for CNE. A standard deviation of $10.0{\mu}g/L$ was observed for 0.064 GPE and 0.095 CNE (n = 12) using 400 sec accumulation time. The results obtained can be applied to non.treated urine and ex vivo biological diagnostics.