• Title/Summary/Keyword: Strip sensor

Search Result 88, Processing Time 0.028 seconds

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.

  • PDF

Development of Eco-Friendly Paper Glucose Bio-Sensor (친환경 종이 혈당 비이오센서 개발)

  • Kim, A-Young;Lee, Young-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.202-206
    • /
    • 2013
  • In this paper, a disposable glucose sensor was made of paper. Glucose sensor strip using carbon electrode is appropriate for the low price ones because it requires cheap materials and low cost production. Most of blood glucose sensors were developed with plastics, but it causes pollution problems. Therefore we developed disposable carbon electrode glucose sensor using paper. This sensor consists of upper and bottom plate. On the upper plate, three-dimensional channel are formed through pressing process. The fabricated paper glucose sensor shows relatively short sensing time of about 5seconds, excellent reproducibility ($R^2$=0.9558), and fabrication yield as well.

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).

Target Positioning in Remote Area Using Strip Sensor Modeling of SPOT Imagery (SPOT 위성영상의 스트립 센서모델링을 이용한 비접근지역 위치결정 연구)

  • Kim, Man-Jo;Hwang, Chi-Jung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.155-160
    • /
    • 2012
  • In this paper, a strip modeling method is developed for the acquisition of target positions in remote area and validated using the imagery of SPOT satellite. This method utilizes the parameters given in header files and constructs a camera model without ground control points. In most cases, the root mean squared error of check points is less than pixel size with one ground control point. The model error of reference image is evaluated using ground control points and used to remove the model error of target images acquired along the same satellite orbit, which enables one to calculate target positions in remote area where no ground control points are available.

Speed and Tension Control of Continuous Strip Processing Line using Continuous Load Balance Control (연속 부하 분담 제어를 이용한 연속 구동 시스템의 속도 및 장력 제어 특성 개선)

  • Song, Seung-Ho;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.503-509
    • /
    • 1999
  • This paper proposes a new speed and tension control algorithm for multi-span continuous strip processing line. In this algorithm the speed reference of each roll is adjusted to make the output force follow the load balance reference using an outer loop controller in cascade. Using the information of the output force of the adjacent roll, it is shown that the strip tension between two rolls can be controlled as the desired value without tension sensor. An experimental set-up which consists of 4 driven and 3 measuring rolls is designed and built for the multi-span speed and tension control. The experimental result reveals conspicuous improvement of tension control performance by the proposed algorithm comparing to the conventional tension feedback controller.

  • PDF

Development of Paper Blood Glucose Sensor with Minimal Hematocrit Effect (헤마토크릿 영향을 최소화한 종이 혈당센서 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.116-120
    • /
    • 2022
  • In this paper, we developed a paper blood glucose sensor that can minimize the effect of hematocrit. The paper blood glucose sensor has the advantage of being very simple in its production process as it is manufactured with only three printing processes on the top of the paper substrate. This glucose sensor consists of a total of six electrodes, including blood glucose measurement electrodes, hematocrit measurement electrodes, strip detection electrodes, and blood detection electrodes. A paper blood glucose sensor measures hematocrit with electrodes formed on the same sensor substrate when measuring blood glucose concentration, and compensates for the effect of hematocrit in real time to enable accurate blood glucose measurement.

Development of Single-layer Glucose Sensor Using GDH-FAD (Glucose Dehydrogenase Flavin Adenine Dinucleotide)

  • Kye, Ji-Won;Lee, Young-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.156-159
    • /
    • 2018
  • We developed a glucose sensor using glucose dehydrogenase flavin adenine dinucleotide (GDH-FAD). The structure of the three-layer glucose sensor was simplified, in which a single-layer design was used to lower the unit cost, and GDH-FAD was used to increase the measurement reliability. GDH-FAD has less impact on the 20 interfering substances that affect blood glucose measurement, such as galactose and maltose compared to glucose oxidase (GOD), and is not affected by the oxygen saturation; therefore, it is possible to measure both arterial or venous blood and thus less susceptibility to hematocrit. In this study, we developed a single-layer glucose sensor strip with low hematocrit effect using the GDH-FAD enzyme, and measured and evaluated the performance.

A Study on the Monitoring System for Engine Control by Measuring Combustion Pressure Continuously in All Cylinders

  • Miharat Yoshinori;Maruyama Yasuo;Okada Yutaka;Kido Hachiro;Nishida Osami;Fujita Hirotsugu;Ito Masakazu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.713-721
    • /
    • 2005
  • A marine diesel engine should realize optimal operation efficiency while reducing NOx, PM (Particulate Matters) and other emissions. Fuel injection systems that use electronic control can become an effective means of achieving that objective. However. it still needs some accurate and instant information in order to bring its ability into full potential while sailing on the sea. The important information of them are a shaft torque and continuous combustion pressures of all cylinders. The shaft torque and the propeller thrust described in this paper are measured at an intermediate shaft by using a unique principle that one of two electromagnet coils oscillates a vibrating strip which the length changes with force and the other coil picks up the change of the frequency of the vibrating strip. For further reference, the shaft power meter multiplied the torque by the shaft revolution has already had about 750 sets of sales performance. The research presented in this paper started about ten years ago and is concerned with the development of a combustion pressure sensor that uses the same principle. Recently, the pressure sensor which bears continuous operation has been developed after a hard struggle, that is, the system that consists of a shaft horsepower meter, a propeller thrust meter and a combustion pressure sensor has been completed and has been shown to be reliable. This paper describes the configuration of this system, the material of the combustion pressure sensor, the principle of that, and the improving point of the sensor, and, we finally consider the use of this system.

Rapid Nutrient Diagnosis of Cucumber by Test Strip and Chlorophyll Meter (Test Strip과 Chlorophyll Meter를 이용한 오이의 신속한 영양진단)

  • Kim, Kwon-Rae;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.5
    • /
    • pp.272-279
    • /
    • 2003
  • This study was performed to develop a more rapid and simple nutrient diagnosis method of plants than the conventional leaf analysis method. Cucumber (Cucumis sativus L. cv. jangil banbaek) was planted in the mixed media produced by mixing perlite and rock wool at 1:1 (v/v) ratio. The Yamazakki nutrient solution for cucumber was supplied to the media using micro-drip irrigation system. Experimental plots were consisted of no fertilization, deficient fertilization, adequate fertilization, and surplus fertilization for N, P and K. Specific color difference sensor value (SCDSV) measured by chlorophyll meter was closely related to total-N concentration in leaves measured by the conventional method. Nitrate, $PO_4$ and K concentration in petiole sap measured by test strips showed a significant relationship with total-N, P and K concentration in leaves. Linear regression equations between $NO_3$, $PO_4$ and K concentration in petiole sap and total-N, P and K concentration in the leaves were prepared. Optimum levels of $NO_{3}$, $PO_{4}$ and K in petiole sap were obtained by plugging the optimum concentrations of total-N, P and K in the leaves by other researchers into the equations. In conclusion, the SCDSV measured by chlorophyll meter and the concentration of $NO_3$, P and K in petiole sap measured by the test strips would be suitable for rapid estimation of plant nutrient status.

Sensitivity Improvement of Fiber Bragg Grating Temperature Sensor (광섬유격자 온도센서의 민감도 개선)

  • Kang, Han-Chul;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.40-45
    • /
    • 2012
  • We substantially increased the temperature sensitivity of a fiber Bragg grating temperature sensor by gluing it onto a piece of bi-metal strip. The temperature-induced Bragg wavelength shift is increased upto 5 times more than that of the intrinsic FBG sensor by the strain effect from the deflected bi-metal. We showed the feasibility of the proposed sensor by comparing the temperature measuring experiments with those of the intrinsic FBG sensors. Also we measured temperature varying the length of the bi-metal pieces and analyzed the result effect of it.