• Title/Summary/Keyword: Strip device

Search Result 83, Processing Time 0.027 seconds

Cu as an Electrode Material in TFT-LCD Products

  • Park, C.W.;Cho, W.H.;Kim, K.T.;Choi, H.C.;Oh, C.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.661-663
    • /
    • 2003
  • In this paper, production of TFT-LCD adopting Cu electrode, in spite of low resistivity, which was not commercially applied to TFT LCD products because of processibility, reliability problems etc. was mentioned. Based on the test result of etch and strip process of Cu electrode, the TFT device using Cu material shows the same characteristics as the conventional TFT devices. We describe the realization of a 20.1" UXGA model which was firstly applied to Cu electrode.

  • PDF

Sensitivity of an Anisotropic Magnetoresistance Device with Different Bias Conditions

  • Kim, T.S.;Kim, K.C.;Kim, Kibo;K. Koh;Y.J. Song;Song, Y.S.;Suh, S.J.;Kim, Y.S.
    • Journal of Magnetics
    • /
    • v.6 no.1
    • /
    • pp.36-41
    • /
    • 2001
  • A micromagnetic model and a single-domain model simulation programs were used to analyze the sensitivity of a $20\mu m\times 60\mu m \times 1000{\AA}$ permalloy strip as a magnetoresistance sensor with bias fields of various directions and magnitudes. The micromagnetic model agrees with the measured sensitivity data better than the single-domain model. The data show the highest peak sensitivity with the bias field at 90$^{\circ}$to the current. The peak sensitivity decreases and the peak broadens as the bias angle decreases. The simulation using the micromagnetic model shows that a bias angle smaller than 90$^{\circ}$eads to magnetization patterns which are free from closure domains or vertices over a wider range of bias fields.

  • PDF

Highly Stretchable, Transparent Ionic Touch Panel

  • Sun, Jeong-Yun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.51-63
    • /
    • 2017
  • The touch panel was developed decades ago and has become a popular input device in daily life. Because human-computer interaction is becoming more important, the next generation of touch panels require stretchability and bio-compatibility to allow integration with the human body. However, because most touch panels were developed based on stiff, brittle electrodes, electronic touch panels face difficulties to achieve such requirements. In this paper, for the first time, we demonstrate an ionic touch panel based on polyacrylamide hydrogel containing LiCl ions. The panel is soft and stretchable and thus, can sustain a large deformation. The panel can freely transmit light information through it because the hydrogel is transparent, with 99 % transmittance for visible light. A 1-dimensional touch strip was investigated to reveal the basic mechanism of sensing, and a 2-dimensional touch panel was developed to demonstrate its functionalities. The ionic touch panel was operated under high deformation with more than 1000% areal strain without sacrificing its functionalities. Furthermore, an epidermal touch panel on the skin was developed to demonstrate the mechanical and optical invisibility of the ionic touch panel through writing words, playing the piano and playing games.

  • PDF

Ti Capping Layer에 의한 Co-silicide 박막의 형성에 관한 연구

  • ;;;;;;;;Kazuyuki Fujigara
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.61-61
    • /
    • 2000
  • Device의 고성능화를 위하여 소자의 고속화, 고집적화가 가속됨에 따라 SALICIDE Process가 더욱 절실하게 요구되고 있다. 이러한 SALICIDE Process의 재료로써는 metal/silicide 중에서 비저항이 가장 낮은 TiSi2(15-25$\mu$$\Omega$cm), CoSi2(17-25$\mu$$\Omega$cm)가 일반적으로 많이 연구되어 왔다. 그러나 Ti-silicide의 경우 Co-silicide는 배선 선폭의 감소에 따른 면저항 값의 변화가 작으며, 고온에서 안정하고, 도펀트 물질과 열역학적으로 안정하여 화합물을 형성하지 않는다는 장점이 있으마 Ti처럼 자연산화막을 제거할 수 없어 Si 기판위에 자연산화막이 존재시 균일한 실리사이드 박막을 형성할 수 없는 단점등을 가지고 있다. 본 연구에서는 Ti Capping layer 에 의한 균일한 Co-silicide의 형성을 일반적인 Si(100)기판과 SCl 방법에 의하여 chemical Oxide를 성장시킨 Si(100)기판의 경우에 대하여 연구하였다. 스퍼터링 방법에 의해 Co를 150 증착후 capping layer로써 TiN, Ti를 각각 100 씩 증착하였다. 열처리는 RTP를 이용하여 50$0^{\circ}C$~78$0^{\circ}C$까지 4$0^{\circ}C$ 구간으로 N2 분위기에서 30초 동안 열처리를 한후, selective metal strip XRD, TEM의 분석장비를 이용하여 관찰하였다. lst RTP후 selective metal strip 후 면저항의 측정과 XRD 분석결과 낮은 면저항을 갖는 CoSi2로의 상전이는 TiN capping과 Co 단일박막이 일반적인 Si(100)기판과 interfacial oxide가 존재하는 Si(100)기판위에서 Ti capping의 경우보다 낮은 온도에서 일어났다. 또한 CoSi에서 CoSi2으로 상전이는 일반적인 Si(100)기판위에서 보다 interfacial Oxide가 존재하는 Si(100)기판 위에 TiN capping과 Co 단일박막의 경우 열처리 후에도 Oxide가 존재하는 불균인한 CoSi2박막을 관찰하였으며, Ti capping의 경우 Oxise가 존재하지 않는 표면과 계면이 더 균일한 CoSi2 박막을 형성 할 수 있었다.

  • PDF

A Study on the Attenuation of Flip-over Vibration in the Flat Blade Windshield Wiper (플랫 블레이드 윈드실드 와이퍼의 역전 진동 저감에 관한 연구)

  • Lee, Hyeong-Ill
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.974-984
    • /
    • 2012
  • This research introduces a new method to attenuate flip-over vibration generation in the flat blade windshield wiper by adjusting the contact pressure between the windshield glass and the blade. The knocking force in the flip-over action of the blade is decreased by inducing gradual tilting-over along the rubber strip of the blade. This gradual tilting-over is induced by introducing a non-uniform contact pressure distribution between the blade and windshield glass. The contact pressure distribution is adjusted by controlling the unloaded profile of the body spring in the blade using a procedure proposed in a previous study. Two blades, one blade designed to generate a uniform pressure distribution and the other designed to generate non-uniform pressure distribution, are developed using the procedure. Contact pressure distributions of the developed blades are measured using a special device and compared with the intended distributions confirming the similarities between the two groups. Vertical and lateral vibrations of the two blades are measured under realistic operating condition simulated by a wiper test rig. The vertical vibrations of the blade with non-uniform contact pressure are substantially smaller than corresponding vibrations of the blade with uniform contact pressure over the entire rubber strip.

Seismic Characteristic Evaluation on Strip-type Damping Devices with Optimized Shape (최적 형상 스트립형 감쇠장치의 내진 특성 평가)

  • Hwang, Jung-Hyun;Ock, Jong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.26-37
    • /
    • 2019
  • This paper aims to investigate the seismic characteristics of strip-type damping devices possessing optimized shapes for the moment-resisting mechanism throughout analytical and experimental studies. Predicting equations for initial stiffness and yielding strength were introduced and compared with analytical results obtained from finite element analyses (FEAs) using commercial FEA program ABAQUS. In order for establishing predicting equations, two idealized processes were considered and both predicting equations showed that they could provide enough approximations for seismic applications in building structures. Throughout experimental studies, it was noted that structural uncertainties on mild steels, connection details and structural types linking damping devices with building structures could interrupt predicting structural behavior of the devices. Also, it was observed that shear stress concentrations should be considered if shear yielding type devices are applied into building structures. Nevertheless, it was shown that structural conservatism can be established using the predicting equations and seismic applications of the damping devices can enhance the seismic performance of building structures efficiently in the viewpoint that they have high resistance to low-cycle fatigue failures.

Development of Large-area Plasma Sources for Solar Cell and Display Panel Device Manufacturing

  • Seo, Sang-Hun;Lee, Yun-Seong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.148-148
    • /
    • 2011
  • Recently, there have been many research activities to develop the large-area plasma source, which is able to generate the high-density plasma with relatively good uniformity, for the plasma processing in the thin-film solar cell and display panel industries. The large-area CCP sources have been applied to the PECVD process as well as the etching. Especially, the PECVD processes for the depositions of various films such as a-Si:H, ${\mu}c$-Si:H, Si3N4, and SiO2 take a significant portion of processes. In order to achieve higher deposition rate (DR), good uniformity in large-area reactor, and good film quality (low defect density, high film strength, etc.), the application of VHF (>40 MHz) CCP is indispensible. However, the electromagnetic wave effect in the VHF CCP becomes an issue to resolve for the achievement of good uniformity of plasma and film. Here, we propose a new electrode as part of a method to resolve the standing wave effect in the large-area VHF CCP. The electrode is split up a series of strip-type electrodes and the strip-type electrodes and the ground ones are arranged by turns. The standing wave effect in the longitudinal direction of the strip-type electrode is reduced by using the multi-feeding method of VHF power and the uniformity in the transverse direction of the electrodes is achieved by controlling the gas flow and the gap length between the powered electrodes and the substrate. Also, we provide the process results for the growths of the a-Si:H and the ${\mu}c$-Si:H films. The high DR (2.4 nm/s for a-Si:H film and 1.5 nm/s for the ${\mu}c$-Si:H film), the controllable crystallinity (~70%) for the ${\mu}c$-Si:H film, and the relatively good uniformity (1% for a-Si:H film and 7% for the ${\mu}c$-Si:H film) can be obtained at the high frequency of 40 MHz in the large-area discharge (280 mm${\times}$540 mm). Finally, we will discuss the issues in expanding the multi-electrode to the 8G class large-area plasma processing (2.2 m${\times}$2.4 m) and in improving the process efficiency.

  • PDF

Application of Reduce Tillage with a Strip Tiller and its Effect on Soil Erosion Reduction in Chinese Cabbage Cultivation (배추 재배에 있어 경운방법에 따른 작업효율성 및 토양유실 특성 평가)

  • Lee, Jeong-Tae;Lee, Gye-Jun;Ryu, Jong-Soo;Hwang, Seon-Woong;Park, Suk-Hoo;Zhang, Yong-Seon;Jeong, Yeong-Sang
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.970-976
    • /
    • 2011
  • Strip tiller equipment was developed to reduce soil erosion in the slope land for highland agricultural area. The equipment consisted of 4 rows strip tillage device and fertilizer applicator. The field was tilled in 10 cm width and in 10 cm depth by the equipment, of which tilled surface was 16.7% of full-width tillage. The working time and fuel consumption of the equipment were $3.8hours\;ha^{-1}$ and $24.4L\;ha^{-1}$ respectively, which were 59% and 74% less than those of the conventional tillage. Fertilizer efficiency of the equipment in cultivation of Chinese cabbage was 1.7, 1.6 and 1.5 times higher in nitrate, phosphorous and potassium respectively, than conventional tillage. When the equipment was used after covering of rye residue, the quantity of runoff was 49~67% lower than the conventional tillage. And the quantity of soil loss were 1.3 and $0.2Mg\;ha^{-1}$ at right after and 30 days after planting of Chinese cabbage respectively, while 11.5 and $4.1Mg\;ha^{-1}$ in conventional tillage. In conclusion, the strip tillage equipment developed in this study can be applicable to slope land, so that soil loss of 90% can be reduced.

EVALUATION OF TIGHTNESS OF PROXIMAL TOOTH CONTACT IN PERMANENT DENTITION

  • Kim, Kyoung-Hwa;Jung, Jae-Hyun;Kim, Hee-Jung;Chung, Chae-Heon;Oh, Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.553-560
    • /
    • 2008
  • STATEMENT OF PROBLEM: Proximal contact plays an important role in the stability and maintenance of the integrity of the dental arches. However, it is difficult to evaluate quantitatively the tightness of proximal tooth contact (TPTC). PURPOSE: The aim of this study was to measure the TPTC in permanent dentition. MATERIAL AND METHODS: Ten young adult volunteers with healthy dentition participated in this experiment. The TPTC between the teeth of both the maxilla and the mandible was measured at rest state by a novel device which records the TPTC by pulling of a stainless steel strip (0.03 mm thick) using the electric motor. One-way ANOVA test was used to compare the values in all measured area. When a statistically significant difference was calculated, Bonferroni correction was applied. Independent samples t-test was used to compare the values in male and female. RESULTS: The lowest TPTC and the highest TPTC was measured between the lower central incisors (0.87 ${\pm}$ 0.20 N), and between the lower left first molar and second molar (1.99 ${\pm}$ 0.68 N), respectively. All TPTC per quadrant demonstrated a similar pattern of a continuous increased gradient in an anterior-posterior direction. There are no significant difference between the maxilla and mandible. CONCLUSION: The TPTC was measured quantitatively by a novel device and decreased progressively in a posterior-anterior direction.

Carbonization Patten and Operation Characteristics of a 1Φ 2 W MCCB Damaged by PCITS (PCITS에 의해 소손된 1Φ 2 W MCCB의 탄화 패턴 및 작동 특성)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.8-13
    • /
    • 2014
  • The purpose of this study is to analyze the damage pattern when overcurrent is applied to a thermal magnetic type molded case circuit breaker (MCCB) using a Primary Current Injection Test System (PCITS). When an overcurrent of 150 A was applied to the PCITS for 5 seconds with the trip bar of an MCCB being damaged, it was found that the surface of the temperature control device (bimetallic strip) positioned at the right was significantly carbonized. When an overcurrent of 300 A was applied to the PCITS for 5 s under the same conditions, the entire temperature control device was deteriorated, becoming flattened and in close contact with the MCCB. When an overcurrent of 450 A was applied to the PCITS for 5 s, the coil of the temperature control device was melted and disconnected. In addition, it was observed that the contacts, the enclosure and upper cover were deformed and there was a trace of carbonization on them. When approximately 3 s had elapsed after an overcurrent of 600 A was applied, white smoke occurred inside the MCCB and a flame was radiated out, after which the overcurrent supply stopped with "phutt" (whomp) sound. It was observed that when the same type of MCCB is damaged by a general flame, the surfaces of its handle, terminal, arc divider (extinguisher) and temperature control device were carbonized uniformly. In addition, it was found that the trip bar of the operating mechanism was melted down and the metal operation pin was moved while being tripped.