• 제목/요약/키워드: String-stability

검색결과 30건 처리시간 0.022초

광섬유 브래그 격자 센서를 이용한 절대 변형률 측정 (Absolute Strain Measurement Using Fiber Bragg Grating Sensor)

  • 송인천;;이병하;이선규;정성호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.416-420
    • /
    • 2002
  • This Paper describes a matched-filter type strain sensor system using optical fiber Bragg grating (FBG) sensor. Matched-filter type uses another wavelength-matched FBG filter to track wavelength shift in the FBG sensor. Filter FBG is attached on a fiber stretcher and stretched by PZT actuator. To overcome the nonlinearity and hysteresis of the PZT actuator that degrades system accuracy, a string resonator which can measure an absolute strain is employed. And the effect of vibration modes on string resonator is investigated particularly regarding its sensitivity and stability.

  • PDF

보-스트링 구조의 횡 좌굴에 관한 연구 (A Study on Lateral Buckling of Beam String Structures)

  • 김재열
    • 한국공간구조학회논문집
    • /
    • 제13권4호
    • /
    • pp.49-56
    • /
    • 2013
  • Beam string structures(BSS) are one kind of efficient structure system because the bending moment in the beams is reduced greatly through the struts and the strings. As the struts in BSS are used as middle supports to the beam and always in compression, the buckling of the struts should be avoided. This paper investigates the lateral buckling of the struts in BSS. Firstly, the strut of a one-strut BSS is simplified into an analytical model by considering load is formulated and some special cases of the model are analyzed. Finally, the lateral buckling load of the strut is numerically examined by means of parameter studies. It is known that, because on end of the struts is jointed to the beam while the other end is connected to the strings, the buckling of the struts not only depends on the length of the struts and the stiffness of the joints, but also depends on the rise and the lateral stiffness of the beam, the layout of the strings and the number of the struts.

Linear elastic and limit state solutions of beam string structures by the Ritz-method

  • Xue, Weichen;Liu, Sheng
    • Structural Engineering and Mechanics
    • /
    • 제35권1호
    • /
    • pp.67-82
    • /
    • 2010
  • The beam string structure (BSS) has been widely applied in large span roof structures, while no analytical solutions of BSS were derived for it in the existing literature. In the first part of this paper, calculation formulas of displacement and internal forces were obtained by the Ritz-method for the most commonly used arc-shaped BSS under the vertical uniformly distributed load and the prestressing force. Then, the failure mode of BSS was proposed based on the static equilibrium. On condition the structural stability was reliable, BSS under the uniformly distributed load would fail by tensile strength failure of the string, and the beam remained in the elastic or semi-plastic range. On this basis, the limit load of BSS was given in virtue of the elastic solutions. In order to verify the linear elastic and limit state solutions proposed in this paper, three BSS modal were tested and the corresponding elastoplastic large deformation analysis was performed by the ANSYS program. The proposed failure mode of BSS was proved to be correct, and the analytical results for the linear elastic and limit state were in good agreement with the experimental and FEM results.

어깨통증을 가진 전문 오케스트라 현악기 연주자에게 적용한 운동프로그램이 통증과 기능수준, 자세 특성에 미치는 효과: 사례군 연구 (Effects of Exercise Program on Pain, Functional Level and Posture Characteristics for Professional Orchestra High String Musicians with Shoulder Pain: Case Series)

  • 신혜원;김선엽
    • 한국전문물리치료학회지
    • /
    • 제25권3호
    • /
    • pp.39-50
    • /
    • 2018
  • Background: High string instrument (violin, viola) players are at high risk for developing musculoskeletal problems. In particular, a higher prevalence of shoulder problems has been reported. However, evidence of the effectiveness of therapeutic exercise for musicians with this condition is lacking until now. Objects: This case series study investigated the effect of a specific exercise program on shoulder pain, dysfunction, and posture of professional orchestral high string musicians. Methods: Five professional orchestral high string players with shoulder pain participated in this study. A six-week specific exercise program focus on scapular stability for shoulder pain consisted of scapular muscle exercise. Physical examinations for pain and dysfunction, posture were performed, were identified among all subjects before starting the exercise program. Results: The results revealed that shoulder pain decreased by 67.86% and the effect of pain on instrument play decreased by 63.33%. The shoulder pain and disability Index and the performing arts module-quick disability of the arm, shoulder and hand scale decreased by 71.72% and 51.61% respectively. The exercise program improved function and posture. Conclusion: A specific exercise program for high string players was effective in managing shoulder pain. This case series is intended to provide empirical data on the effectiveness of an exercise program aimed at assessing the effect of exercise on pain, dysfunction, and posture of professional orchestra musicians associated with specific instrument groups.

MGPSS를 이용한 전력계통안정도 해석 (A Study on the Analysis of Power System Stability using MGPSS)

  • 이상근;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.165-167
    • /
    • 2007
  • This paper presents a analysis method for power system stability using a Modified Genetic-based Power System Stabilized(MGPSS). The proposed MGPSS parameters are optimized using Modified Genetic Algorithm(MGA) in order to maintain optimal operation of generator under the various operating conditions. To improve the convergence characteristics, real variable string is adopted. The results tested on a single machine infinite bus system verify that the proposed controller has better dynamic performance than conventional controller.

  • PDF

축방향으로 이동하며 길이가 변하는 연속체의 자유 진동 및 동적 안정성 (Free Vibration and Dynamic Stability of the Axially Moving Continuum with Time-varying Length)

  • 사재천;이민형;이승엽
    • 한국소음진동공학회논문집
    • /
    • 제12권4호
    • /
    • pp.272-279
    • /
    • 2002
  • The time-dependent frequency and energy of free vibration of the spagetti problem, that is the axially moving continuum with time-varying length, are investigated. Exact expressions for the natural frequency and time-varying vibration energy are derived by dealing with traveling waves. The vibration period increases with increasing length, but the free vibration energy decreases. When the string undergoes retraction, the vibration energy increases with time. The free response of the time-varying string is represented by superposing two traveling waves.

MGPSS를 이용한 전력계통안정도 해석 (A Study on the Analysis of Power System Stability using MGPSS)

  • 이상근
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.14-17
    • /
    • 2015
  • This paper presents a analysis method for power system stability using a Modified Genetic-based Power System Stabilizer(MGPSS). The proposed MGPSS parameters are optimized using Modified Genetic Algorithm(MGA) in order to maintain optimal operation of generator under the various operating conditions. To improve the convergence characteristics, real variable string is adopted. The results tested on a single machine infinite bus system verify that the proposed controller has better power system stability than conventional controller.

개방성 치조골 골절의 고정법: 응급실에서 간편하게 적용할 수 있는 방법 (Fixation of Open Alveolar Bone Fractures: Easily Applicable Method in the Emergency Department)

  • 설승환;차수현;최상천;안정환;김기운;최혜경;조준필;정윤석
    • Journal of Trauma and Injury
    • /
    • 제20권2호
    • /
    • pp.72-76
    • /
    • 2007
  • Purpose: The purpose of this clinical trial was to evaluate the fixation method for treating alveolar fractures in an emergency department. Methods: The efficiency of using the fixation method was judged on the basis of clinical criteria. Stability, occlusion state, bleeding amount after fixation, operation time, and difficulties during procedural operation were recorded. Results: Eight patients were enrolled in this study. In all instances, the fixation method was effective in bleeding control. Each patient had a noticeable decrement in bleeding. A wire was used for four of the eight patients, and nylon strings was used for the others. The average operation time was 6.3 minutes for the wire patients and 2.8 minutes for the Nylon string patients. No specific problem was identified during the procedural operation. However, the difference in the fixation material influenced the effectiveness of the procedure, the operation time, and the satisfaction of the doctor. Conclusion: In the emergency department, the fixation method using wire or nylon string in the treatment of alveolar fractures is effective in bleeding control

전력 최적제어 기능을 가진 LED 드라이버 설계 (LED Driver Design with Power Optimum Control Function)

  • 이승우;신홍규;조성익
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.253-256
    • /
    • 2011
  • LEDs have small size, long lifespan, high reliability, low power consumption and high color efficiency. Using such a characteristics, LED Back Light Unit has been studying actively. This paper proposes LED driver to minimize power consumption due to LED forward voltage($V_F$) difference and temperature rising. Compared to conventional LED driver, the proposed driver have excellent stability, brief structure and linear output voltage of DC-DC boost converter. Proposed LED Driver circuit was designed using 0.35um CMOS technology. And its operation was verified through simulation.

고정도 챔퍼링 공구 셋트의 개발 (A Development of High-Precision Chamfering Tool Set)

  • 김철;최용훈;소병환;김창호
    • 한국기계가공학회지
    • /
    • 제14권1호
    • /
    • pp.117-122
    • /
    • 2015
  • There has been a string of negligent accidents at the seaside, and there is presently a shortage of professional equipment to deal with such accidents. The purpose of this paper is to assess the development of a rescue lift. The critical load of a support pipe, and the stability of the rescue lift, were investigated using structural analysis. Critical-load analysis was used to study the effects of variations in the pipe length and the ratio of the moment of inertia. The total weight of the developed rescue lift is approximately 20.7 kg, and the lift passed the load tests.