• 제목/요약/키워드: Stress gradient

검색결과 511건 처리시간 0.025초

선천성 대동맥 협착증의 술전 및 술후 단기간의 수축말기 좌심실 내벽 스트레스의 변화 (Alterations in Left ventricular End-systolic Wall Stress During Short-term Follow-up After Correction of Isolated Congenital Aortic Stenosis)

  • 김시호
    • Journal of Chest Surgery
    • /
    • 제33권10호
    • /
    • pp.777-784
    • /
    • 2000
  • Congenital aortic stenosis in children is characterized by "excessive" left ventricular hypertrophy with reduced left ventricular systolic wall stress that allows for supernormal ejection performance. We hypothesized that left ventricular wall stress was decreased immediately after surgical correction of pure congenital aortic stenosis. Also measuring postoperative left ventricular wall stress was a useful noninvasive measurement that allowed direct assessment for oxygen consumption of myocardium than measuring the peak systolic pressure gradient between ascending aorta and left ventricle for the assessment of surgical results. Material and Method: Between September 1993 and August 1999, 8 patients with isolated congenital aortic stenosis who underwent surgical correction at Yonsei cardiovascular center were evaluated. There were 6 male and 2 female patients ranging in age from 2 to 11 years(mean age, 10 years). Combined Hemodynamic-Ultrasonic method was used for studying left ventricular wall stress. We compared the wall stress peak systolic pressure gradient and ejection fraction preoperatively and postoperatively. Result: After surgical correction peak aortic gradient fell from 58.4${\pm}$17.6, to 23.7${\pm}$17.7 mmHg(p=0.018) and left ventricular ejection fraction decreased but it is not statistically significant. In the consideration of some factors that influence left ventricular end-systolic wall stress excluding one patient who underwent reoperation for restenosis of left ventricular outflow tract left ventricular end-systolic pressure and left ventricular end-systolic dimension were fell from 170.6${\pm}$24.3 to 143.7${\pm}$27.1 mmHg and from 1.78${\pm}$0.4 to 1.76${\pm}$0.4 cm respectively and left ventricular posterior wall thickness was increased from 1.10${\pm}$0.2, to 1.27${\pm}$0.3cm but it was not statistically singificant whereas left ventricular end-systolic wall stress fell from 79.2${\pm}$24.9 to 57.1${\pm}$27.6 kdynes/cm2(p=0.018) in 7 patients. For one patient who underwent reoperation peak aortic gradient fell from 83.0 to 59.7 mmHg whereas left ventricular end-systolic wall stress increased from 67.2 to 97.0 kdynes/cm2 The intervals did not change significnatly. Conclusion ; We believe that probably some factors that are related to left ventricular geometry influenced the decreased left ventricular wall stress immediately after surgical correction of isolated congenital aortic stenosis. Left ventricular wall stress is a noninvasive measurement and can allow for more direct assesment than measuring peak aortic gradient particularly in consideration of the stress and oxygen consumption of the myocardium therefore we can conclude it is a useful measurement for postoperative assessment of congenital aortic stenosis.

  • PDF

金型의 모서리부 形狀이 熱應力分布에 미치는 影響 (The effect of corner shape in the casting mould on thermal stresses distribution)

  • 민수홍;구본권;김옥삼
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.567-574
    • /
    • 1991
  • In this study thermal stress generated in three ingot moulds(GC25) during the solidification process of aluminum were analyzed by the two-dimensional thermo-elasto-plastic theory. In temperature analysis, all of the three models are shown steep temperature rising each case in initial stage of cooling. In thermal stress analysis, all of three models took compressible stress on inside wall of the mould, and tensible along with on out side. Model 2 take place less compressible, tensible stress then model 1. But model 3. have similar as thermal stress as model 2. The analysis will made one possible to calculate an optimum mould shape whose thermal stress gradient becomes minimum.

표면 미세 가공된 구조체를 이용한 박막의 응력 측정 (Stress Measurement of films using surface micromachined test structures)

  • 이창승;정회환;노광수;이종현;유형준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.721-725
    • /
    • 1996
  • The microfabricated test structures were used in order to evaluate the stress characteristics in films. The test structures were fabricated using surface micromachining technique, including HF vapor phase etching as an effective release method. The fabricated structures were micro strain gauge, cantilever-type vernier gauge and bridge for stress measurement, and cantilever for stress gradient measurement. The strain was measures by observing the deformation of the structures occurred after release etching and the amount of deformation can be detected by micro vernier gauge, which has gauge resolution of 0.2${\mu}{\textrm}{m}$. The detection principles and the degree of precision for the measured strain were also discussed. The characteristics of residual stress in LPCVD polysilicon films were studied using these test structures. The stress gradient due to the stress variation through the film thickness was calculated by measuring the deflection at the cantilever free end.

  • PDF

와이어 방전 가공 시 발생되는 열응력 분포에 관한 유한요소법적 고찰 (A study on the Thermal Stress Distribution for Wire Electrical Discharge by Finite Element Method)

  • 반재삼;김승욱;김선진;조규재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.210-213
    • /
    • 2002
  • The Purpose of this study is to know temperature and thermal stress distribution in specimens during processing of WEDM. If it is constant to the cutting speed and the thickness of material, it is very important to the effect of temperature and the thermal stress distribution after cutting processing. This paper show the analysis result of the distribution of temperature and the residual stress along the direction of thickness before processing of WEDM and after when the cooling temperature is$20^{\circ}C$. The maximum temperature of edge of specimens is $1600^{\circ}C$. It has little temperature gradient in the depth which is 5mm away from edge of specimens. Equivalent residual stress is result in 180.7 MPa at maximum temperature.

  • PDF

2次元 垂直壁을 지니는 再附着 剝離 斷層 의 亂流構造 에 관한 硏究 (I) (Investigation on the Turbulence Structure of Reattaching Separated Shear Layer Past a Two-Dimensional Vetrical Fenc(I))

  • 김경천;정명균
    • 대한기계학회논문집
    • /
    • 제9권4호
    • /
    • pp.403-413
    • /
    • 1985
  • 본 논문에서는 수직벽 하류에 형성되는 박이 전단층의 발전과 재부착 그리고 재발전 경계층에 대해 평균 속도, 벽면의 압력 분포, 난류 강도, 레이놀즈 전단 압력 및 아직 수직벽에 대해서는 보고된바 없는 난류 떨림 속도 성분들의 3승곱 통계치를 측정하여 난류 구조의 변화를 분석하고 이를 수치적 계산 모델개발의 자 료로 제공하고자 함이 이 연구의 목적이다.

도브테일 그루브에 장착된 O-링시일의 접촉응력에 관한 연구 (Contact Stress Analysis of an O-ring Seal in a Dovetail Groove)

  • 김청균;황준태
    • Tribology and Lubricants
    • /
    • 제16권2호
    • /
    • pp.138-143
    • /
    • 2000
  • The sealing performance of an elastomeric O-ring seal with a temperature gradient has been analyzed for the contact stress behaviors that develop between the O-ring seal and the housing surfaces with which it comes into contact in the dovetail groove. The leakage of an O-ring seal will occur when the pressure differential across the seal just exceeds the initial peak contact stress. The contact stress behaviors that develop in compressed O-rings, in common case of restrained geometry (grooved), are investigated using the finite element method. The FE analysis includes material hyperelasticity and axisymmetry The computed FEM results show that the contact stress behaviors are related to a compression rate and a temperature gradient between the vacuum chamber with a dovetail groove and the contacting plate with a cooling jacket.

X방향의 선형함수구배인 재료에서 전파하는 균열의 동적응력확대계수 $K_{IIID}$ (Dynamic Stress Intensity Factor $K_{IIID}$ for a Propagating Crack in Liner Functionally Gradient Materials Along X Direction)

  • 이광호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.3-8
    • /
    • 2001
  • Dynamic stress intensity factors (DSIFs) are obtained when a crack propagates with constant velocity in rectangular functionally gradient materials (FGMs) under dynamic mode III load. To obtain the dynamic stress intensity factors, it is used the general stress and displacement fields of FGMs for propagating crack and the boundary collocation method (BCM). The stress intensity factors and energy release rates are the greatest in the increasing properties $(\xi>0)$, next constant properties $(\x=0)$ and decreasing properties $(\xi<0)$ under constant crack tip properties and crack tip speed.

  • PDF

Application the mechanism-based strain gradient plasticity theory to model the hot deformation behavior of functionally graded steels

  • Salavati, Hadi;Alizadeh, Yoness;Berto, Filippo
    • Structural Engineering and Mechanics
    • /
    • 제51권4호
    • /
    • pp.627-641
    • /
    • 2014
  • Functionally graded steels (FGSs) are a family of functionally graded materials (FGMs) consisting of ferrite (${\alpha}$), austenite (${\gamma}$), bainite (${\beta}$) and martensite (M) phases placed on each other in different configurations and produced via electroslag remelting (ESR). In this research, the flow stress of dual layer austenitic-martensitic functionally graded steels under hot deformation loading has been modeled considering the constitutive equations which describe the continuous effect of temperature and strain rate on the flow stress. The mechanism-based strain gradient plasticity theory is used here to determine the position of each layer considering the relationship between the hardness of the layer and the composite dislocation density profile. Then, the released energy of each layer under a specified loading condition (temperature and strain rate) is related to the dislocation density utilizing the mechanism-based strain gradient plasticity theory. The flow stress of the considered FGS is obtained by using the appropriate coefficients in the constitutive equations of each layer. Finally, the theoretical model is compared with the experimental results measured in the temperature range $1000-1200^{\circ}C$ and strain rate 0.01-1 s-1 and a sound agreement is found.

Nonlocal strain gradient-based vibration analysis of embedded curved porous piezoelectric nano-beams in thermal environment

  • Ebrahimi, Farzad;Daman, Mohsen;Jafari, Ali
    • Smart Structures and Systems
    • /
    • 제20권6호
    • /
    • pp.709-728
    • /
    • 2017
  • This disquisition proposes a nonlocal strain gradient beam theory for thermo-mechanical dynamic characteristics of embedded smart shear deformable curved piezoelectric nanobeams made of porous electro-elastic functionally graded materials by using an analytical method. Electro-elastic properties of embedded curved porous FG nanobeam are assumed to be temperature-dependent and vary through the thickness direction of beam according to the power-law which is modified to approximate material properties for even distributions of porosities. It is perceived that during manufacturing of functionally graded materials (FGMs) porosities and micro-voids can be occurred inside the material. Since variation of pores along the thickness direction influences the mechanical and physical properties, so in this study thermo-mechanical vibration analysis of curve FG piezoelectric nanobeam by considering the effect of these imperfections is performed. Nonlocal strain gradient elasticity theory is utilized to consider the size effects in which the stress for not only the nonlocal stress field but also the strain gradients stress field. The governing equations and related boundary condition of embedded smart curved porous FG nanobeam subjected to thermal and electric field are derived via the energy method based on Timoshenko beam theory. An analytical Navier solution procedure is utilized to achieve the natural frequencies of porous FG curved piezoelectric nanobeam resting on Winkler and Pasternak foundation. The results for simpler states are confirmed with known data in the literature. The effects of various parameters such as nonlocality parameter, electric voltage, coefficient of porosity, elastic foundation parameters, thermal effect, gradient index, strain gradient, elastic opening angle and slenderness ratio on the natural frequency of embedded curved FG porous piezoelectric nanobeam are successfully discussed. It is concluded that these parameters play important roles on the dynamic behavior of porous FG curved nanobeam. Presented numerical results can serve as benchmarks for future analyses of curve FG nanobeam with porosity phases.

복합재 연소관의 접착 길이에 따른 체결부의 구조해석 (A Study on the Structural Analysis of Joint Part in Accordance with Adhesive Length of a Composite Rocket Motor Case)

  • 전광우;신광복;황태경
    • 한국추진공학회지
    • /
    • 제16권3호
    • /
    • pp.90-96
    • /
    • 2012
  • 복합재 연소관의 접합 체결부 최적의 설계 길이를 결정하기 위해 접합부 길이변화에 따른 구조해석을 수행하였다. 이때, 접착 체결부의 길이는 50 mm에서 300 mm의 범위를 갖는다. 무응력 상태의 초기 접합부 길이대비 응력구배가 발생하는 않는 구간의 길이를 "응력구배 길이 비"로 정의하고 이를 접착 체결부 길이선정을 위한 평가기준으로 정의하였다. 구조해석 결과 접착 체결부의 길이가 200 mm 이상으로 증가할 경우 응력구배 길이 비의 증가가 서서히 나타남을 확인하였다. 이는, 접착 체결부에 적용되는 2,500 psi 내압에서 구조적 안전성을 확보하는 최적화된 접착 체결부의 길이가 200 mm임을 의미한다.