• 제목/요약/키워드: Stress drop

검색결과 372건 처리시간 0.045초

Beak Trimming Methods - Review -

  • Glatz, P.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권11호
    • /
    • pp.1619-1637
    • /
    • 2000
  • A review was undertaken to obtain information on the range of beak-trimming methods available or under development. Beak-trimming of commercial layer replacement pullets is a common yet critical management tool that can affect the performance for the life of the flock. The most obvious advantage of beak-trimming is a reduction in cannibalism although the extent of the reduction in cannibalism depends on the strain, season, and type of housing, flock health and other factors. Beak-trimming also improves feed conversion by reducing food wastage. A further advantage of beak-trimming is a reduction in the chronic stress associated with dominance interactions in the flock. Beak-trimming of birds at 7-10 days is favoured by Industry but research over last 10 years has shown that beak-trimming at day-old causes the least stress on birds and efforts are needed to encourage Industry to adopt the practice of beak-trimming birds at day-old. Proper beak-trimming can result in greatly improved layer performance but improper beak-trimming can ruin an other wise good flock of hens. Re-trimming is practiced in most flocks, although there are some flocks that only need one trimming. Given the continuing welfare scrutiny of using a hot blade to cut the beak, attempts have been made to develop more welfare friendly methods of beak-trimming. Despite the developments in design of hot blade beak-trimmers the process has remained largely unchanged. That is, a red-hot blade cuts and cauterises the beak. The variables in the process are blade temperature, cauterisation time, operator ability, severity of trimming, age of trimming, strain of bird and beak length. This method of beak-trimming is still overwhelmingly favoured in Industry and there appears to be no other alternative procedures that are more effective. Sharp secateurs have been used trim the upper beak of both layers and turkeys. Bleeding from the upper mandible ceases shortly after the operation, and despite the regrowth of the beak a reduction of cannibalism has been reported. Very few differences have been noted between behaviour and production of the hot blade and cold blade cut chickens. This method has not been used on a large scale in Industry. There are anecdotal reports of cannibalism outbreaks in birds with regrown beaks. A robotic beak-trimming machine was developed in France, which permitted simultaneous, automated beak-trimming and vaccination of day-old chicks of up to 4,500 chickens per hour. Use of the machine was not successful because if the chicks were not loaded correctly they could drop off the line, receive excessive beak-trimming or very light trimming. Robotic beak-trimming was not effective if there was a variation in the weight or size of chickens. Capsaicin can cause degeneration of sensory nerves in mammals and decreases the rate of beak regrowth by its action on the sensory nerves. Capsaicin is a cheap, non-toxic substance that can be readily applied at the time of less severe beak-trimming. It suffers the disadvantage of causing an extreme burning sensation in operators who come in contact with the substance during its application to the bird. Methods of applying the substance to minimise the risk to operators of coming in contact with capsaicin need to be explored. A method was reported which cuts the beaks with a laser beam in day-old chickens. No details were provided on the type of laser used, or the severity of beak-trimming, but by 16 weeks the beaks of laser trimmed birds resembled the untrimmed beaks, but without the bill tip. Feather pecking and cannibalism during the laying period were highest among the laser trimmed hens. Currently laser machines are available that are transportable and research to investigate the effectiveness of beak-trimming using ablasive and coagulative lasers used in human medicine should be explored. Liquid nitrogen was used to declaw emu toes but was not effective. There was regrowth of the claws and the time and cost involved in the procedure limit the potential of using this process to beak-trim birds.

저층수 배사관 내 유입된 사석 배출능력에 대한 연구 (A Experimental Study on Exclusion Ability of Riprap into Bypass Pipe)

  • 정석일;이승오
    • 대한토목학회논문집
    • /
    • 제37권1호
    • /
    • pp.239-246
    • /
    • 2017
  • 국내 중소하천의 횡단구조물인 보 또는 낙차공은 대부분 고정식 콘크리트 구조물이며, 저층수의 배제가 쉽지 않다. 횡단구조물로 인해 유사가 퇴적되며, 유사에 흡착한 오염물들이 그대로 하천의 바닥을 오염시키고 있다. 이에 저층수 및 퇴적유사에 대한 관심이 증가하고 있는 실정이며, 이러한 대안의 하나로 횡단구조물 상류와 하류를 하상 아래로 연결시키는 구조물로써, 보 상류 저층의 물 및 유사 배제를 목적으로 저층수배출관을 설치하는 방안이 있다. 그러나 사석이 유입되고, 배제 되지 않을 경우 효율성이 크게 저하될 가능성이 있다. 이에 본 연구에서는 저층수 배출관 내 사석을 배제할 수 있는 능력에 대한 연구를 수행하였다. 사석과 거동이 유사한 유사(sediment)의 한계조건(critical condition) 중 한계전단력(critical shear stress) 유도과정과 달랑베르의 원리(d'Alembert principle)를 응용하여 이동 중인 사석이 배제될 수 있는 조건(${\tau}_c{^*}$)을 유도하였다. 그러나 저층수 배출관 내 유입된 사석은 정지상태가 아닌 이동 중이므로, Lagrangian 기법을 활용하여 수리실험에서 도출된 유속으로 상대속도(relative velocity)를 제시하였다. 수리실험은 축척효과(scale effect)를 최소화하기 위해 폭이 5.0 m이고, 높이가 1.0 m인 광폭 개수로를 제작하였으며, 사용된 사석은 가공된 완전 구형을 사용하였다. 실험 결과 유속과 구형 입자 속도와의 비가 0.5~0.7 사이로 나타났으며, 이러한 결과를 유도된 식에 적용하여, 최종적으로 사석이 배제되는 조건을 도출하게 되었다. 구간은 입자레이놀즈수($Re_p$)와 무차원 한계 전단력(${\tau}_c{^*}$)에 따라 크게 3가지로 구분되었다. 배제 구간(exclusion section), 확률적 배제 구간(probabilistic exclusion section), 비배제 구간(no exclusion section)이다. 본 연구결과는 횡단구조물의 저층수 배출관 설계시 유용한 기초 정보를 제공할 수 있을 것이다.

일부 직업인들의 근골격계 자각증상과 강증진생활양식간의 연관성에 관한 연구 (A Study on the Relationship between Musculoskeletal Symptoms and Health Promoting Life Style among Some Workers)

  • 강홍구;이은경;전선영;김상덕;정재열;이영길;장두섭;송용선;이기남
    • 대한예방한의학회지
    • /
    • 제5권2호
    • /
    • pp.40-68
    • /
    • 2001
  • In this study, grade of subjective symptom appealed by laborer of Jeollabuk-do was evaluated using questionary regarding factor made effect on musculoskeletal disease and in addition, studied relationship with health promotion life style of them. Based on the result, relationship of general characteristics of musculoskeletal subjective symptom and life-style of the subjects was concluded as below. 1. General characteristics of study subjects were as following. Ratio of male was higher as 57.7% of male and 42.2% female and age distribution was 5.1% of 20s, 34.99% of 30s, 36.3% of 40s and 23.7% of 50s and therefore, $30{\sim}40$ aged groups showed highest ratio. Most subjects (74.9%) was married status and in case of education level, high-school graduate and dropout (23.3%) and over-college graduate (46.8%) showed highest distribution. $1{\sim}2$ Mil. KRW (29.5%) and $2{\sim}2.99$ Mil. KRW (21.2%) is the main income distribution and however there was high ratio of non-reply (29.0%). In case of employment period, $10{\sim}14$ years (15.3%) and over 15 years (29.6%) showed highest ratio and there were many non-reply (39.4%) and in addition, 67.6% replied as own house and 14.3% as lease on deposit base in question of residence type. 2. Subjects showed high ratio of subjective symptom appeal of 62.79% and many cases (50.23%) appealed 1 or 2 symptoms. Symptom by body region was 29.8% (waist), 27% (shoulder), 21.2% (knee), 15.5% (neck), 9.5% (ankle), 8.1% (wrist) and 5.0% (elbow) in order. In case of relationship with general characteristics, female comparing with male, non-residence of own house, subjects with lower education level and employment period of $10{\sim}14$ years showed higher appeal rate and kind of symptoms than others. Therefore, it was concluded that rate of musculoskeletal symptom appeal have close relationship with gender, level of living, education level, age and employment period. 3. In case of severe pain of upper body except waist and ankle, it was appealed in both or right side and it means that upper body pain is originated from right side and right region pain is transited to both region pain. In addition, there was 39.41% of non-reply to existence of right-left region pain and therefore, it was evaluated that, in may cases, there was no awareness of their own symptom condition even on subjective symptom. 4. Degree of pain was, as pain over middle level, evaluated as 2.79 on full mark of 4.0 and in order of waist (2.97), ankle (2.83), knee (2.82), wrist (2.82), neck (2.79), shoulder (2.70) and elbow (2.62). In addition, 71.97% appealed $2{\sim}3$ cases for the latest 1 week. Owing to subjective symptom, 54.95% drop into hospital or pharmacy, 10.32% made temporary retirement or absence, 7.99% transferred into more comfortable duty and $39.4{\sim}54%$ experienced one or more managing mentioned above. 5. Fulfillment of health promotion life style of subjects was evaluated on full mark of 4.0 and total score was 2.63. Average mark of each area was personal relationship (3.05), self-realization (2.92), stress management (2.63), health control (2.48), physical exercise (2.19) and nutrition management (2.19) and personal relationship was highest and physical exercise and nutrition management were lowest. As general characteristics influencing health promotion life style, gender, residence style and employment period showed significant difference. Male showed higher mark than female and showed higher mark in order of own house, others, lease on deposit base, monthly rent. Subjects with longer employment period showed higher mark with significant difference. 6. Accounting of factor influencing each area of health promotion life style, self-realization showed significance in marriage status, income, residence style and education level and health control in age, residence style and employment period. Physical exercise showed significant difference in gender, age, residence style and employment period and nutrition in gender, age, residence style and employment period. Stress management showed significant difference in residence style and employment period and however not in personal relationship. 7. Health promotion life style relating with existence and kind of pain showed significant difference in all area except personal relationship area. In absence of pain, there was statistically significant high score in all area even in total health promotion life style and all area. Accounting of kind of pain, cases of $1{\sim}2$ kinds of pain and $5{\sim}6$ kinds of pain showed relatively high score and it was lower than mark of subject stated absence of pain. 8. Subjects appeal symptom were classified by symptom region and difference of total and each areas were evaluated. General area (p=0.002), self-realization (p=0.012), health management (p=0.023), physical exercise (p=0.028), nutrition management (p=0.028) and stress control (p=0.001) showed statistically significant difference and not in personal relationship area. Especially, elbow, shoulder and neck area marked high and group appealed pain of knee, arm and elbow, foot and ankle marked low. Based on those results, subjective symptom should be accounted seriously in diagnosis of occupational musculoskeletal disease of laborer and among subjective symptom, general characteristics of gender, age, condition of living, education level and employment period make effect. Generally subject appeal symptom marked lower than subject without symptom appeal and it means that life management of subject appealing musculoskeletal pain make important role in management and treatment of occupational musculoskeletal disease.

  • PDF

1999년 경주 인근에서 3차례 발생한 지진들의 지진원 특성 분석 (Analysis on the source characteristics of three earthquakes nearby the Gyeongju area of the South Korea in 1999)

  • 최호선;심택모
    • 지질공학
    • /
    • 제19권4호
    • /
    • pp.509-515
    • /
    • 2009
  • 1999년 경상북도 경주 인근에서 지역규모($M_L$) 3.0 이상의 지진이 3차례(4월 24일, 6월 2일, 9월 12일)에 걸쳐 발생하였다. 진앙의 위치를 재결정한 결과 이 지진들의 진앙 사이 거리는 반경 1 km 내에 포함된다. 파형역산을 수행하여 6월 2일 지진의 발진기구를 분석하였으며, 나머지 지진들은 P파와 S파의 초동극성 및 진폭비를 이용하여 발진기구를 분석하였다. 6월 2일 및 9월 12일 지진은 단층면해가 서로 비슷하고, 4월 24일 지진은 상기 지진들의 단층면해를 포함하나 그 분포 범위가 상대적으로 넓다. 이 지진들의 발진기구는 공통적으로 약간의 정단층 성분을 포함한 주향이동단층의 특성을 보이며, P축의 방향은 동북동-서남서 방향으로 한반도 주응력 방향에 대한 이전 연구결과와 부합한다. 진앙 사이의 거리, 지진파형의 유사성, 지진들을 공통으로 기록한 지진관측소 지진자료 극성의 동일성, 발진기구의 유사성 등을 고려했을 때, 이 지진들은 동일한 단층에서 발생했을 것으로 1999년 경상북도 경주 인근에서 지역규모($M_L$) 3.0 이상의 지진이 3차례(4월 24일, 6월 2일, 9월 12일)에 걸쳐 발생하였다. 진앙의 위치를 재결정한 결과 이 지진들의 진앙 사이 거리는 반경 1 km 내에 포함된다. 파형역산을 수행하여 6월 2일 지진의 발진기구를 분석하였으며, 나머지 지진들은 P파와 S파의 초동극성 및 진폭비를 이용하여 발진기구를 분석하였다. 6월 2일 및 9월 12일 지진은 단층면해가 서로 비슷하고, 4월 24일 지진은 상기 지진들의 단층면해를 포함하나 그 분포 범위가 상대적으로 넓다. 이 지진들의 발진기구는 공통적으로 약간의 정단층 성분을 포함한 주향이동단층의 특성을 보이며, P축의 방향은 동북동-서남서 방향으로 한반도 주응력 방향에 대한 이전 연구결과와 부합한다. 진앙 사이의 거리, 지진파형의 유사성, 지진들을 공통으로 기록한 지진관측소 지진자료 극성의 동일성, 발진기구의 유사성 등을 고려했을 때, 이 지진들은 동일한 단층에서 발생했을 것으로 추정된다. 파형역산을 수행한 결과 6월 2일 지진의 지진모멘트는 $3.9\;{\times}\;10^{14}N{\cdot}m$로 계산되었으며, 이 값은 모멘트규모 3.7에 해당한다. 스펙트럼 분석을 통해 계산된 모멘트규모는 3.8로, 파형역산에 의한 모멘트규모와 비슷하다. 평균 응력강하는 7.5 MPa로 추정되었다. 3개 지진들을 공통으로 기록한 단일 지진관측소의 스펙트럼을 서로 비교한 결과 4월 24일 및 9월 12일 지진의 모멘트규모는 각각 3.2, 3.4로 추정되었다.

전기저항식 워터마크센서기반 소형 관수장치의 토양 수분퍼텐셜 자동제어 효용성 평가 (Feasibility Test on Automatic Control of Soil Water Potential Using a Portable Irrigation Controller with an Electrical Resistance-based Watermark Sensor)

  • 김학진;노미영;이동훈;전상호;허승오;최진용;정선옥;이중용
    • 생물환경조절학회지
    • /
    • 제20권2호
    • /
    • pp.93-100
    • /
    • 2011
  • 본 연구에서는 국내의 시설 내 작물재배에 적합한 자동관수 기술을 개발하기 위한 첫 단계로 전기저항의 변화원리를 이용하는 워터마크 센서를 장착한 소형 컨트롤러를 작물재배에 활용하여 자동관수기술의 효용성을 구명하고자 하였다. 이를 위해 비닐하우스 내에 다른 토성을 갖는 토양을 격리베드에 인공적으로 조성한 후 토마토를 정식하여 수분퍼텐셜을 -20kPa 수준으로 자동으로 조절하면서 재배하였다. 점적관수에 따른 토양 내 깊이별 수분변화는 Sentek 축전형 수분센서를 이용하여 측정하였다. 워터마크센서를 이용한 수분퍼텐셜 제어성능은 (-)20kPa 수준부근에서 유지되지 않고 반복적으로 0~(-)20kPa 대역에서 높은 변화 값을 나타내어 안정적이지 못한 것으로 나타났다. 특히, 물 공급은 관수시마다 약 50~60분 비교적 긴 시간동안 진행되어 수분공급이 과잉되는 문제가 나타났으며 건조시에도 수분퍼텐셜의 변화가 계단응답 반응의 형태로 변하는 불량한 측정해상도를 나타내었다. 이러한 문제는 워터마크센서의 토양과 전극 접촉형태가 다공컵식 수분장력계에 비해 수분값에 연속적으로 반응할 수 없는 구조이기 때문인 것으로 판단하였다. 자동관수에 따른 토양종류별 수분변화는 그 기울기가 토성별로 서로 달랐으며 양질사토의 경우 수분함량의 변화정도가 가장 높았다. 수분함량의 변화속도는 낮과 밤의 경우 시간에 따른 변화율이 달라서 변곡선의 형태를 나타내었다. 이러한 이유는 낮과 밤의 일교차와 태양광 유무에 의하여 수분증발량 차이가 발생하였기 때문인 것으로 판단하였다. 직물에서 20cm 떨어진 지점의 깊이별 수분함량은 작물에 인접한 위치와 비교하였을 때 세가지 토양 모두 관수에 의한 변화정도는 미미하여 직물에 인접한 곳만 수분공급이 효율적으로 이루어지는 것을 확인하였다. 추후 연구에서 양질사토 베드에서 관찰된 토마토 생육 불량 문제 개선과 관수멈춤 시간을 적용하여 물공급의 과잉 문제를 해결하는 보완실험이 요구되었다.

흉통 환자에서의 정서, 자존감 및 삶의 질에 대한 예비 연구 (A Preliminary Study on Emotion, Self-Esteem and Quality of Life in the Patients with Chest Pain)

  • 박숙현;제영묘;이대수;장세헌;최진혁;이한철
    • 정신신체의학
    • /
    • 제20권2호
    • /
    • pp.120-126
    • /
    • 2012
  • 연구목적 : 흉통을 호소하여 방문한 환자를 대상으로 우울, 불안, 자존감, 그리고 삶의 질 을 조사하고, 전형적 흉통과 비전형적 흉통에 따른 차이를 비교하였다. 방 법 : 39명의 흉통 환자와 40명의 대조군을 대상으로 하였으며, 순환기 내과 전문의의 문진과 심장 전산화 단층촬영, 답차운동부하검사, 관상동맥조영술 등을 시행하여 전형적 흉통과 비전형적 흉통을 감별하였다. 우울, 불안, 자존감, 그리고 삶의 질을 평가하기 위해 BDI(Beck's Depression scale), STAI(State trait anxiety inven-tory), RSES(Rosenberg Self-esteem Scale), SBQOL(SmithKlein Beecham Quality of Life Scale)를 적용하였다. 결 과 : 심질환의 위험인자는 가족력을 제외하고는 전형적 흉통군, 비전형적 흉통군, 그리고 대조군 간에 차이가 없었다. 우울은 대조군에 비해 두 가지 흉통군 모두에 더 높았으나 흉통군 간에는 차이가 없었다. 불안은 대조군에 비해 두 가지 흉통군 모두에서 더 높았고, 전형적 흉통군에 비해 비전형적 흉통군에서 더 높았다. 자존감과 삶의 질은 대조군과 전형적 흉통군에 비해 비전형적 흉통군에서 더 낮았다. 결 론 : 흉통환자에서 불안과 우울에 대한 평가와 개입이 필요하며, 특히 비전형적 흉통환자에서는 자존감과 삶의 질 저하에 대한 접근도 병행이 되어야 함을 시사한다.

  • PDF

한반도 남동부 지진의 지각매질 특성 및 지진원 특성 변수 연구 (Analysis of the Characteristics of the Seismic source and the Wave Propagation Parameters in the region of the Southeastern Korean Peninsula)

  • 김준경;강익범
    • 한국방재학회 논문집
    • /
    • 제2권1호
    • /
    • pp.135-141
    • /
    • 2002
  • 내진설계에 이용되는 지반진동과 관련된 주요 입력자료는 지진재해도 및 지반 응답스펙트럼 등이 있고 이러한 지진재해도 및 지반 응답스펙트럼을 평가하기 위하여 지역특성에 고유한 감쇠식이 필수적이다. 지역특성에 적합한 지반진동 감쇠식의 계수를 결정하기 위해 지진원 변수 및 지진파 전달특성 변수가 반드시 필요하고 본 논문에서는 지진원 변수 및 지진파 전달특성 변수를 평가하였다. 지진원 변수 및 지진파 전달특성 변수는 관측 지반 지진동에 대해 비선형적인 지배방정식을 이루고 있는 모델을 이용하였다. 이러한 비선형 지배방정식에 대한 수치해석 알고리즘을 통하여 지진원 변수 및 지진파 전달특성 변수 전체를 동시에 구하였다. 지반진동 자료는 주로 한반도 동남부 지역에서 발생하여 경상분지 주변 관측망에서 관측된 지반진동 자료를 이용하였다. 분석결과에 의하면 3개 지진원의 모멘트 지진규모(Mw)는 각각 2.9, 3.1 및 3.2로 분석되었다. 또한 3개 지진원의 코너 주파수는 각각 8.2, 6.9 및 8.3 Hz로 분석되었다. 그리고 지각 심부의 비탄성 감쇠율(Qo) 및 주파수 지수값 (${\eta}$)은 약 211 및 0.63으로 평가되었다. 지각 천부의 비탄성 감쇠율(${\kappa}$)은 각각의 관측소에서 약 0.02에서 약 0.06의 범위의 값을 가지고 있는 것으로 평가하였다. 결론적으로 하부지각 및 상부 지각의 비탄성 감쇠율 값을 미국 중동부와 서부와 비교할 경우 미국의 서부지역과 유사한 값을 보여주었다. 또한 지진원의 특성도 응력강하값 만을 고려한다면 역시 미국의 서부지역과 유사한 값을 보여주었다.TEX>의 범위로서 관측치와 거의 일치하였다. 그리고 분석유역의 양수 전의 모의발생분석 결과를 이용하여 지하등수두분포와 유속벡터를 산정한 결과 지하수 유동분포는 높은오름과 문석이오름 등에서 월랑봉, 용눈이오름 및 손자봉 등 각 방향으로 고르게 유출되고 있는 것으로 분석되었다. 이러한 분석결과는 MODFLOW모델과 비교할 때 일치된 결과를 나타내었다.기 등 벼 생육의 질적인 변화를 보이는 시기에 따라 나누어 분석하는 것이 변화추이를 더 잘 설명하는 것으로 나타났다. 모든 군에서 법랑질에 대한 광중합 복합레진의 미세전단 결합강도는 화학중합 복합레진보다 통계학적으로 높게 나타났다 (p < 0.05). 4. 모든 접착제와 법랑질 계면은 긴밀한 접합을 나타내어 화학중합 복합레진과 접착제 간에 비적합성이 나타나지 않았다.이를 나타내었다. (F = 49.705, p = 0.000) 3. B-IM군의 Ra 증감율은 F 군에 비해 210.72%감소되었으며, B-8 군과 B-15군의 Ra 증감율은 B-IM군에 비해 각각 35.49%와 51.35% 증가되었다. 4. FE-SEM 관찰에서 B-IM 군은 매우 평활한 복합레진 표면을 나타내었고, B-8 군은 전체적으로 평활한 복합레진 표면을 보였지만 표면에 수직으로 아주 얕은 흠집을 나타내었다. B-15 군은 복합레진 표면의 중앙에서 B-8군보다 더 넓고 불규칙한 수직의 흠집을 나타내었고, B-18군은 복합레진 표면 전체에 넓은 흠집을 나타내었다.교적 낮은 농도의 영양염류를 가지고 있고, 많은 처리수량을 요구하는 부영양화된 저수지의 수질개선을 위해서는 높은 수리학적 부하조건에서 시간당 정화량을 늘리는 관리방법이

국내 연구 동향 분석을 통한 포장분야에서 유한요소해석의 적용 방향에 관한 고찰 (A Study on the Application Direction of Finite Element Analysis in the Field of Packaging through Research Trend Analysis in Korea)

  • 이학래;전규배;고의석;심원철;강욱건;김재능
    • 한국포장학회지
    • /
    • 제23권3호
    • /
    • pp.191-200
    • /
    • 2017
  • 적정포장설계는 포장 원자재 사용량 및 폐기물 발생량뿐만 아니라 재료비 및 물류비 절감이 가능하여 포장재의 환경성과 경제성을 모두 충족시킨다. 유한요소해석은 구조해석, 열전달, 유체운동, 전자기 등 다양한 분야에 유용한 도구로 적용되고 있지만, 포장분야에서는 그 적용이 미비하다. 이에 따라 포장분야에 유한요소해석 적용은 컴퓨터 시뮬레이션으로 포장 설계가 가능하기 때문에 향후 연구에 있어 비용과 시간 절약이 가능하며 적정포장설계를 통해 포장 폐기물과 물류비 절감이 가능할 것으로 판단된다. 따라서 본 연구에서는 향후 포장분야에서 유한요소해석(FEM) 프로그램을 활용한 연구 설계에 도움이 되고자 하는 목적으로 국내에서 발표된 유한요소해석 관련 논문을 조사하였다. 1991년부터 2017년까지의 국내 학술지 및 학위논문에 게재된 유한요소해석 관련 논문 중 포장과 직접적인 연관성이 있다고 판단된 32편의 논문을 분석하여 연구의 동향을 살펴보았다. 그 결과 각 논문을 사용한 연구주제 및 내용, 유한요소해석 프로그램, 해석방법 등으로 분석하고 향후 포장분야에 활용할 수 있는 방향에 대하여 제시하였다. 포장 영역에 유한요소해석의 적용은 포장재에 가해지는 응력 및 진동해석을 통해 구조변경 및 두께 감량을 가능하게 하고 이에 따라 기계적 강도 향상 및 포장소재 사용량 감소를 통해 적정포장설계로 원가 절감이 가능할 것으로 판단된다. 따라서 향후 포장 분야의 연구에 있어, 유한요소해석을 함께 병행한다면 경제적이고 합리적인 포장 설계를 할 수 있을 것으로 판단된다.

풍속과 초기 토양수분에 따른 평면형 바이오필터 내 토양수분 안정화 및 식물 생육반응 평가 (Evaluation for Soil Moisture Stabilization and Plant Growth Response in Horizontal Biofiltration System Depending on Wind Speed and Initial Soil Moisture)

  • 최봄;천만영;이창희
    • 한국자원식물학회지
    • /
    • 제27권5호
    • /
    • pp.546-555
    • /
    • 2014
  • 연구의 최종 목표는 실내의 공간과 특성에 따라 효율적으로 실내공기질을 향상시킬 수 있는 식물 녹화와 바이오필터를 통합한 시스템의 개발이다. 그러나 이러한 목표를 달성하기 위해서는 바이오필터 시스템의 적절한 공기정화량에 대한 용량 설계에 중요한 영향을 주는 일정한 압력손실량과 토양수분 함량과 같은 여러 가지 요구사항들이 충족되어야 한다. 따라서 본 기초 연구는 바이오필터의 토양 내 균일한 분포를 갖는 토양수분 함량과 압력손실량을 유지하고 정상적인 식물 생장 특히 바람에 의한 근권부 스트레스를 받지 않도록 풍속을 적절히 조절하고, 바이오필터 내 초기 토양수분 함량이 일정하게 유지되어 안정성을 확보하기 위해 수행되었다. 본 실험에서는 평면형 바이오필터 모델을 설계하여 제작하고 세 가지 풍속(1, 2, $3cm{\cdot}sec^{-1}$)에 따른 바이오필터의 공기정화량, 공기체류시간, 기액비를 산출하였다. 또한 세가지 풍속에 따라 바이오필터 내 토양층을 통과하여 배출된 가습공기의 상대습도, 압력손실량, 토양수분 함량을 측정하고, 이 바이오필터 내에서 자란 상추와 더 피고사리의 생육을 평가하였다. 풍속 실험의 결과, 풍속 $3cm{\cdot}sec^{-1}$가 상대습도, 토양수분 함량, 식물생육을 유지하기에 가장 적절하였다. 따라서 다음 실험에서는 풍속을 $3cm{\cdot}sec^{-1}$로 고정하고 두 가지 수준의 초기 토양수분 함량(저수준 18.5%, 고수준 28.7%) 조건에서 바이오필터를 가동한 처리구와 바이오필터를 가동하지 않은 대조구(초기 토양수분 함량 29.7%)를 설정하고, 바이오필터 내 토양층을 통과하여 배출된 가습공기의 상대습도, 압력손실량, 토양수분 함량과 바이오필터 내에서 자란 상록넉줄고사리의 생육을 평가하였다. 이 실험 결과는 첫 번째 실험 결과와 유사하였으며 상대습도, 토양수분 함량, 압력손실량이 일정한 수준을 유지하였다. 또한 세 가지 초기 토양수분 함량에 따른 상록넉줄고사리의 생육도 유의성 있는 차이를 나타내지 않았다. 그러나 두 가지의 바이오필터 처리구는 대조구에 비해 건물중이 다소 증가된 것을 알 수 있었다. 따라서 주요 물리적 요소인 토양수분 함량과 압력손실량을 유지할 수 있는 본 바이오필터 시스템의 안정성은 가까운 미래에 보다 발전된 일체형 바이오필터 모델 설계에 적용될 수 있을 것으로 판단된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF