• Title/Summary/Keyword: Stress ECG

Search Result 82, Processing Time 0.023 seconds

A Study on the Heart Rate Variability for Improvement of AR / VR Service (AR/VR 서비스 향상을 위한 심박 변이도 연구)

  • Park, Hyun-Moon;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.191-198
    • /
    • 2020
  • In this study, we proposed a real-time ECG analytical method for predicting stress and dangerous heart condition using the ECG signal in playing AR/VR device. A real-time diagnosis is used as R-R interval based HRV(:Heart rate variability), BPM(:Beats Per Minitue) and autonomic nervous research with through mapping method of two-dimensional planes. The ECG data were analyzed every 5 minutes and derived from autonomic nervous system diagnosis.

Multidimensional Adaptive Noise Cancellation of Stress ECG Signal

  • Gautam, Alka;Lee, Young-Dong;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.285-288
    • /
    • 2008
  • In ubiquitous computing environment the biological signal ECG (Electrocardiogram signal) is usually recorded with noise components. Adaptive interference (or noise) canceller do adaptive filtering of the noise reference input to maximally match and subtract out noise or interference from the primary (signal plus noise) input thereby adaptively eliminate unwanted interference from the ECG signal. Measured Stress ECG (or exercise ECG signal) signal have three major noisy component like baseline wander noise, motion artifact noise and EMG (Electro-mayo-cardiogram) noise. These noises are not only distorted signal but also root of incorrect diagnosis while ECG data are analyzed. Motion artifact and EMG noises behave like wide band spectrum signals, and they considerably do overlapping with the ECG spectrum. Here the multidimensional adaptive method used for filtering which is more effective to improve signal to noise ratio.

  • PDF

The Assessment of Dynamic Mental Stress with Wearable Heart Activity Monitoring System (착용형 심장활동 모니터링 시스템을 활용한 정신적 스트레스 평가)

  • Kim, Kyeong-Seop;Shin, Seung-Won;Lee, Jeong-Whan;Choi, Hee-Jung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1109-1115
    • /
    • 2008
  • In the ubiquitous health monitoring environments, it is quite important not only to evaluate the physiological health condition but also mental stress condition. In order to achieve this goal, a heart activity monitoring system utilizing a wearable bipolar electrode is devised and the heart rate variability(HRV) is extracted and interpreted in both frequency and time feature domains. Consequently, to evaluate the emotional stress condition of the subjects, a stress-induced experimental protocol was applied to healthy subjects and the time and frequency features of heart activity were analyzed in terms of the ratio of low frequency components v.s., high frequency components and the relevant the moving average distributions compromising the successive RR peaks intervals in the ambulatory ECG measurement system.

EMG Signal Elimination Using Enhanced SVD Filter in Multi-Lead ECG (향상된 SVD 필터를 이용한 Multi-lead ECG에서의 EMG 신호 제거)

  • Park, Kwang-Li;Park, Se-Jin;Choi, Ho-Sun;Jeong, Kee-Sam;Lee, Kyoung-Joung;Yoon, Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.6
    • /
    • pp.302-308
    • /
    • 2001
  • SVD(Singular Value Decomposition) filter for the suppression of EMG in multi-lead stress ECG is studied. SVD filter consists of two parts. In the first part, the basis vectors were chosen from the averaged singular vectors obtained from the decomposed noise-free ECG. The singular vector is computed from the stress ECG and is compared itself with basis vectors to know whether the noise exist in stress ECG. In the second part, the existing elimination method is used, when one(or two) channels is(or are) contaminated by noise. But the proposed enhanced SVD filter is used in case of having the noise in the many channels. During signal decomposition and reconstruction, the noise-free channel or the least noisy channel have the weight of 1, the next less noisy channel has the weight of 0.8. In this way, every channel was weighted by decreased of 0.2 in proportion to the amount of the added noise. For the evaluation of the proposed enhanced SVD filter, we compared the SNR computed by the enhanced SVD filter with the standard average filter for the noise-free signal added with artificial noise and the patient data. The proposed SVD filter showed better in the SNR than the standard average filter. In conclusion, we could find that the enhanced SVD filter is more proper in processing multi-lead stress ECG.

  • PDF

A Study on the Automatic Diagnosis of ECG

  • Jeong, Gu-Young;Yu, Kee-Ho;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.55.4-55
    • /
    • 2001
  • Analyzing the ECG signal, we can find heart disease. Myocardial ischemia is a disorder of cardiac function caused by insufficient blood flow to the muscle tissue of the heart. Myocardial ischemia is inscribed on ST-segment of the ECG during and after patient takes exercise or is under stress, but after long time past, the ECG pattern is return to steady state. Therefore, it is necessary to monitor and analyze the ECG signal continuously for patient or aged people. Our primary purpose is the detection of temporary change of the ST-segment of ECG automatically. In the signal processing, the wavelet transform decomposes the ECG signal into high and low frequency components using wavelet function. Recomposing the high frequency bands including QRS complex, we can detect QRS complex more easily ...

  • PDF

Automated detection of panic disorder based on multimodal physiological signals using machine learning

  • Eun Hye Jang;Kwan Woo Choi;Ah Young Kim;Han Young Yu;Hong Jin Jeon;Sangwon Byun
    • ETRI Journal
    • /
    • v.45 no.1
    • /
    • pp.105-118
    • /
    • 2023
  • We tested the feasibility of automated discrimination of patients with panic disorder (PD) from healthy controls (HCs) based on multimodal physiological responses using machine learning. Electrocardiogram (ECG), electrodermal activity (EDA), respiration (RESP), and peripheral temperature (PT) of the participants were measured during three experimental phases: rest, stress, and recovery. Eleven physiological features were extracted from each phase and used as input data. Logistic regression (LoR), k-nearest neighbor (KNN), support vector machine (SVM), random forest (RF), and multilayer perceptron (MLP) algorithms were implemented with nested cross-validation. Linear regression analysis showed that ECG and PT features obtained in the stress and recovery phases were significant predictors of PD. We achieved the highest accuracy (75.61%) with MLP using all 33 features. With the exception of MLP, applying the significant predictors led to a higher accuracy than using 24 ECG features. These results suggest that combining multimodal physiological signals measured during various states of autonomic arousal has the potential to differentiate patients with PD from HCs.

A Study on a Stress Measurement Algorithm Based on ECG Analysis of NUI-applied Tangible Game Users (NUI가 적용된 체감형 게임의 사용자 심전도 분석에 의한 스트레스 측정 알고리즘 연구)

  • Lee, Hyun-Ju;Shin, Dong-Il;Shin, Dong-Kyoo
    • Journal of Korea Game Society
    • /
    • v.13 no.5
    • /
    • pp.73-80
    • /
    • 2013
  • NUI(Natural User Interface) allows users to directly interact with surrounding digital devices using their voices or body motions without additional input/output interface devices. Our study has been carried out on human users who play a tangible game with body motions in the NUI-applied smart space. ECG was measured for 60 seconds duration before and after playing the game to determine user stress levels, and the measured signals were analyzed through an improved Random Forest algorithm. In order to experiment by a supervised learning, users additionally input whether or not the user felt stress. Moreover, the improved algorithm showed 1.04% higher accuracy than existing algorithm.

A Study on the assessment of stress using Wireless ECG (무선 심전도측정을 통한 스트레스 평가에 관한 연구)

  • Lim, Chae-Young;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2011
  • In this paper, daily life stress monitoring system is proposed. The proposed wireless ECG module, reducing the noise and increasing the size of signal, amplification circuit was designed for. Using HRV(Heart Rate Variability), extracted by measuring R-wave, stress diagnostic algorithms to assess the stress of human emotion were developed. For monitoring the activities, the proposed system is consist of small rectangular size for portable and by simple measurement it is possible to measure at any time. Through experiments, the proposed approach to represent user's stress level can be confirmed. Through that, it can see appropriate structure to obtain R-wave for stress assess as well as high resemblance to the clinical electrocardiogram. In this paper, performed experiments was developed nonrestraint measuring and wearable wireless biometric scanner that is able to monitor the heart's electrical activity of everyday life.Using this, the algorithm system, that is able to assess stress index through time-domain and frequency-domain analysis of the front and the rear of performing stress load protocol, was developed,

Basic Study for Stress Analysis Using an Unconstrained BCG Monitoring System (무구속 심탄도 모니터링 시스템을 이용한 스트레스 분석 기초연구)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.118-123
    • /
    • 2011
  • Heart related diseases mainly caused by heavy work load and increasing stress in human daily life. Therefore, researches on mobile healthcare monitoring for daily life has been carried out. Notably, wearable healthcare monitoring system which has least restriction has been tried to provide an emergency alert of abnormal heart rate. In this study, we developed chair type unconstrained BCG measurement system which able to perform continuous heart status monitoring at the office and daily life in the unconstrained way. Furthermore, adaptive threshold is used to detect the heart rate from BCG signals. The HRV(heart rate variability) is calculated from heart rate interval. ECG signal measured using conventional method and BCG signal measured using unconstraint system are carried out simultaneously for the purpose of performance evaluation. From the comparison result, BCG signal shows a similar heart beat characteristic as ECG signal. This proves the possibility of practical implementation of unconstraint healthcare monitoring system. In addition, medical examination like valsalva maneuver is performed to observe the changes in HRV due to stress. By performing valsalva maneuver, heart is said to be placed under an artificial physical stress condition. Under this artificial physical stress condition, the time and frequency domain of HRV parameters are evaluated.

Tea Flavonoids Induced Differentiation of Peripheral Blood-derived Mononuclear Cells into Peripheral Blood-derived Endothelial Progenitor Cells and Suppressed Intracellular Reactive Oxygen Species Level of Peripheral Blood-derived Endothelial Progenitor Cells

  • Widowati, Wahyu;Wijaya, Laura;Laksmitawati, Dian Ratih;Widyanto, Rahma Micho;Erawijantari, Pande Putu;Fauziah, Nurul;Bachtiar, Indra;Sandra, Ferry
    • Natural Product Sciences
    • /
    • v.22 no.2
    • /
    • pp.87-92
    • /
    • 2016
  • Endothelial dysfunction in atherosclerosis is associated with increasing oxidative stress that could be reversed by antioxidant. Therefore epigallocatechin gallate (EGCG), epicatechin gallate (ECG), epigallocatechin (EGC) and catechin (C) of tea flavonoids were investigated for their roles in regenerating endothelial cell. Peripheral blood mononuclear cells (PB-MNCs) were isolated, plated and cultured in medium with/without treatment of EGCG, ECG, EGC and C. Results showed that among all EGCG, ECG, EGC and C concentrations tested, $12.5{\mu}mol/L$ was not cytotoxic for peripheral blood-derived endothelial progenitor cells (PB-EPCs). Treatment of EGCG, ECG, EGC or C increased the percentages of CD34, CD133, VEGFR-2 expressions and suppressed hydrogen peroxide-induced percentages of reactive oxygen species (ROS) level in PB-EPCs. Taken together, our current results showed that EGCG, ECG, EGC or C of tea flavonoids could induce differentiation of PB-MNCs into PB-EPCs as well as protect PB-EPCs from oxidative damage by suppresing the intracellular ROS levels.