• Title/Summary/Keyword: Stress Concentration factor

Search Result 371, Processing Time 0.035 seconds

Reaction of ferritin with hydrogen peroxide induces lipid peroxidation

  • Yoon, Hung-Hwan;Lee, Myeong-Seon;Kang, Jung-Hoon
    • BMB Reports
    • /
    • v.43 no.3
    • /
    • pp.219-224
    • /
    • 2010
  • Lipid peroxidation is known to be an important factor in the pathologies of many diseases associated with oxidative stress. We assessed the lipid peroxidation induced by the reaction of ferritin with $H_2O_2$. When linoleic acid micelles or phosphatidyl choline liposomes were incubated with ferritin and $H_2O_2$, lipid peroxidation increased in the presence of ferritin and $H_2O_2$ in a concentration-dependent manner. The hydroxyl radical scavengers, azide and thiourea, prevented lipid peroxidation induced by the ferritin/$H_2O_2$ system. The iron specific chelator desferoxamine also prevented ferritin/$H_2O_2$ systemmediated lipid peroxidation. These results demonstrate the possible role of iron in ferritin/$H_2O_2$ system-mediated lipid peroxidation. Carnosine is involved in many cellular defense processes, including free radical detoxification. In this study, carnosine, homocarnosine, and anserine were shown to significantly prevent ferritin/$H_2O_2$ system-mediated lipid peroxidation and also inhibited the free radical-generation activity of ferritin. These results indicated that carnosine and related compounds may prevent ferritin/$H_2O_2$ system-mediated lipid peroxidation via free radical scavenging.

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • Yoon, Hun-Ju;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Tamoxifen Suppresses Clusterin Level through Akt Inactivation and Proteasome Degradation in Human Prostate Cancer Cells

  • Shim, Jae-Ho;Choi, Chang-Su;Lee, Eun-Chang;Kim, Mie-Young;Chun, Young-Jin
    • Biomolecules & Therapeutics
    • /
    • v.17 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Clusterin is a heterodimeric sulfated glycoprotein and plays a role in many different types of cancer as a cell survival factor and helps cancerous cells to evade stress-induced apoptosis. To investigate whether the regulation of clusterin expression is involved in the mechanism of anticancer agent, we studied the effect of tamoxifen on clusterin expression in human prostate cancer PC-3 cells. Treatment of PC-3 cells with tamoxifen reduced cellular proliferation. Western blot analyses showed that treatment with tamoxifen suppressed clusterin expression in a concentration-dependent manner. Transfection with clusterin siRNA plasmid showed that clusterin is required for PC-3 cell survival. We found that tamoxifen resulted in a rapid decrease in the phosphorylation of Akt on Ser473 leading to prevent kinase activity. Expression of myristoylated Akt prevented tamoxifen-mediated clusterin downregulation. Interestingly, MG132, a wellknown proteasome inhibitor also recovered clusterin expression suppressed by tamoxifen. These data indicate that clusterin expression may be regulated by activation of Akt and ubiquitin-proteasome pathway plays an important role in tamoxifen-mediated clusterin suppression.

A Study on Accelerated Life Prediction Automation of Gas Welded Joint of STS301L (Plug and Ring Type) (STS301L 가스용접이음재의 가속수명예측 자동화에 관한 연구 (Plug and Ring Type))

  • Baek, Seung-Yeb;Sohn, Il-Seon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.1-8
    • /
    • 2011
  • Stainless steel sheets are widely used as the structure material for the railroad cars and the commercial vehicles. These kinds structures used stainless steel sheets are commonly fabricated by using the gas welding. Gas welding is very important and useful technology in fabrication of an railroad car and vehicles structure. However fatigue strength of the gas welded joints is considerably lower than parent metal due to stress concentration at the weldment, fatigue strength evaluation of gas welded joints are very important to evaluate the reliability and durability of railroad cars and to establish a criterion of long life fatigue design. In this paper, ${\Delta}-N_f$ curve were obtained by fatigue tests. Using these results, the accelerated life test (ALT) is conducted. From the experimental results, an acceleration model is derived and acceleration factors are estimated. So it is intended to obtain the useful information for the fatigue lifetime of plug and ring gas welded joints and data analysis by statistical reliability method, to save time and cost, and to develop optimum accelerated life prediction plans.

Detail-design Guidance for the Openings on the Web Structure Supporting the Deck (갑판지지 웨브 구조에서의 개구부 상세설계기준 정립)

  • Kim, Sung-Chan;Lee, Kyung-Seok;Song, Jae-Young;Kim, Kyung-Su
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.6
    • /
    • pp.612-618
    • /
    • 2007
  • There are a lot of openings, holes and slots in ship structural members. It is not easy to solve the troubles around the openings adequately at the detail design stage, because there are a lot of concerning locations. There are not also clear design rules of classification societies and it is not possible to apply direct calculation for all the concerning members. Therefore, it is necessary to set up simplified approach such as a standard or guidance in order to decide the opening design quickly. For this study, guidance and regulations of each classification and several companies were surveyed. Grillage analysis and the refined mesh method were used to evaluate the strength around hole considering boundary condition and more detailed member arrangement. As a result, the standard for opening design was established and verified.

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • 윤헌주;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Corrosive Characterisics of 12Cr Alloy Steel and Fatigue Characteristics of the Artificially Degraded 12Cr Alloy Steel (12Cr 합금강의 부식특성 및 인공열화된 12Cr합금강의 피로특성)

  • Jo, Sun-Young;Kim, Chul-Han;Bae, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.965-971
    • /
    • 2001
  • To estimate the reliability of 12Cr alloy steel, the material of turbine blade in the steam power plant, Its corrosion susceptibility and fatigue characteristics in NaCl and Na$_2$SO$_4$solution with the difference of concentration and temperature was investigated. The polarization tests recommended in ASTM G5 standard for corrosion susceptibility in the various corrosive solutions was estimated. It showed that the higher temperature, the faster corrosion rates and corrosion rates were the fastest in 3.5 wt.% NaCl and 1M Na$_2$SO$_4$solution. From these results, the degradation conditions were determined in distilled water, 3.5 wt.% NaCl and 1M Na$_2$SO$_4$solution at room temperature, 60$\^{C}$ and 90$\^{C}$ during 3, 6 and 9 months. Its surface had a few pits for long duration. But, it was not susceptible in sulfide and chloride condition of several temperatures. If the degraded 12Cr alloy steel and non-degraded one were compared with fatigue characteristics, Any differences were not found regardless of temperature and degradation period.

β-Carotene Production from Dunaliella salina Cultivated with Bicarbonate as Carbon Source

  • Xi, Yimei;Wang, Jinghan;Xue, Song;Chi, Zhanyou
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.6
    • /
    • pp.868-877
    • /
    • 2020
  • Bicarbonate has been considered as a better approach for supplying CO2 to microalgae cells microenvironments than gas bubbling owing to cost-effectiveness and easy operation. However, the β-carotene production was too low in Dunaliella salina cultivated with bicarbonate in previous studies. Also, the difference in photosynthetic efficiency between these two carbon sources (bicarbonate and CO2) has seldom been discussed. In this study, the culture conditions, including NaHCO3, Ca2+, Mg2+ and microelement concentrations, were optimized when bicarbonate was used as carbon source. Under optimized condition, a maximum biomass concentration of 0.71 g/l and corresponding β-carotene content of 4.76% were obtained, with β-carotene yield of 32.0 mg/l, much higher than previous studies with NaHCO3. Finally, these optimized conditions with bicarbonate were compared with CO2 bubbling by online monitoring. There was a notable difference in Fv/Fm value between cultivations with bicarbonate and CO2, but there was no difference in the Fv/Fm periodic changing patterns. This indicates that the high concentration of NaHCO3 used in this study served as a stress factor for β-carotene accumulation, although high productivity of biomass was still obtained.

Plasma Levels of Cytokines in Patients with Postpartum Depression (산후우울증 환자에서 혈장 Cytokine의 농도변화에 대한 전향적 연구)

  • Lee, Younjung;Kim, Yong-Ku;Kim, Kye-Hyun;Lee, Bun-Hee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.28 no.2
    • /
    • pp.177-184
    • /
    • 2020
  • Objectives : Postpartum depression is known to occur in 10-15% of mothers. The concentration of cytokine varies depending on stress, depression, pregnancy and general medical conditions. We hypothesized that the concentration of cytokines may be related to reproduction and childbirth, and that women with postpartum depression would show alterations in cytokines levels. Methods : A total of 104 pregnant women were selected as subjects, and 60 non-pregnant women were selected as normal controls. Symptoms of depression were evaluated in the pregnant study subjects using the diagnostic criteria outlined in the Edinburgh Postnatal Depression Scale (EPDS). The pregnant subjects were divided into three groups perinatal non-depression controls (n=61), postpartum depression-recovery (n=18), and postpartum depression (n=25). Results : The plasma concentration of TGF-β1, IGF-1 was higher in the pregnant group than in non-pregnant controls (TGF-β1 ; p<0.01, IGF-1 ; p=0.026). At 24 weeks of pregnancy and 6 weeks of delivery, there were no significant differences in the plasma concentration of TGF-β1, IGF-1, β-NGF, IL-2, IL-4, IL-6, IFN-γ, TNF-α between the three groups. There was no statistically significant difference in all three groups during the course of depression in pregnant women. Conclusions : This study found significant difference in plasma cytokines concentrations between non-pregnant controls and perinatal non-depression controls.

Two and Three-Dimensional Analysis Comparison of Nozzles due to Internal Pressure, Thermal Load and External Load (내부압력, 열하중 및 외부하중을 고려한 노즐의 2차원 및 3차원 해석 비교)

  • Yoon, Hyo-Sub;Kim, Jong-Min;Maeng, Cheol-Soo;Kim, Hyun-Min;Lee, Dae-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.283-291
    • /
    • 2015
  • In this paper, the two-dimensional(2D) and three-dimensional(3D) analyses have been performed in order to evaluate the structural integrities and compare 2D and 3D results for nozzles attached to cylindrical shells. Three nozzles, which are currently used in the nuclear power plant, are chosen to evaluate the structural integrities, and each nozzle is subjected to internal pressure, temperature variation and external loads. It is found that the 2D analysis for internal pressure should be performed with a factor of more than 1.5 or a stress concentration factor; 2D and 3D analysis results for temperature variation are almost similar to each other regardless of cladding; and the analysis results for external loads by WRC Bulletin 297 are more conservative than the 3D analysis results.