• Title/Summary/Keyword: Stress & strain measurement

Search Result 323, Processing Time 0.028 seconds

Measurement of Tensile Properties Dependent on the Small-Scaled Specimen Dimension for Evaluation of In-Service Materials Properties (사용재 물성 평가를 위한 미소 시험편 크기에 따른 인장 특성 평가)

  • Huh, Yong-Hak;Kim, Dong-Iei;Kim, Dong-Jin;Lee, Hae-Moo;Park, Jong-Seo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.30-34
    • /
    • 2008
  • To evaluate the mechanical properties of in-service materials, tensile properties measurement using small-scaled specimen has been carried out. Tensile testing specimens with various dimensions, including standard and sub-size specimen specified in ASTM and ISO and small-scaled specimen, were prepared. Tensile strain in small-scaled specimen was measured using micro-ESPI system set up in this study. This system was used in the specimen with the parallel length of 2 mm and in subsequently measuring the strain under tensile loading. From each type of tensile specimen, stress-strain curves were determined. The dimension effect of the tensile properties was investigated comparing the tensile results obtained from standard specimens and small-scaled specimens. It was shown that the tensile strength for the small-scaled specimen is lower by 15% than those for the standard specimen.

EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES (측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향)

  • Seo, Deog-Gyu;Min, Sun-Hong;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of instrument compliance on the polymerization shrinkage stress measurements of dental composites. The contraction strain and stress of composites during light curing were measured by a custom made stress-strain analyzer, which consisted of a displacement sensor, a cantilever load cell and a negative feedback mechanism. The instrument can measure the polymerization stress by two modes: with compliance mode in which the instrument compliance is allowed, or without compliance mode in which the instrument compliance is not allowed. A flowable (Filtek Flow: FF) and two universal hybrid (Z100: Z1 and Z250: Z2) composites were studied. A silane treated metal rod with a diameter of 3.0 mm was fixed at free end of the load cell, and other metal rod was fixed on the base plate. Composite of 1.0 mm thickness was placed between the two rods and light cured. The axial shrinkage strain and stress of the composite were recorded for 10 minutes during polymerization. and the tensile modulus of the materials was also determined with the instrument. The statistical analysis was conducted by ANOVA. paired t-test and Tukey's test (${\alpha}<0.05$). There were significant differences between the two measurement modes and among materials. With compliance mode, the contraction stress of FF was the highest: 3.11 (0.13). followed by Z1: 2.91 (0.10) and Z2: 1.94 (0.09) MPa. When the instrument compliance is not allowed, the contraction stress of Z1 was the highest: 17.08 (0.89), followed by FF: 10.11 (0.29) and Z2: 9.46 (1.63) MPa. The tensile modulus for Z1, Z2 and FF was 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa, respectively. With compliance mode. the measured stress correlated with the axial shrinkage strain of composite: while without compliance the elastic modulus of materials played a significant role in the stress measurement.

Indentation Damage of Porous Alumina Ceramice

  • Ha, Jang-Hoon;Lee, Chul-Seung;Kim, Jong-Ho;Kim, Do-Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.1
    • /
    • pp.19-23
    • /
    • 2004
  • The Hertzian indentation contact damage behavior of porous alumina with controlled pore shape was investigated by experiments. Porous alumina ceramics containing well-defined pore shape, size and distribution were prepared by incorporation of fugitive spherical starch. Porous alumina with isolated pore structure was prepared with porosity range up to 30%. The indentation stress-strain curves of porous alumina were constructed. Elastic modulus and yield stress can be obtained from the stress-strain relationship. Impulse excitation method for the measurement of elastic modulus was also conducted as well as Hertzian indentation and was confirmed as a useful tool to evaluate the elasticity of highly porous ceramics. Elastic modulus of the inter-connected pore structure is more sensitive to porosity than that of the isolated pore structure. When the specimen had isolated pore structure, higher yield point was obtained than it had inter-connected pore structure. This study proposed that the elastic modiulus of porous ceramics is strongly related to not only porosity, but also the structure of pore.

A study on stress-strain relation measurement for micro scale UV-curable polymer structure (UV-경화 폴리머 마이크로 구조물의 응력-변형률 관계 측정에 관한 연구)

  • Jeong S.J.;Kim J.H.;Lee H.J.;Park S.H.;Yang D.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.492-497
    • /
    • 2005
  • In this study, we propose an advanced nanoindentaion test, Nano Pillar Compression Test (NPCT) to measure a stress-strain relation for micro scale polymer structures. Firstly, FEM analysis is performed to research behavior of micro polymer pillars in several specimen aspect ratios and different friction conditions between specimen and tip. Based on the FEM results, micro scale UV-curable polymer pillars are fabricated on a substrate by Nano Stereo Lithography (NSL). To measure their mechanical properties, uniaxial compression test is performed using nanoindentation apparatus with flat-ended diamond tip. In addition, the dependency of compression properties on loading condition and specimen size are discussed.

  • PDF

Earthquake Response Analysis at Port Island during the 1995 Hyogoken-nanbu Earthquake(Japan) (일본 한신 대지진에 있어서의 포트 아일랜드의 지진응답해석)

  • 황성춘
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.477-484
    • /
    • 2000
  • Earthquake response analyses are conducted for the investigation of the ground shaking during the 1995 Hyogoken-nambu earthquake. Port Island a man made island with about 8{{{{ KAPPA m^2 }} area is chosen for this purpose Because earthquake measurement with vertical array was conducted there. Strain dependent characteristics of soil can be modeled well into Hardin-Drnevich Model. Four analyses are conducted : total stress analysis by equivalent linear method non-linear method. and two effective stress analyses. All analyses except equivalent linear analysis show fairy good agreement with observed record mainly because the non-linear behavior of Holocene clay layer has predominant effect on the behavior of fill, However detailed investigation show that effective stress analyses give much better prediction than total stress analyses.

  • PDF

AJM을 이용한 HDM에 의한 잔류응력 계측에 관한 연구 1

  • 이택순
    • Journal of Welding and Joining
    • /
    • v.6 no.3
    • /
    • pp.37-42
    • /
    • 1988
  • The Hole Drilling Method(HDM) is widely used to measure residual stresses in the welded structures. The purpose of this study is to evaluate the accuracy fo measuring residual stresses when drilling the hole by Air-abrasive Jet machine(AJM). Simulated residual stresses wre introduced by applying known stresses to steel bars. These known streses were then compared with measured stresses relaxed from hole drilling. the obtained results are summarized as follows; 1) It was possible to obtain well defined holes with the nozzle designed for this study. 2) If the hole shape is not cylindrical, critical may occur. 3) In the uniaxial strain field, the measurement error of the maximum principal stress was within .+-.10 percent. The orientation angle of the maximum principal stress was within 8.deg. from the given directioin. 4) meausrements were made varying hole depths. Little or no change of stresses occurs since holse were drilled more than the depth of the 0.6 times diameter. 5) The air-abrasive jet machining for drilling holse does not cause appreciable apparent stresses which si critical to measure residual stresses.

  • PDF

The Effect of Two Circular Holes Arrangement on the Stress Concentration Factor in a Semi-infinite Plate (양무한평판의 두 원공비렬이 응력집중에 미치는 영향)

  • 오세욱;박영철;김준영
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.110-119
    • /
    • 1990
  • This study is concerned about the stress concentration factor measurement by photoelastic method, for the case of two circular holes arrangement in 3mm semi-infinite plate under tensile load, the ratio of those two circular holes diameter, the ratio of distance apart from circular holes to breadth and the two holes arrangement angle with loading direction were varied. Besides, the measured stress concentration by photoelastic method around one circular hole was compared with that by strain-gage method.

  • PDF

A Study on the Predict of Residual Stress Using a Neural Network (신경회로망을 이용한 용접잔류응력 예측에 관한 연구)

  • 김일수;이연신;박창언;정영재;안영호
    • Proceedings of the KWS Conference
    • /
    • 2000.04a
    • /
    • pp.251-255
    • /
    • 2000
  • Recently, the improvement of computer capacities and artificial intelligence ware caused to employ for prediction of residual stresses and strength evaluation. There are a lot of researches regarding the measurement and prediction of residual stresses for weldment using a neural network in the advanced countries, but in our country, a neural network as a technical part, has only been used on the possibilities of employment for welding area. Furthermore, the relationship between residual stress and process parameters using a neural network was wholly lacking. Therefore development of a new technical method for the optimized process parameters on the reduction of residual stress and applyment of real-time production line should be developed. The objectives of this paper is to measure the residual stress of butt welded specimen using strain gage sectioning method and to apply them to a neural network for prediction of residual stresses on a given process parameter. Also, the assessment of the developed system using a neural network was carried out

  • PDF

Evaluation of Fatigue Endurance for a Rocker Arm of Diesel engine (디젤 엔진 로커 암의 피로 내구성 평가)

  • Kim, Ho-Kyung;Yang, Kyoung-Tak;Kim, Hyun-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.1-6
    • /
    • 2007
  • In order to evaluate fatigue endurance for the rocker arm of a diesel engine, stress measurements were performed using the strain gages attached near the neck, where is one of the most critical region in the rocker arm, in variation of the engine speed. The fatigue life experiments were carried out on miniature specimens from the rocker arms. For evaluating the fatigue endurance of the rocker arm, the S-N data were compared with the stress analysis results through FEM analysis of the rocker arm. The effective stress of the neck region was determined 17.7MPa through FEM analysis of the rocker arm. Conclusively, on the basis of fatigue limit, the rocker arm has a safety factor of 2.8 or 3.4 from the stress measurement or FEM results, respectively.

A Study on the Evaluation of Thermal Stress of Massive Concrete Structure (매스콘크리트구조물의 온도응력평가에 관한 연구)

  • 강석화;정철헌;정한중;이용호;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.2
    • /
    • pp.126-135
    • /
    • 1995
  • Thermal cracks are occured when thermal stress due to the hydration of cement exceeds the tens~le strength of concrete. Since crackmg causes poor durability of concrete, the effect of ther ma1 cracking should be includod for the design and construction of massive concrete structures. In this study, an experiment is performed for the investigation of time dependent thermal stress history. In order to evaluate thermal stress. two methods are employed. One 1s the evaluation method of thermal stress based on the measurement from embedment stram gauge with non-stress strain gauge and the other 1s based on the measurement from concrete stress gauge. As a result of this study, the value corrected by the former shows good agreement with the latter. The validity of the proposed method for the evaluation of thermal stress 1s explored.