• Title/Summary/Keyword: Strength of Concrete

Search Result 10,934, Processing Time 0.037 seconds

Evaluation on the Sulfate Attack Resistance of Cement Mortars with Different Exposure Conditions (노출조건에 따른 시멘트 모르타르의 황산염침식 저항성 평가)

  • Lee, Seung Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.427-435
    • /
    • 2012
  • In order to evaluate the effects of exposure conditions on the resistance to sulfate attack of normal and blended cement mortars, several mechanical characteristics of the mortars such as expansion, strength and bulk density were regularly monitored for 52 cycles under sodium sulfate attack. The mortar specimens were exposed to 3 different types of exposure conditions; 1) continuous full immersion(Exposure A), continuous half-immersion(Exposure B) and cyclic wetting-drying(Exposure C). Experimental results indicated that the maximum deterioration was noted in OPC mortar specimens subjected to Exposure B, showing the wide cracks in the portions where attacking solution is adjacent to air. Additionally, the beneficial effect of ground granulated blast-furnace slag and silica fume was clearly observed showing a superior resistance against sodium sulfate attack, because of its lower permeability and densified structure. Thus, it is suggested that when concrete made with normal cement is exposed to sulfate environment, proper considerations on the exposure conditions should be taken.

Seismic Safety Enhancement of Damage-Controlled Reinforced Concrete Frames (손상제어 설계된 철근 콘크리트 프레임의 내진력 향상)

  • ;;Kim, Se Yoll
    • Computational Structural Engineering
    • /
    • v.4 no.3
    • /
    • pp.89-97
    • /
    • 1991
  • Conventional aseismic design methods of R/C frame all but disregard the state of damage over the entire building frame. This paper presents an automated damage-controlled design method for R/C frames which aims at an uniform energy dissipation rate throughout the building frame, so that the resulting damage is uniformly distributed as much as possible over all element. The accuracy of the basic hystertic model and the damage model for R/C members is verified by reproducing the experimental load-deformation curves of one-bay one-story frames. Application of this design method to various frame structures indicate that 1) regardless of the structural properties or input earthquake characteristics, damage-controlled frames generally survive more severe earthquake excitations and suffer less damage than conventionally designed frames, and 2) member yielding strength in the lower stories of damage-controlled frames is larger than that for conventionally designed frames, while the trend is opposite in the upper stories.

  • PDF

An Experimental Study on The Fire Resistance Performance of High Strength Concrete Column mixed Fiber-Cocktail in Standard Fire Condition (하이브리드 섬유를 적용한 고강도 내화콘크리트의 단면크기에 따른 내화성능에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Bum-Yean;Min, Byung-Youl;Ahn, Chan-Sol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.170-175
    • /
    • 2011
  • 최근 고강도 콘크리트의 내화성능이 사회적 이슈로 부각되고 국토해양부에서 고강도 콘크리트의 내화성능 관리기준(안)이 고시되면서 국내에서도 고강도 콘크리트의 내화성능을 향상시키기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 유기질 섬유인 폴리프로필렌섬유(PP섬유)와 강섬유를 하이브리드한 Fiber Cocktail를 혼입한 고강도 내화콘크리트 개발을 위한 연구를 수행하였다. PP섬유는 $160^{\circ}C$의 온도에서 용융되어 콘크리트 내부에 미세한 통로를 형성하여 고강도 콘크리트 부재 내의 수증기압 및 공극압을 효과적으로 배출하여 고강도 콘크리트의 폭렬발생을 억제시키는 데 효과적이며, 강섬유는 PP섬유가 용융된 후의 고강도 콘크리트 부재의 균열 발생을 억제하며 외부로부터 침투하는 열기를 차단할 수 있다. 100MPa 고강도 콘크리트의 내화실험을 실시하여 최적단면 조건을 도출하기 위해 철근온도를 분석한 결과, 단면이 커질수록 철근온도는 점차 낮아지는 경향이 나타났으며 $600{\times}600mm$, $800{\times}800mm$ 단면에서 내화성능을 확보할 수 있는 것으로 나타났으며, 이중 경제성을 고려할 경우 $600{\times}600mm$ 단면이 최적단면으로 도출되었다. 또한 도출된 $600{\times}600mm$ 단면에 대해서 철근의 온도를 분석한 결과 PP섬유 $1.5kg/m^3$와 강섬유 $40kg/m^3$를 배합한 Fiber Cocktail이 최적배합비로 나타났다.

  • PDF

Experimental Study on Lap Splice of Headed Deformed Reinforcing Bars in Tension (인장력을 받는 확대머리 이형철근의 겹침이음에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.59-67
    • /
    • 2014
  • In tension lap splices of straight deformed bars, KCI Code (KCI2012) and ACI Code (ACI318-11) requires that the lap lengths for class B splice are 1.3 times as development length. KCI2012 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. The purpose of this experimental study is to evaluate that KCI2012 equation for the development length, $l_{dt}$, of headed bars can be used to calculate the lap length, $l_s$, of headed deformed bars in grade SD400 and SD500, having specified yield strength of 400 and 500 MPa. Test results showed that specimens with $l_s$ equal to $1.3l_{dt}$ had maximum flexural strengths as 1.16~1.31 times as the nominal flexural strengths, flexural failure mode, and ductility. These observations indicate that $1.3l_{dt}$ is suitable to the tensile lap length of headed deformed bars in grade SD400 and SD500.

A Development of the Automated Vertical Controllable Device for Improving Construction Performance of Pile Driver (파일드라이버 기계 시공성능 향상을 위한 연직 자동제어기의 개발)

  • Cho, Chang-Yeon;Lee, Jun-Bok;Son, Jae-Ho;Kim, Han-Soo;Cho, Moon-Young
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.4 s.32
    • /
    • pp.78-90
    • /
    • 2006
  • There is no specific code and/or standard described in the specifications to check verticality for Pre-tensioned Spun High Strength Concrete pile installation process. The most commonly used method for the vertical PHC pile installation is a naked-eye measurement or water level measurement conducted by assistant crew in the construction sites. The main objective of the research is to develop the automated vertical controllable prototype equipment for PHC piles in order to achieve uniform construction qualify as well as improving safety and productivity. The paper explains the literature review on PHC pile and pile installation process, development of prototype, field test of the prototype and its performance evaluation in terms of quality and safety as well as productivity. The results of the research will lead the further researches on the automated pile installation system.

Development of Eco-friendly Cement using Reverse Osmosis Brine Water and Metakaolin (역삼투압 농축수와 메타카올린을 사용한 친환경 시멘트의 개발)

  • Kim, Taewan;Han, Ki-Bong;Kim, Do-Hyung;Seo, Ki-Young
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.216-222
    • /
    • 2021
  • This is an experiment to complement new ways of using concentrated water discharged from the seawater desalination plant. In this study, metakaolin, which has excellent chloride ion immobilization effect, was used as the main binder, and 10% and 20% of calcium oxide were substituted with the activator. In addition, tap-water(TW) and reverse osmosis brine water(RW) were used as mixed water. As a result of the experiment, the mixture using RW showed higher compressive strength than TW. It also showed low water absorption and high density. In the mixture using RW as mixed water, a hydration reaction substance called Friedel's salt could be observed. Considering the corrosion problem of steel, RW is considered to be applicable to products such as non-reinforced concrete, brick, and curb stone. Through this study, it is thought that it is meaningful to propose a new application method other than the ocean release of RW.

A Study on the Properties of Cementless Artificial Stone by Recycled Coarse Aggregate and Red Mud According to Replacement Ratio (순환 굵은골재 및 레드머드 치환율에 따른 무시멘트 인조석재의 특성에 관한 연구)

  • Park, Ju-Hwa;Pyeon, Su-Jeong;Lee, Sang-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.50-56
    • /
    • 2019
  • This study aims to make artificial stone by recycling blast furnace slag powder, red mud and recycled aggregate, which are known as industrial waste. Recycled aggregate is a typical construction waste, and various recycled products such as concrete block are being sold. In this study, we tried to make artificial stone mixed with waste such as recycled aggregate, and experimented with the use of artificial stone and further study. As the red mud replacement ratio increased, the absorption ratio, fluidity and air content of the matrix were measured to be decreased, and the strength and density were found to increase. The fluidity and absorption ratio decreased with increasing the replacement ratio of recycled aggregate, and the air quantity, rate of aggregate on the surface, density and intensity increased to a certain level. Therefore, this study intends to make artificial stone using recycled resources and conducted basic experiments for further study.

A Study on the Development and the Practical Approach for Repair Method of RC Structures Subjected to the Chemical Attack (화학적 침식을 받은 콘크리트구조물의 보수기술 개발과 실용화연구)

  • Moon, Han-Young;Shin, Dong-Gu;Kwon, Young-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.155-162
    • /
    • 2005
  • This paper presents an invetigation into the cause of deterioration of wet surrounding RC structures subjected to checmical attacks such as sewage. The antibacterial-reforming agent is developed after determining the permeability of the RC structure. After application of the anitbacterial-reforming agent through SEM, the permeability, compressive strength properties and the micro-structure of the concrete were evaluated for durability. In addition, the antibacterial-reforming agent was combined with a protective coating for the wet surrounding RC structure and evaluated for durability. The combined effect of the antibacterial-reforming agent and the protective coating were evaluated in field tests in both sewer system and tunnel sites.

The Elementary Study on the Development for Test Methods of Load Resistance about Attachments on the Lightweight Wall (경량벽체의 부착물에 대한 하중저항성 평가방법 개발을 위한 기초적 연구)

  • Kim, Sang-Heon;Kim, Se-Whan;Choi, Soo-Kyung;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.119-126
    • /
    • 2015
  • The wall system has been also tending to shift from existing concrete wall to variable lightweight wall according to increasing use of column structure system in apartment construction. Therefore, wall needs certain amount of strength which also means the standard measurement of resistance against loading of wall attachments is needed. Nevertheless, there currently aren't enough researches of related standards for such measurement. For such reason, the research would be used as baseline data to development for test methods of load resistance about attachments on the lightweight wall, that presented improvements in the apparatus and maximum loads for domestic circumstances by researching current tests.

Probabilistic Risk Assessment of Coastal Structures using LHS-based Reliability Analysis Method (LHS기반 신뢰성해석 기법을 이용한 해안구조물의 확률론적 위험도평가)

  • Huh, Jung-Won;Jung, Hong-Woo;Ahn, Jin-Hee;An, Sung-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.72-79
    • /
    • 2015
  • An efficient and practical reliability evaluation method is proposed for the coastal structures in this paper. It is capable of evaluating reliability of real complicated coastal structures considering uncertainties in various sources of design parameters, such as wave and current loads, resistance-related design variables including Young's modulus and compressive strength of the reinforced concrete, soil parameters, and boundary conditions. It is developed by intelligently integrating the Latin Hypercube sampling (LHS), Monte Carlo simulation (MCS) and the finite element method (FEM). The LHS-based MCS is used to significantly reduce the computational effort by limiting the number of simulation cycles required for the reliability evaluation. The applicability and efficiency of the proposed method were verified using a caisson-type breakwater structure in the numerical example.