• Title/Summary/Keyword: Strength decrease

Search Result 2,831, Processing Time 0.027 seconds

An Adiabatic Characteristic on the Waste tyre Powders Mortar-Containing (폐타이어 분말을 혼입한 몰탈의 단열특성)

  • Choi, Jae-Nam;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.105-112
    • /
    • 2005
  • This is to find out that cement mortar mixed with waste tie particle can be applied for recycling it and enhanced to have shock absorption capacity. Therefore, architectural material specification and its related references for the disposal of it are based on for the study. Test has been performed with procedure, based on the Korea Standard insulation mortar and Compressive Strength Test has been done at K remicon factory approved by Korea Government in Korea, in order to decrease any possible error in mixing procedure. Test molds far insulation capacity and cohesive strength have been delivered to the expert agency for having more exact results. The result from the above test shows that waste tyre mixed with cement mortar has almost equal to the common concrete. This means that the recycling of the waste t)re will be demanded more and more in case of having continued development for this recycling area. And also waste t)to-using construction material can be more applied for construction area than existing material. Thus, this recycling method can be very usefully applied for solving environmental problem and for establishing economic aspect.

Effect of Antifoamer into Latex Modified Concrete with Rapid-Setting Cement (소포제가 초속경 라텍스개질 콘크리트에 미치는 영향)

  • 최상릉;이주형;김동호;김기헌;김경진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.355-360
    • /
    • 2002
  • The purpose of this study was to remove the excessive air foaming which was produced in mixing the RSLMC(latex-modified concrete with rapid- setting cement) by choosing the best antifoam agent type and the optimized quantity for performance improved RSLMC. A series of RSLMM(latex-modified mortar with rapid-setting cement) experiments were carried out as the basic for RSLMC with the main experimental variables such as antifiamer types(A, B, C, D), antifoamer contents(0, 1, 2, 3%). Air content test and compressive, flexural tests were carried out to measure the improved properties of RSLMM and RSLMC. Chloride ion permeability test was carried out to estimate water permeability resistance. The results of RSLMM showed that the decrease of 50% air content was obtained by admixturing a antifoam agent by 1%. The compressive strength and flexural strength at 3 hours after RSLMC placement were 235kgf/cm$^2$ and 49kgf/cm$^2$, respectively, which exceeded the flexural strength criterion of 45kgf/cm$^2$ in order to open the RSLMC placed to traffic. The chloride permeability using A and C antifoamer at 28 days were below 100 coulombs, which was the permeability rating of negligible according to ASTM.

  • PDF

Deformation Demand of the Precast Concrete Frame Buildings with Ductile Connection in Moderate Seismic Regions (연성적인 접합부를 가진 프리캐스트 콘크리트 골조건물의 변형수요)

  • 서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.89-98
    • /
    • 1999
  • This paper evaluates nonlinear response characteristics of precast concrete frame buildings. where plastics hinging occurs in the precast connection. Designs were developed for buildings of 5, 10 and 15 stories in hight for moderate seismic risk regions of the U. S. The responses of the buildings were analyzed using DRAIN-2DX and following Nonlinear static analysis procedure of ATC 19. The main variables of the analyses were the strength and stiffness of the connection. Also, for the analysis, the bi-linear response model, developed and inserted into the DRAIN-2DX program by Shan Shi and D. Fouch, was used. With the results of analysis, the deformation demands of the connection of precast concrete frame buildings are proposed by using equal-dissipated energy capacity. It was shown that the strength of the buildings as well as their displacement capacities decreased with the decrease of either the strength or stiffness in the connections. Therefore such changes also require reductions in the response modification factors for such buildings. However, if the precast concrete frame building has plastic hinging in the connection, and has a more ductile connection than the monolithic frame building, then no reduction in R may be necessary. The deformation demand required of the connection to achieve that condition is evaluated and a simple relation is suggested in the paper.

The Effect of Compressive Residual Stresses of Two-stage Shot Peening for Fatigue Strength of Spring Steel

  • Park, Keyoung Dong;Jung, Chang Gi;Kwon, Oh Heon
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.24-27
    • /
    • 2002
  • Recently the steel parts used in automobiles are required to be used under high stress more than ever before due to the need of keeping the weight down. To achieve this requirement of the high strength steel, it must be necessary to decrease inclusion contents and surface defects as like decarburization, surface roughness etc. In this study, the surface conditions are measured to know the influence on fatigue properties by two cases of two-stage shot peening and single-stage shot peening. And for this study, three kinds of spring steel (JISG408l-SUP7, SAE 9254 and DIN 50CrV4) are shaped. This study shows the outstanding improvement of fatigue properties at the case of two-stage shot peening in the rotating bending fatigue test and it results from (1) decreasing the surface roughness (2) unchanging the surface hardness (3) increasing the compressive residual stress. Moreover, results also show fatigue failures originated at the inclusion near the surface, and this inclusion type is turned out to be an alumina of high hardness.

Characteristics of fatigue crack propagations with respect to the angles between rolling and tensile loading directions of steel plates (강판의 압연 방향과 인장하중 방향의 상대 각도에 따른 피로 균열 진전 특성)

  • Lee Yong-Bok;Oh Byung-Duck
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.74-80
    • /
    • 2005
  • Steel plates used for common structures are manufactured by rolling processes in general. The rolling direction traces generated during the processes have significant influences on mechanical properties and fatigue behavior of the plates. The objective of present study is to investigate those directional characteristics for the enhancement of steel structure safety. SS400 steel plates of 3 mm thickness are tested in this study, When the angles between the tensile loading direction and the rolling direction of the plates are increased, their yield strengths are increased and elongations are rather decreased. It is also shown that fatigue crack growth rates in the plates can be increased according to the changes of those mechanical characteristics. For the safety of the structures, therefore, it is critical to decrease the angles between the rolling direction and the tensile loading direction.

Effect of Temperature on Tensile Fracture Behavior of Glass Fiber Polypropylene Composites (온도변화에 따른 GF/PP복합재료의 인장파괴거동)

  • 고성위;엄윤성;허경환;김엄기;김형진
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.240-245
    • /
    • 2001
  • The tensile strength and failure mechanisms of glass fiber polypropylene (GF/PP) composites are investigated in the temperature range from ambient to 8$0^{\circ}C$. The tensile strength increases as fiber volume fraction ratio increase. The tensile strength shows a maximum at ambient temperature, and it tens to decrease as temperature goes up. Major failure mechanisms of GF/PP composites can be classified as fiber matrix debonding, fiber pull-out, delamination and matrix deformation.

  • PDF

Numerical simulation of the effect of bedding layer geometrical properties on the punch shear test using PFC3D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming
    • Structural Engineering and Mechanics
    • /
    • v.68 no.4
    • /
    • pp.507-517
    • /
    • 2018
  • In this research the effect of bedding layer angle and bedding layer thickness on the shear failure mechanism of concrete has been investigated using PFC3D. For this purpose, firstly calibration of PFC3d was performed using Brazilian tensile strength. Secondly punch shear test was performed on the bedding layer. Thickness of layers were 5 mm, 10 mm and 20 mm. in each thickness layer, layer angles changes from $0^{\circ}$ to $90^{\circ}$ with increment of $25^{\circ}$. Totally 15 model were simulated and tested by loading rate of 0.016 mm/s. The results show that when layer angle is less than $50^{\circ}$, tensile cracks initiates between the layers and propagate till coalesce with model boundary. Its trace is too high. With increasing the layer angle, less layer mobilizes in failure process. Also, the failure trace is very short. It's to be note that number of cracks decrease with increasing the layer thickness. The minimum shear punch test strength was occurred when layer angle is more than $50^{\circ}$. The maximum value occurred in $0^{\circ}$. Also, the shear punch test tensile strength was increased by increasing the layer thickness.

A Study on the Changes in Microstructures and Mechanical Properties of Unidirectionally Solidified Al-Cu Alloys due to Cold-Rolling (Al-Cu 합금의 일방향 응고조직과 기계적 성질에 미치는 냉간압연의 영향)

  • Oh, Myung-Hwan;Ra, Hyong-Yong
    • Journal of Korea Foundry Society
    • /
    • v.3 no.1
    • /
    • pp.3-12
    • /
    • 1983
  • The influence of columnar dendirtes on the mechanical properties of Al-1% Cu alloys as unifirectionalloy solidified under the conditions of controlled crystal growth rate (R) and temperature gradient (G) was investigated. And the change of metallography and mechanical properties when unifirectionalloy solidified alloys and cast alloys were cold-rolled from 10% to 90% in reduction ratio was studied. The results are as follows: 1. The elongation and yield strength of unifirectionalloy solidified alloy are higher then those of cast alloy, but there is a little decrease in ultimate tensile strength. 2. The metallography and mechanical properties are changeable with the primary arm spacings when the unidirectionalloy solidified alloys were cold-rolled from 10% to 90% in reduction ratio. An alloy with larger primary arm spacings was easily changeable in metallography and mechanical properties when it was cold-rolled. 3. The tensile strength of transversely cold-rolled to 90% in reduction ratio was higher then that of longitudionalloy cold-rolled to 90% in reduction ratio. In the case, the fractorgraphs of fractured surface showed that the cast alloy and the unifirectionalloy solidified alloy was ductile-fractured, but the surface of transversely cold-rolled to 90% reduction of unidirection alloy solidified was slip plane qracture.

  • PDF

Concentration Effects on Improved Mechanical Properties of Chopped Kenaf Fiber Filled Polypropylene Composite (케냐프섬유로 강화된 PP복합재료내의 섬유의 함량이 기계적특성 향상에 미치는 효과)

  • Oh, Jeong-Seok;Lee, Seong-Hoon;Kim, Kwang-Jea
    • Elastomers and Composites
    • /
    • v.46 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • The effects of chopped kenaf fiber concentration on mechanical property of polypropylene (PP) composite are investigated. The addition of kenaf increased the tensile strength, flexural modulus, impact strength, specific gravity, and HDT, while decreased the elongation%, flexural strength, and melt flow index. The increase of mechanical properties is due to increased surface area contacting between fiber and polymer matrix and fiber-fiber interaction. Volatile extractives in the kenaf seemed to decrease the interfacial adhesion between kenaf surface and PP.

Preparation of Lightweight Aerated Concrete and Characteristic Analysis of Foaming Agent (경량기포콘크리트의 제조 및 기포제의 특성분석)

  • Yim, Going;Yim, Chai-Suk
    • The Journal of Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.31-50
    • /
    • 2006
  • Shrinkage may cause cracking in concrete. In practice such cracking must be considered in most concrete applications because, under normal conditions, drying of the concrete is unavoidable, and when drying takes place shrinkage occurs. Cracked concrete is an inferior concrete because it is weaker, more permeable, and more susceptible to chemical attack. The development of the strength of LAC with aging depends on a few factors such as type of the cement, W/C ratio, curing conditions and periods. The higher the strength of LAC, the lower the possibility of shrinkage cracking. Hence, the strength of LAC in the hypocaust system depends to a large extent on the effect of cracking decrease of the antifoaming rate to drying shrinkage in cement.

  • PDF