• Title/Summary/Keyword: Strength calculation

Search Result 651, Processing Time 0.025 seconds

Research on axial bearing capacity of cold-formed thin-walled steel built-up column with 12-limb-section

  • Wentao Qiao;Yuhuan Wang;Ruifeng Li;Dong Wang;Haiying Zhang
    • Steel and Composite Structures
    • /
    • 제47권3호
    • /
    • pp.437-450
    • /
    • 2023
  • A half open cross section built-up column, namely cold-formed thin-walled steel built-up column with 12-limbsection (CTSBC-12) is put forward. To deeply reveal the mechanical behaviors of CTSBC-12 under axial compression and put forward its calculation formula of axial bearing capacity, based on the previous axial compression experimental research, the finite element analysis (FEA) is conducted on 9 CTSBC-12 specimens, and then the variable parameter analysis is carried out. The results show the FEA is in good agreement with the experimental research, the ultimate bearing capacity error is within 10%. When the slenderness ratio is more than 96.54, the ultimate bearing capacity of CTSBC-12 decreases rapidly, and the failure mode changes from local buckling to global buckling. With the local buckling failure mode unchanged, the ultimate bearing capacity decreases gradually as the ratio of web height to thickness increases. Three methods are used for calculating the ultimate bearing capacity, the direct strength method of AISI S100-2007 gives result of ultimate axial load which is closest to the test and FEA results. But for simplicity and practicality, a simplified axial bearing capacity formula is proposed, which has better calculation accuracy with the slenderness ratio changing from 30 to 100.

Mechanical behavior of prefabricated steel-concrete composite beams considering the clustering degree of studs

  • Gao, Yanmei;Fan, Liang;Yang, Weipeng;Shi, Lu;Zhou, Dan;Wang, Ming
    • Steel and Composite Structures
    • /
    • 제45권3호
    • /
    • pp.425-436
    • /
    • 2022
  • The mechanical behaviors of the prefabricated steel-concrete composite beams are usually affected by the strength and the number of shear studs. Furthermore, the discrete degree of the arrangement for shear stud clusters, being defined as the clustering degree of shear stud λ in this paper, is an important factor for the mechanical properties of composite beams, even if the shear connection degree is unchanged. This paper uses an experimental and calculation method to investigate the influence of λ on the mechanical behavior of the composite beam. Five specimens (with different λ but having the same shear connection degree) of prefabricated composite beams are designed to study the ultimate supporting capacity, deformation, slip and shearing stiffness of composite beams. Experimental results are compared with the conventional slip calculation method (based on the influence of λ) of prefabricated composite beams. The results showed that the stiffness in the elastoplastic stage is reduced when λ is greater than 0.333, while the supporting capacity of beams has little affected by the change in λ. The slip distribution along the beam length tends to be zig-zagged due to the clustering of studs, and the slip difference increases with the increase of λ.

생산성을 고려한 볼라드 및 볼라드 지지 구조의 최종강도 평가 (Ultimate Strength Assessment of Bollard and Its Foundation Considering Production Costs)

  • 오창민;정준모;조상래
    • 대한조선학회논문집
    • /
    • 제43권5호
    • /
    • pp.604-610
    • /
    • 2006
  • Common structural rules of JBP(Joint Bulker Project) and JTP(Joint Tanker Project), which will come into effect in 2006, invoke the necessity of the ultimate limit state(ULS) design for ship structures. Even though the many applications of ULS analysis have been performed for ship structures, there have few studies carried out for deck machineries and their supporting structures. Recently four major Korean shipbuilders(DSME, HHI, HHIC, SHI) jointly developed and proposed a new design standards for mooring fittings and also proposed the SWL (Safety Working Load) obtained based on the first yield criterion. In this study, various ultimate strength analyses were performed for bollards and their foundation structures whose yield strengths were quantified by the research consortium. Prior to performing the ultimate strength analyses, the numerical calculation method was substantiated with the test results provided in the joint work report. Based upon the results of this study, it can be concluded that the reinforcements to increase the yield strength are not always resulted in the enhancement of the ultimate strength. Furthermore, the additional production costs for the reinforcements can not be rewarded by the ultimate strength. Therefore, another alternative arrangements should be developed in the view point of ultimate strength.

공간적으로 보강된 복합재료의 강도예측 (Strength Prediction of Spatially Reinforced Composites)

  • 유재석;장영순;이상의;김천곤
    • Composites Research
    • /
    • 제17권5호
    • /
    • pp.39-46
    • /
    • 2004
  • 본 연구에서는 공간적으로 보강된 복합재(SRC)의 강도를 예측하였다. 각 방향의 라드(rod)와 라드의 체적에 비례하는 기지의 강성으로 표현되는 구조요소(structural element)를 정의하고, 이 구조요소에 파손판단식을 적용하여 SRC의 강도를 예측하였다. 라드의 파손판단식의 경우는 최대파손변형률을, 기지의 경우는 수정된 Tsai-Wu 파손판단식을 각기 적용하였다. 또한 SRC의 강도를 예측하기 위해서 라드와 SRC의 물성치를 측정하였다. 측정된 물성치는 라드의 인장 파손변형률, 3D SRC의 압축 파손변형률, $45^{\cir}$ 회전된 방향에서의 인장 및 압축 강도와 전단강도들이다. 3D/4D SRC의 강도분포는 각 SRC의 라드방향에서 크게 나타나고 라드에서 벗어날수록 작은 강도 값을 보였다. 강도의 전체분포를 보다 빠르게 계산하기 위해서 하중증분을 유동적으로 사용하였고, 하중이력을 구할 때는 균일한 하중이력을 사용하였다. 3D SRC의 라드방향 압축실험결과 해석의 비교에서 초기 기울기는 서로 잘 일치하였고, 강도값은 18% 정도의 차이를 보였다.

콘크리트의 인장강성을 고려한 RC보의 공칭비틀림강도 (Torsional Resistance of RC Beams Considering Tension Stiffening of Concrete)

  • 박창규
    • 콘크리트학회논문집
    • /
    • 제14권1호
    • /
    • pp.24-32
    • /
    • 2002
  • 전단문제에서는 일부 설계기준(AASHTO 1994)에 이미 수정압축장이론이 도입되었다. 그리고 현행 콘크리트 설계기준에는 콘크리트의 전단강도가 철근의 전단강도와 합하여 공칭전단강도를 계산하고 있다. 그러나 최근에 개정된 콘크리트설계기준에는 콘크리트의 비틀림강도가 공칭비틀림강도 계산에서 누락되었다. 콘크리트의 인장응력은 비록 크기가 작으나 균열후에 균열사이의 콘크리트에 존재한다. 그러나 휨과 비틀림문제에서는 균열 후 콘크리트의 인장강성은 생략되고 있다. 역학적으로 콘크리트보의 비틀림거동은 전단거동과 매우 유사하다. 그러므로 균열 후 콘크리트의 비틀림강도를 철근콘크리트 보의 공칭비틀림강도의 계산에 포함시켜야 한다. 본 논문에서는 콘크리트의 평균주인장응력이 이루는 콘크리트의 비틀림강도를 횡방향 비틀림철근의 비틀림강도와 함께 공칭비틀림강도를 구성함을 밝혔으며, 이의 타당성을 검증하기 위해 개정 전후의 ACI 의 설계기준에 의한 공칭비틀림강도와 함께 실험값과 비교하였다. 그 결과 본 논문이 제안한 모델에 의한 공칭비틀림강도가 가장 좋은 결과를 보였다.

Investigating the performance of polymer cement resistance in football stadium construction

  • Yangguang Zhang
    • Advances in concrete construction
    • /
    • 제15권3호
    • /
    • pp.203-213
    • /
    • 2023
  • New techniques, technologies, and materials should be used to design and build sports stadiums. Since this century, much progress has been made in covering the roofs of sports stadiums, and the possibility of accurate computer calculation has been provided for stadiums, so by choosing a new structure, we can double the beauty and resistance of these stadiums. A stadium has an excellent and valuable design when its structure, shell, building, materials, and joinery follow a high architectural idea at all levels and scales. This article examines the mechanical performance of polymer cement strength in the construction of football stadiums, along with their structural knowledge in the form of the best examples in the world. Portland cement is one of the most used materials for constructing football stadiums. However, its production requires spending a lot of money, wasting energy, and damaging the environment. Considering the disadvantages in the production and consumption of concrete in different environments, it is necessary to find alternative materials. It should be used with cheaper, simpler technology, abundant primary resources, energy saving, less environmental damage, and better chemical and physical properties in concrete. High-strength concrete technology is considered a new development in the construction industry of concrete structures. In hardened concrete, strength and durability are two main factors, and as the compressive strength of concrete increases, concrete becomes more brittle. As a result, its tensile strength does not increase in proportion to the increase in compressive strength and has less strain tolerance. For this reason, the need to use is evident from the fibers in high-strength concrete. Fibers are used in concrete to increase tensile strength, prevent crack propagation, and significantly increase softness. The increase with the change of these resistances depends on the strength of concrete without fibers, the shape of fibers, and the percentage of fibers. This cement is obtained from the wastes of chemical and petrochemical industries and the wastes from coal combustion, which have the properties mentioned as substitutes for Portland cement.

상변태를 고려한 핫프레스포밍 공정의 유한요소해석 (FE Analysis of Hot Press Forming Process considering the Phase Transformation)

  • 강경필;이경훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.226-229
    • /
    • 2008
  • Hot press forming is an advanced forming technology fur manufacturing of complex and crash-resistant automotive parts using ultra high strength steels. The 3-dimensional FE analysis of hot press forming process, in which process the deformation, heat transfer and phase transformation behavior are fully coupled, is carried out. The vast amount of material properties for the FE analysis is obtained from material properties calculation software which is based on thermodynamic calculations. The overall methodology for the FE analysis of HPF process and the analysis results are discussed here.

  • PDF

최고운행속도 350km/h급 전차선로 최대경간길이 계산 기법 (Technique of Maximum Span Length Calculation for 350km/h High Speed Catenary System)

  • 창상훈;이기원;유향복
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.924-931
    • /
    • 2011
  • This paper deal with maximum span calculation technique for 350km/h high speed catenary system. Considers a geometric interaction, possible maximum span length is between two pole. Wind condition and the train current collector is moving even to being pantograph does not escape while operating. Uses like this justice and possible maximum span length is follow next condition. (i) Operating range of pantograph fan head, (ii) The wind velocity which assumes from system, (iii) Width in pantograph from operation height moving, (iv) Type of processing Catenary system, specially tensile strength of overhead contact wire and messenger wire etc. When accurately calculates the maximum permission span, the dropper between of overhead contact wire and messenger wire and must consider the correlation.

  • PDF

HVDC시스템 밸브홀의 기계적 강도 계산 (Mechanical Strength Calculation of HVDC Valve Hall)

  • 김찬기;이성두;강지원;윤용범
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.442-448
    • /
    • 2016
  • This paper presents electromagnetic force effect of the conductor and insulator in the HVDC valve hall. This paper is based on IEC 60865, which is applicable to the mechanical and thermal effects of short-circuit currents. The paper contains procedures for the calculation of the electromagnetic effect on HVDC conductors and flexible conductors, as well as the thermal effect on HVDC conductors. The results are applied to the Godeok -Dangjin HVDC system.

부 타이어 소파제의 정적 장력 해석 방법 (Static Tension Analysis Method for Floating Tire Breakwater)

  • 윤길수;추원효
    • 한국수산과학회지
    • /
    • 제26권1호
    • /
    • pp.31-40
    • /
    • 1993
  • This paper deals with static tension analysis method for Floating Tire Breakwater(FTB). FTB can be used for the limited wave height. It is especially focused on Goodyear type FTB easily applied to the breakwater for the fisheries cultivating region. The numerical examples for FTB design procedure was reviewed. It is also studied the static analysis method of offshore catenary spread mooring system. The general calculation procedure for the tension versus excursion curves for the multi-line system using the basic catenary relationship was studied. Calculation results showed good agreement with some existing mooring results. To extend this mooring force calculating method to the floating fisheries caitivating cages, the strength of synthetic fiber was considered. This analysis method can be used to the estimation of the mooring force for the floating structures such as floating breakwaters and floating artificial reefs.

  • PDF