• 제목/요약/키워드: Strength Reduction Factor

검색결과 344건 처리시간 0.026초

산업부산물을 이용한 섬유보강 포장용 포러스콘크리트의 특성에 관한 연구 (A Study on the Properties of Fiber Reinforced Porous Concrete for Pavement using Industrial By-product)

  • 박승범;이윤선;이준;장영일;김봉균;김정환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.699-702
    • /
    • 2005
  • This study evaluates the properties of porous concrete for pavement according to content of silica fume and steel fiber. The results of the test indicate that in every condition, the void ratio and the coefficient of water permeability of porous concrete for pavement satisfy both the domestic standards and proposition values. Among the properties of strength, the compressive strength satisfies the standards in the specification of KNHC as for every factor of mixture but in the case of the flexural strength, more than $0.6vol.\%$ of steel fiber satisfied the JCI proposition values. The case when silica fume and steel fiber are used simultaneously presents the strongest durability and Noise Reduction Coefficient is 0.48 to prove that it possesses almost $50\%$ sound absorption.

  • PDF

유리섬유쉬트에 의한 실물모형 RC보의 보강매수별 휨 보강효과 (Flexural Strengthening with Multi-Layer GFRP Sheets on Full-Scale RC Beams)

  • 유영찬;최기선;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.177-180
    • /
    • 2005
  • The specified tensile strength provided by the manufacturer is determined on the basis of the reliable lower limit ($X-3{\sigma}$ : X=average tensile strength, $\sigma$=standard deviation) obtained from the material test results. Most of these data, however, are based on the test results of 1 layer of FRP sheet. Also, the partial strength reduction factor for strengthening RC members with FRP is based on the small-scale model tests. But, the failure mechanisms of small-scale model tests are reported to be different from those of the full-scale tests. This paper present the test results of full-scale RC beams strengthened with multi-layer GFRP sheets up to 3 layer as well as the material tests. From the material tests, it was observed that the average tensile strengths of GFRP sheets are decreased as the number of layer are increased. Also the premature debonding failure of RC beams strengthened with multi-layer GFRP sheets are observed in inverse proportion to the number of GFRP sheets

  • PDF

SBR과 나일론 접착을 위한 RTFL 접착제의 물성 (The Physical Properties of RTFL Adhesive for Bonding SBR to Nylon)

  • 정경호
    • Elastomers and Composites
    • /
    • 제28권4호
    • /
    • pp.274-282
    • /
    • 1993
  • Resorcinol-tannin-formaldehyde-latex(RTFL) adhesive was prepared to bond SBR to nylon in reinforced rubber composites. A key factor of adhesive contributes to the adhesion strength between SBR and nylon was the toughness of adhesive itself. Although the stiffness and strength of adhesive film decreased slightly with increasing level of tannin substitution for resorcinol in a standard RFL adhesive, the maximum toughness of adhesive film, which showed yield behavior and high dissipative capacity, was obtain by 60% tannin substitution. However, a marked softening and reduction in toughness occurred at sufficiently high substitution. Also, the adhesive film, which was heat-treated to simulate cure, showed higher strength than the unheated film. Thus, the properties of tannin containing adhesives could be optimized by using 40/60 weight ratio of the resorcinol/tannin in RTFL adhesive composition as well as heat treatment of adhesive film.

  • PDF

시공요소가 탄소섬유쉬트의 역학적 특성에 미치는 영향 (Effect of Construction Element on the Mechanical Properties of Carbon Fiber Sheet)

  • 이한승;유영찬;최근도;최거선;류화성;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1073-1078
    • /
    • 2000
  • This study is to investigate the effect of construction element such as the number of CFS ply, curing temperature, splice length and curing periods on the mechanical properties of Carbon Fiber Sheet (CFS). Through the tensile tests of CFS specimens, it can be said that the reduction factor stemmed from the number of CFS ply must be considered in the calculation of the design tensile strength of CFS. Also, the minimum splice length of CFS and curing period in $20^{\circ}C$ to satisfy the standard tension strength of CFS are over 5cm and after 3days, respectively. The measuring error of epoxy resin have no effect to tension strength of CFS until $\pm$20% error.

The effect of soil-structure interaction on inelastic displacement ratio of structures

  • Eser, Muberra;Aydemir, Cem
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.683-701
    • /
    • 2011
  • In this study, inelastic displacement ratios and ductility demands are investigated for SDOF systems with period range of 0.1-3.0 s. with elastoplastic behavior considering soil structure interaction. Earthquake motions recorded on different site conditions such as rock, stiff soil, soft soil and very soft soil are used in analyses. Soil structure interacting systems are modeled with effective period, effective damping and effective ductility values differing from fixed-base case. For inelastic time history analyses, Newmark method for step by step time integration was adapted in an in-house computer program. Results are compared with those calculated for fixed-base case. A new equation is proposed for inelastic displacement ratio of interacting system ($\tilde{C}_R$) as a function of structural period of interacting system ($\tilde{T}$), strength reduction factor (R) and period lengthening ratio ($\tilde{T}/T$). The proposed equation for $\tilde{C}_R$ which takes the soil-structure interaction into account should be useful in estimating the inelastic deformation of existing structures with known lateral strength.

순환굵은골재 치환율에 따른 콘크리트의 역학적 특성 (The Effect of Recycled Coarse Aggregate Replacement Level on the Mechanical Properties of Concrete)

  • 전에스더;윤현도;유영찬;이세현;심종우;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.505-508
    • /
    • 2006
  • This experimental study is to evaluate the effects of recycled coarse aggregate replacement level on the mechanical properties of concrete produced at Batcher plant. The main test parameter was replacement level of recycled coarse aggregate with the ratio of 0, 30, 60 and 100% to the natural coarse aggregate. From the test results, it was found that compressive strength, elastic modulus and splitting strength are decreased with the increased proportion of replacement level. Therefore, some design coefficients or recommendations for elastic modulus and splitting strength of concrete need to be reconsidered with minor reduction factor of '0.85'.

  • PDF

볼트 간격에 따른 낙엽송 집성재 이중 볼트접합부의 전단강도 (Lateral Strength of Double-Bolt Joints to the Larix Glulam according to Bolt Spacing)

  • 김건호;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권3호
    • /
    • pp.1-8
    • /
    • 2008
  • 볼트 간격에 따른 국내산 낙엽송 집성재 이중 볼트접합부의 내력성능을 검토하기 위하여 휨 type 전단강도실험을 실시하였다. 전단시편은 강판삽입형 볼트접합부 시편으로서 볼트구멍은 볼트직경(12 mm, 16 mm), 볼트 개수(단일 볼트 : Control, 이중 볼트), 볼트 열 방향(섬유평행 : Type-A, 섬유직교 : Type-B) 그리고 볼트 간격(Type-A : 4 d, 7 d, Type-B : 3 d, 5 d)을 달리하여 제작하였다. 조건에 따른 볼트접합부의 강도성능과 파괴형상을 비교, 검토하였다. 설계표준(KBCS, 2000)시 볼트간격이 감소된 기준허용전단내력에 대한 저감계수를 산출하였다. 본 연구의 결과는 다음과 같다. 1) 단일 볼트접합부와 Type-A의 이중 볼트접합부의 볼트 한 개당 지압응력은 볼트의 직경, 볼트 간격과 비례 관계를 보여주었다. Type-B의 지압응력은 볼트의 직경이 증가할 때 감소하였고, 볼트 간격이 증가할 때 2~10% 정도 감소하였다. 2) 단일 볼트접합부와 Type-A의 이중 볼트접합부의 파괴형상은 연단거리 방향으로 할렬파단이 일어났다. Type-B의 경우 볼트간격이 3 d일 때 인장부위 볼트가 압축부위 볼트보다 더 굴곡되었고 인장부위볼트에서 할렬파단이 시작되었다. 5 d 시편의 경우 인장부위와 압축부위 볼트의 굴곡은 비슷하게 나타났으며, 압축부위볼트에서 할렬파단이 시작되었다. 3) 설계표준시 기준볼트 간격(Type A : 7 d, Type B : 5 d)에 따른 항복하중을 무차원화시켜 저감계수를 산출하였다. 12 mm 볼트접합부의 경우 Type-A인 볼트 간격 4d와 단일 볼트접합부의 저감계수는 각각 0.87, 0.55였고 Type-B인 볼트 간격 3 d와 단일 볼트접합부의 저감계수는 0.91, 0.55였다. 16 mm 볼트접합부의 경우 Type-A인 볼트 간격 4 d와 단일 볼트접합부의 저감계수는 0.96, 0.76이었고 Type-B인 볼트 간격 3 d, 단일 볼트접합부의 저감계수는 0.91, 0.77이었다.

3차원 효과를 고려한 암반사면의 안전율 변화에 관한 연구 (A Study on the Factor of Safety for Rock Slopes Based on Three Dimensional Effects)

  • 서옥근;이승호
    • 한국지반공학회논문집
    • /
    • 제31권1호
    • /
    • pp.47-52
    • /
    • 2015
  • 사면안정분야의 해석과 설계에는 한계평형법(LEM)과 전단강도 감소기법(SSR)이 주로 사용된다. 이 두 방법은 2차원과 3차원 해석을 모두 수행할 수 있지만 많은 연구자들에 의해 전단강도 감소기법이 해석 변수에 대해 더욱 민감하게 반응하고 합리적인 결과를 산출한다고 알려져있다. 그러나 전단강도 감소기법의 모델링의 복잡함과 해석시간의 증가 등의 이유로 현계평형법이 여전히 일반적으로 사용되고 있다. 본 연구에서는 FLAC 3D를 사용하여 전단강도 감소기법을 통한 돌출된 암반사면의 3차원 효과에 대해 연구하였다. 수치해석 변수는 사면의 경사, 높이, 지반강도, 사면의 돌출길이이며 연구 결과 사면의 안전율은 암반의 강도보다 사면의 형상에 더 영향을 받는 것으로 나타났다.

소규모 지하공동 3차원 형상 특성을 반영한 수치해석에 관한 연구 (A numerical study on the 3-Dimensional shape characteristics of small underground cavities)

  • 안준상;강경남;송기일;김우석;김병찬
    • 한국터널지하공간학회 논문집
    • /
    • 제20권5호
    • /
    • pp.787-807
    • /
    • 2018
  • 한국에서 시행중인 특별법에 의한 지하안전영향 평가 수행 시, 필수적으로 지하공동의 발생 유무를 조사하여야 한다. 지하공동 발견 시에는 수치해석을 통해서 지하안전성을 평가하도록 규정하였다. 선행 연구를 통해서 소규모 지하공동의 2차원 형상변화를 통한 안전율 기반의 안정성 평가 가능성을 제시하였다. 본 연구에서는 3차원 형상을 고려하여 소규모 지하공동의 영향을 연속체 해석 프로그램을 사용해서 검토하였고, 선행 연구에서 제시한 2차원 해석결과와 비교하였다. 지하공동의 3차원 형상이 구(sphere)형에 가깝게 발견되면, 공동의 크기, 위치 등에 관계없이 전단강도감소기법으로 안전율을 산정하여 평가하는 방법에 무리가 없을 것으로 판단된다. 지표면으로부터의 깊이 2 m 이상, 장축과 단축의 비(a/b)가 2.0 이상인 장대형 지하공동이 연직방향으로 서있는 형상이라면, 전단강도감소기법을 사용한 안정성 평가에 안전율 이외에 파괴양상 파악에도 주의가 필요할 것으로 판단된다. 본 연구의 결과는 지하안전영향평가에 관한 기초 자료가 될 수 있을 것으로 판단된다.

조선 해양 구조물용 강재의 소성 및 파단 특성 IV: 고온 기계적 물성치에 관한 실험적 연구 (Plasticity and Fracture Behaviors of Marine Structural Steel, Part IV: Experimental Study on Mechanical Properties at Elevated Temperatures)

  • 정준모;임성우;박노식
    • 한국해양공학회지
    • /
    • 제25권3호
    • /
    • pp.66-72
    • /
    • 2011
  • This is the fourth of a series of companion papers dealing with the mechanical property reductions of various marine structural steels. Even though a reduction of the elastic modulus according to temperature increases has not been obtained from experiments, high temperature experiments from room temperature to $900^{\circ}C$ revealed that initial the yield strength and tensile strength are both seriously degraded. The mechanical properties obtained from high temperature experiments are compared with those from EC3 (Eurocode 3). It is found that the high temperature test results generally comply with the prediction values by EC3. Based on the prediction of EC3, time domain nonlinear finite element analyses were carried out for a blast wall installed on a real FPSO. After applying the reduced mechanical properties, corresponding to $600^{\circ}C$ to the FE model of the blast wall, more than three times the deflections were observed and it was observed that most structural parts experience plastic deformations exceeding the reduced yield strength at the high temperature. It is noted that a protection facility such as PFP (passive fire protection) should be required for structures likely to be directly exposed to fire and explosion accident.