• Title/Summary/Keyword: Stream flow rate

Search Result 400, Processing Time 0.028 seconds

An Experimental Study on the Characteristics of Temperature Separation for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브에서의 형상 변화에 따른 온도 분리에 관한 실험적 연구(I))

  • 황승식;전운학;김종철;이희상
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.84-93
    • /
    • 2001
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial temperature distribution and the radial temperature distribution in internal space of a tube. From the study, following conclusive remarks can be made. Average flow rate that flows into a tube is in proportion to square root of inlet pressure. As inlet pressure increases axial and radial temperature distribution in the inner space of vortex-tube increase. As mass flow rate ratio change, separation point moves.

  • PDF

Assessment of the Water Quality of Jungnang Stream by Flow Conditions Using Load Duration Curve (부하지속곡선을 이용한 중랑천의 유량 조건별 수질특성 평가)

  • Choi, Kyung-Wan;Shin, Kyung-Yong;Lee, Hyung-Jin;Jun, Sang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.438-447
    • /
    • 2012
  • Objective: The objective of this study was to suggest a method through which load duration curve was used to assess the achievement of water quality targets in accordance with the criteria for pollutant load depending on flow rate variation. Methods: The stage-discharge curve and flow duration curve of Jungnang Stream were deduced. Using water quality targets and measurement of the stream, the flow duration curve was also drawn. Based on these, the feasibility of achievement of water quality targets in respect to flow rate was assessed. Results: In terms of the load duration curve of the stream, it was observed that excess of criteria for concentrations of $BOD_5$, $COD_{Mn}$ and SS frequently occurred. On the other hand, when the flow rate was low, the concentrations of T-N and T-P exceeded the criteria. Conclusions: Through the load duration curve, the overall water quality of Jungnang Stream was understood. When the flow rate is high, management of point source of $BOD_5$, $COD_{Mn}$ and SS is needed to achieve water quality targets for Jungnang Stream. On the other hand, when the flow rate is low, the management of non-point source T-N and T-P is necessary to attain the water quality goal.

Computational Study of the MILD Combustion and Pollutant Emission Characteristics in Jet Flow Field (제트 유동장에서의 마일드 연소 및 오염물질 배출특성에 관한 전산해석 연구)

  • Kim, Yu Jeong;Song, Keum Mi;Oh, Chang Bo
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.4
    • /
    • pp.60-65
    • /
    • 2012
  • The MILD combustion and pollutant emission characteristics were investigated computationally. The temperature of supplying air-stream and mixing rate (${\Omega}$) of exhaust gas in the air-stream were adjusted to investigate the effects of those parameters on the MILD combustion in jet flow field. The emission indices for NO (EINO) and CO (EICO) were introduced to quantify the amount of those species emitted from the combustion. The high-temperature region disappeared gradually as the mixing rate increased for fixed air-stream temperature. The EINO increased as the air-stream temperature became higher for fixed mixing rate, and the EINO decreased dramatically with increasing the mixing rate for each air-stream temperature condition. The EICO also decreased with increasing the mixing rate and it was nearly independent of air-stream temperature except for near ${\Omega}$ = 0.7. It was found that the CO supplied in the air-stream can be destroyed in the MILD combustion over the certain mixing rate.

Environmental Changes of the Rivers in Taegu Area after a Heavy Rain (대구지방 하천의 집중 강우후의 수계환경의 변화)

  • Lyu, Seung-Won;Song, Seung-Dal
    • The Korean Journal of Ecology
    • /
    • v.6 no.2
    • /
    • pp.81-89
    • /
    • 1983
  • The change of environmental factors with flow rates were studied quantitatively for two rivers, the Nakdong River and the Sin stream, which have different basins in ecosystem structures, during short period after a heavy rain. In the Nakdong River, transparency, DO, alkalinity and hardness were negatively correlated with the flow rate by logarithmic function, but the concentration of SiO2 was relatively constant regardless of the flow chage. In the Sin stream, transparency, alkalinity, hardness and the concentration of NH3-N, NO2-N and SO4= showed negative correlation with the flow rate by logarithmic function. The ratios of maximum to minimum values for aquatic environmental factors during the samller than that for flow rate in the respective rivers (28 in the Nakdong R.; 50 in the Sin S.). Immediately after the heavy rain, the concentrations of NO2-N, NH3-N and PO4-P in the Sin stream were 8, 6 and 1 times as high as those in the Nakdong River, respectively, but in the stable flow state, those became 94, 25 and more than 10 times, respectively. The load for most of the dissolved environmental constituents changed similarly to the flow rate in both rivers. It is notable that, at the stable flow state, the loads for NH3-N (59g/sec) and NO2-N (3.3g/sec) in the Sin stream were 4.3 and 1.3 times as high as those in the Nakdong River.

  • PDF

Estimation of an Optimum Ecological Stream Flow in the Banbyeon Stream Using PHABSIM - Focused on Zacco platypus and Squalidus chankaensis tsuchigae - (PHABSIM을 이용한 반변천 하천생태유량 산정 - 피라미, 참몰개를 대상으로 -)

  • Park, Jinseok;Jang, Seongju;Song, Inhong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.6
    • /
    • pp.51-62
    • /
    • 2020
  • The objective of this study was to estimate an optimum ecological flow rate in the Banbyeon stream based on the two representative fish species. Hydraulic stream environment was simulated with HEC-RAS for two water flow regimes and used for the PHABSIM hydraulic simulation. A dominant species of Zacco platypus and an endemic species of Squalidus chankaensis tsuchigae were selected as the representative fishes whose habitat conditions were evaluated for the spawning and adult stages. Weighted usable area (WUA) was estimated based on habitat suitability index (HSI) and PHABSIM habitat simulation. Overall deep water zone in the stream demonstrated greater WUA which implies better habitat status. The estimated WUA for Zacco platypus as the dominant species was about five times greater than Squalidus chankaensis tsuchigae at the stream flow of 12 ㎥/s. The optimum ecological flow rates were 15 ㎥/s and 25 ㎥/s for the respective spawning and adult stages of Zacco platypus, while 5 ㎥/s was estimated for both the life cycles of Squalidus chankaensis tsuchigae. Assuming that the dominant species may survive better in wider flow regimes, the optimum ecological flow rate should be determined rater based on the endemic species and flow rate of 5 ㎥/s was suggested for the Banbyeon stream.

Characteristics of Non-point Pollutant Discharge from Upper Watershed of Seomjin Dam during Rainy Season (섬진강댐 상류 유역의 강우시 비점오염물질 유출 특성)

  • Kwak, Dong-Heui;Yoo, Seung-Joon;Kim, Ji-Hoon;Lim, Ik-Hyun;Kwon, Ji-Young;Chung, Paul-Gene
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.39-48
    • /
    • 2008
  • This study was carried out to investigate the characteristics of the pollutant discharge from non-point source and to estimate the unit loads of the pollutant discharge from the upper watershed of Seomjin Dam during rainy season. The upper watershed of Seomjin Dam is located in the middle of Jeonbuk province is formed two tributaries mainly. A sub-branch stream of those tributaries is Imsil stream of which flow rate is about 13% of the main stream of Seomjin reservoir normally. On the basis of measurement result in this study, the water quality of Imsil stream was fluctuated highly and the quantity of measured pollutant discharge was higher than the value calculated with the proportion of flow rate during dry season. On the contrary, during rainy season the mean values of flow rate and water quality were higher than the quartile according to the statistical analysis. That means rainfall can influence strongly on the water quality of the upper watershed of Seomjin reservoir. Among the several criteria of water quality, SS discharge was most sensitive to the flow rate variation of stream, which was fluctuated in proportion of rainfall, basically. It was evaluated the event mean concentration (EMC) of non-point source pollutants depending on rainfall events as well. Though the pollutant discharge unit of Imsil stream was lower than the main stream of Seomjin reservoir, the EMC value of Imsil stream was higher than the main stream of Seomjin reservoir.

An Experiment on the Effects of Free Stream Turbulence Intensity on the Backward-Facing Step Flow (자유흐름 난류강도가 후향계단유동에 미치는 영향에 대한 실험)

  • 김사량;유정열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2297-2307
    • /
    • 1995
  • An experimental study on the structure of a separated shear layer downstream of the backward-facing step has been performed by examining mean flow and turbulent quantities in terms of free stream turbulence. When free stream turbulence exists, the entrainment rate of the separated shear layer and the flow rate in the recirculation region are enhanced, resulting in shorter reattachment length. The production and diffusion terms in the turbulent kinetic energy balance are shown to increase more than the dissipation term does. Rapid decrease of the pressure-strain term in the shear stress balance implies the enhancement of the three-dimensional motion by free stream turbulence.

An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구)

  • 황승식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

EVALUATION OF GROUNDWATER-STREAM INTERACTION IN AN URBAN STREAM, CHEONGGYECHEON, KOREA

  • Hyun Yun-Jung;Kim Yoon-Young;Lee Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.328-331
    • /
    • 2005
  • Cheonggyecheon, covered and Paved with concretes for about more than 50 years, is a losing stream crossing over the downtown of Seoul, Korea. Due to several environmental and economic Problems about the Cheonggyecheon area, the Cheonggyecheon restoration construction has started in 2003. In restoration of Cheonggyecheon, hydraulic barriers are to be installed so as to reduce stream depletion rates for maintaining the stream flow with supplying a certain amount of water. This study evaluates the groundwater-stream interaction by analyzing stream depletion rates of Cheonggyecheon. Results show that significant stream depletion occurs at the up-midstream where the Seoul subway lines are concentrated. Simulation results demonstrate that both horizontal and vertical hydraulic barriers impeding groundwater flow into subway lines are more efficient than a horizontal barrier only for stream depletion rate reduction.

  • PDF

Mean Velocity Distribution of Natural Stream using Entropy Concept in Jeju (엔트로피 개념을 이용한 제주도 상시하천의 평균유속분포 추정)

  • Yang, Se-Chang;Yang, Sung-Kee;Kim, Yong-Suk
    • Journal of Environmental Science International
    • /
    • v.28 no.6
    • /
    • pp.535-544
    • /
    • 2019
  • We computed parameters that affect velocity distribution by applying Chiu's two-dimensional velocity distribution equation based on the theory of entropy probability and acoustic doppler current profiler (ADCP) of Jungmun-stream, Akgeun-stream, and Yeonoe-stream among the nine streams in Jeju Province between July 2011 and June 2015. In addition, velocity and flow were calculated using a surface image velocimeter to evaluate the parameters estimated in the velocity observation section of the streams. The mean error rate of flow based on ADCP velocity data was 16.01% with flow calculated using the conventional depth-averaged velocity conversion factor (0.85), 6.02% with flow calculated using the surface velocity and mean velocity regression factor, and 4.58% with flow calculated using Chiu's two-dimensional velocity distribution equation. If surface velocity by a non-contact velocimeter is calculated as mean velocity, the error rate increases for large streams in the inland areas of Korea. Therefore, flow can be calculated precisely by utilizing the velocity distribution equation that accounts for stream flow characteristics and velocity distribution, instead of the conventional depth-averaged conversion factor (0.85).