• Title/Summary/Keyword: Stratification effect

Search Result 268, Processing Time 0.025 seconds

A Numerical Study on Turbulent Damping Effect due to Density Stratification of Cohesive and Noncohesive Sediment (점착성 및 비점착성 유사의 밀도성층화에 따른 난류 영향에 대한 수치연구)

  • Son, Min-Woo;Lee, Guan-Hong;Lee, Du-Han
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.1
    • /
    • pp.66-74
    • /
    • 2011
  • This numerical study aims to investigate the effect of cohesive sediment on turbulence structure due to density stratification. The transport model for cohesive sediment incorporated with flocculation model has been selected and calculates the concentration, fluid momentum, and turbulence. From the model results, it is known that suspension of sediment decreases turbulence intensity. It is also found that cohesive sediment has a relatively weak effect on turbulence damping compared to noncohesive sediment. The low settling velocity and more suspension of cohesive sediment are considered to be mechanisms of this behavior. Richardson number determined with results of this study quantitatively shows that cohesive sediment causes less stable density stratification condition and, as a result, the turbulence structure is less damped compared to the case of noncohesive sediment.

Research about Thermal Stratification Effect on HCCI Combustion Fueled with Primary Reference Fuel (예혼합기의 열적성층화가 PRF연료의 예혼합압축자기착화에 미치는 영향)

  • Lim, Ock-Taeck
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.157-163
    • /
    • 2008
  • The HCCI combustion mode poses its own set of narrow engine operating by knocking. In order to solve this, inhomogeneity method of mixture and temperature is suggested. The purpose of this research is to get fundamental knowledge about the effect of thermal stratification on HCCI combustion of PRF -Air mixture. The temperature stratification is made by buoyancy effect in combustion chamber of RCM. The analysis items are pressure, temperature of in-cylinder gas and combustion duration. In addition, the structure of flames using the two dimensional chemiluminescence's images by a framing camera are analyzed. Under stratification, the LTR starting time and the HTR starting time are advanced than that of homogeneous. Further, the LTR period of homogeneous conditions became shorter than that of the stratified conditions. With the case of homogeneous condition, the luminosity duration becomes shorter than the case of stratified condition. Additionally, under stratified condition, the brightest luminosity intensity is delayed longer than at homogeneous condition.

Seasonal Variation of Coastal Front by Numerical Simulation in the Southern Sea of Korea (수치모델을 이용한 한국 남해안 전선의 계절변동)

  • Bae, Sang-Wan;Kim, Dong-Sun
    • Journal of Environmental Science International
    • /
    • v.20 no.9
    • /
    • pp.1141-1149
    • /
    • 2011
  • The three-dimensional hydrodynamic model was simulated to understand coastal sea front of formation and seasonal variation in the Southern Sea of Korea. In this study, we used to concept of stratification factor, to realize seasonal distribution of stratification coefficient which of seasonal residual flow, considered with, tide, wind and density effect. Tidal current tends to flow westward during the flood and eastward during ebb. The current by the wind stress showed to be much stronger the coastal than the offshore area in the surface layer. And the current by the horizontal gradient of water density showed to be relatively weak in the coastal area, with little seasonal differences. On the other hand, the flow in the offshore area showed results similar to that of the Tsushima Warm Current. The stratification factor (SHv) was calculated by taking into account the total flow of tide, wind and density effect. In summer, the calculated SHv distribution ranged from 2.0 to 2.5, similar to that of the coastal sea front. The horizontal temperature gradient showed to be strong during the winter, when the vertical stratification is weak. On the other hand, the horizontal gradient became weak in summer, during which vertical stratification is strong. Therefore, it is presume that the strength of vertical stratification and the horizontal temperature gradient affect the position of the coastal sea front.

Positive Research About Water Aeration Improvement to Break Thermal Stratification of Dam (댐내 수온성층 파괴를 위한 산기식 수중폭기설비 성능향상 실증연구)

  • Park, Jong-Ho;Ra, Beyong-Pil
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.37-42
    • /
    • 2014
  • In Korea while the dam or reservoir is an important water resource, the value of this water resource is deteriorating by thermal-induced stratification. To ameliorate the water quality of reservoir by breaking stratification the use of air diffuser system is now widespread in Korea. According to the previous research, dynamics of bubble plume and destratification efficiency depended upon two dimensionless groupings; Mh and Pn suggested by Asaeda et al (1993). However, these two variables only include Q, N, H, g, u. and installed Boryeong reservior in appropriate width of water aeration, air dose and number of installations after calculating by applying these figures. This paper is performed to find out effect analysis about water aeration improvement to break thermal stratification.

Study on the Effect of Thermal Stratification on DME/n-Butane HCCI Combustion (열적성층화가 DME/n-Butane 예혼합압축자기착화연소에 미치는 영향에 관한 연구)

  • Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1035-1042
    • /
    • 2010
  • The thermal stratification effect has been thought as one of the way to avoid dramatically generating the heat from HCCI combustion. We investigate the effect of thermal stratification on HCCI combustion fueled by DME and n-Butane. The thermal stratification occurs in a combustion chamber of a rapid compression machine with premixture by buoyancy effect that is made of fuel and air. The premixture is then adiabatically compressed, and during the process, the in-cylinder gas pressure is measured and two-dimensional chemiluminescence images are prepared and analyzed. Under the thermal stratification, the LTR starting time and the HTR starting time are advanced than that of homogeneous case. Further, the LTR period and the luminosity duration under homogeneous conditions are shorter than the corresponding quantities under stratified conditions. Additionally, under stratified conditions, the brightest luminosity intensity is delayed longer than that of homogeneous condition.

The Spatial Characteristics of Stratification in Deukryang Bay, Korea (밀도류 효과에 으히나 득령만의 성층변동 특성)

  • Byung-Gul Lee;Kyu-Dae Cho
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.223-232
    • /
    • 1998
  • The spatial characteristics of stratification In Deukryang Bay were studded using observed data and analytical models. From the description of the density structure and its the potential energy anomaly (PEA) from observed data along longitudinal direction (from the mouth to head of the bays, we found that the stratification Intensity could be changed strongly by density current effect during the spring-neap tidal cycle, and depth variation. To find out density current effect for the formation of the stratification In detail, we Implemented a diagnostic approach by using the modified analytical model including density current, tidal current, surface heating and wind stirring. The model allowed for the observed similarities for the whole domain in the bay and increased tidal mixing efficiency value s up to 0.006-0.007 as compared to the results without density current effect. We found that the density current effect was also an important key factor In determining the formation of the spatial distribution of stratification.

  • PDF

Optimal Harvesting Time of Ginseng Seeds and Effect of Gibberellic Acid (GA3) Treatment for improving Stratification Rate of Ginseng (Panax ginseng C. A. Meyer) Seeds (인삼 종자의 개갑률 향상을 위한 적정 수확시기 및 GA3 처리 효과)

  • Kim, Young Chang;Kim, Young Bae;Park, Hong Woo;Bang, Kyong Hwan;Kim, Jang Uk;Jo, Ick Hyun;Kim, Kee Hong;Song, Beom Heon;Kim, Dong Hwi
    • Korean Journal of Medicinal Crop Science
    • /
    • v.22 no.6
    • /
    • pp.423-428
    • /
    • 2014
  • This study was performed to identify optimal harvesting time of ginseng seeds and to examine the effect of $GA_3$ treatment for improvement of seed stratification rate. Ginseng seeds harvested from Land race, Chunpoong and Yunpoong cultivar in July 20 were tested for stratification rate. It was shown that stratification rates of land race, Yunpoong and Chunpoong cultivar were 94.1%, 93.1%, and 82.6%, respectively. Seeds of Chunpoong cultivar harvested 10-15 days later showed a comparable stratification rate to that of Land race, indicating that late harvest of Chunpoong seeds is beneficial for the increase of stratification rate. The higher stratification rate was found in mature seeds (92.3%) than immature seeds (37.8%), both of which were harvested in July 20. Stratification rate of mature seeds harvested in July 15 was 87.5%, demonstrating optimal harvesting time of ginseng seeds with higher stratification rate is after mid-July. An exponential growth of endosperms of ginseng seeds was observed from early June to mid-June and then slow growth was observed. There was no obvious growth of embryos from fertilization to mid-August. After the this time, embryos quickly grew until late October. Thus, appropriate stratification control is essential during the period (from early September to late October) in order to optimize embryo growth and development. While no increase of stratification rate was observed in seeds treated with 50 ppm of $GA_3$, significant increases were observed in seeds treated with 100 ppm of $GA_3$. At this concentration of $GA_3$, the stratification rate of Land race, Chunpoong and Yunpoong cultivar was 95.0%, 95.3%, and 96.5%, respectively.

The Effect of Turbulence Penetration on the Thermal Stratification Phenomenon Caused by Coolant Leaking in a T-Branch of Square Cross-Section

  • Choi, Young-Don;Hong, Seok-Woo;Park, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.51-60
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can occur due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, effects of turbulence penetration on the thermal stratification into T-branches with square cross-section in the modeled ECCS are analysed numerically. Standard k-$\varepsilon$ model is employed to calculate the Reynolds stresses in momentum equations. Results show that the length and strength of thermal stratification are primarily affected by the leak flow rate of coolant and the Reynolds number of duct. Turbulence penetration into the T-branch of ECCS shows two counteracting effects on the thermal stratification. Heat transport by turbulence penetration from main duct to leaking flow region may enhance thermal stratification while the turbulent diffusion may weaken it.

SIMULATION OF THERMAL STRATIFICATION IN INLET NOZZLE OF STEAM GENERATOR

  • Ji, Joon-Suk;Youn, Bum-Su;Jeong, Hyun-Chul;Kim, Sang-Nyung
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.287-294
    • /
    • 2009
  • Due to thermal hydraulics phenomena, such as thermal stratification, various events occur to the parts of a nuclear power plant during their lifetimes: e.g. cracked and dislocated pipes and thermally fatigued, bent, and damaged supports. Due to the operational characteristics of the parts of the steam generator feedwater inlet horizontal pipe, thermal stratification takes place particularly frequently. However, the thermal stress due to thermal stratification at the steam generator feedwater inlet horizontal pipe was not reflected in the design stage of old plants(Kori Unit No.1, 2, 3 and 4, Yeonggwang Unit No. 1 and 2, and Uljin Unit No. 1 and 2; referred to as old-style power plants hereinafter). Accordingly, a verification experiment was performed for thermal stratification in the horizontal inlet nozzle steam generator of old-style plants. If thermal stratification occurred in the horizontal pipe of an old-style power plant, numerical analysis of the temperature distribution of the pipes and fluids was conducted. The temperature distributions were compared at the curved part of the pipe and the horizontal pipe before and after the installation of the improved thermal sleeves designed to alleviate thermal stress due to thermal stratification. The thermal stress reduction measure was proven effective at the steam generator inlet horizontal pipe and the curved part of the pipe.

The Effect of Turbulence Penetration on the Thermal Stratification Phenomenon Caused by Leaking Flow in a T-Branch of Square Cross-Section (난류침투가 사각단면 T분기관 내 누설유동에 의해 발생한 열성층 현상에 미치는 영향)

  • 홍석우;최영돈;박민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.239-245
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can occur due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, effects of turbulence penetration on the thermal stratification into T-branches with square cross-section in the modeled ECCS are analysed numerically. $textsc{k}$-$\varepsilon$ model is employed to calculate the Reynolds stresses in momentum equations. Results show that the length and strength of thermal stratification are primarily affected by the leak flow rate of coolant and the Reynolds number of the main flow in the duct. Turbulence penetration into the T-branch of ECCS shows two counteracting effects on the thermal stratification. Heat transport by turbulence penetration from the main duct to leaking flow region may enhance thermal stratification while the turbulent diffusion may weaken it.