• Title/Summary/Keyword: Strategy for storage

Search Result 411, Processing Time 0.025 seconds

Control strategy for economic operation of an ice-storage system considering cooling load variation (냉방부하 변동을 고려한 빙축열시스템의 경제적 운전방식)

  • 정성훈;이대영;강병하;김우승
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.140-149
    • /
    • 2000
  • A comparative analysis was peformed on the operation cost at partial loads between ice storage systems with the two conventional control strategies, i.e., storage priority and chiller priority. The storage priority control is shown to be more economic for small cooling loads, while the chiller priority control is superior when the cooling load is as large as the design value. Based on this finding, a new control strategy is devised for an ice-storage system to minimize the operation cost at any cooling load. The new control strategy is found to be comparable to the chiller priority for large cooling loads, while it is more economic for small loads compared to the conventional control strategies. The practicality of the new control strategy is also confirmed through a performance test applying the new control strategy to an existing ice-storage system.

  • PDF

Comparative analysis of the minimum capacity of an ice-on-coil thermal storage system for various operation strategies (관외 빙착형 빙축열시스템의 운전방식에 따른 최소용량 비교)

  • 이대영;정성훈;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.401-413
    • /
    • 1999
  • An ice storage cooling facility with cooling capacity of 150㎾ has been constructed for the purpose of developing optimal design and control strategy for an ice storage system. As the first step to this purpose, a computer program has been developed to simulate the operation of the ice storage system and examined precisely by comparing the results with those measured from the test facility. With the simulation program verified from the comparison, a design procedure has been developed to determine the minimum capacity required for each operation strategy available commercially. It is shown that the minimum sizes of the chiller and the storage tank are strongly dependent on the control strategy, i.e., chiller priority or storage priority, but less affected by the arrangement method, i.e., chiller upstream or chiller downstream.

  • PDF

The Operation Characteristics and Cost Analysis of an Ice Thermal Storage System (빙축열 냉방시스템의 운전특성 및 비용 분석)

  • Ahn Young Hwan;Kang Byung Ha;Kim Suk Hyun;Lee Dae Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.156-164
    • /
    • 2005
  • A comparative analysis of an ice storage system has been performed on the operation cost for the four control strategies, i.e., chiller priority and chiller downstream, chiller priority and chiller upstream, storage priority and chiller upstream, storage priority and chiller downstream. Main components of the ice storage system are an ice-on-coil storage tank and a screw compressor chiller. With the simulation program, the operation cost has been evaluated from the economics of an ice storage system. It is found that the operation cost of the ice storage system is strongly dependent on the control strategy, i.e., chiller priority or storage priority, but less affected by the arrangement method, i.e., chiller upstream or chiller downstream. In case of the maximum load day, the control strategy with chiller priority and chiller upstream is supposed to obtain the reduction of operation cost. However, it is found that the control strategy with storage priority and chiller downstream is the best economical operation for most summer seasons except the maximum load day.

A Time-Segmented Storage Structure and Migration Strategies for Temporal Data (시간지원 데이터를 위한 분리 저장 구조와 데이터 이동 방법)

  • Yun, Hong-Won;Kim, Gyeong-Seok
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.4
    • /
    • pp.851-867
    • /
    • 1999
  • Numerous proposals for extending the relational data model as well as conceptual and object-oriented data models have been suggested. However, there has been relatively less research in the area of defining segmented storage structure and data migration strategies for temporal data. This paper presents the segmented storage structure in order to increment search performance and the two data migration strategies for segmented storage structure. this paper presents the two data migration strategies : the migration strategy by Time granularity, the migration strategy by LST-GET. In the migration strategy by Time Granularity, the dividing time point to assign the entity versions to the past segment, the current segment, and future segment is defined and the searching and moving process for data validity at a granularity level are described. In the migration strategy by LST-GET, we describe the process how to compute the value of dividing criterion. searching and moving processes are described for migration on the future segment and the current segment and entity versions 새 assign on each segment are defined. We simulate the search performance of the segmented storage structure in order to compare it with conventional storage structure in relational database system. And extensive simulation studies are performed in order to compare the search performance of the migration strategies with the segmented storage structure.

  • PDF

A Study on Optimal Operation Strategy for Mild Hybrid Electric Vehicle Based on Hybrid Energy Storage System

  • Bae, SunHo;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.631-636
    • /
    • 2018
  • This paper proposed an optimal operation strategy for a hybrid energy storage system (HESS) with a lithium-ion battery and lead-acid battery for mild hybrid electric vehicles (mild HEVs). The proposed mild HEV system is targeted to mount the electric motor and the battery to a conventional internal combustion engine vehicle. Because the proposed mild HEV includes the motor and energy storage device of small capacity, the system focuses on low system cost and small size. To overcome these limitations, it is necessary to use a lead acid battery which is used for a vehicle. Thus, it is possible to use more energy using HESS with a lithium battery and a lead storage battery. The HESS, which combines the lithium-ion battery and the secondary battery in parallel, can achieve better performance by using the two types of energy storage systems with different characteristics. However, the system requires an operation strategy because accurate and selective control of the batteries for each situation is necessary. In this paper, an optimal operation strategy is proposed considering characteristics of each energy storage system, state-of-charge (SOC), bidirectional converters, the desired output power, and driving conditions in the mild HEV system. The performance of the proposed system is evaluated through several case studies with respect to energy capacity, SOC, battery characteristic, and system efficiency.

Efficient Distributed Storage for Space Information Network Based on Fountain Codes and Probabilistic Broadcasting

  • Kong, Bo;Zhang, Gengxin;Zhang, Wei;Dong, Feihong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.6
    • /
    • pp.2606-2626
    • /
    • 2016
  • This article investigates the distributed data storage problem in the space information network (SIN) using distributed fountain codes. Since space nodes in the SIN are resource-limited, in order to reduce energy consumption while improving the storage reliability, an efficient distributed storage based on fountain codes and probabilistic broadcasting (DSFPB) strategy is proposed. In the proposed strategy, source packets are disseminated among the entire network according to probabilistic broadcasting (PBcast), and the final degree distribution is close to the desired robust soliton distribution (RSD), this is benefited from the appropriate packets encoding procedure of the proposed strategy. As presented by the analysis and simulations, the total cost of data dissemination is greatly reduced compared with existing representative strategies, while improving the decoding performance.

Optimal Scheduling of Multi-product Batch Process for Common Intermediate Storage Policy; A Model for Batch Process Automation (다품종용 회분식 공정에서의 중간 저장 탱크 공유를 위한 최적 생산계획 ; 회분식 조업의 자동화 모델)

  • 정재학;이인범;양대륙;장근수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.303-308
    • /
    • 1992
  • In this study, we propose a shared storage system which is more efficient policy than MIS(Mixed Intermediate Storage) policy for relatively rare storage system and can be called CIS(Common Intermediate Storage) policy. Using this strategy, we develop a new completion time algorithm and apply it to two kinds of optimal or near optimal scheduling method; combinatorial search and simulated annealing method. We also extend this strategy to other storage policy, for example MIS policy, with PLC(Programmable Logic Controller) logic and on/off action of electronic valves. It thus can be accepted as a basic form of FMS(Flexible Manufacturing System) for operating various storage policies. Finally we suggest the interlocking block to compansate for the shortcoming of CIS policy, i.e, complication of operation and safety, resulting in a basic batch process automation mode.

  • PDF

Design of Coordinated Frequency Control Strategy applied to EDLC and BESSs for Microgrid in the Islanded Mode (독립운전 모드의 마이크로그리드에서 EDLC와 BESS의 주파수 협조제어전략 설계)

  • Yoo, Hyeong-Jun;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.820-827
    • /
    • 2014
  • Since a microgrid has renewable energy sources, imbalance between power supply and power demand occurs in the islanded mode. In order to solve the imbalance, several energy storage systems (ESSs) such as bettary energy storage system (BESS), EDLC (electric double layer capacitor), flywheel, and SMES (superconducting magnetic energy storage) are generally used. Especially, their electrical characteristics are different. For efficient use of them, a coordinated control scheme is required. In this paper, a coordinated control scheme for using a Lead-acid BESS, a Lithium BESS, and a EDLC is designed to efficient frequency control for a microgrid in the islanded mode. The coordinated frequency control strategy is designed based on their electrical characteristics. The feasibility of the proposed coordinated frequency control strategy is verified through the simulation.

Switching Control Strategy of Bidirectional Converter for Energy Storage System in Photovoltaic Hybrid Modules (태양광 Hybrid Module용 에너지 저장 장치에서의 양방향 컨버터 스위칭 제어 기법)

  • Jang, Jin-Woo;Park, Yun-Ho;Kim, Young-Ho;Choi, Bong-Yeon;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.467-468
    • /
    • 2013
  • In this paper, a switching control strategy of bidirectional converter for energy storage system in photovoltaic hybrid modules is proposed. The bidirectional converter for energy storage system (ESS) with battery is connected with DC link in parallel which is located between current source flyback converters(CSFC) and unfolding bridge. Because CSFC generates rectified sinusoidal current, the bidirectional converter requires suitable control strategy. Therefore, a theoretical analysis of the proposed switching control strategy is presented. And, validity is confirmed through simulation results.

  • PDF

An adaptive fault tolerance strategy for cloud storage

  • Xiai, Yan;Dafang, Zhang;Jinmin, Yang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.11
    • /
    • pp.5290-5304
    • /
    • 2016
  • With the growth of the massive amount of data, the failure probability of the cloud storage node is becoming more and more big. A single fault tolerance strategy, such as replication and erasure codes, has some unavoidable disadvantages, which can not meet the needs of the today's fault tolerance. Therefore, according to the file access frequency and size, an adaptive hybrid redundant fault tolerance strategy is proposed, which can dynamically change between the replication scheme and erasure codes scheme throughout the lifecycle. The experimental results show that the proposed scheme can not only save the storage space(reduced by 32% compared with replication), but also ensure the fast recovery of the node failures(increased by 42% compared with erasure codes).