• Title/Summary/Keyword: Strain difference function

Search Result 73, Processing Time 0.029 seconds

In-situ Stress Measurement Using AE and DRA (AE와 DRA를 이용한 초기응력의 측정에 관한 연구)

  • Park, Pae-Han;Jeon, Seok-Won;Kim, Yang-Kyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.1
    • /
    • pp.51-62
    • /
    • 2001
  • In-situ stress measurement using AE (Acoustic Emission) and DRA (Deformation Rate Analysis) is usually carried out under uniaxial loading in the laboratory and it consumes delay time from drilling to testing. Therefore, it should be considered how the lateral stress and delay time influence on the test results for the in-situ stress determination. As the delay time increased, the accuracy of estimating the pre-stress decreased. The pre-stress of the specimen loaded only axially was determined within an error of less than 9% (using AE) and 4% (using DRA). And the specimen on which axial pre-stress and the confining pressure were loaded had an error of less than 17% (using AE) and 14% (using DRA). The results of AE and DRA for field specimens were very similar with each other but smaller than those of hydraulic fracturing method.

  • PDF

Retentive Force of Adjustable Dental Impression Trays with Different Synthetic Resin Materials (합성수지 재료에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구)

  • Lee, In-Seob;Lee, jin-Han;Kim, Yu-Lee;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.1
    • /
    • pp.11-21
    • /
    • 2006
  • The adjustable dental impression trays were made for being adjusted their width automatically along the width of patient's dental arch. The purpose of this study was to investigate the retentive force of adjustable dental impression trays made of different synthetic resin materials. Three pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) synthetic resin, polyurethane synthetic resin and polycarbonate synthetic resin with a hole and without a rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray jig which was made for holding the tray on the lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the alginate impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum force by use of UTM at a constant strain rate 100mm per minute. The results obtained in this study were as follows : 1. The upper trays were showed higher retentive force than lower trays in three tray materials. 2. There was no significant difference in the retentive force of the tray materials(p>0.05).

Thermal stability analysis of solar functionally graded plates on elastic foundation using an efficient hyperbolic shear deformation theory

  • El-Hassar, Sidi Mohamed;Benyoucef, Samir;Heireche, Houari;Tounsi, Abdelouahed
    • Geomechanics and Engineering
    • /
    • v.10 no.3
    • /
    • pp.357-386
    • /
    • 2016
  • In this research work, an exact analytical solution for thermal stability of solar functionally graded rectangular plates subjected to uniform, linear and non-linear temperature rises across the thickness direction is developed. It is assumed that the plate rests on two-parameter elastic foundation and its material properties vary through the thickness of the plate as a power function. The neutral surface position for such plate is determined, and the efficient hyperbolic plate theory based on exact neutral surface position is employed to derive the governing stability equations. The displacement field is chosen based on assumptions that the in-plane and transverse displacements consist of bending and shear components, and the shear components of in-plane displacements give rise to the quadratic distribution of transverse shear stress through the thickness in such a way that shear stresses vanish on the plate surfaces. Therefore, there is no need to use shear correction factor. Just four unknown displacement functions are used in the present theory against five unknown displacement functions used in the corresponding ones. The non-linear strain-displacement relations are also taken into consideration. The influences of many plate parameters on buckling temperature difference will be investigated. Numerical results are presented for the present theory, demonstrating its importance and accuracy in comparison to other theories.

A Study On The Bending Characteristics of Ribbon Cable Unit (리본광케이블 유니트의 구부림 특성 연구)

  • 이병철;이영탁;김미경
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.379-384
    • /
    • 1995
  • In order to construct B-ISDN, it is inevitable to introduce optical fiber of low loss and wide bandwidth. Coincidently, high count optical fiber cable is solely important to form optical subscriber network. The best structure of high count optical fiber cable to achieve multi-splicing as well as high density at the same time is the one of taking optical ribbon as a unit of accomodation. However, since optical ribbon has its own width. optical loss due to length difference during the bending of ribbon cable unit occurs in relatively easy way. Therefore, care should be taken during its manufacturing and storage. In t\1::; paper, strain, bending radius and lateral pressure of each fiber in ribbon due to the bending of ribbon cable unit are caculated theoretically. Hence, we have measured optical loss of each fiber as function of unit bending radius, when we bent the ribbon cable unit on the various reel. We found that the result accords well with the theoretical analysis. The result shows the importance to determine proper radius of reel used in ribbon cable manufacturing and storage. orage.

  • PDF

Determination of Flow Stress of Zircaloy-4 Under High Strain Rate Using Slot Milling Test (슬롯밀링시험을 이용한 높은 변형률 속도 조건하에서 Zircaloy-4의 유동응력 결정)

  • Hwang, Jihoon;Kim, Naksoo;Lee, Hyungyil;Kim, Dongchoul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.67-75
    • /
    • 2013
  • The flow stress of zircaloy-4 used in the spacer grid supporting a nuclear fuel rod was determined by the Johnson-Cook model, and model parameters were determined using reverse engineering. Parameters such as A, B, n and $\dot{\varepsilon}_0$ were determined by the tensile test result. To obtain the parameters C and m, a slot milling test and numerical simulation were performed. The objective functions were defined as the difference between the experimental and the simulation results, and then, the parameters were determined by minimizing the objective function. To verify the validity of the determined parameters, cross-verification for each case was conducted through a shearing test and simulation. The results tend to show agreement with the experimental results, such as the features of sheared edges and maximum punch force, with the correlation coefficients exceeding at least 0.97.

Algorithms for Ultrasound Elasticity Imaging (초음파 탄성 영상 알고리듬)

  • Kwon, Sung-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.484-493
    • /
    • 2012
  • Since the 1980s, there have been many research activities devoted to quantitatively characterizing and imaging human tissues based on sound speed, attenuation coefficient, density, nonlinear B/A parameter, etc., but those efforts have not yet reached the stage of commercialization. However, a new imaging technology termed elastography, which was proposed in the early 1980s, has recently been implemented in commercial clinical ultrasound scanners, and is now being used to diagnose prostates, breasts, thyroids, livers, blood vessels, etc., more quantitatively as a complementary adjunct modality to the conventional B-mode imaging. The purpose of this article is to introduce and review various elastographic algorithms for use in quasistatic or static compression type elasticity imaging modes. Most of the algorithms are based on the crosscorrelation or autocorrelation function methods, and the fundamental difference is that the time shift is estimated by changing the lag variable in the former, while it is directly obtained from the phase shift at a fixed lag in the latter.

Deformation and permeability evolution of coal during axial stress cyclic loading and unloading: An experimental study

  • Wang, Kai;Guo, Yangyang;Xu, Hao;Dong, Huzi;Du, Feng;Huang, Qiming
    • Geomechanics and Engineering
    • /
    • v.24 no.6
    • /
    • pp.519-529
    • /
    • 2021
  • In coal mining activities, the abutment stress of the coal has to undergo cyclic loading and unloading, affecting the strength and seepage characteristics of coal; additionally, it can cause dynamic disasters, posing a major challenge for the safety of coal mine production. To improve the understanding of the dynamic disaster mechanism of gas outburst and rock burst coupling, triaxial devices are applied to axial pressure cyclic loading-unloading tests under different axial stress peaks and different pore pressures. The existing empirical formula is use to perform a non-linear regression fitting on the relationship between stress and permeability, and the damage rate of permeability is introduced to analyze the change in permeability. The results show that the permeability curve obtained had "memory", and the peak stress was lower than the conventional loading path. The permeability curve and the volume strain curve show a clear symmetrical relationship, being the former in the form of a negative power function. Owing to the influence of irreversible deformation, the permeability difference and the damage of permeability mainly occur in the initial stage of loading-unloading, and both decrease as the number of cycles of loading-unloading increase. At the end of the first cycle and the second cycle, the permeability decreased in the range of 5.777 - 8.421 % and 4.311-8.713 %, respectively. The permeability decreases with an increase in the axial stress peak, and the damage rate shows the opposite trend. Under the same conditions, the permeability of methane is always lower than that of helium, and it shows a V-shape change trend with increasing methane pressures, and the permeability of the specimen was 3 MPa > 1 MPa > 2 MPa.

Comparison of Effect of Hip-dominant vs Knee-dominant Hamstring Strengthening Exercises on the Muscle Strength, Range of Movement, and Functional Performance Level: A Randomized Intervention Trial (엉덩관절-우세 넙다리뒤근 운동과 무릎관절-우세 넙다리뒤근 운동이 넙다리뒤근 근력과 관절가동범위, 기능적 수행 수준에 미치는 영향 비교: 무작위 중재 시험)

  • Hyun Kim;Jin-taek Kim;Suhn-yeop Kim
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.30 no.2
    • /
    • pp.13-26
    • /
    • 2024
  • Background: The most common form of injury in soccer is a hamstring strain. Eccentric bias exercises are crucial for reducing injury risk and improving sprinting performance. The purpose of this study was to compare a 4-week hip-dominant hamstring strengthening exercise program (HDE) with a knee-dominant hamstring strengthening exercise program (KDE) in youth soccer players. Method: The sample (n=31) was randomly divided into two groups: HDE (n=17) and KDE (n=14), with soccer players in HDE performing hip joint-dominant hamstring strengthening exercises and those in KDE performing knee joint-dominant hamstring strengthening exercises. Each intervention was conducted three times per week for four weeks. The outcome measures included the hamstring strength test (isometric strength test, eccentric strength test), knee joint range of motion (90/90 active knee extension; AKE) test, lower limb function test Y-balance test and Agility T-test. Results: Following the intervention, both groups showed significant improvement in isometric and eccentric hamstring strength on both dominant and non-dominant sides (p<.05). The AKE test showed significant improvement in the dominant leg (p<.05) and non-dominant leg only in KDE. The agility test significantly improved in HDE (p<.05). There was a slight improvement in the Y-balance test score; however, the difference was not statistically significant. There were no differences between the two groups in the values before, and after the intervention for all items. Conclusion: The hip-dominant and knee-dominant hamstring strengthening exercise should be coordinated and used based on the environment during hamstring injury prevention training.

  • PDF

A Study on the Small Punch Test for Fracture Strength Evaluation of CANDU Pressure Tube Embrittled by Hydrogen (수소취화된 CANDU 압력관 재료의 파괴강도 평가를 위한 SP시험에 관한 연구)

  • Nho, Seung-Hwan;Ong, Jang-Woo;Yu, Hyo-Sun;Chung, Se-Hi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.4
    • /
    • pp.549-560
    • /
    • 1996
  • The purpose of this study is to investigate the usefulness of small punch(SP) test using miniaturized specimens as a method for fracture strength evaluation of CANDU pressure tube embrittled by hydrogen. According to the test results, the fracture strength evaluation as a function of hydrogen concentration at $-196^{\circ}C$ was much better than that at room temperature, as the difference of SP fracture energy(Esp) with hydrogen concentration was more significant at $-196^{\circ}C$ than at room temperature for the hydrogen concentration up to 300ppm-H. It was also observed that the peak of average AE energy, the cumulative average AE energy and the cumulative average AE energy per equivalent fracture, strain increased with the increase of hydrogen concentration. From the results of load-displacement behaviors, Esp behaviors, macro- and micro-SEM fractographs and AE test it has been concluded that the SP test method using miniaturized specimen($10mm{\times}10mm{\times}0.5mm$) will be a useful test method to evaluate the fracture strength for CANDU pressure tube embrittled by hydrogen.

  • PDF

Mutation Analysis of Synthetic DNA Barcodes in a Fission Yeast Gene Deletion Library by Sanger Sequencing

  • Lee, Minho;Choi, Shin-Jung;Han, Sangjo;Nam, Miyoung;Kim, Dongsup;Kim, Dong-Uk;Hoe, Kwang-Lae
    • Genomics & Informatics
    • /
    • v.16 no.2
    • /
    • pp.22-29
    • /
    • 2018
  • Incorporation of unique barcodes into fission yeast gene deletion collections has enabled the identification of gene functions by growth fitness analysis. For fine tuning, it is important to examine barcode sequences, because mutations arise during strain construction. Out of 8,708 barcodes (4,354 strains) covering 88.5% of all 4,919 open reading frames, 7,734 barcodes (88.8%) were validated as high-fidelity to be inserted at the correct positions by Sanger sequencing. Sequence examination of the 7,734 high-fidelity barcodes revealed that 1,039 barcodes (13.4%) deviated from the original design. In total, 1,284 mutations (mutation rate of 16.6%) exist within the 1,039 mutated barcodes, which is comparable to budding yeast (18%). When the type of mutation was considered, substitutions accounted for 845 mutations (10.9%), deletions accounted for 319 mutations (4.1%), and insertions accounted for 121 mutations (1.6%). Peculiarly, the frequency of substitutions (67.6%) was unexpectedly higher than in budding yeast (~28%) and well above the predicted error of Sanger sequencing (~2%), which might have arisen during the solid-phase oligonucleotide synthesis and PCR amplification of the barcodes during strain construction. When the mutation rate was analyzed by position within 20-mer barcodes using the 1,284 mutations from the 7,734 sequenced barcodes, there was no significant difference between up-tags and down-tags at a given position. The mutation frequency at a given position was similar at most positions, ranging from 0.4% (32/7,734) to 1.1% (82/7,734), except at position 1, which was highest (3.1%), as in budding yeast. Together, well-defined barcode sequences, combined with the next-generation sequencing platform, promise to make the fission yeast gene deletion library a powerful tool for understanding gene function.