• 제목/요약/키워드: Strain Gauge

검색결과 574건 처리시간 0.032초

잉크젯 인쇄기술을 이용한 종이 스트레인게이지 개발 (Development of a Paper Strain Gauge using Inkjet-printing Technology)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제14권2호
    • /
    • pp.23-27
    • /
    • 2015
  • In this paper, eco-friendly paper strain gauge was fabricated in the way of printing strain gauge on paper substrate, using PEDOT:PSS ink and inkjet printer technology. As a p-type conductive high polymer, PEDOT:PSS is known to be piezoresistive effect. I formed a strain gauge by connecting in parallel 5 lines of $60{\mu}m$ width printed with PEDOT:PSS. To minimize surrounding influence such as temperature, I formed wheat-stone bridge by combining 4 strain gauges (quarter-bridge strain gauge) which were made up of PEDOT:PSS 5 lines and measured. In quarter-bridge strain gauge, only two strain gauges, facing each other, arranged in strain and horizontal direction were deformed while the other two strain gauge of vertical direction were not. Therefore, quarter-bridge strain gauge showed the output of half bridge. The fabricated quarter-bridge strain gauge had output sensitivity of $105.6{\mu}V/V{\cdot}mm$ and its output linearity was relatively good.

대 변형 감지용 스트레인게이지 개발 (Development of a Strain Gauge for Sensing Large Strain)

  • 이영태;조승우
    • 반도체디스플레이기술학회지
    • /
    • 제13권4호
    • /
    • pp.33-36
    • /
    • 2014
  • In this paper, a carbon strain gauge for large strain was developed. The carbon strain gauge was fabricated by forming PCB and antenna pattern using Cu/Ni/Au film and carbon resistor pattern using screen printing process on plastic film substrate. It was possible to develop low-cost disposable strain gauge since the carbon paste was cheap and the fabrication process was simple. The wireless communication type carbon strain gauge was fabricated by integrating signal processing circuit, antenna and power all together on the same substrate as a strain gauge. The wireless communication type carbon strain gauge has a merit of being available immediately at the spot without any particular system.

단일모드 광섬유 Mach-Zehnder 간섭계를 이용한 광섬유 스트레인 게이지의 동적 특성 (Dynamical Characteristics of a Fiber-Optic Strain Gauge by a Single-Mode Fiber-Optic Mach-Zehnder Interferometer)

  • 이기완;홍봉식
    • 대한전자공학회논문지
    • /
    • 제27권5호
    • /
    • pp.793-801
    • /
    • 1990
  • A single mode fiber-optic Mach-Zehnder interferometer for the measurement of strain is described. A fiber-optic strain gauge with great resolution and wide measurement range is realized. In order to varify the dynamic response, the measurements of strain below 1涅 with frequency range 5-50Hz are compared with a semiconductor strain gauge. We report theoretical evaluation for mechanical analysis, PZT-plate, the phase change in a fiber-optic strain gauge and a semiconductor strain gauge. The dynamical characteristics of a fiber-optic strain gauge and a semiconductor strain gauge output siganl show equivalent behavior. This result is shown in very good usage as the dynamical measurement of the low strain below 1涅 by this system.

  • PDF

금속 외팔보에 접착된 박막 실리콘 스트레인 게이지의 제작 및 성능 평가 (Fabrication and Performance Evaluation of Thin Polysilicon Strain Gauge Bonded to Metal Cantilever Beam)

  • 김용대;김영덕;이철섭;권세진
    • 대한기계학회논문집A
    • /
    • 제34권4호
    • /
    • pp.391-398
    • /
    • 2010
  • 금속은 가공성이 우수하기 때문에 다양한 형태의 구조물이나 격막을 제작할 수 있다. 이런 금속 구조물이나 격막에 민감도가 월등히 우수한 실리콘 스트레인 게이지를 적용할 경우 그 응용 범위가 다양해질 수 있다. 이에 금속구조물에 다결정 실리콘 스트레인 게이지를 접착한 형태의 센서를 제안하였다. 실리콘 기판을 이용해 박막형 다결정 실리콘 스트레인 게이지를 제작하기 위한 제작공정을 확립하였으며, 제작된 실리콘 스트레인 게이지를 금속 변형부 위에 접착하기 위한 접착공정을 확립하였다. 이후 금속 외팔보에 실리콘 스트레인 게이지를 글래스 프릿 접착하여 성능평가를 실시하였다. 성능평가 결과 게이지팩터는 34.0 의 값을 가졌으며, TCR(Temperature Coefficient of Resistance)은 $-328\;ppm/^{\circ}C$의 값을 가졌다.

댐 거동 분석에서의 Strain Gauge를 이용한 단일 계측에 관한 연구 (The Study on the Simple Measurement by Using the Strain Gauge at Dam Dynamic Behavior Analysis)

  • 이승호
    • 한국지반환경공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.5-11
    • /
    • 2007
  • 담수시 저수되는 수압에 의해 face slab con'c 내부의 응력변화가 발생하여 댐 제체의 안정성에 영향을 미칠 가능성이 있으므로 face slab con'c의 내부 응력변화를 측정하기 위하여 매립형 strain gauge가 많이 적용되고 있다. 따라서 본 연구에서는 ${\circ}{\circ}$댐에 적용된 strain gauge를 이용하여 댐 제체 내 외부 변형을 측정하였다. 그 결과 댐의 안정성 분석과 전체적인 경향을 파악함에 있어서 strain gauge의 계측 값만으로는 한계가 있으므로 관련 계기의 측정값을 함께 검토해야 할 것으로 사료된다.

  • PDF

단일 모-드 광섬유 스트레인 게이지 (Single-mode optical fiber strain gauge)

  • 이기완;김병교
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1198-1203
    • /
    • 1991
  • A single w& optical fiber strain gauge subjected to the excited PZT-plate is presented which was obtained using a Mach-Zehnder interferometer. This paper has been performed the considerations to the experimental situation In which the dynamical behavior of a optical fiber strain gauge is illustrated. A comparison is reported between the dynamic response of a optical fiber strain gauge and the semiconductor strain gauge in the frequency range 5-50Hz. This result is shown in very good usage as the dynamical measurement of the low strain below l.mu..epsilon. by this system.

  • PDF

블레이드 진동측정을 위한 스트레인 게이지 설치위치 최적화 (Optimal Placement of Strain Gauge for Vibration Measurement for Fan Blade)

  • 최병근
    • 한국소음진동공학회논문집
    • /
    • 제14권9호
    • /
    • pp.819-826
    • /
    • 2004
  • A multi-step optimum strategy for the selection of the locations and directions of strain gauges is proposed in this paper to capture at best the modal response of blade in a series of modes on fan blades. It is consist of three steps including two pass reduction step, genetic algorithm and fine optimization to find the locations-directions of strain gauges. The optimization is based upon the maximum signal-to-noise ratio(SNR) of measured strain values with respect to the inherent system measurement noise, the mispositioning of the gauge in location and gauge failure. Optimal gauge positions for a fan blade is analyzed to prove the effectiveness of the multi-step optimum methodology and to investigate the effects of the considering parameters such as the mispositioning level, the probability of gauge failure, and the number of gauges on the optimal strain gauge position.

Anchor 볼트형태의 strain gauge 센서모듈설계 (Implementation of Anchor Bolt Type Strain Gauge Sensor Module)

  • 곽재민;임춘식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.421-422
    • /
    • 2019
  • 본 논문에서는 산업현장에서 안전사고 빈도가 높은 지게차 전복에 대비하여 적재중량을 측정하기 위해 적용할 수 있는 strain gauge 센서 모듈구현 결과를 제시한다. 센서 모듈은 strain gauge, LNA, LPF 및 ADC로 구성하였으며, 센서의 측량정밀도와 내구성을 높이기 위해 4개의 센서가 각각 4개의 anchor bolt에 삽입되는 구조로 제작하였다.

  • PDF

진동측정을 위한 스트레인 게이지 설치위치 최적화 : 최적화 방법 및 평가 (Optimal Placement of Strain Gauge for Vibration Measurement : Formulation and Assessment)

  • 최창림;양보석;최병근
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.757-766
    • /
    • 2004
  • This paper focuses on the formulation and validation of an automatic strategy to select the optimal location and direction of strain gauges for the measurement of the modal response. These locations and directions are important to render the strain measurements as robust as possible when a random mispositioning of the gauges and gauge failures are expected. The approach relies on the evaluation of the signal-to-noise ratios of the gauge measurements from strain data of finite element. The multi-step optimization strategy including genetic algorithm is used to find the strain gauge locations-directions that maximize the smallest modal strain signal-to-noise ratio in the absence of gauge failure or its expected value when gauge failure is possible. A flat Plate is used to prove the applicability of the proposed methodology and to demonstrate the effects of the essential parameters of the problem such as the mispositioning level, the probability of gauge failure, and the number of gauges.

Position Optimization of Strain Gauge on Blades

  • Choi, Byeong-Keun;Lee, Hyun-Seob;Yang, Bo-Suk;Mignolet, Marc P.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.422-427
    • /
    • 2002
  • This paper focuses on the formulation and validation of an automatic strategy for the selection of the locations and directions of strain gauges to capture at best the modal response of a blade in a series of modes. These locations and directions are selected to render the strain measurements as robust as possible with respect to random mispositioning of the gauges and gauge failures. The approach relies on the evaluation of the signal-to-noise ratios of the gauge measurements from finite element strain data and includes the effects of gauge size. A genetic algorithm is used to find the strain gauge locations-directions that lead to the largest possible value of the smallest modal strain signal-to-noise ratio, in the absence of gauge failure, or of its expected value when gauge failure is possible. A fan blade is used to exemplify the applicability of the proposed methodology and to demonstrate the effects of the essential parameters of the problem, i.e. the mispositioning level, the probability of gauge failure, and the number of gauges.

  • PDF