• Title/Summary/Keyword: Straight configuration

Search Result 76, Processing Time 0.02 seconds

Effects of blade configuration and solidity on starting torque of Darrieus wind turbine

  • Roh, Sung-Cheoul;Kang, Seung-Hee
    • Wind and Structures
    • /
    • v.32 no.2
    • /
    • pp.169-177
    • /
    • 2021
  • This study investigates the effects of blade configuration and solidity of Darrieus wind turbine on the starting torque characteristics. Generally, the configuration of Darrieus wind turbine is divided into Troposkien, parabola, Catenary, Sandia, modified-parabola and straight types. A numerical analysis has been carried out using Multiple Stream Tube (MST) method to investigate the effect of blade configuration and solidity of Darrieus wind turbine on the starting torque under the initial low range of rotational speed. The simulation results show that the starting torque of Darrieus wind turbine varies considerably depending on the blade configuration. The initial starting torque was larger with Troposkien, Parabola, Catenary, and Sandia configurations than with modified parabola or straight types. The increase in solidity with increasing number of blades raised the starting torque and improved the dynamic stability during the initial operational speed of Darrieus wind turbine. Additionally, these torque results represent basic data for fluid-structure interaction (FSI) simulation of the steady-dynamic operation of the turbine.

PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION (하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석)

  • Cho Hye-Won;Kim Nan-Young;Kim Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

The Heat Transfer and Pressure Drop Characteristics on Microchannel PCHE with various Configurations (채널 형상에 따른 마이크로채널 PCHE의 열전달 및 압력강하 특성)

  • Kim, Yoon-Ho;Moon, Jung-Eun;Lee, Kyu-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.215-220
    • /
    • 2008
  • A microchannel PCHE is manufactured by the two technologies of micro photo-etching and diffusion bonding. In this paper, heat transfer and pressure drop characteristics by applying various configuration for the flow channel in the microchannel PCHE is experimentally investigated. The flow channel configurations are designed three types such as straight, wavy and offset strip channels. The performance experiment of each configuration is performed for Reynolds numbers in ranges of $100{\sim}700$ under various flow conditions for the hot side and the Reynolds number of cold side is fixed at 350. The inlet temperatures of the hot side and cold side are conducted as $40^{\circ}C$ and $20^{\circ}C$, respectively. The heat transfer performance of wavy channel, which was similar to that of offset strip channel, was much higher than that of straight channel. The effectiveness of wavy channel and offset strip channel was evaluated as about $0.5{\sim}0.9$. The pressure drop of wavy channel was highest among configurations and that of offset strip channel was lower than that of straight channel because the round curved surface of each strip edge was reduced the pressure loss.

  • PDF

THE CANAL SYSTEM OF MANDIBULAR INCISORS (하악 절치의 근관계에 관한 연구)

  • Rhim, Eun-Mi;Choi, Ho-Young;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.432-440
    • /
    • 2002
  • The purpose of this study is to identificate root canal system including ideal access placement, root curvature, canal configuration, incidence of isthmus in mandibular incisors for success of endodontic treatment. 200 mandibular incisors were selected. The ideal access placement was determimed as follows. The teeth there radiographed from mesiodistal and buccolingual views using intraoral dental film. The image was divided into coronal, middle and apical third using the proximal film. Straight line access was determined by measuring the faciolingual canal width and placing points at midway point between the buccal and lingual wall at the junction of the middle and apical third and at the juntion of coronal and middle third of the root canal. A line was drawn connecting these two points extending through the crown of the tooth. The point at which the line crossed the external crown surface was recorded as facial, incisal, lingual. Degree of root curvature was determined by Schneider Protractor Method. Both section method and clearing method were used in this study. By section method, 100 mandibular incisors were embedded in clear resin and transeverse serial sectioned at 0.5, 1.0, 2.0, 3.0, 4.0, 5.0mm level from root apex. The resected surfaces were stained by methylene blue and examined under $\times$40 magnification with a stereomicroscope. By clearing method, 100 mandibular incisors were cleared in methysalicylate after decalcification with 10% nitric acid and evaluated under $\times$18 magnification with a stereomicroscope. The results were as follows ; 1. 29% had the center of the plotted straight-line access facial to incisal edge, whereas 71% had straight-line access at the incisal edge. When incisal wear classified as extensive, the straight-line access was plotted on the incisal edge 95.5%. When incisal wear classified as slight/none, the straight-line access was plotted on the facial 65.9%. 2. Degree of curvature of main canal was straight or almost straight, and only 10% in buccolingual direction had a degree of curvature greater than 20 degrees and 5.5% in mesiodistal direction had. 3. In section method, canal configuration analysis showed that 51% of the specimen classified as type I, 27% as type II, 12% as type III, 10% as type IV. For theses setions with two canals, the incidence of an isthmus was 36.7%, 64.3%, 79.2%, 96.3%, 97.4%, 97.6% at each level and highest in 3~5mm sections. 4. In clearing method, canal configuration analysis showed that 74% of the specimen classified as type I, 11% as type II, 6% as type III, 9% as type IV. These results suggested that traditional access from lingual should be moved as far toward the incisal as possible to locate and debride the lingual canal and root canal system should be cleaned, shaped completely and obturated three dimensionally for successful endodontic treatment.

Aerodynamic Performance of a Wind-Turbine Affected by Blade Configuration (브레이드 외형(外形)이 풍력(風力) 터어빈의 공력(空力) 성능(性能)에 미치는 영향)

  • Son, Byung-Chan
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.86-92
    • /
    • 1986
  • This paper presents the aerodynamic performances of horizontal axis wind turbines with non-twisted but taperd blades. Five configurations of blades, namely, one straight blade and four tapered blades with taper ratio of ranging from 0.1 to 0.7 have been simulated. The aerodynamic performances of the wind turbines have been determined over blade incidence angle of ranging from $2^{\circ}$ to $6^{\circ}$ and keeping same solidity and radius of them. The results are presented comparing straight blade from four tapered blades for maximum power coefficient and tip looses against variation of taper ratio. It also shows that the wind turbine with taper ratio of 0.5 has the highest maximum power coefficient than others. And wind turbines with taper ratio below 0.2 have lower values of maximum power coefficients than straight one. The tip loss of straight blade is the largest and reduces Slightly with the decrementation of taper ratio.

  • PDF

Toroidal Equilibrium of Screw Belt Pinch

  • Kim, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.249-252
    • /
    • 1974
  • The equilibrium configuration of the screw belt pinch is obtained as the first-order correction on that of the straight pinch of infinite lenghth.

  • PDF

Calculation and Mitigation of Magnetic Field Produced by Straight Line-Conductor with Finite Length (유한장 직선도체에 의한 자계의 계산 및 감소대책)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.57-67
    • /
    • 2011
  • Purpose of this study is to find the mitigation method of magnetic field by finite length multi-conductors such as indoor distribution lines and to be applicable to design of the distribution lines. For this purpose, exact formula about the components $B_x$, $B_y$, $B_z$ of magnetic field need in case of straight line-conductor with finite length forward any direction. In this study simple formula of the components were deduced and by using these formula magnetic fields for various models of line-configurations were calculated. And also a calculation method of induced currents in conductive shield was presented and using this method, programing of calculation is relatively easy and calculation time is short. The magnetic field after cancellation by these induced currents was calculated. All of calculations were performed by Matlab 7.0 programs. Through the calculation results it could be obtained followings for the mitigation of magnetic fields. The separation between conductors ought to be smaller than smaller as possible. In case of 3-phase, delta configuration is more effective than flat configuration. In case of 3-phase, unbalanced currents ought to be reduced as possible.. In case of more than two circuits of 3-phase, adequate locations of each phase-conductor such as rotating configuration of 3-phase conductors are more effective. The magnetic shielding effect of the conductive shielding sheet is very high.

ROAD CROWN, TIRE, AND SUSPENSION EFFECTS ON VEHICLE STRAIGHT-AHEAD MOTION

  • LEE J-H.;LEE J. W.;SUNG I. C.
    • International Journal of Automotive Technology
    • /
    • v.6 no.2
    • /
    • pp.183-190
    • /
    • 2005
  • During normal operating conditions, a motor vehicle is constantly subjected to a variety of forces, which can adversely affect its straight-ahead motion performance. These forces can originate both from external sources such as wind and road and from on-board sources such as tires, suspension, and chassis configuration. One of the effects of these disturbances is the phenomenon of vehicle lateral-drift during straight-ahead motion. This paper examines the effects of road crown, tires, and suspension on vehicle straight-ahead motion. The results of experimental studies into the effects of these on-board and external disturbances are extremely sensitive to small changes in test conditions and are therefore difficult to guarantee repeatability. This study was therefore conducted by means of computer simulation using a full vehicle model. The purpose of this paper is to gain further understanding of the straight-ahead maneuver from simulation results, some aspects of which may not be obtainable from experimental study. This paper also aims to clarify some of the disputable arguments on the theories of vehicle straight-ahead motion found in the literature. Tire residual aligning torque, road crown angle, scrub radius and caster angle in suspension geometry, were selected as the study variables. The effects of these variables on straight-ahead motion were evaluated from the straight-ahead motion simulation results during a 100m run in free control mode. Examination of vehicle behavior during straight-ahead motion under a fixed control mode was also carried out in order to evaluate the validity of several disputable arguments on vehicle pull theory, found in the literature. Finally, qualitative comparisons between the simulation results and the test results were made to support the validity of the simulation results.

Study on the Design of Thin Intersected Axe Gear (박육직교축 치차의 설계에 관한 기초적 연구)

  • ;梅澤 淸彦
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.80-87
    • /
    • 1993
  • The various configuration of thin-shaped bevel gears are used usually for such as main reduction gear of the hovercraft. But the reasonable and concise guide to thedesign of the se bevel gears is not yet obtained, since the tooth of bevel gear has complex form. The purpose of these investigation is to be establish the design guide and to propose the desirable configuration form for thin-shaped straight bevel gear. In this report, the desirable configuration is examined experimentally by clearing up the effect of web and rim thickness, rim support condition upon the load distribution and root stress distribution along the tooth trace. The results are summarized as follows. (1) The crowning of tooth trace exerts a significant effect on the root stress distribution of thin-shaped bevel gear. (2) As the desirable configuration of the thin-shaped bevel gear, it is to be recommended that the rim is supported at the heel side of tooth trace. (3) But, as special type, it is desirable that the rim is supported at the toe side.

  • PDF

Performance Enhancement of a PEMFC by Modification of Air Inlet Flow Header Configuration (공기측 입구헤더의 형상 개선을 통한 고분자 전해질 연료전지의 성능 향상)

  • Kim, Won-Nyun;Kim, Yun-Ho;Kim, Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.339-345
    • /
    • 2007
  • In the present study, a 10-cell PEMFC stack with straight type cathode flow channels is employed to investigate the effect of inlet air flow header configuration on the overall fuel cell performance. Four different types of inlet flow headers are considered and the flow patterns according to the air inlet flow header configuration are numerically obtained. The computed result for a modified header predicts about 8.5% improvement in the air flow distribution at 10-cell cathode channel inlets. Experiments are also carried out to confirm the numerical findings by measuring actual air flow distributions and the polarization curves of the PEMFC stack.