• Title/Summary/Keyword: Straight Ray Technique

Search Result 8, Processing Time 0.026 seconds

Seismic Reflection Tomography by Cell Parameterization (셀 매개변수에 의한 탄성파 반사주시 토모그래피)

  • Seo, Young-Tak;Shin, Chang-Soo;Ko, Seung-Won
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.2
    • /
    • pp.95-100
    • /
    • 2003
  • In this study, we developed reflection tomography inversion algorithm using Straight Ray Technique (SRT) which can calculate travel time easily and fast for complex geological structure. The inversion process begins by setting the initial velocity model as a constant velocity model that hat only impedance boundaries. The inversion process searches a layer-interface structure model that is able to explain the given data satisfactorily by inverting to minimize data misfit. For getting optimal solution, we used Gauss-Newton method that needed constructing the approximate Hessian matrix. We also applied the Marquart-Levenberg regularization method to this inversion process to prevent solution diverging. The ability of the method to resolve typical target structures was tested in a synthetic salt dome inversion. Using the inverted velocity model, we obtained the migration image close to that of the true velocity model.

Ferroelectric Domans in $BaTiO_3$ ($BaTiO_3$의 강유전성 분역)

  • 박봉모;정수진
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.1
    • /
    • pp.56-64
    • /
    • 1996
  • A large amount of papers about the cubic-to-tetragonal phase transition the ferroelectric domain structures of the BaTiO3 were already reported but there exist still some needs to observe the domain behaviors directly. In this study the domain structures of the tinned plates prepared from ta single crystal grown by the TSSG technique were observed using a polarizing microscope TE and X-ray topography. The spatial relation be-tween the orientation states of domains was investigated and the effects of external stresses and electric fields on the behaviors of ferroelectric and ferroelastic domains were studied. All the 90$^{\circ}$walls cut off in the crystal are the wedge shaped lamellar domains and all the straight boundaries in the observed domain patte군 can be interpreted as the head-to-tail 90$^{\circ}$walls. The irregular overlapped boundaries commonly observed by using a polarizing microscope and X-ray topography are complex combinations of well-known 90$^{\circ}$walls and are domain walls were predominant and were stabilized after surface polishing. In the paraelectric phase region the domain walls vanished but the residual surface strain patterns could be seen at the same positions of the stabilized 90$^{\circ}$a-a walls in the tetragonal phase region, These stabilized walls resulted from the surface strain had a memory effect in domain formation during the repeated phase transitions and could notr be affected by an external electtric field.

  • PDF

Application of Ultrasound Tomography for Non-Destructive Testing of Concrete Structure (초음파 tomography를 응용한 콘크리트 구조물의 비파괴 시험에 관한 연구)

  • Kim, Young-Ki;Yoon, Young-Deuk;Yoon, Chong-Yul;Kim, Jung-Soo;Kim, Woon-Kyung;Song, Moon-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.1
    • /
    • pp.27-36
    • /
    • 2000
  • As a potential approach for non-destructive testing of concrete structures, we evaluate the time-of-flight (TOF) ultrasound tomography technique In conventional X ray tomography, the reconstructed Image corresponds to the internal attenuation coefficient However, in TOF ultrasound tomography, the reconstructed Image is proportional to the retractive index of the medium Because refractive effects are minimal for X-rays, conventional reconstruction techniques are applied to reconstruct the Image in X-ray tomography However, since ultrasound travels in curved path, due to the spatial variations in the refractive index of the medium, the path must be known to correctly reconstruct the Image. Algorithm for determining the ultrasound path is developed from a Geometrical Optics point view and the image reconstruction algorithm, since the paths are curved It requires the algebraic approach, namely the ART or the SIRT Here, the difference between the computed and the measured TOP data is used as a basis, for the iteration process First the initial image is reconstructed assuming straight paths. It then updates the path based on the recently reconstructed image This process of reconstruction and path determination repeats until convergence The proposed algorithm is evaluated by computer simulations, and in addition is applied to a real concrete structure.

  • PDF

Review of Acute Traumatic Closed Mallet Finger Injuries in Adults

  • Botero, Santiago Salazar;Diaz, Juan Jose Hidalgo;Benaida, Anissa;Collon, Sylvie;Facca, Sybille;Liverneaux, Philippe Andre
    • Archives of Plastic Surgery
    • /
    • v.43 no.2
    • /
    • pp.134-144
    • /
    • 2016
  • In adults, mallet finger is a traumatic zone I lesion of the extensor tendon with either tendon rupture or bony avulsion at the base of the distal phalanx. High-energy mechanisms of injury generally occur in young men, whereas lower energy mechanisms are observed in elderly women. The mechanism of injury is an axial load applied to a straight digit tip, which is then followed by passive extreme distal interphalangeal joint (DIPJ) hyperextension or hyperflexion. Mallet finger is diagnosed clinically, but an X-ray should always be performed. Tubiana's classification takes into account the size of the bony articular fragment and DIPJ subluxation. We propose to stage subluxated fractures as stage III if the subluxation is reducible with a splint and as stage IV if not. Left untreated, mallet finger becomes chronic and leads to a swan-neck deformity and DIPJ osteoarthritis. The goal of treatment is to restore active DIPJ extension. The results of a six- to eight-week conservative course of treatment with a DIPJ splint in slight hyperextension for tendon lesions or straight for bony avulsions depends on patient compliance. Surgical treatments vary in terms of the approach, the reduction technique, and the means of fixation. The risks involved are stiffness, septic arthritis, and osteoarthritis. Given the lack of consensus regarding indications for treatment, we propose to treat all cases of mallet finger with a dorsal glued splint except for stage IV mallet finger, which we treat with extra-articular pinning.

Dosimetric Characteristics of Dynamic Wedge Technique (Dynamic Wedge의 조직내 방사선량 분포의 특성)

  • Oh Young Taek;Keum Ki Chang;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.323-332
    • /
    • 1996
  • Purpose : The wedge filter is the most commonly used beam modifying device during radiation therapy Recently dynamic wedge technique is available through the computer controlled asymmetric collimator, independent jaw. But dosimetric characteristics of dynamic wedge technique is not well known. Therefore we evaluate dosimetric characteristics of dynamic wedge compared to conventional fixed wedge. Materials and Methods : We evaluated dosimetric characteristics of dynamic wedge and fixed wedge by ion chamber, film dosimetry and TLD in phantoms such as water, polystyrene and average breast phantom. Six MV x-ray was used in $15{\times}15cm$ field with 15,30 and 45 degree wedge of dynamic/liked wedge system, Dosimeric characteristics are interpreted by Wellhofer Dosimetrie system WP700/WP700i and contralateral breast dose (CBD) with tangential technique was confirmed by TLD. Results : 1) Percent depth dose through the dynamic wedge technique in tissue equivalent phantom was similar to open field irradiation and there was no beam hardening effect compared to fixed wedge technique. 2) Isodose line composing wedge angle of dynamic wedge is more straight than hard wedge. And dynamic wedge technique was able to make any wedge angle on any depth and field size. 3) The contralateral breast dose in primary breast irradiation was reduced by dynamic wedge technique compared to fixed wedge. When the dynamic wedge technique was applied, the scatter dose was similar to that of open field irradiation. Conclusion : The dynamic wedge technique was superior to fixed wedge technique in dosimetric characteristics and may be more useful in the future.

  • PDF

Seismic Traveltime Tomography in Anisotropic Black Shale (이방성 특성이 강한 흑색 셰일에서 탄성파 주시 토모그래피)

  • Kang, Jong-Seok;Cha, Young-Ho;Lee, Kwang-Bae;Jo, Churl-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.393-398
    • /
    • 2007
  • Seismic traveltime tomography technique was conducted at a site composed of black shale. It is well known that black shale has strong anisotropic property. Therefore, the anisotropic property of black shale has to be considered to obtain the appropriate subsurface velocity model by an inversion process. To estimate the anisotropic constant of the velocity of the black shale in the survey area, the relation between the velocity, which is calculated by the straight ray path and the first arrival time, and the angle of the ray propagation was examined. The elliptically shaped relation was found and it reveals that the black shale contains the anisotropic property of velocity. It was also noticed that the horizontal velocity is faster than the vertical velocity. When the estimated anisotropic constant was applied in the process of the velocity inversion for three sets of field data, we could obtain the appropriate velocity structures of the site that is consistent with the result of the geological survey.

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

The Optimal Configuration of Arch Structures Using Force Approximate Method (부재력(部材力) 근사해법(近似解法)을 이용(利用)한 아치구조물(構造物)의 형상최적화(形狀最適化)에 관한 연구(研究))

  • Lee, Gyu Won;Ro, Min Lae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.95-109
    • /
    • 1993
  • In this study, the optimal configuration of arch structure has been tested by a decomposition technique. The object of this study is to provide the method of optimizing the shapes of both two hinged and fixed arches. The problem of optimal configuration of arch structures includes the interaction formulas, the working stress, and the buckling stress constraints on the assumption that arch ribs can be approximated by a finite number of straight members. On the first level, buckling loads are calculated from the relation of the stiffness matrix and the geometric stiffness matrix by using Rayleigh-Ritz method, and the number of the structural analyses can be decreased by approximating member forces through sensitivity analysis using the design space approach. The objective function is formulated as the total weight of the structures, and the constraints are derived by including the working stress, the buckling stress, and the side limit. On the second level, the nodal point coordinates of the arch structures are used as design variables and the objective function has been taken as the weight function. By treating the nodal point coordinates as design variable, the problem of optimization can be reduced to unconstrained optimal design problem which is easy to solve. Numerical comparisons with results which are obtained from numerical tests for several arch structures with various shapes and constraints show that convergence rate is very fast regardless of constraint types and configuration of arch structures. And the optimal configuration or the arch structures obtained in this study is almost the identical one from other results. The total weight could be decreased by 17.7%-91.7% when an optimal configuration is accomplished.

  • PDF