• Title/Summary/Keyword: Story Structure

Search Result 1,203, Processing Time 0.025 seconds

An Approach for Generating Story-Plot Using Association Analysis of Narrative Patterns (서사 패턴의 연관분석을 통한 이야기 장면 생성 방법)

  • Kim, Jung-Il;Lee, Eun-Joo
    • Journal of Information Technology Services
    • /
    • v.12 no.1
    • /
    • pp.247-257
    • /
    • 2013
  • A narrative structure is essential for a story generator to create a story plot. In digital storytelling system, a narrative structure can be generally designed as a tree or a graph, and the story generator in the digital storytelling system creates continuous story plots based on the narrative structure. When a narrative structure is designed with a tree or a graph, it is hard for the story generator to create various kinds of story-plots due to the inflexible nature of a tree or graph structure. It may result in degrading the quality of story-plots to provide similar story-plot to various kind of user. In this paper, we proposed an approach to create a story-plot based on association analysis of data mining to overcome the disadvantage. In detail, we defined a narrative structure which consists of narrative patterns, and then implemented a story generator which creates a story-plot using the proposed narrative structure. As a result, we confirmed that implemented story generator was able to create a story-plot according to understanding level of user in case study.

Key technologies research on the response of a double-story isolated structure subjected to long-period earthquake motion

  • Liang Gao;Dewen Liu;Yuan Zhang;Yanping Zheng;Jingran Xu;Zhiang Li;Min Lei
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.17-30
    • /
    • 2024
  • Earthquakes can lead to substantial damage to buildings, with long-period ground motion being particularly destructive. The design of high-performance building structures has become a prominent focus of research. The double-story isolated structure is a novel type of isolated structure developed from base isolated structure. To delve deeper into the building performance of double-story isolated structures, the double-story isolated structure was constructed with the upper isolated layer located in different layers, alongside a base isolated structure for comparative analysis. Nonlinear elastoplastic analyses were conducted on these structures using different ground motion inputs, including ordinary ground motion, near-field impulsive ground motion, and far-field harmonic ground motion. The results demonstrate that the double-story isolated structure can extend the structural period further than the base isolated structure under three types of ground motions. The double-story isolated structure exhibits lower base shear, inter-story displacement, base isolated layer displacement, story shear, and maximum acceleration of the top layer, compared to the base isolated structure. In addition, the double-story isolated structure generates fewer plastic hinges in the frame, causes less damage to the core tube, and experiences smaller overturning moments, demonstrating excellent resistance to overturning and a shock-absorbing effect. As the upper isolated layer is positioned higher, the compressive stress on the isolated bearings of the upper isolated layer in the double-story isolated structure gradually decreases. Moreover, the compressive stress on the isolated bearings of the base isolated layer is lower compared to that of the base isolated structure. However, the shock-absorbing capacity of the double-story isolated structure is significantly increased when the upper isolated layer is located in the middle and lower section. Notably, in regions exposed to long-period ground motion, a double-story isolated structure can experience greater seismic response and reduced shock-absorbing capacity, which may be detrimental to the structure.

Story Comprehension of 2- and 3-year-olds According to Story Structure (이야기 구조에 따른 만 2, 3세 유아의 이야기 이해)

  • Kim, Hyo Young;Yi, Soon Hyung
    • Korean Journal of Child Studies
    • /
    • v.26 no.1
    • /
    • pp.15-29
    • /
    • 2005
  • This study investigated 2- and 3-year-olds' story comprehension by story structure, Sixty-eight children from day-care centers in Seoul and Kyunggi province were tested story comprehension about causal, noncausal, discontinuous story presented by pictures. Story comprehension included literal, inferential, & empathic comprehension, Data were analysed by ANOVA(repeated measure) and t-test. The result showed that 3-year-olds scored higher in literal and inferential comprehension than 2-year-olds. Children's story comprehension(literal, inferential, & empathic) scores were higher in causal structure than discontinuous and noncausal structure.

  • PDF

Performance Evaluation of Vibration Control of a Smart Top-Story Isolation System (스마트 최상층 면진시스템의 진동제어 성능평가)

  • Kang, Joo-Won;Kim, Tae-Ho;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.3
    • /
    • pp.49-56
    • /
    • 2010
  • In this study, the control performance of a smart top-story isolation system for tall buildings subjected to wind excitation was investigated. To this end, a 77-story tall building structure was employed and wind loads obtained from wind tunnel test were used for numerical simulations. The top-story of an example structure is separated from the main structure by a smart base isolation system composed of friction pendulum systems (FPS) and MR dampers. The primary purpose of the smart top-story isolation system is to mitigate the dynamic responses of the main structure, but the excessive movement of the isolated top story may cause the unstableness of the building structure. Therefore, the skyhook control algorithm was used to effectively reduce both responses of the isolated top story and the main structure. The control performance of the proposed smart top-story isolation system was investigated in comparison with that of the passive top-story isolation system. It has been shown from numerical simulation results that the smart top-story isolation system can effectively reduce wind-induced responses of the example building structure compared to the passive top-story isolation system with reduction of the top-story movement.

  • PDF

The Effects of Whole Language Program Using Story Books on Hearing Impaired Children's Language Abilities and Story Structures Concepts (동화를 사용한 총체적 언어접근이 청각장애 아동의 언어능력과 이야기 구조화 능력에 미치는 영향)

  • Park, Sun-Hwa;Kim, Mun-Jung;Seok, Dong-Il
    • Speech Sciences
    • /
    • v.15 no.3
    • /
    • pp.117-131
    • /
    • 2008
  • The purpose of this study was to determine the effects of whole language approach on the development of language abilities and story structure concepts for hearing impaired children. For this end, two research questions have been established. First, what is the effect of whole language program using story books on hearing impaired children’s language abilities? Second, what is the effect of whole language program using story books on hearing impaired children's story structure concept? Three subjects participated in the study. Each subject was scheduled for a 40-minute session two times a week. Subjects received 36 sessions of use animation activities for 3 months. The study used a multiple baseline across the subjects. The followings were the findings of this study. First, the whole language program using story books improved hearing impaired children's language abilities. Second, the whole language program using story books improved hearing impaired children's story structure concept.

  • PDF

A Study on Optimum Distribution of Story Shear Force Coefficient for Seismic Design of Multi-story Structure

  • Oh, Sang Hoon;Jeon, Jongsoo
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.121-145
    • /
    • 2014
  • The story shear force distributions of most seismic design codes generally reflect the influences of higher vibration modes based on the elastic deformations of structures. However, as the seismic design allows for the plastic behavior of a structure, the story shear force distribution shall be effective after it is yielded due to earthquake excitation. Hence this study conducted numerical analyses on the story shear force distributions of most seismic design codes to find out the characteristics of how a structure is damaged between stories. Analysis results show that the more forces are distributed onto high stories, the lower its concentration is and the more energy is absorbed. From the results, this study proposes the optimum story shear force distribution and its calculation formula that make the damages uniformly distributed onto whole stories. Consequently, the story damage distribution from the optimum calculation formula was considerably more stable than existing seismic design codes.

Simultaneous Optimization of Hybrid Mid-Story Isolation System and Building Structure (하이브리드 중간층 지진 격리 시스템과 빌딩 구조물의 동시 최적화)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.51-59
    • /
    • 2019
  • A hybrid mid-story seismic isolation system with a smart damper has been proposed to mitigate seismic responses of tall buildings. Based on previous research, a hybrid mid-story seismic isolation system can provide effective control performance for reduction of seismic responses of tall buildings. Structural design of the hybrid mid-story seismic isolation system is generally performed after completion of structural design of a building structure. This design concept is called as an iterative design which is a general design process for structures and control devices. In the iterative design process, optimal design solution for the structure and control system is changed at each design stage. To solve this problem, the integrated optimal design method for the hybrid mid-story seismic isolation system and building structure was proposed in this study. An existing building with mid-story isolation system, i.e. Shiodome Sumitomo Building, was selected as an example structure for more realistic study. The hybrid mid-story isolation system in this study was composed of MR (magnetorheological) dampers. The stiffnessess and damping coefficients of the example building, maximum capacity of MR damper, and stiffness of isolation bearing were simultaneously optimized. Multi-objective genetic optimization method was employed for the simultaneous optimization of the example structure and the mid-story seismic isolation system. The optimization results show that the simultaneous optimization method can provide better control performance than the passive mid-story isolation system with reduction of structural materials.

Seismic retrofit of a soft first story structure considering soil effect

  • Michael Adane;Jinkoo Kim
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.345-352
    • /
    • 2023
  • This paper studied the effect of soil-structure interaction (SSI) on the seismic response and retrofit of a reinforced concrete structure with a soft-first story for different soil types. A 5-story structure built on a 30m deep homogeneous soil mass was considered as a case study structure, and steel column jacketing and steel bracing were chosen as seismic retrofit methods. Seismic responses of a fixed-base and a flexible base structure subjected to seven scaled earthquake records were obtained using the software OpenSees to investigate the effect of soil on seismic response and retrofit. The nonlinearBeamColumn elements with the fiber sections were used to simulate the nonlinear behavior of the beams and columns. Soil properties were defined based on shear wave velocity according to categorized site classes defined in ASCE-7. The finite element model of the soil was made using isoparametric four-noded quadrilateral elements and the nonlinear dynamic responses of the combined system of soil and structure were calculated in the OpenSees. The analysis results indicate that the soil-structure interaction plays an important role in the seismic performance and retrofit of a structure with a soft-first story. It was observed that column steel jacketing was effective in the retrofit of the model structure on a fixed base, whereas stronger retrofit measures such as steel bracing were needed when soil-structure interaction was considered.

Effectiveness of seismic isolation in a reinforced concrete structure with soft story

  • Hakan Ozturk;Esengul Cavdar;Gokhan Ozdemir
    • Structural Engineering and Mechanics
    • /
    • v.87 no.5
    • /
    • pp.405-418
    • /
    • 2023
  • This study focused on the effectiveness of seismic isolation technique in case of a reinforced concrete structure with soft story defined as the stiffness irregularity between adjacent stories. In this context, a seismically isolated 3-story reinforced concrete structure was analyzed by gradually increasing the first story height (3.0, 4.5, and 6.0 m). The seismic isolation system of the structure is assumed to be composed of lead rubber bearings (LRB). In the analyses, isolators were modeled by both deteriorating (temperature-dependent analyses) and non-deteriorating (bounding analyses) hysteretic representations. The deterioration in strength of isolator is due to temperature rise in the lead core during cyclic motion. The ground motion pairs used in bi-directional nonlinear dynamic analyses were selected and scaled according to codified procedures. In the analyses, different isolation periods (Tiso) and characteristic strength to weight ratios (Q/W) were considered in order to determine the sensitivity of structural response to the isolator properties. Response quantities under consideration are floor accelerations, and interstory drift ratios. Analyses results are compared for both hysteretic representations of LRBs. Results are also used to assess the significance of the ratio between the horizontal stiffnesses of soft story and isolation system. It is revealed that seismic isolation is a viable method to reduce structural damage in structures with soft story.

Creating Simultaneous Story Arcs Using Constraint Based Narrative Structure (제약 조건 기반 서술구조를 이용한 동시 진행 이야기의 생성)

  • Moon, Sung-Hyun;Kim, Seok-Kyoo;Hong, Euy-Seok;Han, Sang-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.107-114
    • /
    • 2010
  • A nonlinear story is generated through the interactivity with users using the interactive storytelling system. In a play or movie, audiences can watch one scene at a time, and in order to watch next scene, they should wait for the end of current scene. In the real world, however, various events can simultaneously happen at different places, and even those events performed by characters may dramatically affect the flow of the story. This paper suggests Constraint Based narrative structure to create such story, known as "Simultaneous Story Arcs", and "Multi Viewpoint" to simultaneously lead the direction of the stories in each place.