• Title/Summary/Keyword: Storage-area

Search Result 1,717, Processing Time 0.33 seconds

A Study on the Establishment of Optimum Design Conditions and Economic Evaluation for Rot Water Heating Solar Energy System (태양열(太陽熱) 급탕(給湯)시스템의 최적설계(最適設計) 조건(條件)의 설정(設定)과 경제성(經濟性) 평가(評價)에 관한 연구(硏究))

  • Lee, Young-Soo;Lee, Ki-Woo
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.47-59
    • /
    • 1986
  • This paper presents the establishment of optimum design conditions and economic evaluation for solar hot water system. The aim of this study is to present thermal performance of solar heating systems and to determine their performance as a function of collector size, storage capacity, tilting of collector and other factors. By analyzing its performance under the various conditions, optimum design of solar heating system can be obtained. System performance are obtained monthly and yearly basis respectively. At the same time the economics of various systems are evaluated. For the computer simulation Mokpo, Kangnung, Chupungnyong and Seoul are selected for particular installation places. As a result, the optimal design condition of solar heating system considering the following factors such as installation angle of collector, capacity of storage tank, collector size in each place can be obtained as follows; (1) Installation angle of collector Tilt = lattitude (2) Capacity of storage tank Solar domestic hot water system : $45\;1/m^2$ Multifamily solar domestic hot water system : $35\;1/m^2$ (3) Collector size i) Solar domestic hot water system Seoul & Chupyungyong area : $11.52\;m^2$ Mokpo area : $8.64\;m^2$ ii) Multifamily solar domestic hot water system Seoul, Chupyungyong & Mokpo area : $345.6\;m^2$ Kangnung area : $259.2\;m^2$

  • PDF

Wide Area Storage Networking (광대역 스토리지 네트워킹)

  • Ha Cheul-Seh
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.142-146
    • /
    • 2004
  • 과거와 달리 21세기의 도래로 주변에 많은 전산화 및 정보화작업이 이루어지면서 데이터 트래픽이 폭발적으로 증가하고, 정보 통신망은 이를 수용하기 위해서 전반적인 큰 변화를 겪어 왔으며 현재도 겪고 있는 중이다. 또한 정보의 중요성을 인식하면서 부터 많은 기업들이나 개인들이 정보의 손실을 의식하고 있으며 정보를 안전하게 저장하고 원활하게 활용할 수 있는 방법을 모색하게 되면서 SAN(Storage Area Network)에 대한 의존도가 높아지게 되었다. 본 고는 현재 사용도 가 높아지고 있는 Fibre Channel을 이용한 SAN전송로의 구성 및 동향에 대하여 살펴본다.

  • PDF

A Study of Next Generation Security Infrastruction for Wireless Storage Area Network (무선 Storage Area Network의 차세대 보안 인프라 연구)

  • 함동읍;김동수;김지호;송오영;박세현
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 2003.12a
    • /
    • pp.360-365
    • /
    • 2003
  • 무선 단말기를 통한 멀티미디어 데이터의 이용증가로 인해 무선 단말기의 저장 용량 한계에 대한 문제가 제기되었다. 지속적으로 성장하고 있는 무선 인프라 상에서 사용자의 중요한 데이터를 완벽하게 보호하고 시스템 장애 시간을 최소화하여 사용자가 언제든 원하는 데이터를 저장하고, 제공받기 위해 SAN 보안 인프라 연구는 필수적이다.

  • PDF

Provision of Two-area Automatic Generation Control by Demand-side Electric Vehicle Battery Swapping Stations

  • Xie, Pingping;Shi, Dongyuan;Li, Yinhong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.300-308
    • /
    • 2016
  • Application of demand-side resources to automatic generation control (AGC) has a great significance for improving the dynamic control performance of power system frequency regulation. This paper investigates the possibility of providing regulation services by demand-side energy storage in electric vehicle battery swapping stations (BSS). An interaction framework, namely station-to-grid (S2G), is presented to integrate BSS energy storage into power grid for giving benefits to frequency regulation. The BSS can be regarded as a lumped battery energy storage station through S2G framework. A supplementary AGC method using demand-side BSS energy storage is developed considering the vehicle user demand of battery swapping. The effects to the AGC performance are evaluated through simulations by using a two-area interconnected power grid model with step and random load disturbance. The results show that the demand-side BSS can significantly suppress the frequency deviation and tie-line power fluctuations.

Changes of Flavor Components in Chewing Gum during Storage by Gas Chromatography/Mass Spectrometry (GC/MS에 의한 저장중 츄잉껌 향기성분 변화연구)

  • Shin, Seong-Kee;Kim, Sang-Ho;Lee, Yoon-Hyung;Rhee, Kyu-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.25-28
    • /
    • 1992
  • The changes of amount in flavor components of chewing gum during storage of various relative humidity were studied by GC/MS. The volatile components in chewing gum were extracted by sample preperation and 15 volatile components were identified by NIST/NBS library searching. According to the period of storage, quantities of major volatile components extracted by tetrahydrofuran-methanol solutions were determined by using tetradecane as internal standard. Until 4 weeks, comparing with starting peak area ratio, the decrease of chewing gum flavor components were rapid at 33, 75 than 53 R.H(%). And after 16 weeks, amount of chewing gum flavor at all storage conditions similarly decreased to $45{\sim}49%$ of the initial amount.

  • PDF

Electrostatic 2-axis MEMS Stage with a Large Area Platform for Probe-based Storage Devices (대면적 플랫폼을 갖는 Probe-based Storage Device(PSD)용 정전형 2축 MEMS 스테이지)

  • Chung, Il-Jin;Jeon, Jong-Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.179-189
    • /
    • 2006
  • Recently the electrostatic 2-axis MEMS stages have been fabricated f3r the purpose of an application to PSD (Probe-based Storage Device). However, all of the components (platform, comb electrodes, springs, anchors, etc.) in those stages are placed in-plane so that they have low areal efficiencies such as a few percentage, which is undesirable as data storage devices. In this paper, we present a novel structure of an electrostatic 2-axis MEMS stage that is characterized by having a large areal efficiency of about 25%. For obtaining large area efficiency, the actuator part consisting of mainly comb electrodes and springs is placed right below the platform. The structure and operational principle of the MEMS stage are described, followed by a design and analysis, the fabrication and measurement results. Experimental results show that the driving ranges of the fabricated stage along the x and y axis were 27$\mu$m, 38$\mu$m at the supplied voltages of 65V, 70V, respectively and the natural frequencies along x and y axis were 180Hz, 310Hz, respectively. The total size of the stage is about 5.9$\times$6.8mm$^2$ and the platform size is about 2.7$\times$3.6mm$^2$.

Performance Tests on a Solar Water Heating System in Thermosyphonic Flow (열사이폰식 태양열 온수시스템의 성능실험)

  • Kim, Doo-Chun;Park, Seung-Duk
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.9 no.2
    • /
    • pp.93-103
    • /
    • 1980
  • A small domestic solar water heating system in thermosyphonic flow was tested in Seoul. The system consisted of four flat plate aluminium roll bond type collectors of total effective area $3.28m^2$ and a $280{\iota}$ storage tank. It was tilted $52^{\circ}$ relative to the horizon. And the collector plate, collector tube and storage tank were equiped with 14 thermocouples. As the results, the following facts were found; 1) To provide water at $55^{\circ}C$ for a family of four in Seoul, a collector area of $3-4m^2$ and a storage capacity of $180{\iota}- 200{\iota}$ are suggested. And this system can supply hot water at above $45^{\circ}C$ day about. 2) In the late afternoon hours, it might be advantageous to stop the flow in the system as heat losses to the environment increase unduly. 3) Without any hot water consumption throughout the day, water temperature distributions inside the storage tank was found almost linear. This indicates essentially no mixing inside the storage tank. 4) In case of a small domestic solar water heating system, it is better to employ a single transparent cover rather than double one.

  • PDF

A Study on Change of the Apartment Storage Space (아파트 수납공간의 양적변화에 관한 연구)

  • 박영순
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.1
    • /
    • pp.97-109
    • /
    • 1989
  • The purpose of this study was to find out change of the apartments stouge space in Seoul area from 1971 to 1988. It also attempts to compare the storage space in the apartment with the optimum storage space which is suggested by precedent studies on the storage space. Content analysis methods were used to analyze 961 apartment floor plan from the booklet of 'Apartment Information'. The major findings were as follows : 1) According to the precedent studies, optimum storage spaces are 3.86∼7.72㎡ for 66.07∼115.61㎡ house, and 14.23∼20.31㎡ for 115.62∼165.15㎡ house. 2) It was found out that the storage spaces of the apartments were increased until 1977∼80 and decreased after 1980. 3) Comparing the storge space with the optimum standard, most of the apartments have not enough storage space. It offers only 50% of optimum storage space. 4) The percentage of installation of storage space in bedrooms were quite low in general. Specially, bedrooms in small apartment under 66.6㎡ and most master bedrooms didn't storage spaces. 5) The sige of the apartment storage space were variant according to the builder. Only one builder from 8 offered the spaces close to the optimum standrd, and others didn't seem much care for the storage space.

  • PDF

Optimal Mixed Storage Methods Considering Rehandles of Inventories (재취급을 고려한 최적 혼적결정법)

  • Yang, Jee Hyun;Kim, Kap Hwan;Won, Seung Hwan
    • Journal of Intelligence and Information Systems
    • /
    • v.12 no.3
    • /
    • pp.33-46
    • /
    • 2006
  • In order to decrease the number of handles, speed up retrieval operations, and manage products efficiently, the investment of facilities such as the installation of the storage equipment and the enlargement of the storage area may be attempted. However, the same objectives can be accomplished by utilizing the existing storage area efficiently. In many types of storage facilities, because of the limitation of storage areas, products are usually piled up, which may cause rehandles of inventories. Rehandles influence significantly the handling efficiency of warehouses. This study develops methods for minimizing rehandles of inventories to improve the operational efficiency of warehouses. A mixed storage problem is addressed for minimizing the expected number of rehandles. Optimization models are proposed and the genetic algorithm is applied to solve the problem.

  • PDF

The CO2 Reduction Potential Calculation through the Urban Park Construction

  • Lee, Eun Yeob;Kang, Myung Soo;Kim, Jong Kon
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.87-98
    • /
    • 2014
  • This study is to identify quantitatively the function of carbon dioxide emissions reduction due to temperature and energy reduction according to direct carbon dioxide storage, shade provision, and evaportanspiration of urban park. According to the result of study, landscape tree indicated high carbon dioxide storage effect compare to bush, in which broadleaf tree indicated higher storage function than coniferous tree. It is believed to be the storage of carbon dioxide can be increased by increasing the composition rate of forest plants in the urban park. According to the direct estimation result of carbon dioxide storage in terms of example area, storage of carbon dioxide is estimated to be "seoul a zone" $476,818.8kg{\cdot}CO_2/m^2yr$, "anyang b zone" $186,435.7{\cdot}CO_2/m^2yr$, "daejeon c zone" $262,826{\cdot}CO_2/m^2yr$, "kwangju d zone" $231,657.8{\cdot}CO_2/m^2yr$. The carbon dioxide storage per unit area estimated to be "seoul a zone" $3.4{\cdot}CO_2/m^2yr$, "anyang b zone" $5.0{\cdot}CO_2/m^2yr$, "daejeon c zone" $2.6{\cdot}CO_2/m^2yr$, "kwangju d zone" $5.6{\cdot}CO_2/m^2yr$. The result of indirect carbon dioxide reduction effect estimated to be "seoul a zone" $291,603.4{\cdot}CO_2/m^2yr$, "anyang b zone" $165,462.4{\cdot}CO_2/m^2yr$, "daejeon c zone" $141,719.2{\cdot}CO_2/m^2yr$, "kwangju d zone" $154,803.4{\cdot}CO_2/m^2yr$. Carbon dioxide reduction potential amount through the urban park was increased to 1.6 times to 1.8 times when calculated to the indirect effect.